scholarly journals Using Molecular Techniques for the Characterization of Escherichia coli Isolated from Creek Road/Bonny Estuary in Rivers State, Nigeria

Author(s):  
Constancy Prisca Aleru ◽  
Kinikanwo Confidence Wachukwu

This study characterised Escherichia coli isolated from Creek Road/Bonny Estuary using molecular techniques. One hundred and twenty (120) water samples were investigated for the presence of E. coli in Creek Road/Bonny Estuary. Most Probable Number (MPN) Technique, Eijkman test and molecular techniques were used for the isolation and detection of E. coli. The analysis was carried out periodically (morning and evening) and seasonally (end of rainy season (November), the start of rainy season (April) and in the middle of rainy season (July)). All E. coli isolates were screened for resistance genes in the pathotypes of E. coli (EHEC, EPEC, EAEC, ETEC and EIEC), including Sulfhydryl Variable (SHV), CTX-M, Temoniera (TEM) and MCR genes using the Polymerase chain reaction Technique. The results showed that 100% of the water samples were positive for coliforms and all the water samples harboured E. coli. The highest total coliforms count recorded was in the morning of April (48 MPN/100 ml). The distribution of individual genes in the E. coli isolates are: SHV (5.0), CTX-M (5.8), TEM (4.2), MCR (0.0%), stx1 and stx2 (4.2), esV and bfA (1.7), aaiC (4.2), elt (3.3) and invE (2.5). The CTX-M was the most found of all the resistance genes.

2020 ◽  
Vol 36 (2) ◽  
pp. 75-77
Author(s):  
Anindita Bhowmik ◽  
Sunjukta Ahsan

Majority of the population of Bangladesh depend on tap or surface water as their source of water supply. This study was carried out to examine the microbial quality of both water and soil collected from different places using the multiple tube fermentation technique to determine coliform count by the most probable number (MPN) method in brilliant green lactose broth (BGLB) media.Inoculum from positive tubes of the presumptive test were further transferred on eosinemethylene blue (EMB) and MacConkey agar.The organisms isolated were further characterized using biochemical tests. Out of 93 water samples, 30 (32.26%) indicated the presence of lactose fermenter and gas producer in all 3 tubes of dilution series using inoculum quantities of 1.0, 0.1 and 0.01 ml, whereas out of 85 soil samples, 45 (52.94%) showed acid and gas production in all 3 tubes of dilution series.Among 85 soil samples, 40 samples that contained at least one positive in each dilution series and among 93 water samples, 31 samples that contained at least one positive in each dilution series were further re-identified with biochemical tests.This study showed 30.59% soil isolates and 26.88% water isolates were Escherichia coli which highlighted the fact that both water and soil act as a major reservoir of E.coli, which indicates possible fecal contamination as well as presence of potentially pathogenic E. coli. Bangladesh J Microbiol, Volume 36 Number 2 December 2019, pp 75-77


Jurnal BIOMA ◽  
2017 ◽  
Vol 11 (1) ◽  
pp. 73
Author(s):  
Rezki Rachmawati ◽  
Muzajjanah Muzajjanah ◽  
Yoswita Rustam

Refill Water Depot is currently more widely circulated and used as an alternative drinking water supply by the public. However the still unclear about the quality of the drinking water refill generated primarily of biological content. Parameters of biological contamination in drinking water caused by the Escherichia coli and coliform bacterium. This study aims to identify E. coli and coliforms in drinking water refill. Refill drinking water samples obtained from 16 drinking water refill from Jagakarsa subdsitrict. The method used is descriptive. Refill drinking water samples was taken and tested in the MPN (Most Probable Number) method and then to be tested in identification of E. coli. The results of testing the drinking water refill obtained 15 samples positive for coliform bacteria. Samples were positive for E. coli bacteria that sample B.1 and F.2.


2021 ◽  
Vol 10 (1) ◽  
pp. 23
Author(s):  
Muhammad Rayhan Braja Gitawama ◽  
Netti Suharti ◽  
Nora Harminarti

The National Food and Drug Agency has controlled the refill drinking water in drinking water depots and also controlled food at school canteens ranging from elementary, junior high, to high school, but the National Food and Drug Agency never do food quality controlling in canteens at universities. Objectives: To identified the contamination by coliform and E. coli bacteria in drinking water at Andalas University canteen. Methods: This research was descriptive to identify coliform bacteria on  15 drinking water at the Andalas University faculty canteens.  Samples were taken directly using a sterile bottle, while data analysis using Most Probable Number  (MPN)  tables 5-1-1 and the presence of E. coli bacteria colonies from drinking water samples. Results: 9 of 15 water samples were contaminated by coliform bacteria with the highest MPN index of 240/100 ml that was found in 2 samples. From 9 samples containing coliform bacteria, all of them were found to contain E. coli bacteria. Conclusion: Most of the samples were contaminated by coliform and E. coli bacteria. Drinking water served using a kettle was more contaminated than drinking water served using gallons.Keywords: Coliform, Escherichia coli, MPN


2000 ◽  
Vol 63 (9) ◽  
pp. 1184-1188 ◽  
Author(s):  
J. A. CASON ◽  
A. HINTON ◽  
K. D. INGRAM

Scald water samples from a commercial broiler processing plant were tested for coliforms, Escherichia coli, and salmonellae to evaluate the numbers of suspended bacteria in a multiple-tank, counterflow scalder. Water samples were taken from each of three tanks on 8 different days after 6-week-old broilers had been processed for 8 h. Coliforms and E. coli were counted using Petrifilm, and the most probable number (MPN) of salmonellae was determined both in water samples and in rinses of defeathered carcasses that were removed from the processing line immediately after taking the water samples. Mean coliform concentrations in tanks 1, 2, and 3 (the last tank that carcasses pass through before being defeathered) were 3.4, 2.0, and 1.2 log10(CFU/ml), respectively. E. coli concentrations followed the same pattern with means of 3.2, 1.5, and 0.8 in tanks 1, 2, and 3, respectively, with significant differences (P < 0.02) in the concentrations of both coliforms and E. coli between the tanks. Sixteen of 24 scald-water samples were positive for salmonellae with a geometric mean of 10.9 MPN/100 ml in the positive samples. Salmonellae were isolated from seven of eight water samples from both tanks 1 and 2, but in only two of eight water samples from tank 3, the last tank that carcasses pass through. It appears that most bacteria removed from carcasses during scalding are washed off during the early part of scalding.


Jurnal BIOMA ◽  
2017 ◽  
Vol 11 (1) ◽  
pp. 73
Author(s):  
Rezki Rachmawati ◽  
Muzajjanah Muzajjanah ◽  
Yoswita Rustam

Refill Water Depot is currently more widely circulated and used as an alternative drinking water supply by the public. However the still unclear about the quality of the drinking water refill generated primarily of biological content. Parameters of biological contamination in drinking water caused by the Escherichia coli and coliform bacterium. This study aims to identify E. coli and coliforms in drinking water refill. Refill drinking water samples obtained from 16 drinking water refill from Jagakarsa subdsitrict. The method used is descriptive. Refill drinking water samples was taken and tested in the MPN (Most Probable Number) method and then to be tested in identification of E. coli. The results of testing the drinking water refill obtained 15 samples positive for coliform bacteria. Samples were positive for E. coli bacteria that sample B.1 and F.2.


1999 ◽  
Vol 122 (2) ◽  
pp. 185-192 ◽  
Author(s):  
J. TUTTLE ◽  
T. GOMEZ ◽  
M. P. DOYLE ◽  
J. G. WELLS ◽  
T. ZHAO ◽  
...  

Between November 1992 and February 1993, a large outbreak of Escherichia coli O157[ratio ]H7 infections occurred in the western USA and was associated with eating ground beef patties at restaurants of one fast-food chain. Restaurants that were epidemiologically linked with cases served patties produced on two consecutive dates; cultures of recalled ground beef patties produced on those dates yielded E. coli O157[ratio ]H7 strains indistinguishable from those isolated from patients, confirming the vehicle of illness. Seventy-six ground beef patty samples were cultured quantitatively for E. coli O157[ratio ]H7. The median most probable number of organisms was 1·5 per gram (range, <0·3–15) or 67·5 organisms per patty (range, <13·5–675). Correlation of the presence of E. coli O157[ratio ]H7 with other bacterial indicators yielded a significant association between coliform count and the presence of E. coli O157[ratio ]H7 (P=0·04). A meat traceback to investigate possible sources of contamination revealed cattle were probably initially colonized with E. coli O157[ratio ]H7, and that their slaughter caused surface contamination of meat, which once combined with meat from other sources, resulted in a large number of contaminated ground beef patties. Microbiological testing of meat from lots consumed by persons who became ill was suggestive of an infectious dose for E. coli O157[ratio ]H7 of fewer than 700 organisms. These findings present a strong argument for enforcing zero tolerance for this organism in processed food and for markedly decreasing contamination of raw ground beef. Process controls that incorporate microbiological testing of meat may assist these efforts.


2009 ◽  
Vol 75 (23) ◽  
pp. 7417-7425 ◽  
Author(s):  
H. N. Chinivasagam ◽  
T. Tran ◽  
L. Maddock ◽  
A. Gale ◽  
P. J. Blackall

ABSTRACT This study assessed the levels of two key pathogens, Salmonella and Campylobacter, along with the indicator organism Escherichia coli in aerosols within and outside poultry sheds. The study ranged over a 3-year period on four poultry farms and consisted of six trials across the boiler production cycle of around 55 days. Weekly testing of litter and aerosols was carried out through the cycle. A key point that emerged is that the levels of airborne bacteria are linked to the levels of these bacteria in litter. This hypothesis was demonstrated by E. coli. The typical levels of E. coli in litter were ∼108 CFU g−1 and, as a consequence, were in the range of 102 to 104 CFU m−3 in aerosols, both inside and outside the shed. The external levels were always lower than the internal levels. Salmonella was only present intermittently in litter and at lower levels (103 to 105 most probable number [MPN] g−1) and consequently present only intermittently and at low levels in air inside (range of 0.65 to 4.4 MPN m−3) and once outside (2.3 MPN m−3). The Salmonella serovars isolated in litter were generally also isolated from aerosols and dust, with the Salmonella serovars Chester and Sofia being the dominant serovars across these interfaces. Campylobacter was detected late in the production cycle, in litter at levels of around 107 MPN g−1. Campylobacter was detected only once inside the shed and then at low levels of 2.2 MPN m−3. Thus, the public health risk from these organisms in poultry environments via the aerosol pathway is minimal.


Author(s):  
YOJANA Y. PATIL ◽  
VAISHNVI B. SUTAR ◽  
ARPITA P. TIWARI

Objective: The present study was aimed at the biological synthesis of magnetic iron nanoparticles by using the plant extract of Tridax procumbens and also to study their antimicrobial property against gram-negative bacteria (Escherichia coli). Methods: The synthesis of magnetic iron nanoparticles was carried out by the co-precipitation method using biological methods like plant extract as reducing agent and capping agents are biocompatible and non-hazardous. These nanoparticles were characterized by UV-Visible spectroscopy, XRD (X-Ray Diffraction), and SEM (Scanning Electron Microscope). As well as antibacterial activity of the nanoparticles was carried out by agar well diffusion method and Most Probable Number (MPN) method against gram-negative E. coli (Escherichia coli) bacteria. Results: The average crystallite size of Magnetic Nanoparticles (MNPs) was found to be 72 nm by X-ray diffraction. The optical absorption band at wavelengths of 240 nm and 402 nm was obtained from the UV Visible spectrum. Spherical shape morphology was observed in SEM studies. The antibacterial assay clearly expressed that E. coli showed a maximum zone of inhibition (15±0.15 mm) at 2 mg/ml and 1 mg/ml concentration was found for Magnetic Nanoparticles. In the Most Probable Number (MPN) test it is seen that the bacterial count is reduced after adding synthesized NPs into the water sample. Conclusion: The results of the present study conclude that the Magnetic Nanoparticles synthesized using Tridax procumbens leaf extracts is found to be stable and show good antibacterial activity against gram-negative (Escherichia coli) bacteria.


2020 ◽  
Vol 6 (1) ◽  
pp. 1-5
Author(s):  
Natapol Pumipuntu ◽  
Sangkom Pumipuntu

Background and Aim: The problem of antimicrobial resistance of bacteria in both humans and animals is an important public health concern globally, which is likely to increase, including in Thailand, where carbapenem-resistant Enterobacteriaceae (CRE), such as Escherichia coli, are of particular concern. They are pathogens found in the gastrointestinal tract of humans and other animals as well as in the environment. They may cause opportunistic infection and are often resistant to antibiotics in various fields especially in animal husbandry, such as pets or livestock farms. This study aimed to investigate the occurrence of carbapenem-resistant E. coli from water samples of smallholder dairy farms in Saraburi and Maha Sarakham, Thailand. Materials and Methods: Sixty-four water samples were collected from 32 dairy farms in Kaeng Khoi district, Muak Lek district, and Wang Muang district of Saraburi Province, and Kantharawichai district and Mueang district of Maha Sarakham Province, Thailand. All samples were cultured and isolated for E. coli by biochemical tests. All E. coli isolates were tested for drug susceptibility using imipenem, meropenem, and drug resistance genes of carbapenemases such as blaNDM, blaIMP, and blaOXA48 of drug-resistant E. coli isolates detected by polymerase chain reaction (PCR) technique. Results: A total of 182 E. coli isolates were found (140 and 42 isolates from Saraburi and Maha Sarakham, respectively). Drug sensitivity tests found that two isolates of E. coli from water in Kaeng Khoi were resistant to imipenem; therefore, the incidence of E. coli resistance to carbapenem was 1.43% of Saraburi Province. On the other hand, there was no incidence of drug-resistant E. coli in Maha Sarakham. In addition, the detection of the drug-resistant gene of E. coli in both isolates by PCR showed the expression of blaNDM. Conclusion: This study reports E. coli resistance to antimicrobial drugs on livestock farms. It can be considered to be the first report of E. coli CRE detection in a dairy farm at Saraburi, which should be the subject of further extended study.


2019 ◽  
Vol 2 (2) ◽  
pp. a13-19
Author(s):  
ELEXSON NILLIAN ◽  
AMIZA NUR ◽  
DIYANA NUR ◽  
AMIRAH ZAKIRAH ◽  
GRACE BEBEY

Contamination of drinks with E. coli O157:H7 served in food premises such as restaurants can cause haemorrhagic colitis and haemolytic uremic syndrome to humans. The presence or absence of faecal pathogen was demonstrated using coliform group as indicator microorganisms. Therefore, this study was conducted to detect the presence of E. coli O157:H7 in drinking water from food restaurant premise in Kota Samarahan and Kuching to ensure safe and potable drinking water is served to the consumer. A total of thirty (n=30) drink samples including six types of each of the samples are cold plain water, iced tea, iced milo, syrup and iced milk tea. Most Probable Number (MPN) procedure was used in this study to enumerate the MPN values of coliform bacteria in each drink collected. A total of 53.33% (16/30) of the drink samples showed positive E. coli detection. Then, the PCR assay showed 6.25% (one out of 16 isolates) samples were positive and carried stx1 gene produced by E. coli O157:H7 in iced milo sample types. This study showed the drinks collected from food premises was contaminated with faecal contamination, which was not safe to drink by the consumer. Therefore, preventive actions should be taken to prevent foodborne illness outbreak in future


Sign in / Sign up

Export Citation Format

Share Document