pulse repetition rate
Recently Published Documents


TOTAL DOCUMENTS

359
(FIVE YEARS 61)

H-INDEX

29
(FIVE YEARS 5)

Nanomaterials ◽  
2022 ◽  
Vol 12 (2) ◽  
pp. 232
Author(s):  
Luka Hribar ◽  
Peter Gregorčič ◽  
Matej Senegačnik ◽  
Matija Jezeršek

In this paper, we investigate the influence of the following parameters: pulse duration, pulse repetition rate, line-to-line and pulse-to-pulse overlaps, and scanning strategy on the ablation of AISI 316L steel and CuZn37 brass with a nanosecond, 1064-nm, Yb fiber laser. The results show that the material removal rate (MRR) increases monotonically with pulse duration up to the characteristic repetition rate (f0) where pulse energy and average power are maximal. The maximum MRR is reached at a repetition rate that is equal or slightly higher as f0. The exact value depends on the correlation between the fluence of the laser pulses and the pulse repetition rate, as well as on the material properties of the sample. The results show that shielding of the laser beam by plasma and ejected material plays an important role in reducing the MRR. The surface roughness is mainly influenced by the line-to-line and the pulse-to-pulse overlaps, where larger overlap leads to lower roughness. Process optimization indicates that while operating with laser processing parameters resulting in the highest MRR, the best ratio between the MRR and surface roughness appears at ~50% overlap of the laser pulses, regardless of the material being processed.


2022 ◽  
Vol 52 (1) ◽  
pp. 69-77
Author(s):  
A V Belikov ◽  
S N Smirnov ◽  
Yu N Batov ◽  
A B Gubin ◽  
Yu B Pirozhkov ◽  
...  

Abstract Laser extraction of a model porcine eye cataract has been performed for the first time in an in vitro experiment using a 1.54-μm Yb,Er : glass laser generating bursts of microsecond pulses. We used effective pulse repetition rates from 36 to 75 Hz and average laser output powers from 3.9 to 5.25 W. The results demonstrate for the first time that, at an effective pulse repetition rate of 45 Hz, burst repetition rate of 15 Hz, three microsecond pulses per burst, and a burst energy from 260 to 265 mJ, the laser step duration in cataract extraction is 130 plusmn; 10 s, which is comparable to the ultrasonic phacoemulsification and laser extraction time in the case of a Nd : YAG laser emitting at 1.44 μm. Acoustometry and high speed video recording of hydroacoustic processes accompanying interaction of water with 1.54-μm radiation from the Yb, Er : glass laser generating bursts of microsecond pulses have made it possible for the first time to detect overlap of hydroacoustic processes at the pulse spacing in bursts reduced to under 700 μs. In the case of overlap of hydroacoustic processes, despite the increase in average power and effective pulse repetition rate, acoustic wave generation is ineffective because pulses propagate through bubbles formed in the water. Laser cataract extraction is shown to be most effective at a lower average power, lower effective pulse repetition rate, and burst pulse spacing of 850 ± 10 μs.


Scanning ◽  
2021 ◽  
Vol 2021 ◽  
pp. 1-7
Author(s):  
Dlsoz Omer Babarasul ◽  
Bestoon Mohammed Faraj ◽  
Fadil Abdullah Kareem

It is impossible to remove tooth-colored restorations by mechanical means without unnecessary damage to the adjacent sound tooth structure. This study is aimed at investigating erbium-doped yttrium aluminum garnet (Er: YAG) laser (Hoya ConBio, VersaWave, CA, USA) in removing composite resin restorations and assessing the change in morphology of bonding surfaces using a scanning electron microscope (EDX, CAMSCANNER, 3200LV, UK). The investigators collected thirty extracted sound human premolar teeth for this investigation, and the conventional design class V cavity was prepared on the buccal surface of each specimen. The specimens were allocated randomly into three groups, according to the procedure used for the ablation of the composite restoration: group A (high-speed diamond fissure bur), group B, and group C (Er: YAG laser) using a different pulse repetition rate of 20 Hz (group B) and 25 Hz (group C). The AutoCAD software program (Autodesk, Inc., 2016) was used to calculate the surface area and the resulting dimensional change of the cavities after restoration removal. The cavities were filled with composite resin and randomly assigned into two groups conforming to the methods applied to eliminate the restoration; diamond turbine fissure bur and laser. In each group, two specimens were selected randomly for scanning electron microscope analysis of bonding surfaces. The least meantime for the composite resin removal was observed in the high-speed diamond bur, significantly less than both Er-YAG laser groups ( p < 0.001 ). However, at a higher pulse repetition rate, time-consuming decreased. The results showed that laser is more conservative in removing composite resin restoration as the change was most remarkable in group A (0.800 mm), then group C (0.466 mm), and the slightest change is in group B (0.372 mm) ( p = 0.014 ). The dentin surface of group A showed a smooth surface with no opened dentinal tubule and intact smear layer. In groups B and C, dentin surfaces were irregular, scaly, or flaky, and dentinal tubules were opened without a smear layer. Therefore, Er: YAG laser is effective for composite resin removal considering the parameters chosen in this study with fewer changes in cavity surface area and better microretentive features.


Materials ◽  
2021 ◽  
Vol 14 (19) ◽  
pp. 5808
Author(s):  
Yi-Cheng Chen ◽  
Yi-Kai Hsiung ◽  
Chih-Yuan Chang ◽  
Shih-Fu Ou

Indium tin oxide (ITO) thin films on polycarbonate (PC) substrates were patterned using the laser direct-write (LDW) technique to form an isolation line. The effect of the LDW parameters (power, pulse repetition rate, and defocusing distance) on the isolation line width, depth and roughness of the PC within the line was investigated. Additionally, the Taguchi method of experimental design was applied to determine the optimal parameters of LDW. Results showed that increasing the power led to an increase in the isolation line width and decrease in the surface roughness of the PC within the line. The increase in the pulse repetition rate and defocusing distance caused a decrease in the isolation line width. The optimal parameters were found to be A2B3C3, consisting of power of 5 W, pulse repetition rate of 100 kHz, and defocusing distance of +3 mm. Under these parameters, we obtained an isolation line width of 48.4 μm, and a surface roughness of Ra 38 nm of the PC within the isolation line. We confirmed that the ITO films separated by the isolation lines attained electrical isolation.


2021 ◽  
Vol 2051 (1) ◽  
pp. 012003
Author(s):  
N S A Raman ◽  
I H W Nordin ◽  
M S A Majid ◽  
Z M Razlan ◽  
S S C Abdullah

Abstract The objective of this research is to understand the fundamental mechanisms that govern the formation of laser-induced molten area during the micro-grooved fabrication on silicon material. In this research work, micro grooves were fabricated on silicon wafer by using ultraviolet (UV) laser of 248nm wavelength. Influence of lasing parameters such as pulse duration, laser pulse energy and scanning speed on the surface of micro-grooved was characterized. It is found that, the width of the micro grooves become wider with increasing laser pulse energy when ultraviolet laser was irradiated on silicon material. On the other hand, heat affected zone (HAZ) can be found at the surface of micro groove line at high pulse energy, high pulse repetition rate and lower scanning speed irradiation condition. This is considered due to the excessive heat input of the laser irradiation condition. It is concluded that proper selection of laser processing parameters of pulse energy, E, pulse repetition rate, R p , and scanning speed is necessary to achieve high quality micro-grooves.


Photonics ◽  
2021 ◽  
Vol 8 (9) ◽  
pp. 387
Author(s):  
Luka Černe ◽  
Jaka Petelin ◽  
Rok Petkovšek

In this manuscript, an implementation of a tunable nonlinear phase compensation method is demonstrated on a typical femtosecond hybrid laser consisting of a fiber pre-amplifier and an additional solid-state amplifier. This enables one to achieve constant laser pulse parameters over a wide range of pulse repetition rates in such a laser. As the gain in the solid-state amplifier is inversely proportional to the input power, the shortfall in the solid-state gain at higher repetition rates must be compensated for with fiber pre-amplifier to ensure constant pulse energy. This increases the accumulated nonlinear phase and consequently alters the laser pulse parameters such as pulse duration and Strehl ratio. To overcome this issue, the nonlinear phase must be compensated for, and what is more it should be compensated for to a different extent at different pulse repetition rates. This is achieved with a tunable CFBG, used also as a pulse stretcher. Using this concept, we demonstrate that constant laser pulse parameters such as pulse energy, pulse duration and Strehl ratio can be achieved in a hybrid laser regardless of the pulse repetition rate.


2021 ◽  
Author(s):  
Gohar Tsakanova ◽  
Elina Arakelova ◽  
Violetta Ayvazyan ◽  
Zaven Karalyan ◽  
Lusine Matevosyan ◽  
...  

Recently, a new technology of low-energy ultrashort-pulsed electron beam (UPEB) accelerators has been developed opening new directions for radiobiology and biomedical research. The purpose of this study was to reveal the lethal dose, LD50 (lethal dose, 50%) delivered by low-energy UPEB whole-body exposure on an organismal level. Wistar rats were exposed to low-energy UPEB whole-body irradiation with different doses and pulse repetition rates to find the LD50 and in silico computer simulations were performed to conduct numerical dose calculations. Survival rate, body weight and water consumption were monitored over the 30-day observation period postirradiation. The LD50 was observed after a 2 Gy dose and pulse repetition rate of 2 Hz. In this group, 50% of the animals survived 30 days postirradiation. The groups of animals exposed to low-energy UPEB radiation at higher doses and pulse repetition rates demonstrated higher mortality rates. We demonstrated that the LD50 dose for the low-energy UPEB whole body irradiation in Wistar rats corresponds to 2 Gy with a pulse repetition rate of 2 Hz. Moreover, we showed that the pulse repetition rate is a very important parameter in the experiments with UPEB and should be assessed in the experiments with such kind of novel irradiation sources.


Sign in / Sign up

Export Citation Format

Share Document