Study of Heat Mass and Mass Transfers in a Spray for Containment Application: Analysis of the Influence of the Spray Mass Flow Rate

Author(s):  
Pascal Lemaitre ◽  
Emmanuel Porcheron

During the course of a hypothetical accident in a nuclear power plant, spray might be activated in order to reduce static pressure in the containment. To have a better understanding of the heat and mass transfers between a spray and the surrounding confined gas, the IRSN has developed the TOSQAN experiment. This article is devoted to analyse the influence of the injected spray mass flow rate on the thermal-hydraulic of spray tests. In order to perform this analysis, two other tests are performed with exactly the same boundary and initial conditions, except the spray mass flow rate that ranges from 10 to 50 g.s−1. First, the scenario of these three tests and the associated results used for this analysis are presented. Then, we focus our analysis on the inter-comparison of the thermal-hydraulic behaviour induced by spray mass flow rates variations. This inter-comparison is divided into two parts: a global and a local one.

2021 ◽  
Author(s):  
Raghuvaran D. ◽  
Satvik Shenoy ◽  
Srinivas G

Abstract Axial flow fans (AFF) are extensively used in various industrial sectors, usually with flows of low resistance and high mass flow rates. The blades, the hub and the shroud are the three major parts of an AFF. Various kinds of optimisation can be implemented to improve the performance of an AFF. The most common type is found to be geometric optimisation including variation in number of blades, modification in hub and shroud radius, change in angle of attack and blade twist, etc. After validation of simulation model and carrying out a grid independence test, parametric analysis was done on an 11-bladed AFF with a shroud of uniform radius using ANSYS Fluent. The rotational speed of the fan and the velocity at fan inlet were the primary variables of the study. The variation in outlet mass flow rate and total pressure was studied for both compressible and incompressible ambient flows. Relation of mass flow rate and total pressure with inlet velocity is observed to be linear and exponential respectively. On the other hand, mass flow rate and total pressure have nearly linear relationship with rotational speed. A comparison of several different axial flow tracks with the baseline case fills one of the research gaps.


Author(s):  
M. K. Mittal ◽  
R. Kumar ◽  
A. Gupta

The objective of this study is to investigate the effect of coiling on the flow characteristics of R-407C in an adiabatic spiral capillary tube. The characteristic coiling parameter for a spiral capillary tube is the coil pitch; hence, the effect of the coil pitch on the mass flow rate of R-407C was studied on several capillary tube test sections. It was observed that the coiling of the capillary tube significantly reduced the mass flow rate of R-407C in the adiabatic spiral capillary tube. In order to quantify the effect of coiling, the experiments were also conducted for straight a capillary tube, and it was observed that the coiling of the capillary tube reduced the mass flow rate in the spiral tube in the range of 9–18% as compared with that in the straight capillary tube. A generalized nondimensional correlation for the prediction of the mass flow rates of various refrigerants was developed for the straight capillary tube on the basis of the experimental data of R-407C of the present study, and the data of R-134a, R-22, and R-410A measured by other researchers. Additionally, a refrigerant-specific correlation for the spiral capillary was also proposed on the basis of the experimental data of R-407C of the present study.


2018 ◽  
Vol 141 (1) ◽  
Author(s):  
Clifford K. Ho ◽  
Joshua M. Christian ◽  
Julius E. Yellowhair ◽  
Kenneth Armijo ◽  
William J. Kolb ◽  
...  

This paper evaluates the on-sun performance of a 1 MW falling particle receiver. Two particle receiver designs were investigated: obstructed flow particle receiver versus free-falling particle receiver. The intent of the tests was to investigate the impact of particle mass flow rate, irradiance, and particle temperature on the particle temperature rise and thermal efficiency of the receiver for each design. Results indicate that the obstructed flow design increased the residence time of the particles in the concentrated flux, thereby increasing the particle temperature and thermal efficiency for a given mass flow rate. The obstructions, a staggered array of chevron-shaped mesh structures, also provided more stability to the falling particles, which were prone to instabilities caused by convective currents in the free-fall design. Challenges encountered during the tests included nonuniform mass flow rates, wind impacts, and oxidation/deterioration of the mesh structures. Alternative materials, designs, and methods are presented to overcome these challenges.


Author(s):  
Khaled Yousef ◽  
Ahmed Hegazy ◽  
Abraham Engeda

Abstract This paper presents a Computational Fluid Dynamic (CFD) simulation for dry air/water-liquid and two-phase flow mixing in a vertical inverted U-tube using the mixture multiphase and turbulence models. This study is to investigate the flow behaviors and underlying some physical mechanisms encountered in dry air/water-liquid flow in the inverted U-tube. Water flows through the inverted U-tube while the dry air is entrained using the side-tube installed after the water flow downward. The inverted U-tube is tested at water mass flow rates of 2,4,6 and 8 kg/s, air mass flow rates, 0.000614–0.02292 kg/s, with dry air volume fractions 0.2–0.9. The obtained results are compared with the experimental data for model validation and the present CFD model is able to give an acceptable agreement. Also, the results show that, at water mass flow rate of 2 kg/s, there are vortices and turbulent intensity disturbances are noticed at the inverted U-tube higher part, which refers to an air entrainment occurrence from the side-tube. Theses disturbances starts to be stabilized at air mass flow rate around 0.00736 kg/s and air volume fraction, αa = 0.75. This means, if the air mass flow rate increases above this limit, the air entrainment may be blocked. On the other side, at water mass flow rate of 4 kg/s, there are little noticed disturbances until air mass flow rate of 0.00368 kg/s and αa = 0.43 and thereafter stabilized. After this point for water mass flow rate of 4 kg/s, increasing air mass flow rate may block the water flow and the whole inverted U-tube system possible stop flowing. Therefore, this study is able to estimate the required operational conditions and mass ratios for stable air entrainment process. Beyond these operational conditions, air entrainment may be blocked and the whole system discontinues its normal induced gravitational flow. In addition, this study proves that the inverted U-tube is able to generate a vacuum pressure up to 53.382 kPa based on the present geometrical configuration. This generated low-pressure by the inverted U-tube can be used for engineering applications which are working under vacuum and need continuous evacuating form the dry air and non-condensable gases. Furthermore, these findings motivate the utilizing of inverted U-tube for the air evacuation purposes for less power consuming in power plants.


2016 ◽  
Vol 836 ◽  
pp. 102-108
Author(s):  
Mirmanto ◽  
Emmy Dyah Sulistyowati ◽  
I Ketut Okariawan

In the rainy season, in tropical countries, to dry stuffs is difficult. Using electrical power or fossil energy is an expensive way. Therefore, it is wise to utilize heat waste. A device that can be used for this purpose is called radiator. The effect of mass flow rate on pressure drop and heat transfer for a dryer room radiator have been experimentally investigated. The room model size was 1000 mm x 1000 mm x 1000 mm made of plywood and the overall radiator dimension was 360 mm x 220 mm x 50 mm made of copper pipes with aluminium fins. Three mass flow rates were investigated namely 12.5 g/s, 14 g/s and 16.5 g/s. The water temperature at the entrance was increased gradually and then kept at 80°C. The maximum temperature reached in the dryer room was 50°C which was at the point just above the radiator. The effect of the mass flow rate on the room temperature was insignificant, while the effect on the pressure drop was significant. Moreover, the pressure drop decreased as the inlet temperature increased. In general, the radiator is recommended to be used as the heat source in a dryer room.


Author(s):  
Racheet Matai ◽  
Savas Yavuzkurt

The performance of an industrial fan was simulated using CFD and results were compared with the experimental data. The fan is used to cool a row of resistor networks which dissipate excess energy generated by regenerative power in an inverter application. It has a diameter of 24 inches (0.6096m) and rotates at different speeds ranging from 2500 to 3900 RPM depending on the requirements. CFD simulation results were also verified by simulating performance of the same fan at different speeds and comparing the results with what was expected from fan affinity laws. The CFD results matched almost exactly (with ∼0.2% difference for pressure at a given flow rate) with the performance being predicted by the affinity laws. The effect of variation of different parameters such as the blade length, number of blades, and blade chord length was studied. Increasing the blade length at the same RPM increased the mass flow rate (by ∼17%) for the same pressure. Increasing the chord length while keeping the same number of blades, at a given RPM, made the performance curve (pressure versus flow rate, i.e. PV curve) steeper and blades stalled at a higher mass flow rate (8.77 kg/sec compared to the previous 8.44 kg/sec). For the same total blade surface area, less number of blades with longer chords stalled at lower mass flow rates (9.22 kg/sec for a 33% shorter chord and 36 blades compared to 8.3 kg/sec for the original rotor which had 24 blades).


2007 ◽  
Vol 129 (4) ◽  
pp. 705-711 ◽  
Author(s):  
G. Belforte ◽  
T. Raparelli ◽  
V. Viktorov ◽  
A. Trivella

In porous resistances, Darcy’s law provides a good approximation of mass flow rate when the differences between upstream and downstream pressures are sufficiently small. In this range, the mass flow rates are proportional to the porous resistance’s permeability. For gas bearings, the pressure difference is normally higher, and it is known experimentally that the mass flow rates are lower than would result from Darcy’s law. Forchheimer’s law adds an inertial term to Darcy’s law and, when an appropriate coefficient is selected for this term, provides a good approximation of flow rates for the same applications even with the highest pressure differences. This paper presents an experimental and theoretical investigation of porous resistances used in gas bearing and thrust pad supply systems. The porous resistances considered in the investigation were made by sintering bronze powders with different grain sizes to produce cylindrical inserts that can be installed in bearing supply devices. The paper describes the test setup and experimental results obtained for: (i) mass flow rate through single porous resistances at different upstream and downstream pressures and (ii) mass flow rate and pressure distribution on a pneumatic pad featuring the same porous resistances. The theoretical permeability of the chosen porous resistances was calculated, and the results from setup (i) were then used to obtain experimental permeability and to determine the inertial coefficients. The results, which are expressed as a function of the Reynolds number, confirmed the validity of using Forchheimer’s law. The mass flow rates from setup (ii) were compared to those from setup (i) at the same pressure differentials across the resistance.


Author(s):  
Vahid Madadi ◽  
Touraj Tavakoli ◽  
Amir Rahimi

AbstractThe energy and exergy performance of a parabolic dish collector is investigated experimentally and theoretically. The effect of receiver type, inlet temperature and mass flow rate of heat transfer fluid (HTF), receiver temperature, receiver aspect ratio and solar radiation are investigated. To evaluate the effect of the receiver aperture area on the system performance, three aperture diameters are considered. It is deduced that the fully opened receivers have the greatest exergy and thermal efficiency. The cylindrical receiver has greater energy and exergy efficiency than the conical one due to less exergy destruction. It is found that the highest exergy destruction is due to heat transfer between the sun and the receivers and counts for 35 % to 60 % of the total wasted exergy. For three selected receiver aperture diameters, the exergy efficiency is minimum for a specified HTF mass flow rate. High solar radiation allows the system to work at higher HTF inlet temperatures. To use this system in applications that need high temperatures, in cylindrical and conical receivers, the HTF mass flow rates lower than 0.05 and 0.09 kg/s are suggested, respectively. For applications that need higher amounts of energy content, higher HTF mass flow rates than the above mentioned values are recommended.


Author(s):  
Zhiwei Zhou ◽  
Yaoli Zhang ◽  
Yanning Yang

Containment is the ultimate barrier which protects the radioactive substance from spreading to the atmosphere. Sensitivity analysis on AP1000 containment during postulated design basis accidents (DBAs) was studied by a dedicated analysis code PCCSAP-3D. The code was a three-dimensional thermal-hydraulic program developed to analyze the transient response of the containment during DBAs; and it was validated at a certain extent. Peak pressure and temperature were the most important phenomena during DBAs. The parameters being studied for sensitivity analysis were break source mass flow rate, containment free space, surface area and volume of heat structures, heat capacity of the containment shell, film coverage, cooling water tank mass flow rate and initial conditions. The results showed that break mass flow rate as well as containment free space had the most significant impact on the peak pressure and temperature during DBAs.