scholarly journals Simple lysis of bacterial cells for DNA-based diagnostics using hydrophilic ionic liquids

2019 ◽  
Vol 9 (1) ◽  
Author(s):  
Roland Martzy ◽  
Katharina Bica-Schröder ◽  
Ádám Márk Pálvölgyi ◽  
Claudia Kolm ◽  
Stefan Jakwerth ◽  
...  

Abstract The extraction of nucleic acids from microorganisms for subsequent molecular diagnostic applications is still a tedious and time-consuming procedure. We developed a method for the rapid preparation of genomic DNA from bacteria based on hydrophilic ionic liquids (ILs). First, we tested eight ILs in different buffer systems for their inhibitory effects on quantitative PCR. The cell lysis potential of different IL/buffer combinations was assessed by application on Enterococcus faecalis as a model organism for Gram-positive bacteria. The two best ILs, choline hexanoate and 1-ethyl-3-methylimidazolium acetate, were compared with the reference enzymatic method and two commercial DNA extraction kits. All methods were evaluated on four Gram-positive and four Gram-negative bacterial species that are highly relevant for environmental, food, or clinical diagnostics. In comparison to the reference method, extraction yields of the IL-based procedure were within one order of magnitude for most of the strains. The final protocol for DNA extraction using the two ILs is very low-cost, avoids the use of hazardous chemicals and can be performed in five minutes on a simple heating block. This makes the method ideal for high sample throughput and offers the opportunity for DNA extraction from bacteria in resource-limited settings or even in the field.

2020 ◽  
Vol 13 (10) ◽  
pp. 2243-2251
Author(s):  
Azhar G. Shalaby ◽  
Neveen R. Bakry ◽  
Abeer A. E. Mohamed ◽  
Ashraf A. Khalil

Background and Aim: Flinders Technology Associates (FTA) cards simplify sample storage, transport, and extraction by reducing cost and time for diagnosis. This study evaluated the FTA suitability for safe transport and storage of Gram-positive and Gram-negative bacterial cells of animal origin on its liquid culture form and from organ impression smears (tissues) under the same routine condition of microbiological laboratory along with detecting their nucleic acid over different storage conditions. Materials and Methods: Increase in bacterial count from 104 to 107 (colony-forming units/mL) of 78 isolates representing seven bacterial species was applied onto cards. FTA cards were grouped and inoculated by these bacteria and then stored at different conditions of 24-27°C, 4°C, and –20°C for 24 h, for 2 weeks, for 1 and 3 month storage, respectively. Bacteriological examination was done, after which bacterial DNA was identified using specific primers for each bacterial type and detected by polymerase chain reaction (PCR). Results: The total percentage of recovered bacteria from FTA cards was 66.7% at 24-27–C for 24 h, the detection limit was 100% in Gram-positive species, while it was 57.4% in Gram-negative ones. Regarding viable cell detection from organ impression smears, it was successful under the previous conditions. No live bacterial cells were observed by bacteriological isolation rather than only at 24-27°C for 24 h storage. All bacterial DNA were sufficiently confirmed by the PCR technique at different conditions. Conclusion: Overall, the FTA card method was observed to be a valid tool for nucleic acid purification for bacteria of animal origin in the form of culture or organ smears regardless of its Gram type and is used for a short time only 24 h for storage and transport of live bacteria specifically Gram-positive type. Moreover, the bacterial nucleic acid was intact after storage in –20°C for 3 months and was PCR amplifiable.


Micromachines ◽  
2019 ◽  
Vol 10 (8) ◽  
pp. 537 ◽  
Author(s):  
Cancan Zhu ◽  
Anzhong Hu ◽  
Junsheng Cui ◽  
Ke Yang ◽  
Xinchao Zhu ◽  
...  

Point-of-care (POC) molecular diagnostics play a crucial role in the prevention and treatment of infectious diseases. It is necessary to develop portable, easy-to-use, inexpensive and rapid molecular diagnostic tools. In this study, we proposed a lab-on-a-chip device that integrated DNA extraction, solid-phase PCR and genotyping detection. The ingenious design of the pneumatic microvalves enabled the fluid mixing and reagent storage to be organically combined, significantly reducing the size of the chip. The solid oligonucleotide array incorporated into the chip allowed the spatial separation of the primers and minimized undesirable interactions in multiplex amplification. As a proof-of-concept for POC molecular diagnostics on the device, five genotypes of high-risk human papillomavirus (HPV) (HPV16/HPV18/HPV31/HPV33/HPV58) were examined. Positive quality control samples and HPV patient cervical swab specimens were analyzed on the integrated microdevice. The platform was capable of detection approximately 50 copies of HPV virus per reaction during a single step, including DNA extraction, solid-phase PCR and genotype detection, in 1 h from samples being added to the chip. This simple and inexpensive microdevice provided great utility for the screening and monitoring of HPV genotypes. The sample-to-result platform will pave the way for wider application of POC molecular testing in the fields of clinical diagnostics, food safety, and environmental monitoring.


2019 ◽  
Vol 15 (7) ◽  
pp. 1598-1608
Author(s):  
Hongna Liu ◽  
Kathryn Heflin ◽  
Jian Han ◽  
Matt Conover ◽  
Leslie Wagner ◽  
...  

We utilized Amplicon-Rescue Multiplex PCR (ARM-PCR) and microarray hybridization to develop and validate the iC-GPC Assay, a multiplexed, in vitro diagnostic test that identifies five of the most common gram positive bacteria and three clinically relevant resistance markers associated with bloodstream infections (BSI). The iC-GPC Assay is designed for use with the iC-System™, which automates sample preparation, ARM-PCR, and microarray detection within a closed cassette. Herein, we determined the limit of detection for each of the iC-GPC Assay targets to be between 3.0 × 105–1.7 × 107 CFU/mL, well below clinically relevant bacterial levels for positive blood cultures. Additionally, we tested 106 strains for assay inclusivity and observed a target performance of 99.4%. 95 of 96 non-target organisms tested negative for cross-reactivity, thereby assuring a high level of assay specificity. Overall performance above 99% was observed for iC-GPC Assay reproducibility studies across multiple sites, operators and cassette lots. In conclusion, the iC-GPC Assay is capable of accurately and rapidly identifying bacterial species and resistance determinants present in blood cultures containing gram positive bacteria. Utilizing molecular diagnostics like the iC-GPC Assay will decrease time to treatment, healthcare costs, and BSI-related mortality.


2020 ◽  
Vol 48 (5) ◽  
pp. 030006052092559
Author(s):  
Xiaolan Li ◽  
Caroline J. Bosch-Tijhof ◽  
Xi Wei ◽  
Johannes J. de Soet ◽  
Wim Crielaard ◽  
...  

Objective Clinical diagnostics often requires the detection of multiple bacterial species in limited clinical samples with a single DNA extraction method. This study aimed to compare the bacterial DNA extraction efficiency of two lysis methods automated with the MagNA-Pure LC instrument. The samples included five oral bacterial species (three Gram-positive and two Gram-negative) with or without human saliva background. Methods Genomic DNA (gDNA) was extracted from bacterial cultures by bead-beating lysis (BMP) or chemical lysis (MP), followed by automated purification and measurement by quantitative PCR. Results For pure bacterial cultures, the MP method yielded higher quantities of extracted DNA and a lower detection limit than the BMP method, except where the samples contained high numbers of Gram-positive bacteria. For bacterial cultures with a saliva background, no difference in gDNA extraction efficacy was observed between the two methods. Conclusions The efficiency of a bacterial DNA extraction method is not only affected by the bacterial cell wall structure but also by the sample milieu. The MP method provided superior gDNA extraction efficiency when the samples contained a single bacterial species, whereas either of the BMP and MP methods could be applied with similar efficiencies to samples containing multiple species of bacteria.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
B. Indu ◽  
Tallapragada Keertana ◽  
Sahu Ipsita ◽  
Uppada Jagadeeshwari ◽  
Chintalapati Sasikala ◽  
...  

AbstractOur major concern was to address “yeast endobacteria” which was based on a few reports in the recent past where bacteria may find yeast as a niche for survival. In this study, we report the microbiota of twenty-nine axenic yeast cultures recovered from different habitats based on their 16S rRNA gene-amplicon metagenomes. Yeasts were identified based on D1/D2 or ITS gene sequences. Bacterial diversity was widespread, varied and rich among all yeasts except for four strains. Taxa belonging to the phylum Firmicutes, Proteobacteria, Actinobacteria and Bacteroidetes and the genera; Streptococcus, Propionibacterium were common to all the yeasts. Candida tropicalis was used as a model organism to confirm bacteria through fluorescence in situ hybridization (FISH), isolating and re-introducing the isolated bacteria into the yeast. FISH analysis confirmed the endobacteria of C. tropicalis and we have successfully isolated four bacteria only after lysis and disruption of yeast cells. These bacteria were identified as species of Pseudomonas, Chryseobacterium, Lysinibacillus and Propionibacterium. Guestimates indicate 95% of bacterial species of C. tropicalis are yet-to-be-cultivated. We have successfully reintroduced mCherry tagged Pseudomonas into C. tropicalis. Also, auto-fluorescent Prochlorococcus and Rhodopseudomonas could be introduced into C. tropicalis while mCherry tagged E. coli or Salmonella could not be introduced. FISH analysis confirmed the presence of both native and infected bacterial cells present in C. tropicalis. Our findings unveil the insights into the ghost microbiota associated with yeast, which otherwise are considered to be axenic cultures. Their inherent occurrence, together with co-cultivation experiments under laboratory conditions suggests that yeasts are a thriving hub for bacterial communities.


2020 ◽  
Vol 17 (4) ◽  
pp. 498-506 ◽  
Author(s):  
Pavan K. Mujawdiya ◽  
Suman Kapur

: Quorum Sensing (QS) is a phenomenon in which bacterial cells communicate with each other with the help of several low molecular weight compounds. QS is largely dependent on population density, and it triggers when the concentration of quorum sensing molecules accumulate in the environment and crosses a particular threshold. Once a certain population density is achieved and the concentration of molecules crosses a threshold, the bacterial cells show a collective behavior in response to various chemical stimuli referred to as “auto-inducers”. The QS signaling is crucial for several phenotypic characteristics responsible for bacterial survival such as motility, virulence, and biofilm formation. Biofilm formation is also responsible for making bacterial cells resistant to antibiotics. : The human gut is home to trillions of bacterial cells collectively called “gut microbiota” or “gut microbes”. Gut microbes are a consortium of more than 15,000 bacterial species and play a very crucial role in several body functions such as metabolism, development and maturation of the immune system, and the synthesis of several essential vitamins. Due to its critical role in shaping human survival and its modulating impact on body metabolisms, the gut microbial community has been referred to as “the forgotten organ” by O`Hara et al. (2006) [1]. Several studies have demonstrated that chemical interaction between the members of bacterial cells in the gut is responsible for shaping the overall microbial community. : Recent advances in phytochemical research have generated a lot of interest in finding new, effective, and safer alternatives to modern chemical-based medicines. In the context of antimicrobial research various plant extracts have been identified with Quorum Sensing Inhibitory (QSI) activities among bacterial cells. This review focuses on the mechanism of quorum sensing and quorum sensing inhibitors isolated from natural sources.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Kathy E. Raven ◽  
Sophia T. Girgis ◽  
Asha Akram ◽  
Beth Blane ◽  
Danielle Leek ◽  
...  

AbstractWhole-genome sequencing is likely to become increasingly used by local clinical microbiology laboratories, where sequencing volume is low compared with national reference laboratories. Here, we describe a universal protocol for simultaneous DNA extraction and sequencing of numerous different bacterial species, allowing mixed species sequence runs to meet variable laboratory demand. We assembled test panels representing 20 clinically relevant bacterial species. The DNA extraction process used the QIAamp mini DNA kit, to which different combinations of reagents were added. Thereafter, a common protocol was used for library preparation and sequencing. The addition of lysostaphin, lysozyme or buffer ATL (a tissue lysis buffer) alone did not produce sufficient DNA for library preparation across the species tested. By contrast, lysozyme plus lysostaphin produced sufficient DNA across all 20 species. DNA from 15 of 20 species could be extracted from a 24-h culture plate, while the remainder required 48–72 h. The process demonstrated 100% reproducibility. Sequencing of the resulting DNA was used to recapitulate previous findings for species, outbreak detection, antimicrobial resistance gene detection and capsular type. This single protocol for simultaneous processing and sequencing of multiple bacterial species supports low volume and rapid turnaround time by local clinical microbiology laboratories.


2009 ◽  
Vol 9 (23) ◽  
pp. 9281-9297 ◽  
Author(s):  
S. M. Burrows ◽  
T. Butler ◽  
P. Jöckel ◽  
H. Tost ◽  
A. Kerkweg ◽  
...  

Abstract. Bacteria are constantly being transported through the atmosphere, which may have implications for human health, agriculture, cloud formation, and the dispersal of bacterial species. We simulate the global transport of bacteria, represented as 1 μm and 3 μm diameter spherical solid particle tracers in a general circulation model. We investigate factors influencing residence time and distribution of the particles, including emission region, cloud condensation nucleus activity and removal by ice-phase precipitation. The global distribution depends strongly on the assumptions made about uptake into cloud droplets and ice. The transport is also affected, to a lesser extent, by the emission region, particulate diameter, and season. We find that the seasonal variation in atmospheric residence time is insufficient to explain by itself the observed seasonal variation in concentrations of particulate airborne culturable bacteria, indicating that this variability is mainly driven by seasonal variations in culturability and/or emission strength. We examine the potential for exchange of bacteria between ecosystems and obtain rough estimates of the flux from each ecosystem by using a maximum likelihood estimation technique, together with a new compilation of available observations described in a companion paper. Globally, we estimate the total emissions of bacteria-containing particles to the atmosphere to be 7.6×1023–3.5×1024 a−1, originating mainly from grasslands, shrubs and crops. We estimate the mass of emitted bacteria- to be 40–1800 Gg a−1, depending on the mass fraction of bacterial cells in the particles. In order to improve understanding of this topic, more measurements of the bacterial content of the air and of the rate of surface-atmosphere exchange of bacteria will be necessary. Future observations in wetlands, hot deserts, tundra, remote glacial and coastal regions and over oceans will be of particular interest.


Diagnostics ◽  
2021 ◽  
Vol 11 (2) ◽  
pp. 349
Author(s):  
Sien Ombelet ◽  
Alessandra Natale ◽  
Jean-Baptiste Ronat ◽  
Olivier Vandenberg ◽  
Liselotte Hardy ◽  
...  

Bacterial identification is challenging in low-resource settings (LRS). We evaluated the MicroScan identification panels (Beckman Coulter, Brea, CA, USA) as part of Médecins Sans Frontières’ Mini-lab Project. The MicroScan Dried Overnight Positive ID Type 3 (PID3) panels for Gram-positive organisms and Dried Overnight Negative ID Type 2 (NID2) panels for Gram-negative organisms were assessed with 367 clinical isolates from LRS. Robustness was studied by inoculating Gram-negative species on the Gram-positive panel and vice versa. The ease of use of the panels and readability of the instructions for use (IFU) were evaluated. Of species represented in the MicroScan database, 94.6% (185/195) of Gram-negative and 85.9% (110/128) of Gram-positive isolates were correctly identified up to species level. Of species not represented in the database (e.g., Streptococcus suis and Bacillus spp.), 53.1% out of 49 isolates were incorrectly identified as non-related bacterial species. Testing of Gram-positive isolates on Gram-negative panels and vice versa (n = 144) resulted in incorrect identifications for 38.2% of tested isolates. The readability level of the IFU was considered too high for LRS. Inoculation of the panels was favorably evaluated, whereas the visual reading of the panels was considered error-prone. In conclusion, the accuracy of the MicroScan identification panels was excellent for Gram-negative species and good for Gram-positive species. Improvements in stability, robustness, and ease of use have been identified to assure adaptation to LRS constraints.


Antibiotics ◽  
2021 ◽  
Vol 10 (3) ◽  
pp. 341
Author(s):  
Katharina Hoenes ◽  
Richard Bauer ◽  
Barbara Spellerberg ◽  
Martin Hessling

Interest in visible light irradiation as a microbial inactivation method has widely increased due to multiple possible applications. Resistance development is considered unlikely, because of the multi-target mechanism, based on the induction of reactive oxygen species by wavelength specific photosensitizers. However, the affected targets are still not completely identified. We investigated membrane integrity with the fluorescence staining kit LIVE/DEAD® BacLight™ on a Gram positive and a Gram negative bacterial species, irradiating Staphylococcus carnosus and Pseudomonas fluorescens with 405 nm and 450 nm. To exclude the generation of viable but nonculturable (VBNC) bacterial cells, we applied an ATP test, measuring the loss of vitality. Pronounced uptake of propidium iodide was only observed in Pseudomonas fluorescens at 405 nm. Transmission electron micrographs revealed no obvious differences between irradiated samples and controls, especially no indication of an increased bacterial cell lysis could be observed. Based on our results and previous literature, we suggest that visible light photoinactivation does not lead to rapid bacterial cell lysis or disruption. However, functional loss of membrane integrity due to depolarization or inactivation of membrane proteins may occur. Decomposition of the bacterial envelope following cell death might be responsible for observations of intracellular component leakage.


Sign in / Sign up

Export Citation Format

Share Document