Laser-driven ion acceleration at the TERESA target area of ELI Beamlines

Author(s):  
Andriy Velyhan
Keyword(s):  
2011 ◽  
Vol 29 (4) ◽  
pp. 437-446 ◽  
Author(s):  
M. Schnürer ◽  
A.A. Andreev ◽  
S. Steinke ◽  
T. Sokollik ◽  
T. Paasch-Colberg ◽  
...  

AbstractAdvancement of ion acceleration by intense laser pulses is studied with ultra-thin nanometer-thick diamond like carbon and micrometer-thick Titanium target foils. Both investigations aim at optimizing the electron density distribution which is the key for efficient laser driven ion acceleration. While recently found maximum ion energies achieved with ultra-thin foils mark record values micrometer thick foils are flexible in terms of atomic constituents. Electron recirculation is one prerequisite for the validity of a very simple model that can approximate the dependence of ion energies of nanometer-thick targets when all electrons of the irradiated target area interact coherently with the laser pulse and Coherent Acceleration of Ions by Laser pulses (CAIL) becomes dominant. Complementary experiments, an analytical model and particle in cell computer simulations show, that with regard to ultra-short laser pulses (duration ~45 fs at intensities up to 5 × 1019 W/cm2) and a micrometer-thick target foil with higher atomic number a close to linear increase of ion energies manifests in a certain range of laser intensities.


2018 ◽  
Vol 24 (1) ◽  
Author(s):  
SHVETA PATEL ◽  
RAJENDRA SINGH

Extensive survey of mantids in the northeastern Uttar Pradesh was conducted. Two mantid species were recorded for the first time from the target area, viz.: Pyrgomantis pallida, 1917 and Bactromantis mexicana.


2014 ◽  
Vol 184 (12) ◽  
pp. 1265-1298 ◽  
Author(s):  
Sergei V. Bulanov ◽  
Jan J. Wilkens ◽  
Timur Zh. Esirkepov ◽  
Georg Korn ◽  
G. Kraft ◽  
...  

2016 ◽  
Vol 5 (2) ◽  
pp. 83-91
Author(s):  
Miftafu Darussalam ◽  
Dwi Kartika Rukmi

Background: Uric acid is a final product or a waste that is resulted from the metabolism of purines. A high level of uric acid (hyperuricemia) will cause several health problems, such as vascular inflammation, smooth muscle proliferation, and vascular lesion in kidneys. The syzygium polyanthum leaves contain bioactive substances that may affect the level of uric acid in blood. Objective: This study aimed to determine the influence of boiled water of syzygium polyanthum leaves to the changes of uric acid levels in the target area of Puskesmas Pandak 1 Bantul. Methods: This study employed pre- and post-test without control group design. The population consisted of all patients with hyperuricemia in the target area of Puskesmas Pandak 1 Bantul. Sample was selected with a concecutive sampling, gaining a total number of 24 respondents. Data were analyzed with the Wilcoxon test. The dose of boiled water of syzygium polyanthum leaves intake was 0.36g/ KgBW, once a day for 14 days. Result: This research showed that the boiled water of syzygium polyanthum leaves decreased hyperuricemia (uric acid levels), along with the significancy value of 0.009 (p <0.05). At the pre-test time, the average level of uric acid reached 7.279 mg/dl, and after the treatment, it decreased to 6.76 mg/dl. Conclusion: This study has established evidence that the boiled water of syzygium polyanthum leaves is able to decrease hyperuricemia (uric acid level in blood). Keywords: syzygium polyanthum, boiled water of syzygium polyanthum leaves, hyperuricemia


2018 ◽  
Vol 20 (4) ◽  
pp. 043047 ◽  
Author(s):  
R Mishra ◽  
F Fiuza ◽  
S Glenzer
Keyword(s):  

2021 ◽  
Vol 22 (8) ◽  
pp. 4087
Author(s):  
Maria Quitério ◽  
Sandra Simões ◽  
Andreia Ascenso ◽  
Manuela Carvalheiro ◽  
Ana Paula Leandro ◽  
...  

Insulin is a peptide hormone with many physiological functions, besides its use in diabetes treatment. An important role of insulin is related to the wound healing process—however, insulin itself is too sensitive to the external environment requiring the protective of a nanocarrier. Polymer-based nanoparticles can protect, deliver, and retain the protein in the target area. This study aims to produce and characterize a topical treatment for wound healing consisting of insulin-loaded poly-DL-lactide/glycolide (PLGA) nanoparticles. Insulin-loaded nanoparticles present a mean size of approximately 500 nm and neutral surface charge. Spherical shaped nanoparticles are observed by scanning electron microscopy and confirmed by atomic force microscopy. SDS-PAGE and circular dichroism analysis demonstrated that insulin preserved its integrity and secondary structure after the encapsulation process. In vitro release studies suggested a controlled release profile. Safety of the formulation was confirmed using cell lines, and cell viability was concentration and time-dependent. Preliminary safety in vivo assays also revealed promising results.


Author(s):  
Simona Malaspina ◽  
Vesa Oikonen ◽  
Anna Kuisma ◽  
Otto Ettala ◽  
Kalle Mattila ◽  
...  

Abstract Purpose This phase 1 open-label study evaluated the uptake kinetics of a novel theranostic PET radiopharmaceutical, 18F-rhPSMA-7.3, to optimise its use for imaging of prostate cancer. Methods Nine men, three with high-risk localised prostate cancer, three with treatment-naïve hormone-sensitive metastatic disease and three with castration-resistant metastatic disease, underwent dynamic 45-min PET scanning of a target area immediately post-injection of 300 MBq 18F-rhPSMA-7.3, followed by two whole-body PET/CT scans acquired from 60 and 90 min post-injection. Volumes of interest (VoIs) corresponding to prostate cancer lesions and reference tissues were recorded. Standardised uptake values (SUV) and lesion-to-reference ratios were calculated for 3 time frames: 35–45, 60–88 and 90–118 min. Net influx rates (Ki) were calculated using Patlak plots. Results Altogether, 44 lesions from the target area were identified. Optimal visual lesion detection started 60 min post-injection. The 18F-rhPSMA-7.3 signal from prostate cancer lesions increased over time, while reference tissue signals remained stable or decreased. The mean (SD) SUV (g/mL) at the 3 time frames were 8.4 (5.6), 10.1 (7) and 10.6 (7.5), respectively, for prostate lesions, 11.2 (4.3), 13 (4.8) and 14 (5.2) for lymph node metastases, and 4.6 (2.6), 5.7 (3.1) and 6.4 (3.5) for bone metastases. The mean (SD) lesion-to-reference ratio increases from the earliest to the 2 later time frames were 40% (10) and 59% (9), respectively, for the prostate, 65% (27) and 125% (47) for metastatic lymph nodes and 25% (19) and 32% (30) for bone lesions. Patlak plots from lesion VoIs signified almost irreversible uptake kinetics. Ki, SUV and lesion-to-reference ratio estimates showed good agreement. Conclusion 18F-rhPSMA-7.3 uptake in prostate cancer lesions was high. Lesion-to-background ratios increased over time, with optimal visual detection starting from 60 min post-injection. Thus, 18F-rhPSMA-7.3 emerges as a very promising PET radiopharmaceutical for diagnostic imaging of prostate cancer. Trial Registration NCT03995888 (24 June 2019).


2021 ◽  
Vol 7 (1) ◽  
Author(s):  
Chiaki Yamada ◽  
Aiko Maeda ◽  
Katsuyuki Matsushita ◽  
Shoko Nakayama ◽  
Kazuhiro Shirozu ◽  
...  

Abstract Background Patients with spinal cord injury (SCI) frequently complain of intractable pain that is resistant to conservative treatments. Here, we report the successful application of 1-kHz high-frequency spinal cord stimulation (SCS) in a patient with refractory neuropathic pain secondary to SCI. Case presentation A 69-year-old male diagnosed with SCI (C4 American Spinal Injury Association Impairment Scale A) presented with severe at-level bilateral upper extremity neuropathic pain. Temporary improvement in his symptoms with a nerve block implied peripheral component involvement. The patient received SCS, and though the tip of the leads could not reach the cervical vertebrae, a 1-kHz frequency stimulus relieved the intractable pain. Conclusions SCI-related symptoms may include peripheral components; SCS may have a considerable effect on intractable pain. Even when the SCS electrode lead cannot be positioned in the target area, 1-kHz high-frequency SCS may still produce positive effects.


Sign in / Sign up

Export Citation Format

Share Document