First and second thermodynamic law analyses applied to a solar dish collector

Author(s):  
Vahid Madadi ◽  
Touraj Tavakoli ◽  
Amir Rahimi

AbstractThe energy and exergy performance of a parabolic dish collector is investigated experimentally and theoretically. The effect of receiver type, inlet temperature and mass flow rate of heat transfer fluid (HTF), receiver temperature, receiver aspect ratio and solar radiation are investigated. To evaluate the effect of the receiver aperture area on the system performance, three aperture diameters are considered. It is deduced that the fully opened receivers have the greatest exergy and thermal efficiency. The cylindrical receiver has greater energy and exergy efficiency than the conical one due to less exergy destruction. It is found that the highest exergy destruction is due to heat transfer between the sun and the receivers and counts for 35 % to 60 % of the total wasted exergy. For three selected receiver aperture diameters, the exergy efficiency is minimum for a specified HTF mass flow rate. High solar radiation allows the system to work at higher HTF inlet temperatures. To use this system in applications that need high temperatures, in cylindrical and conical receivers, the HTF mass flow rates lower than 0.05 and 0.09 kg/s are suggested, respectively. For applications that need higher amounts of energy content, higher HTF mass flow rates than the above mentioned values are recommended.

Author(s):  
Junfei Zhou ◽  
Xinjun Wang ◽  
Jun Li ◽  
Feng Zhang ◽  
Daren Zheng

This paper presents a numerical comparison of the flow and conjugate heat transfer characteristics about the internal cooling of a nozzle guide vane with three kinds of coolants, including air, steam and mist/steam. Five radial cooling channels are established inside the vanes. The Reynolds-averaged Navier–Stokes equations, coupled with a fully-developed Shear Stress Transport (with γ-θ transition) turbulent model, are adopted and solved. Different coolant mass flow rates are examined. Different initial mist diameters and mist concentrations are numerically calculated. The mist tracks in five internal channels and the cooling effectiveness at the mid-span are obtained and compared among different initial mist diameters and mist concentrations. The turbulence kinetic energy and heat transfer coefficient inside the internal channel are used to further investigate the effects of the droplet size. The mean cooling effectiveness of the vane outer surface is obtained at different coolant mass flow rates. Results show that the mist/steam cooling has a best cooling performance compared with that of the air and steam. The influence of the mist concentration is much smaller than the initial mist diameter on the mists evaporation. The mists can evaporate entirely at a relative small initial diameter and the evaporation distance increases about two times with the mist mass flow rate increases from 1% ∼ 5% coolant mass flow rate. With a same mist concentration, the faster the mists evaporate, the higher the cooling effectiveness is obtained. Under a certain coolant mass flow rate, the amplification of the mean cooling effectiveness decreases with the increase of the mist concentration. With the increase of the coolant mass flow rate, the differences of the mean cooling effectiveness among different mist concentrations become larger.


Author(s):  
M. K. Mittal ◽  
R. Kumar ◽  
A. Gupta

The objective of this study is to investigate the effect of coiling on the flow characteristics of R-407C in an adiabatic spiral capillary tube. The characteristic coiling parameter for a spiral capillary tube is the coil pitch; hence, the effect of the coil pitch on the mass flow rate of R-407C was studied on several capillary tube test sections. It was observed that the coiling of the capillary tube significantly reduced the mass flow rate of R-407C in the adiabatic spiral capillary tube. In order to quantify the effect of coiling, the experiments were also conducted for straight a capillary tube, and it was observed that the coiling of the capillary tube reduced the mass flow rate in the spiral tube in the range of 9–18% as compared with that in the straight capillary tube. A generalized nondimensional correlation for the prediction of the mass flow rates of various refrigerants was developed for the straight capillary tube on the basis of the experimental data of R-407C of the present study, and the data of R-134a, R-22, and R-410A measured by other researchers. Additionally, a refrigerant-specific correlation for the spiral capillary was also proposed on the basis of the experimental data of R-407C of the present study.


2016 ◽  
Vol 836 ◽  
pp. 102-108
Author(s):  
Mirmanto ◽  
Emmy Dyah Sulistyowati ◽  
I Ketut Okariawan

In the rainy season, in tropical countries, to dry stuffs is difficult. Using electrical power or fossil energy is an expensive way. Therefore, it is wise to utilize heat waste. A device that can be used for this purpose is called radiator. The effect of mass flow rate on pressure drop and heat transfer for a dryer room radiator have been experimentally investigated. The room model size was 1000 mm x 1000 mm x 1000 mm made of plywood and the overall radiator dimension was 360 mm x 220 mm x 50 mm made of copper pipes with aluminium fins. Three mass flow rates were investigated namely 12.5 g/s, 14 g/s and 16.5 g/s. The water temperature at the entrance was increased gradually and then kept at 80°C. The maximum temperature reached in the dryer room was 50°C which was at the point just above the radiator. The effect of the mass flow rate on the room temperature was insignificant, while the effect on the pressure drop was significant. Moreover, the pressure drop decreased as the inlet temperature increased. In general, the radiator is recommended to be used as the heat source in a dryer room.


Author(s):  
Louis A. Tse ◽  
Reza Baghaei Lakeh ◽  
Richard E. Wirz ◽  
Adrienne S. Lavine

In this work, energy and exergy analyses are applied to a thermal energy storage system employing a storage medium in the two-phase or supercritical regime. First, a numerical model is developed to investigate the transient thermodynamic and heat transfer characteristics of the storage system by coupling conservation of energy with an equation of state to model the spatial and temporal variations in fluid properties during the entire working cycle of the TES tank. Second, parametric studies are conducted to determine the impact of key variables (such as heat transfer fluid mass flow rate and maximum storage temperature) on both energy and exergy efficiencies. The optimum heat transfer fluid mass flow rate during charging must balance exergy destroyed due to heat transfer and exergy destroyed due to pressure losses, which have competing effects. Similarly, the optimum maximum storage fluid temperature is evaluated to optimize exergetic efficiency. By incorporating exergy-based optimization alongside traditional energy analyses, the results of this study evaluate the optimal values for key parameters in the design and operation of TES systems, as well as highlight opportunities to minimize thermodynamic losses.


2007 ◽  
Vol 129 (4) ◽  
pp. 705-711 ◽  
Author(s):  
G. Belforte ◽  
T. Raparelli ◽  
V. Viktorov ◽  
A. Trivella

In porous resistances, Darcy’s law provides a good approximation of mass flow rate when the differences between upstream and downstream pressures are sufficiently small. In this range, the mass flow rates are proportional to the porous resistance’s permeability. For gas bearings, the pressure difference is normally higher, and it is known experimentally that the mass flow rates are lower than would result from Darcy’s law. Forchheimer’s law adds an inertial term to Darcy’s law and, when an appropriate coefficient is selected for this term, provides a good approximation of flow rates for the same applications even with the highest pressure differences. This paper presents an experimental and theoretical investigation of porous resistances used in gas bearing and thrust pad supply systems. The porous resistances considered in the investigation were made by sintering bronze powders with different grain sizes to produce cylindrical inserts that can be installed in bearing supply devices. The paper describes the test setup and experimental results obtained for: (i) mass flow rate through single porous resistances at different upstream and downstream pressures and (ii) mass flow rate and pressure distribution on a pneumatic pad featuring the same porous resistances. The theoretical permeability of the chosen porous resistances was calculated, and the results from setup (i) were then used to obtain experimental permeability and to determine the inertial coefficients. The results, which are expressed as a function of the Reynolds number, confirmed the validity of using Forchheimer’s law. The mass flow rates from setup (ii) were compared to those from setup (i) at the same pressure differentials across the resistance.


2018 ◽  
Vol 12 (4) ◽  
pp. 4098-4116
Author(s):  
M. Abid ◽  
B. A. A. Yousef ◽  
M. E. Assad ◽  
A. Hepbasli ◽  
K. Saeed

Building sector consumes a greater portion of energy for heating and cooling applications. The utilization of fossil fuels for space and water heating in buildings cause a negative effect on the environment by producing larger CO2. In this study solar thermal water heating system for building application have been analyzed from the first and second law perspectives of thermodynamics considering various scenarios and water consumption pattern. The solar flat collector is very commonly used to extract energy from sunlight. Therefor energy and exergy efficiency curves for the solar flat collector were presented. The energetic and exergetic values for the system were calculated based on the experimental values for the overall system, the heat exchanger and the pumps using the approach of exergetic product/fuel basis. The greatest and lowest relative irreversibility’s occurred at the solar collector and the heat exchanger with values of 85.73% and 2.45%, respectively, and the system overall exergy efficiency was determined to be 20.28%. The energy and exergy efficiencies of the solar collector were analyzed at three different cases depending on the mass flow rates in the solar collector and the secondary circuit of the system. Three different mass flow rates were applied to the inlet of the secondary circuit to observe the efficiency effect on the solar collector circuit. This study can assist in selecting a proper solar collector and storage size for buildings of various capacity and possible improvement in the design of the system components.


Author(s):  
Muhammad Ali Kamran ◽  
Shahryar Manzoor

A comprehensive experimental study on the effects of different operating parameters on the efficiency of tesla turbine is reported. A bladeless turbine with nine discs and up to four turbine inlets was used, with water as the working fluid. The parameters investigated are the nozzle angle, number of turbine inlets and mass flow rates. Contrary to earlier studies, an effort was made to determine the performance under varying loading conditions, and hence identify the complete performance characteristics. The study revealed that efficiency of the turbine increases at lower nozzle angles and higher number of turbine inlets. It was observed that the nozzle angle becomes a significant parameter when the number of turbine inlets is increased. Efficiencies up to 78% were achieved when the working fluid entered the turbine through two nozzles at an angle of 7°. It was also noted that the turbine is most efficient at the designed mass flow rate, and the efficiency reduces appreciably if lower mass flow rates are fed to the turbine. The results obtained are an important contribution to the available knowledge and can be used as design references for further studies.


2021 ◽  
Author(s):  
Mohamed Thalib Mohamed Rafeek ◽  
Vimala Muthu ◽  
Muthu Manokar Athikesavan ◽  
Ravishankar Sathyamurthy ◽  
Abd Elnaby Kabeel

Abstract The objective of the current study is to investigate the performance of the Inclined Solar Panel Basin Still (ISPBS) incorporated with a Spiral Tube Collector (STC) for various mass flow rates of water (mf). The maximum potable water yield of 8.1, 6.9 and 6.1 kg is obtained for different mass flow rates of 1.8, 3.2 and 4.7 kg/hr in each instance. Also, for mf values of 1.8, 3.2 and 4.7 kg per hour, the daily average energy and exergy efficiency of the ISPBS is recorded to be 47.9, 39.3 and 31.02 % and 9.8, 7.9 and 5.6 % in each instance. The average electrical, energy and exergy efficiency of the PV panel is noted to be 6.5, 7.1 and 7.5 %, 15.67, 17.1 and 18.04 % and 20.03, 22.21 and 23.36 % for mf values of 1.8, 3.2 and 4.7 kg/hr in each instance. The rise in mf causes a drop in the fresh water production yield, thermal, exergy and overall thermal effectiveness and an enhancement in the power production of the panel, electrical, thermal, exergy and overall exergy efficiency of the system.


2017 ◽  
Vol 2017 ◽  
pp. 1-14 ◽  
Author(s):  
Seyyed Mahdi Taheri Mousavi ◽  
Fuat Egelioglu

The thermal performances of three slit-glazed solar air heaters (SGSAHs) were investigated experimentally. Three SGSAHs with different bed heights (7 cm, 5 cm, and 3 cm) were fabricated with multiple glass panes used for glazing. The length, width, and thickness of each pane were 154 cm, 6 cm, and 0.4 cm, respectively. Ambient air was continuously withdrawn through the gaps between the glass panes by fans. The experiments were conducted for four different gap distances between the glass panes (0.5 mm, 1 mm, 2 mm, and 3 mm) and the air mass flow rate was varied between 0.014 kg/s and 0.057 kg/s. The effects of air mass flux on the outlet temperature and thermal efficiency were studied. For the SGSAH with bed height of 7 cm and glass pane gap distance of 0.5 mm, the highest efficiency was obtained as 82% at a mass flow rate of 0.057 kg/s and the air temperature difference between the inlet and the outlet (∆T) was maximum (27°C) when the mass flow rate was least. The results demonstrate that for lower mass flow rates and larger gaps, the performance of SGSAH with a bed height of 3 cm was better compared to that of others. However, for higher mass flow rates, the SGSAH with 7 cm bed height performed better.


Author(s):  
Federico M Berruti ◽  
Lorenzo Ferrante ◽  
Franco Berruti ◽  
Cedric Briens

Among many other potential applications, intermittent solid slug feeders can be used to effectively inject biomass materials into fluidized bed reactors for pyrolysis. In particular, these feeders can be used to convey biomass materials that are highly cohesive to prevent plugging or undesirable reaction in the feeding tube. Although feeders of this design have been shown to work very effectively, they have not been studied in detail or optimized for the pyrolysis process. In addition, the operating conditions required to obtain predictable and consistent mass flow rates and slugs of desirable characteristics need to be established.The purpose of this work was to design, build and demonstrate the operation of a horizontal intermittent solid slug feeder and to test it with sawdust as the feed material. Sawdust is an extremely cohesive and difficult biomass to inject, but one that holds great potential as an important renewable feedstock for pyrolysis.The intermittent feeder designed for this work consisted of a pressurized vertical solids storage silo leading to a pneumatic pinch valve. The pinch valve, controlled by solenoid valves connected to a relay timer, released the feed into a horizontal feeding tube at a ninety degree angle. Within the silo, a rotating mixer prevented the bridging of solids. Intermittent pulses of gas from a control volume were fed into the horizontal feeding tube, as well as, in some cases, a continuous gas flow. The timing of the pulses was controlled by solenoid valves with a relay timer. While the pinch valve is opened, solids fall into the horizontal feeding tube forming a plug, which is then propelled by the pulsating gas into the reactor. The solid mass flow rate was experimentally measured by collecting the solids and continuously measuring the mass using a digital balance.Several variables were tested in order to optimize the performance of the feeder and the consistency of the feeding rate. They included the silo pressure, mixing rate, gas pulse pressure and volume, continuous gas mass flow rate, and the open pinch-valve time interval. The goals of this optimization were (a) to maximize the solid-to-gas ratio of mass flow rates, since the gas mass flux must be minimized to avoid wasting energy, and (b) to define operating conditions required to inject consistent biomass mass flow rates suitable for a laboratory scale pyrolysis reactor, and (c) to propose initial design criteria and a calibration procedure for intermittent solid slug feeders.The results demonstrated that the intermittent solid slug feeder system successfully achieved the desired objectives and showed how to efficiently select its optimum operating conditions.


Sign in / Sign up

Export Citation Format

Share Document