Estimation of Practical Significance for Application of Composite Pipes in Comparison with Metal and Polymer Materials

Author(s):  
Konstantin Strogonov ◽  
Alexander Fedyukhin ◽  
Tatiana Stepanova ◽  
Oleg Derevianko
2014 ◽  
Vol 490-491 ◽  
pp. 34-37
Author(s):  
Xian Wei Wang ◽  
Guang Liang Cheng

In this article should be noted that the accuracy of determining the viscosity of the flow is particularly low in the highly elastic with state of the polymer. It is therefore very important to identity the viscosity of the flow, which has great practical significance. solidity can be changed as a result of intermolecular interaction which can be observed in the process of polymer swelling, which means improving its chain flexibility and lowering the temperature of vitrifying. It should be noted that the processing of the experiment showed no pronounced dependence of the voltage, so it is under-read as the average results for all levers of the stress at a fixed temperature. Processed a method for determining the viscosity of polymer materials, which allows you to divide segmental strength and toughness of the true flow.


Author(s):  
D.T. Grubb

Diffraction studies in polymeric and other beam sensitive materials may bring to mind the many experiments where diffracted intensity has been used as a measure of the electron dose required to destroy fine structure in the TEM. But this paper is concerned with a range of cases where the diffraction pattern itself contains the important information.In the first case, electron diffraction from paraffins, degraded polyethylene and polyethylene single crystals, all the samples are highly ordered, and their crystallographic structure is well known. The diffraction patterns fade on irradiation and may also change considerably in a-spacing, increasing the unit cell volume on irradiation. The effect is large and continuous far C94H190 paraffin and for PE, while for shorter chains to C 28H58 the change is less, levelling off at high dose, Fig.l. It is also found that the change in a-spacing increases at higher dose rates and at higher irradiation temperatures.


Author(s):  
J. Petermann ◽  
G. Broza ◽  
U. Rieck ◽  
A. Jaballah ◽  
A. Kawaguchi

Oriented overgrowth of polymer materials onto ionic crystals is well known and recently it was demonstrated that this epitaxial crystallisation can also occur in polymer/polymer systems, under certain conditions. The morphologies and the resulting physical properties of such systems will be presented, especially the influence of epitaxial interfaces on the adhesion of polymer laminates and the mechanical properties of epitaxially crystallized sandwiched layers.Materials used were polyethylene, PE, Lupolen 6021 DX (HDPE) and 1810 D (LDPE) from BASF AG; polypropylene, PP, (PPN) provided by Höchst AG and polybutene-1, PB-1, Vestolen BT from Chemische Werke Hüls. Thin oriented films were prepared according to the method of Petermann and Gohil, by winding up two different polymer films from two separately heated glass-plates simultaneously with the help of a motor driven cylinder. One double layer was used for TEM investigations, while about 1000 sandwiched layers were taken for mechanical tests.


Author(s):  
J.D. Shelburne ◽  
G.M. Roomans

Proper preparative procedures are a prerequisite for the validity of the results of x-ray microanalysis of biological tissue. Clinical applications of x-ray microanalysis are often concerned with diagnostic problems and the results may have profound practical significance for the patient. From this point of view it is especially important that specimen preparation for clinical applications is carried out correctly.Some clinical problems require very little tissue preparation. Hair, nails, and kidney and gallbladder stones may be examined and analyzed after carbon coating. High levels of zinc or copper in hair may be indicative of dermatological or systemic diseases. Nail clippings may be analyzed (as an alternative to the more conventional sweat test) to confirm a diagnosis of cystic fibrosis. X-ray microanalysis in combination with scanning electron microscopy has been shown to be the most reliable method for the identification of the components of kidney or gallbladder stones.A quantitatively very important clinical application of x-ray microanalysis is the identification and quantification of asbestos and other exogenous particles in lung.


Author(s):  
H.-J. Cantow ◽  
M. Kunz ◽  
M. Möller

In transmission electron microscopy the natural contrast of polymers is very low. Thus the contrast has to be enhanced by staining with heavy metals. The resolution is limited by the size of the staining particles and by the fact that electrons with different energy are focused in different image planes due to the chromatic aberration of the magnetic lenses. The integration of an electron energy loss spectrometer into the optical coloumn of a transmission electron microscope offers the possibility to use monoenergetic electrons and to select electrons with a certain energy for imaging. Thus contrast and resolution are enhanced. By imaging only electrons with an element specific energy loss the element distribution in the sample can be obtained. In addition, elastic bright field images and diffraction patterns yield excellent resolution. Some applications of the method on multicomponent polymer materials are discussed.Bulk polymer samples were prepared by ultramicrotoming at room temperature or well below the glass transition temperature. Very thin films for the direct observation of the structure in semicrystalline polymers were obtained by melt-spinning. Specimens were examined with a ZEISS CEM 902 operated at 80 kV.


Author(s):  
Patricia M. Wilson ◽  
David C. Martin

Efforts in our laboratory and elsewhere have established the utility of low dose high resolution electron microscopy (HREM) for imaging the microstructure of crystalline and liquid crystalline polymers. In a number of polymer systems, direct imaging of the lattice spacings by HREM has provided information about the size, shape, and relative orientation of ordered domains in these materials. However, because of the extent of disorder typical in many polymer microstructures, and because of the sensitivity of most polymer materials to electron beam damage, there have been few studies where the contrast observed in HREM images has been analyzed in a quantitative fashion.Here, we discuss two instances where quantitative information about HREM images has been used to provide new insight about the organization of crystalline polymers in the solid-state. In the first, we study the distortion of the polymer lattice planes near the core of an edge dislocation and compare these results to theories of dislocations in anisotropic and liquid crystalline solids. In the second, we investigate the variations in HREM contrast near the edge of wedge-shaped samples. The polymer used in this study was the diacetylene DCHD, which is stable to electron beam damage (Jc = 20 C/cm2) and highly crystalline. The instrument used in this work was a JEOL 4000 EX HRTEM with a beam blanidng device. More recently, the 4000 EX has been installed with instrumentation for dynamically recording scattered electron beam currents.


2009 ◽  
Vol 14 (4) ◽  
pp. 363-371 ◽  
Author(s):  
Laura Borgogni ◽  
Silvia Dello Russo ◽  
Laura Petitta ◽  
Gary P. Latham

Employees (N = 170) of a City Hall in Italy were administered a questionnaire measuring collective efficacy (CE), perceptions of context (PoC), and organizational commitment (OC). Two facets of collective efficacy were identified, namely group and organizational. Structural equation models revealed that perceptions of top management display a stronger relationship with organizational collective efficacy, whereas employees’ perceptions of their colleagues and their direct superior are related to collective efficacy at the group level. Group collective efficacy had a stronger relationship with affective organizational commitment than did organizational collective efficacy. The theoretical significance of this study is in showing that CE is two-dimensional rather than unidimensional. The practical significance of this finding is that the PoC model provides a framework that public sector managers can use to increase the efficacy of the organization as a whole as well as the individual groups that compose it.


1973 ◽  
Vol 29 (01) ◽  
pp. 183-189
Author(s):  
C. A Praga ◽  
E. M Pogliani

SummaryTemperature represents a very important variable in ADP-induced platelet aggregation.When low doses of ADP ( < 1 (μM) are used to induce platelet aggregation, the length of the incubation period of PRP in the cuvette holder of the aggregometer, thermostatted at 37° C, is very critical. Samples of the same PRP previously kept at room temperature, were incubated for increasing periods of time in the cuvette of the aggregometer before adding ADP, and a significant decrease of aggregation, proportional to the length of incubation, was observed. Stirring of the PRP during the incubation period made these changes more evident.To measure the exact temperature of the PRP during incubation in the aggre- gometer, a thermocouple device was used. While the temperature of the cuvette holder was stable at 37° C, the PRP temperature itself increased exponentially, taking about ten minutes from the beginning of the incubation to reach the value of 37° C. The above results have a practical significance in the reproducibility of the platelet aggregation test in vitro and acquire particular value when the effect of inhibitors of ADP induced platelet aggregation is studied.Experiments carried out with three anti-aggregating agents (acetyl salicyclic acid, dipyridamole and metergoline) have shown that the incubation conditions which influence both the effect of the drugs on platelets and the ADP breakdown in plasma must be strictly controlled.


Sign in / Sign up

Export Citation Format

Share Document