scholarly journals Hierarchical predictive control of Wastewater Treatment Plants

2018 ◽  
Vol 210 ◽  
pp. 02002
Author(s):  
Ioan Nascu

This paper investigates the performance of a new predictive control approach used to improve the energy efficiency and effluent quality of a conventional Wastewater Treatment Plant (WWTP). A two-layer hierarchical control structure is proposed: process control as a lower layer and a higher layer of optimization. The Activated Sludge Process (ASP) optimization using the proposed approach provides an improved aeration system efficiency to reduce energy costs while maintaining the quality parameters of the effluent. The control strategy is evaluated by performing simulations and analyzing the results. The regulatory performances have been tested and the effects of several tuning parameters are investigated.

2021 ◽  
Vol 83 (7) ◽  
pp. 1633-1648
Author(s):  
Nasim Hejabi ◽  
Seyed Mahdi Saghebian ◽  
Mohammad Taghi Aalami ◽  
Vahid Nourani

Abstract Wastewater treatment plants (WWTPs) are highly complicated and dynamic systems and so their appropriate operation, control, and accurate simulation are essential. The simulation of WWTPs according to the process complexity has become an important issue in growing environmental awareness. In recent decades, artificial intelligence approaches have been used as effective tools in order to investigate environmental engineering issues. In this study, the effluent quality of Tabriz WWTP was assessed using two intelligence models, namely support Vector Machine (SVM) and artificial neural network (ANN). In this regard, several models were developed based on influent variables and tested via SVM and ANN methods. Three time scales, daily, weekly, and monthly, were investigated in the modeling process. On the other hand, since applied methods were sensitive to input variables, the Monte Carlo uncertainty analysis method was used to investigate the best-applied model dependability. It was found that both models had an acceptable degree of uncertainty in modeling the effluent quality of Tabriz WWTP. Next, ensemble approaches were applied to improve the prediction performance of Tabriz WWTP. The obtained results comparison showed that the ensemble methods represented better efficiency than single approaches in predicting the performance of Tabriz WWTP.


2010 ◽  
Vol 2 (5) ◽  
pp. 97-102
Author(s):  
Ala Sokolova ◽  
Mindaugas Rimeika

The paper analyzes the impact of the way of mounting a tube diffuser, the design of an aeration tank and the presence of a fixed carrier on the operational parameters of aeration systems used in small wastewater treatment plants. It was found out that the vertically mounted tube diffuser decreased standard oxygen transfer rate (SOTR) of the aeration system by approximately 20% and standard oxygen transfer efficiency (SOTE) by 25% comparing to the horizontally mounted tube diffuser. It was also defined that the design of the aeration tank might have an impact on the operation parameters of the aeration system: when the centre shell used to protect a diffuser was dismantled from a test tank, SOTR and SOTE increased by approximately 20%. It was also established that the presence of the fixed carrier in the aeration tank did not have an impact on the performance of aeration systems. Finally, research was carried out to compare the operational parameters of two diffusers of different types offered on the market and used in small wastewater treatment plants. It was found out that the performance different type diffusers might vary considerably.


2001 ◽  
Vol 43 (3) ◽  
pp. 85-91 ◽  
Author(s):  
B. Wett ◽  
K. Ingerie

The Biocos strategy as a cyclical time controlled activated sludge system shows a great variability in operation and control. One topic such a type of treatment plant has to deal with is the optimum relation between aerobic and anoxic conditions. The aeration control has to adapt the length of the nitrification phases to the current constraints in order to save operational costs and maximise nitrogen elimination. Since wastewater treatment plants up to a certain size are usually not equipped with on-line nitrogen probes, influent flow and temperature can be taken as control parameters for the aeration system. The defined relation between influent flow and ammonia load is based on measurements and the relation between ammonia load and required aeration time is model based.


Processes ◽  
2019 ◽  
Vol 7 (10) ◽  
pp. 682 ◽  
Author(s):  
An Zhang ◽  
Jinfeng Liu

In this paper, we consider the problem of economic model predictive control of wastewater treatment plants based on model reduction. We apply two model approximation methods to a wastewater treatment plant (WWTP) described by a modified Benchmark Simulation Model No.1 to overcome the intensive computation associated with economic model predictive control (MPC). Two computationally efficient models are obtained based on trajectory piecewise linearization (TPWL) and reduced order TPWL. To obtain the reduced order TPWL model, a proper orthogonal decomposition (POD)-based method is utilized. Further, the reduced order model is linearized to obtain a TPWL-POD model. The objective is to design controllers which minimize the overall economic cost. Accordingly, we design economic MPC (EMPC) controllers based on each of the models. The economic control cost can be described as a weighted summation of effluent quality and overall operating cost. We compare the accuracy of the two proposed approximation models with different linearization point numbers. We evaluate the average


2020 ◽  
Vol 15 (2) ◽  
pp. 142-151
Author(s):  
Peter Lukac ◽  
Lubos Jurik

Abstract:Phosphorus is a major substance that is needed especially for agricultural production or for the industry. At the same time it is an important component of wastewater. At present, the waste management priority is recycling and this requirement is also transferred to wastewater treatment plants. Substances in wastewater can be recovered and utilized. In Europe (in Germany and Austria already legally binding), access to phosphorus-containing sewage treatment is changing. This paper dealt with the issue of phosphorus on the sewage treatment plant in Nitra. There are several industrial areas in Nitra where record major producers in phosphorus production in sewage. The new wastewater treatment plant is built as a mechanicalbiological wastewater treatment plant with simultaneous nitrification and denitrification, sludge regeneration, an anaerobic zone for biological phosphorus removal at the beginning of the process and chemical phosphorus precipitation. The sludge management is anaerobic sludge stabilization with heating and mechanical dewatering of stabilized sludge and gas management. The aim of the work was to document the phosphorus balance in all parts of the wastewater treatment plant - from the inflow of raw water to the outflow of purified water and the production of excess sludge. Balancing quantities in the wastewater treatment plant treatment processes provide information where efficient phosphorus recovery could be possible. The mean daily value of P tot is approximately 122.3 kg/day of these two sources. The mean daily value of P tot is approximately 122.3 kg/day of these two sources. There are also two outflows - drainage of cleaned water to the recipient - the river Nitra - 9.9 kg Ptot/day and Ptot content in sewage sludge - about 120.3 kg Ptot/day - total 130.2 kg Ptot/day.


2008 ◽  
Vol 3 (1) ◽  
Author(s):  
Luchien Luning ◽  
Paul Roeleveld ◽  
Victor W.M. Claessen

In recent years new technologies have been developed to improve the biological degradation of sewage sludge by anaerobic digestion. The paper describes the results of a demonstration of ultrasonic disintegration on the Dutch Wastewater Treatment Plant (WWTP) Land van Cuijk. The effect on the degradation of organic matter is presented, together with the effect on the dewatering characteristics. Recommendations are presented for establishing research conditions in which the effect of sludge disintegration can be determined in a more direct way that is less sensitive to changing conditions in the operation of the WWTP. These recommendations have been implemented in the ongoing research in the Netherlands supported by the National Institute for wastewater research (STOWA).


1993 ◽  
Vol 28 (10) ◽  
pp. 1-8 ◽  
Author(s):  
A. Gaber ◽  
M. Antill ◽  
W. Kimball ◽  
R. Abdel Wahab

The implementation of urban village wastewater treatment plants in developing countries has historically been primarily a function of appropriate technology choice and deciding which of the many needy communities should receive the available funding and priority attention. Usually this process is driven by an outside funding agency who views the planning, design, and construction steps as relatively insignificant milestones in the overall effort required to quickly better a community's sanitary drainage problems. With the exception of very small scale type sanitation projects which have relatively simple replication steps, the development emphasis tends to be on the final treatment plant product with little or no attention specifically focused on community participation and institutionalizing national and local policies and procedures needed for future locally sponsored facilities replication. In contrast to this, the Government of Egypt (GOE) enacted a fresh approach through a Local Development Program with the United States AID program. An overview is presented of the guiding principals of the program which produced the first 24 working wastewater systems including gravity sewers, sewage pumping stations and wastewater treatment plants which were designed and constructed by local entities in Egypt. The wastewater projects cover five different treatment technologies implemented in both delta and desert regions.


2021 ◽  
Vol 13 (9) ◽  
pp. 1757
Author(s):  
Javier Burgués ◽  
María Deseada Esclapez ◽  
Silvia Doñate ◽  
Laura Pastor ◽  
Santiago Marco

Wastewater treatment plants (WWTPs) are sources of greenhouse gases, hazardous air pollutants and offensive odors. These emissions can have negative repercussions in and around the plant, degrading the quality of life of surrounding neighborhoods, damaging the environment, and reducing employee’s overall job satisfaction. Current monitoring methodologies based on fixed gas detectors and sporadic olfactometric measurements (human panels) do not allow for an accurate spatial representation of such emissions. In this paper we use a small drone equipped with an array of electrochemical and metal oxide (MOX) sensors for mapping odorous gases in a mid-sized WWTP. An innovative sampling system based on two (10 m long) flexible tubes hanging from the drone allowed near-source sampling from a safe distance with negligible influence from the downwash of the drone’s propellers. The proposed platform is very convenient for monitoring hard-to-reach emission sources, such as the plant’s deodorization chimney, which turned out to be responsible for the strongest odor emissions. The geo-localized measurements visualized in the form of a two-dimensional (2D) gas concentration map revealed the main emission hotspots where abatement solutions were needed. A principal component analysis (PCA) of the multivariate sensor signals suggests that the proposed system can also be used to trace which emission source is responsible for a certain measurement.


Author(s):  
Tamara Mainetti ◽  
Marilena Palmisano ◽  
Fabio Rezzonico ◽  
Blaž Stres ◽  
Susanne Kern ◽  
...  

AbstractConjugated estrogens, such as 17β-estradiol-3-sulfate (E2-3S), can be released into aquatic environments through wastewater treatment plants (WWTP). There, they are microbiologically degraded into free estrogens, which can have harmful effects on aquatic wildlife. Here, the degradation of E2-3S in environmental samples taken upstream, downstream and at the effluent of a WWTP was assessed. Sediment and biofilm samples were enriched for E2-3S-degrading microorganisms, yielding a broad diversity of bacterial isolates, including known and novel degraders of estrogens. Since E2-3S-degrading bacteria were also isolated in the sample upstream of the WWTP, the WWTP does not influence the ability of the microbial community to degrade E2-3S.


2012 ◽  
Vol 65 (4) ◽  
pp. 589-595 ◽  
Author(s):  
A. Ouali ◽  
H. Jupsin ◽  
J. L. Vasel ◽  
L. Marouani ◽  
A. Ghrabi

Korba wastewater treatment plant is a conventional activated sludge followed by three maturation ponds (MP1, MP2, MP3) in series acting as a tertiary treatment. The first study of wastewater treatment plants showed that the effluent concentration of Escherichia coli and enterococci at the outlet of the (MP3) varies between 103 and 104CFU/100 ml. After the hydrodynamic study conducted by Rhodamine WT which showed short-circuiting in the MP1, two baffles were introduced in the first maturation pond (MP1) to improve the hydrodynamic and the sanitary performances. The second hydraulic study showed that the dispersion number ‘d’ was reduced from 1.45 to 0.43 by this engineering intervention and the Peclet number was raised from 0.69 to 2.32. The hydraulic retention time was increased by 14 h. Because of well-designed baffles, the removal efficiency of E. coli and enterococci was raised between 0.2 and 0.7 log units for the first maturation pond.


Sign in / Sign up

Export Citation Format

Share Document