Thermomechanical Modeling of a Sleeve Rehabilitation System for Pressure Pipes

2020 ◽  
Vol 142 (6) ◽  
Author(s):  
José David Pérez ◽  
Heriberto Maury ◽  
Jorge Bris ◽  
Marianella Ojeda

Abstract The thermomechanical modeling of a sleeve rehabilitation system for pressure pipes is studied including temperature effect on system behavior. The rehabilitation system consists of a multicylinder axisymmetric layer system, with an intermediate layer of epoxy resins and two outer steel covers that are longitudinally welded forming a sleeve. The analysis is conducted over several stages; initially, the incidence of temperature on the rigidity of three types of resins currently available on the market is experimentally evaluated. Then, nonlinear relationships between rigidity and temperature are established from the evaluation of the resins, which are typical of an inhomogeneous material. The resins exhibit a significant loss of rigidity with temperature, generating a risk of delamination that could drastically reduce the effectiveness of the rehabilitation system in the event of possible temperature rises. An analytical model was developed to calculate contact pressures between the resin layer and the external sleeve, internal pipeline displacements, stresses, and deformations. Finally, contour plots were developed for different temperature, pressure levels, and pipe thickness as a graphics tool to predict pipeline failure due to plastic deformation or rupture.

2021 ◽  
Vol 65 (2) ◽  
pp. 65-69
Author(s):  
S. Mukhtar

Abstract There is a significant loss due to corrosion of buried infrastructure. Many pipes have failed due to mistreatment happening within them all around the world. Different soil aeration leads to macro corrosion cells that cause critical levels within the path corrosion leading to a loss of structural integrity of the buried pipes underground. This review paper seeks to address and presents a predetermined model developed by using software COMSOL Multiphysics to identify and characterize the areas experiencing a high rate of corrosion beneath the surface due to differential aeration. The pipe surfaces experience electrochemical reactions and reactant transport mechanisms in the soil and the pipes. Porosity and degree of saturation make the closed-form equations used to create the mass transport properties and electrical properties that constitute three-phase medium using standard soil parameters. The current model enables the study of soil property variations and conditions from the external environment pipeline corrosion. The model results conclude and agree well with the literature and case studies done at pipeline failure sites. The model used in this review will then enable water utilities to develop forecasting tools that may be useful for assessment.


1988 ◽  
Vol 102 ◽  
pp. 107-110
Author(s):  
A. Burgess ◽  
H.E. Mason ◽  
J.A. Tully

AbstractA new way of critically assessing and compacting data for electron impact excitation of positive ions is proposed. This method allows one (i) to detect possible printing and computational errors in the published tables, (ii) to interpolate and extrapolate the existing data as a function of energy or temperature, and (iii) to simplify considerably the storage and transfer of data without significant loss of information. Theoretical or experimental collision strengths Ω(E) are scaled and then plotted as functions of the colliding electron energy, the entire range of which is conveniently mapped onto the interval (0,1). For a given transition the scaled Ω can be accurately represented - usually to within a fraction of a percent - by a 5 point least squares spline. Further details are given in (2). Similar techniques enable thermally averaged collision strengths upsilon (T) to be obtained at arbitrary temperatures in the interval 0 < T < ∞. Application of the method is possible by means of an interactive program with graphical display (2). To illustrate this practical procedure we use the program to treat Ω for the optically allowed transition 2s → 2p in ArXVI.


Author(s):  
J. G. Adams ◽  
M. M. Campbell ◽  
H. Thomas ◽  
J. J. Ghldonl

Since the introduction of epoxy resins as embedding material for electron microscopy, the list of new formulations and variations of widely accepted mixtures has grown rapidly. Described here is a resin system utilizing Maraglas 655, Dow D.E.R. 732, DDSA, and BDMA, which is a variation of the mixtures of Lockwood and Erlandson. In the development of the mixture, the Maraglas and the Dow resins were tested in 3 different volumetric proportions, 6:4, 7:3, and 8:2. Cutting qualities and characteristics of stability in the electron beam and image contrast were evaluated for these epoxy mixtures with anhydride (DDSA) to epoxy ratios of 0.4, 0.55, and 0.7. Each mixture was polymerized overnight at 60°C with 2% and 3% BDMA.Although the differences among the test resins were slight in terms of cutting ease, general tissue preservation, and stability in the beam, the 7:3 Maraglas to D.E.R. 732 ratio at an anhydride to epoxy ratio of 0.55 polymerized with 3% BDMA proved to be most consistent. The resulting plastic is relatively hard and somewhat brittle which necessitates trimming and facing the block slowly and cautiously to avoid chipping. Sections up to about 2 microns in thickness can be cut and stained with any of several light microscope stains and excellent quality light photomicrographs can be taken of such sections (Fig. 1).


Author(s):  
K. Chien ◽  
R.L. Van de Velde ◽  
R.C. Heusser

Sectioning quality of epoxy resins can be improved by the addition of a 1% silicone 200 fluid (Dow Corning), however this produces a softer block. To compensate, a harder plastic has been used for embedding various tissues encountered in our pathology laboratory. Exact amounts of the plastic mixture can be directly made up for embedding as shown: The chart reveals a Poly/Bed 812 (WPE 145) to anhydride ratio of 1:0.7 and a NMA to DDSA ratio of 7:3. 1% silicone fluid is added to above mixtures.Due to impurities within the DDSA and NMA, the polymerized epoxy blocks vary in darkness and appear to affect sectioning quality. After discussing this problem with Polysciences Inc., they have agreed to purify their anhydrides in an effort to standardize the consistency of the plastic.


Author(s):  
Hilton H. Mollenhauer

Many factors (e.g., resolution of microscope, type of tissue, and preparation of sample) affect electron microscopical images and alter the amount of information that can be retrieved from a specimen. Of interest in this report are those factors associated with the evaluation of epoxy embedded tissues. In this context, informational retrieval is dependant, in part, on the ability to “see” sample detail (e.g., contrast) and, in part, on tue quality of sample preservation. Two aspects of this problem will be discussed: 1) epoxy resins and their effect on image contrast, information retrieval, and sample preservation; and 2) the interaction between some stains commonly used for enhancing contrast and information retrieval.


Author(s):  
K. Cowden ◽  
B. Giammara ◽  
T. Devine ◽  
J. Hanker

Plaster of Paris (calcium sulfate hemihydrate, CaSO4. ½ H2O) has been used as a biomedical implant material since 1892. One of the primary limiting factors of these implants is their mechanical properties. These materials have low compressive and tensile strengths when compared to normal bone. These are important limiting factors where large biomechanical forces exist. Previous work has suggested that sterilization techniques could affect the implant’s strength. A study of plaster of Paris implant mechanical and physical properties to find optimum sterilization techniques therefore, could lead to a significant increase in their application and promise for future use as hard tissue prosthetic materials.USG Medical Grade Calcium Sulfate Hemihydrate Types A, A-1 and B, were sterilized by dry heat and by gamma radiation. Types A and B were additionally sterilized with and without the setting agent potassium sulfate (K2SO4). The plaster mixtures were then moistened with a minimum amount of water and formed into disks (.339 in. diameter x .053 in. deep) in polyethylene molds with a microspatula. After drying, the disks were fractured with a Stokes Hardness Tester. The compressive strengths of the disks were obtained directly from the hardness tester. Values for the maximum tensile strengths σo were then calculated: where (P = applied compression, D = disk diameter, and t = disk thickness). Plaster disks (types A and B) that contained no setting agent showed a significant loss in strength with either dry heat or gamma radiation sterilization. Those that contained potassium sulfate (K2SO4) did not show a significant loss in strength with either sterilization technique. In all comparisons (with and without K2SO4 and with either dry heat or gamma radiation sterilization) the type B plaster had higher compressive and tensile strengths than that of the type A plaster. The type A-1 plaster however, which is specially modified for accelerated setting, was comparable to that of type B with K2SO4 in both compressive and tensile strength (Table 1).


1997 ◽  
Vol 40 (2) ◽  
pp. 400-404 ◽  
Author(s):  
Virginia A. Hinton ◽  
Winston M. C. Arokiasamy

It has been hypothesized that typical speech movements do not involve large muscular forces and that normal speakers use less than 20% of the maximum orofacial muscle contractile forces that are available (e.g., Amerman, 1993; Barlow & Abbs, 1984; Barlow & Netsell, 1986; DePaul & Brooks, 1993). However, no direct evidence for this hypothesis has been provided. This study investigated the percentage of maximum interlabial contact pressures (force per unit area) typically used during speech production. The primary conclusion of this study is that normal speakers typically use less than 20% of the available interlabial contact pressure, whether or not the jaw contributes to bilabial closure. Production of the phone [p] at conversational rate and intensity generated an average of 10.56% of maximum available interlabial pressure (MILP) when jaw movement was not restricted and 14.62% when jaw movement was eliminated.


GeroPsych ◽  
2017 ◽  
Vol 30 (2) ◽  
pp. 49-59 ◽  
Author(s):  
Anna L. Seidler ◽  
Julia K. Wolff

Abstract. Background: Previous studies point to a potential relationship between self-perceptions of aging (SPA) and cognitive performance. However, most of these studies are limited by their experimental design. Previous longitudinal studies looked solely at memory as an outcome variable without examining the directionality of effects. The present study examines the direction of effects between two domains of SPA (personal growth and physical losses) and processing speed (PS). Methods: The sample consists of 8,198 participants of the German Ageing Survey (DEAS), aged between 40 and 93 years. A cross-lagged path model was estimated to examine directions of relationships across 3 years via chi-squared difference tests for each domain of SPA. Results: In the unconstrained models, the effect of SPA domain personal growth in 2008 on PS in 2011 and vice versa were marginally significant. For SPA domain physical losses, the effect of SPA on PS was significant, whereas the other direction of the effect did not reach significance. However, the cross-lagged paths of both domains of SPA on PS and vice versa could be set equal without a significant loss of model fit. The resulting associations indicate a significant bidirectional relationship between both domains of SPA and PS. Discussion and conclusion: This study provides initial evidence that SPA can influence trajectories of cognitive decline and vice versa. The results emphasize the detrimental and beneficial effects that stereotypes can have on individuals and add further evidence to the theory of stereotype embodiment.


Sign in / Sign up

Export Citation Format

Share Document