scholarly journals Picosecond multilevel resistive switching in tantalum oxide thin films

2020 ◽  
Vol 10 (1) ◽  
Author(s):  
Ulrich Böttger ◽  
Moritz von Witzleben ◽  
Viktor Havel ◽  
Karsten Fleck ◽  
Vikas Rana ◽  
...  

Abstract The increasing demand for high-density data storage leads to an increasing interest in novel memory concepts with high scalability and the opportunity of storing multiple bits in one cell. A promising candidate is the redox-based resistive switch repositing the information in form of different resistance states. For reliable programming, the underlying physical parameters need to be understood. We reveal that the programmable resistance states are linked to internal series resistances and the fundamental nonlinear switching kinetics. The switching kinetics of $$\hbox {Ta}_2 \hbox {O}_5$$ Ta 2 O 5 -based cells was investigated in a wide range over 15 orders of magnitude from 10$$^5$$ 5  s to 250 ps. The capacitive charging time of our device limits the direct observation of the set time below 770 ps, however, we found indication for an intrinsic switching speed of 10 ps at a stimulus of 3 V. On all time scales, multi-bit data storage capabilities were demonstrated. The elucidated link between fundamental material properties and multi-bit data storage paves the way for designing resistive switches for memory and neuromorphic applications.

Diabetes ◽  
1991 ◽  
Vol 40 (5) ◽  
pp. 628-632 ◽  
Author(s):  
I. Jensen ◽  
V. Kruse ◽  
U. D. Larsen

2021 ◽  
Vol 413 (9) ◽  
pp. 2389-2406 ◽  
Author(s):  
Soumyabrata Banik ◽  
Sindhoora Kaniyala Melanthota ◽  
Arbaaz ◽  
Joel Markus Vaz ◽  
Vishak Madhwaraj Kadambalithaya ◽  
...  

AbstractSmartphone-based imaging devices (SIDs) have shown to be versatile and have a wide range of biomedical applications. With the increasing demand for high-quality medical services, technological interventions such as portable devices that can be used in remote and resource-less conditions and have an impact on quantity and quality of care. Additionally, smartphone-based devices have shown their application in the field of teleimaging, food technology, education, etc. Depending on the application and imaging capability required, the optical arrangement of the SID varies which enables them to be used in multiple setups like bright-field, fluorescence, dark-field, and multiple arrays with certain changes in their optics and illumination. This comprehensive review discusses the numerous applications and development of SIDs towards histopathological examination, detection of bacteria and viruses, food technology, and routine diagnosis. Smartphone-based devices are complemented with deep learning methods to further increase the efficiency of the devices.


Sensors ◽  
2021 ◽  
Vol 21 (13) ◽  
pp. 4459
Author(s):  
José R. González ◽  
Charbel Damião ◽  
Maira Moran ◽  
Cristina A. Pantaleão ◽  
Rubens A. Cruz ◽  
...  

According to experts and medical literature, healthy thyroids and thyroids containing benign nodules tend to be less inflamed and less active than those with malignant nodules. It seems to be a consensus that malignant nodules have more blood veins and more blood circulation. This may be related to the maintenance of the nodule’s heat at a higher level compared with neighboring tissues. If the internal heat modifies the skin radiation, then it could be detected by infrared sensors. The goal of this work is the investigation of the factors that allow this detection, and the possible relation with any pattern referent to nodule malignancy. We aim to consider a wide range of factors, so a great number of numerical simulations of the heat transfer in the region under analysis, based on the Finite Element method, are performed to study the influence of each nodule and patient characteristics on the infrared sensor acquisition. To do so, the protocol for infrared thyroid examination used in our university’s hospital is simulated in the numerical study. This protocol presents two phases. In the first one, the body under observation is in steady state. In the second one, it is submitted to thermal stress (transient state). Both are simulated in order to verify if it is possible (by infrared sensors) to identify different behavior referent to malignant nodules. Moreover, when the simulation indicates possible important aspects, patients with and without similar characteristics are examined to confirm such influences. The results show that the tissues between skin and thyroid, as well as the nodule size, have an influence on superficial temperatures. Other thermal parameters of thyroid nodules show little influence on surface infrared emissions, for instance, those related to the vascularization of the nodule. All details of the physical parameters used in the simulations, characteristics of the real nodules and thermal examinations are publicly available, allowing these simulations to be compared with other types of heat transfer solutions and infrared examination protocols. Among the main contributions of this work, we highlight the simulation of the possible range of parameters, and definition of the simulation approach for mapping the used infrared protocol, promoting the investigation of a possible relation between the heat transfer process and the data obtained by infrared acquisitions.


2021 ◽  
Vol 504 (2) ◽  
pp. 2325-2345
Author(s):  
Emanuel Sillero ◽  
Patricia B Tissera ◽  
Diego G Lambas ◽  
Stefano Bovino ◽  
Dominik R Schleicher ◽  
...  

ABSTRACT We present p-gadget3-k, an updated version of gadget-3, that incorporates the chemistry package krome. p-gadget3-k follows the hydrodynamical and chemical evolution of cosmic structures, incorporating the chemistry and cooling of H2 and metal cooling in non-equilibrium. We performed different runs of the same ICs to assess the impact of various physical parameters and prescriptions, namely gas metallicity, molecular hydrogen formation on dust, star formation recipes including or not H2 dependence, and the effects of numerical resolution. We find that the characteristics of the simulated systems, both globally and at kpc-scales, are in good agreement with several observable properties of molecular gas in star-forming galaxies. The surface density profiles of star formation rate (SFR) and H2 are found to vary with the clumping factor and resolution. In agreement with previous results, the chemical enrichment of the gas component is found to be a key ingredient to model the formation and distribution of H2 as a function of gas density and temperature. A star formation algorithm that takes into account the H2 fraction together with a treatment for the local stellar radiation field improves the agreement with observed H2 abundances over a wide range of gas densities and with the molecular Kennicutt–Schmidt law, implying a more realistic modelling of the star formation process.


2009 ◽  
Vol 1157 ◽  
Author(s):  
Shantanu Tripathi ◽  
Fiona M. Doyle ◽  
David A. Dornfeld

AbstractDuring copper CMP, abrasives and asperities interact with the copper at the nano-scale, partially removing protective films. The local Cu oxidation rate increases, then decays with time as the protective film reforms. In order to estimate the copper removal rate and other Cu-CMP output parameters with a mechanistic model, the passivation kinetics of Cu, i.e. the decay of the oxidation current with time after an abrasive/copper interaction, are needed. For the first time in studying Cu-CMP, microelectrodes were used to reduce interference from capacitive charging, IR drops and low diffusion limited currents, problems typical with traditional macroelectrodes. Electrochemical impedance spectroscopy (EIS) was used to obtain the equivalent circuit elements associated with different electrochemical phenomena (capacitive, kinetics, diffusion etc.) at different polarization potentials. These circuit elements were used to interpret potential-step chronoamperometry results in inhibiting and passivating solutions, notably to distinguish between capacitive charging and Faradaic currents.Chronoamperometry of Cu in acidic aqueous glycine solution containing the corrosion inhibitor benzotriazole (BTA) displayed a very consistent current decay behavior at all potentials, indicating that the rate of current decay was controlled by diffusion of BTA to the surface. In basic aqueous glycine solution, Cu (which undergoes passivation by a mechanism similar to that operating in weakly acidic hydrogen peroxide slurries) displayed similar chronoamperometric behavior for the first second or so at all anodic potentials. Thereafter, the current densities at active potentials settled to values around those expected from polarization curves, whereas the current densities at passive potentials continued to decline. Oxidized Cu species typically formed at ‘active’ potentials were found to cause significant current decay at active potentials and at passive potentials before more protective passive films form. This was established from galvanostatic experiments.


2017 ◽  
Vol 114 (31) ◽  
pp. 8265-8270 ◽  
Author(s):  
Simon Olsson ◽  
Hao Wu ◽  
Fabian Paul ◽  
Cecilia Clementi ◽  
Frank Noé

Accurate mechanistic description of structural changes in biomolecules is an increasingly important topic in structural and chemical biology. Markov models have emerged as a powerful way to approximate the molecular kinetics of large biomolecules while keeping full structural resolution in a divide-and-conquer fashion. However, the accuracy of these models is limited by that of the force fields used to generate the underlying molecular dynamics (MD) simulation data. Whereas the quality of classical MD force fields has improved significantly in recent years, remaining errors in the Boltzmann weights are still on the order of a few kT, which may lead to significant discrepancies when comparing to experimentally measured rates or state populations. Here we take the view that simulations using a sufficiently good force-field sample conformations that are valid but have inaccurate weights, yet these weights may be made accurate by incorporating experimental data a posteriori. To do so, we propose augmented Markov models (AMMs), an approach that combines concepts from probability theory and information theory to consistently treat systematic force-field error and statistical errors in simulation and experiment. Our results demonstrate that AMMs can reconcile conflicting results for protein mechanisms obtained by different force fields and correct for a wide range of stationary and dynamical observables even when only equilibrium measurements are incorporated into the estimation process. This approach constitutes a unique avenue to combine experiment and computation into integrative models of biomolecular structure and dynamics.


2009 ◽  
Vol 15 (S3) ◽  
pp. 53-54
Author(s):  
Aiying Wu ◽  
P. M. Vilarinho

AbstractLead zirconate - lead titanate (PZT) materials are commercially important piezoelectric and ferroelectrics in a wide range of applications, such as data storage (dynamic access and ferroelectric random access memories) and sensing and actuating devices. PZT with the morphotropic phase boundary composition offers the highest piezoelectric response and at the present there are no fullydeveloped alternative materials to PZT. The importance of PZT associated with the continuous requirements of device miniaturization, imposes the development of high quality PZT thin films with optimized properties. Concomitantly due to the dependence of the final properties of thin films on the details of the microstructure a thoroughly analysis at the local scale of their microstructure is necessary. Sol-gel method, is one of the Chemical Solution Deposition techniques used to prepare oxide thin films, such as PZT. Starting from a solution, a solid network is progressively formed via inorganic polymerisation reactions. Most metal alkoxides used for sol-gel synthesis are highly reactive towards hydrolysis and condensation. Therefore their chemical reactivity has to be tailored via the chemical modification (or complexation) of metal alkoxides to avoid uncontrolled reactions and precipitation. For PZT sol gel thin film preparation, two chemical routes are frequently used depending on the nature of the molecular precursor, namely methotoxyethanol (MOE) route and diol-route.


2001 ◽  
Vol 665 ◽  
Author(s):  
Feng Xia ◽  
H.S. Xu ◽  
Babak Razavi ◽  
Q. M. Zhang

ABSTRACTFerroelectric polymer thin films are attractive for a wide range of applications such as MEMS, IR sensors, and memory devices. We present the results of a recent investigation on the thickness dependence of the ferroelectric properties of poly(vinylidene fluoridetrifluoroethylene) copolymer spin cast films on electroded Si substrate. We show that as the film thickness is reduced, there exist two thickness regions. For films at thickness above 100 nm, the thickness dependence of the ferroelectric properties can be attributed to the interface effect. However, for thinner films, there is a large change in the ferroelectric properties such as the polarization level, the coercive field, and polarization switching speed, which is related to the large drop of the crystallinity in the ultrathin film region (below 100 nm). The results from Xray, dielectric measurement, and AFM all indicate that there is a threshold thickness at about 100 nm below which the crystallinity in the film reduces abruptly.


2021 ◽  
Author(s):  
Tim Brandes ◽  
Stefano Scarso ◽  
Christian Koch ◽  
Stephan Staudacher

Abstract A numerical experiment of intentionally reduced complexity is used to demonstrate a method to classify flight missions in terms of the operational severity experienced by the engines. In this proof of concept, the general term of severity is limited to the erosion of the core flow compressor blade and vane leading edges. A Monte Carlo simulation of varying operational conditions generates a required database of 10000 flight missions. Each flight is sampled at a rate of 1 Hz. Eleven measurable or synthesizable physical parameters are deemed to be relevant for the problem. They are reduced to seven universal non-dimensional groups which are averaged for each flight. The application of principal component analysis allows a further reduction to three principal components. They are used to run a support-vector machine model in order to classify the flights. A linear kernel function is chosen for the support-vector machine due to its low computation time compared to other functions. The robustness of the classification approach against measurement precision error is evaluated. In addition, a minimum number of flights required for training and a sensible number of severity classes are documented. Furthermore, the importance to train the algorithms on a sufficiently wide range of operations is presented.


Ocean Science ◽  
2009 ◽  
Vol 5 (4) ◽  
pp. 661-684 ◽  
Author(s):  
C. Moore ◽  
A. Barnard ◽  
P. Fietzek ◽  
M. R. Lewis ◽  
H. M. Sosik ◽  
...  

Abstract. Requirements for understanding the relationships between ocean color and suspended and dissolved materials within the water column, and a rapidly emerging photonics and materials technology base for performing optical based analytical techniques have generated a diverse offering of commercial sensors and research prototypes that perform optical measurements in water. Through inversion, these tools are now being used to determine a diverse set of related biogeochemical and physical parameters. Techniques engaged include measurement of the solar radiance distribution, absorption, scattering, stimulated fluorescence, flow cytometry, and various spectroscopy methods. Selective membranes and other techniques for material isolation further enhance specificity, leading to sensors for measurement of dissolved oxygen, methane, carbon dioxide, common nutrients and a variety of other parameters. Scientists are using these measurements to infer information related to an increasing set of parameters and wide range of applications over relevant scales in space and time.


Sign in / Sign up

Export Citation Format

Share Document