Using two novel integrated systems to cool the air toward the ISO condition at the gas turbine inlet

Energy ◽  
2021 ◽  
pp. 122724
Author(s):  
Mehran Nematollahi ◽  
Soheil Porkhial ◽  
Madjid Ghodsi Hassanabad
Author(s):  
Hai Zhang ◽  
Qun Zheng ◽  
Mustapha Chaker ◽  
Cyrus Meher-Homji

The air pressure drop over the nozzles manifolds of inlet fogging system and the flow resistance downstream of the nozzle array (manifold) have always been an area of concern and is the object of this paper. Fogging nozzles arrays (involving several hundred nozzles) are mounted on channels and beams, downstream of the inlet filters and affect the pressure drop. The water injection angle, nozzle injection velocities and the progressive evaporation of the water droplets evaporation all influence the inlet pressure seen at the gas turbine inlet. This paper focuses on a numerical simulation investigation of flow resistance (pressure drop) of inlet fogging systems. In this research effort, the inlet duct is meshed in order to compute the pressure drop over the nozzles frames in fogging and non-fogging conditions. First, the resistance coefficients of an air intake filter are obtained by numerical and experimental methods, and then the coefficients are used for the simulation of the inlet duct by considering the filter as a porous media. Effects of nozzle spread pattern and water injection pattern are then modeled. The results indicate that injection velocity and arrangement of nozzles could have significant effects on the pressure drop and intake distortion, which will affect compressor performance. This paper provides a comprehensive analysis of the pressure drop and evaporation of inlet fogging and will be of value to gas turbine inlet fogging system designers and users.


Author(s):  
Daniel E. Caguiat

The Naval Surface Warfare Center, Carderock Division (NSWCCD) Gas Turbine Emerging Technologies Code 9334 was tasked by NSWCCD Shipboard Energy Office Code 859 to research and evaluate fouling resistant compressor coatings for Rolls Royce Allison 501-K Series gas turbines. The objective of these tests was to investigate the feasibility of reducing the rate of compressor fouling degradation and associated rate of specific fuel consumption (SFC) increase through the application of anti-fouling coatings. Code 9334 conducted a market investigation and selected coatings that best fit the test objective. The coatings selected were Sermalon for compressor stages 1 and 2 and Sermaflow S4000 for the remaining 12 compressor stages. Both coatings are manufactured by Sermatech International, are intended to substantially decrease blade surface roughness, have inert top layers, and contain an anti-corrosive aluminum-ceramic base coat. Sermalon contains a Polytetrafluoroethylene (PTFE) topcoat, a substance similar to Teflon, for added fouling resistance. Tests were conducted at the Philadelphia Land Based Engineering Site (LBES). Testing was first performed on the existing LBES 501-K17 gas turbine, which had a non-coated compressor. The compressor was then replaced by a coated compressor and the test was repeated. The test plan consisted of injecting a known amount of salt solution into the gas turbine inlet while gathering compressor performance degradation and fuel economy data for 0, 500, 1000, and 1250 KW generator load levels. This method facilitated a direct comparison of compressor degradation trends for the coated and non-coated compressors operating with the same turbine section, thereby reducing the number of variables involved. The collected data for turbine inlet, temperature, compressor efficiency, and fuel consumption were plotted as a percentage of the baseline conditions for each compressor. The results of each plot show a decrease in the rates of compressor degradation and SFC increase for the coated compressor compared to the non-coated compressor. Overall test results show that it is feasible to utilize anti-fouling compressor coatings to reduce the rate of specific fuel consumption increase associated with compressor performance degradation.


Author(s):  
Terry B. Sullivan ◽  
Michael Giampetro

This paper provides comprehensive methodology on testing inlet chiller systems that are used for Gas Turbine Inlet Air Conditioning. It will serve as a guiding document for the Inlet Chiller Project Team formed by PTC 51, “Combustion Turbine Inlet Air Conditioning Equipment” for use in scripting that code’s section on Inlet Chiller Performance Testing. This paper shows the conceptual similarities that can be drawn between inlet chiller and overall plant performance testing, as well as detailing the pertinent test scopes and boundaries, identifying expected test objectives, and listing the applicable test boundary parameters to be used for correction. Addressing an industry need, this paper also offers guidance on testing these components / systems at conditions different than design. Current equipment code committees, such as ASME PTC 22 on Gas Turbines, and ASME PTC 46 on Overall Plant Performance Testing, have concluded that inlet air conditioning equipment must be out of service while testing the major plant equipment. This would require the inlet chilling system to be tested separately. This requirement dictates that a technically-sound method of inlet chiller testing be codified in a timely manner.


Author(s):  
M. W. Horner ◽  
A. Caruvana

Final component and technology verification tests have been completed for application to a 2600°F rotor inlet temperature gas turbine. These tests have proven the capability of combustor, turbine hot section, and IGCC fuel systems and controls to operate in a combined cycle plant burning a coal-derived gas fuel at elevated gas turbine inlet temperatures (2600–3000°F). This paper presents recent test results and summarizes the overall progress made during the DOE-HTTT Phase II program.


Author(s):  
Weimar Mantilla ◽  
José García ◽  
Rafael Guédez ◽  
Alessandro Sorce

Abstract Under new scenarios with high shares of variable renewable electricity, combined cycle gas turbines (CCGT) are required to improve their flexibility, in terms of ramping capabilities and part-load efficiency, to help balance the power system. Simultaneously, liberalization of electricity markets and the complexity of its hourly price dynamics are affecting the CCGT profitability, leading the need for optimizing its operation. Among the different possibilities to enhance the power plant performance, an inlet air conditioning unit (ICU) offers the benefit of power augmentation and “minimum environmental load” (MEL) reduction by controlling the gas turbine inlet temperature using cold thermal energy storage and a heat pump. Consequently, an evaluation of a CCGT integrated with this inlet conditioning unit including a day-ahead optimized operation strategy was developed in this study. To establish the hourly dispatch of the power plant and the operation mode of the inlet conditioning unit to either cool down or heat up the gas turbine inlet air, a mixed-integer linear optimization (MILP) was formulated using MATLAB, aiming to maximize the operational profit of the plant within a 24-hours horizon. To assess the impact of the proposed unit operating under this dispatch strategy, historical data of electricity and natural gas prices, as well as meteorological data and CO2 emission allowances price, have been used to perform annual simulations of a reference power plant located in Turin, Italy. Furthermore, different equipment capacities and parameters have been investigated to identify trends of the power plant performance. Lastly, a sensitivity analysis on market conditions to test the control strategy response was also considered. Results indicate that the inlet conditioning unit, together with the dispatch optimization, increases the power plant’s operational profit by achieving a wider operational range, particularly important during peak and off-peak periods. For the specific case study, it is estimated that the net present value of the CCGT integrated with the ICU is 0.5% higher than the power plant without the unit. In terms of technical performance, results show that the unit reduces the minimum environmental load by approximately 1.34% and can increase the net power output by 0.17% annually.


1968 ◽  
Vol 72 (696) ◽  
pp. 1087-1094 ◽  
Author(s):  
F. J. Bayley ◽  
A. B. Turner

It is well known that the performance of the practical gas turbine cycle, in which compression and expansion are non-isentropic, is critically dependent upon the maximum temperature of the working fluid. In engines in which shaft-power is produced the thermal efficiency and the specific power output rise steadily as the turbine inlet temperature is increased. In jet engines, in which the gas turbine has so far found its greatest success, similar advantages of high temperature operation accrue, more particularly as aircraft speeds increase to utilise the higher resultant jet velocities. Even in high by-pass ratio engines, designed specifically to reduce jet efflux velocities for application to lower speed aircraft, overall engine performance responds very favourably to increased turbine inlet temperatures, in which, moreover, these more severe operating conditions apply continuously during flight, and not only at maximum power as with more conventional cycles.


2007 ◽  
Vol 31 (13) ◽  
pp. 1292-1306 ◽  
Author(s):  
Galal M. Zaki ◽  
Rahim K. Jassim ◽  
Majed M. Alhazmy

Author(s):  
A. W. Reichert ◽  
M. Janssen

Siemens heavy duty Gas Turbines have been well known for their high power output combined with high efficiency and reliability for more than 3 decades. Offering state of the art technology at all times, the requirements concerning the cooling and sealing air system have increased with technological development over the years. In particular the increase of the turbine inlet temperature and reduced NOx requirements demand a highly efficient cooling and sealing air system. The new Vx4.3A family of Siemens gas turbines with ISO turbine inlet temperatures of 1190°C in the power range of 70 to 240 MW uses an effective film cooling technique for the turbine stages 1 and 2 to ensure the minimum cooling air requirement possible. In addition, the application of film cooling enables the cooling system to be simplified. For example, in the new gas turbine family no intercooler and no cooling air booster for the first turbine vane are needed. This paper deals with the internal air system of Siemens gas turbines which supplies cooling and sealing air. A general overview is given and some problems and their technical solutions are discussed. Furthermore a state of the art calculation system for the prediction of the thermodynamic states of the cooling and sealing air is introduced. The calculation system is based on the flow calculation package Flowmaster (Flowmaster International Ltd.), which has been modified for the requirements of the internal air system. The comparison of computational results with measurements give a good impression of the high accuracy of the calculation method used.


Author(s):  
Katsuyoshi Tada ◽  
Kei Inoue ◽  
Tomo Kawakami ◽  
Keijiro Saitoh ◽  
Satoshi Tanimura

Gas-turbine combined-cycle (GTCC) power generation is clean and efficient, and its demand will increase in the future from economic and social perspectives. Raising turbine inlet temperature is an effective way to increase combined cycle efficiency and contributes to global environmental conservation by reducing CO2 emissions and preventing global warming. However, increasing turbine inlet temperature can lead to the increase of NOx emissions, depletion of the ozone layer and generation of photochemical smog. To deal with this issue, MHPS (MITSUBISHI HITACHI POWER SYSTEMS) and MHI (MITSUBISHI HEAVY INDUSTRIES) have developed Dry Low NOx (DLN) combustion techniques for high temperature gas turbines. In addition, fuel flexibility is one of the most important features for DLN combustors to meet the requirement of the gas turbine market. MHPS and MHI have demonstrated DLN combustor fuel flexibility with natural gas (NG) fuels that have a large Wobbe Index variation, a Hydrogen-NG mixture, and crude oils.


Sign in / Sign up

Export Citation Format

Share Document