scholarly journals Surveillance of Batai Virus in Bovines from Germany

2015 ◽  
Vol 22 (6) ◽  
pp. 672-673 ◽  
Author(s):  
Miriam Hofmann ◽  
Anke Wiethölter ◽  
Irena Blaha ◽  
Hanna Jöst ◽  
Patrick Heinemann ◽  
...  

ABSTRACTTo estimate the veterinary importance of Batai virus (BATV), we investigated the presence of BATV-specific antibodies and BATV RNA in 548 bovines from southwest Germany, and we demonstrated that 3 cattle serum samples contained BATV-neutralizing antibodies, resulting in a seroprevalence of 0.55%. Thus, our results confirm local transmission and indicate cattle as potential hosts of BATV in southwest Germany.

Author(s):  
Shazeda Chowdhury ◽  
Sara Taleb ◽  
Mahmoud Elgamal ◽  
Nesyia Hassan ◽  
Michail Nomikos ◽  
...  

Background: COVID-19 pandemic created an unprecedented demand for reagents and diagnostic tools to confirm COVID-19 cases. Thus, the development of a robust in-house diagnostic test is considered of high importance. Within a few days after exposure, the human body produces specific antibodies that recognize the surface proteins of the invading SARS-CoV-2 virus. Therefore, virus specific immunoglobulins are neutralizing antibodies and their appearance in the blood is a good sign of immunity. The aim of this study was to develop an in-house COVID-19 serology ELISA test to quantify induced antibody responses. This test can help identify convalescent plasma donors with high antibody titers that can be used to treat other patients. Methods: Spike protein antigen is highly expressed in SARS-CoV-2. Recombinant protein corresponding to the spike receptor-binding domain (RBD), which binds to specific antibodies circulating in COVID-19 patients’ blood was used as the antigen in this colorimetric ELISA test. Briefly, a 96-microtiter well plate was coated with RBD protein, where serum dilutions were added. Antibody titers were detected using an anti-human IgG- peroxidase labelled antibody and the substrate o-phenylenediamine dihydrochloride; measured at optical density (OD) of 450 nm. Results: The in-house quantitative serology test was validated using serum samples collected from severe COVID-19 patients (n = 282) admitted to the intensive care unit at Hamad General Hospital. Serum samples from non-COVID-19 (n = 10) were used as a negative control. We detected high antibody titers in ~90% of COVID-19 sera. In contrast, no SARS-CoV-2 specific antibodies were detected in the serum of non-infected subjects (n = 6), pooled human serum collected before 2019, or Middle East Respiratory Syndrome (MERS) infected subjects (n = 3) confirming the specificity and the sensitivity of this in-house serology test. Conclusion: This in-house quantitative serology test is sensitive, specific, and inexpensive. The test can address the rising issue of COVID-19 supply chain globally and foster the capacity-building efforts envisioned by Qatar University.


Diagnostics ◽  
2021 ◽  
Vol 11 (6) ◽  
pp. 994
Author(s):  
Ahmed Majdi K. Tolah ◽  
Sayed S. Sohrab ◽  
Khaled Majdi K. Tolah ◽  
Ahmed M. Hassan ◽  
Sherif A. El-Kafrawy ◽  
...  

The unusual cases of pneumonia outbreak were reported from Wuhan city in late December 2019. Serological testing provides a powerful tool for the identification of prior infection and for epidemiological studies. Pseudotype virus neutralization assays are widely used for many viruses and applications in the fields of serology. The accuracy of pseudotype neutralizing assay allows for its use in low biosafety lab and provides a safe and effective alternative to the use of wild-type viruses. In this study, we evaluated the performance of this assay compared to the standard microneutralization assay as a reference. The lentiviral pseudotype particles were generated harboring the Spike gene of SARS-CoV-2. The generated pseudotype particles assay was used to evaluate the activity of neutralizing antibodies in 300 human serum samples from a COVID-19 sero-epidemiological study. Testing of these samples resulted in 55 positive samples and 245 negative samples by pseudotype viral particles assay while microneutralization assay resulted in 64 positive and 236 negative by MN assay. Compared to the MN, the pseudotyped viral particles assay showed a sensitivity of 85.94% and a specificity of 100%. Based on the data generated from this study, the pseudotype-based neutralization assay showed a reliable performance for the detection of neutralizing antibodies against SARS-CoV-2 and can be used safely and efficiently as a diagnostic tool in a biosafety level 2 laboratory.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Jean-François Bruxelle ◽  
Tess Kirilenko ◽  
Nino Trattnig ◽  
Yiqiu Yang ◽  
Matteo Cattin ◽  
...  

AbstractThe occurrence of oligomannose-specific broadly neutralizing antibodies (bnAbs) has spurred efforts to develop immunogens that can elicit similar antibodies. Here, we report on the antigenicity and immunogenicity of a CRM197-conjugate of a previously reported oligomannose mimetic. Oligomannose-specific bnAbs that are less dependent on interactions with the HIV envelope protein sequence showed strong binding to the glycoconjugates, with affinities approximating those reported for their cognate epitope. The glycoconjugate is also recognized by inferred germline precursors of oligomannose-specific bnAbs, albeit with the expected low avidity, supporting its potential as an immunogen. Immunization of human-antibody transgenic mice revealed that only a TLR4-stimulating adjuvant formulation resulted in antibodies able to bind a panel of recombinant HIV trimers. These antibodies bound at relatively modest levels, possibly explaining their inability to neutralize HIV infectivity. Nevertheless, these findings contribute further to understanding conditions for eliciting HIV-cross-reactive oligomannose-specific antibodies and inform on next steps for improving on the elicited response.


Author(s):  
Vincent Legros ◽  
Solène Denolly ◽  
Manon Vogrig ◽  
Bertrand Boson ◽  
Eglantine Siret ◽  
...  

AbstractUnderstanding the immune responses elicited by SARS-CoV-2 infection is critical in terms of protection against reinfection and, thus, for public health policy and vaccine development for COVID-19. In this study, using either live SARS-CoV-2 particles or retroviruses pseudotyped with the SARS-CoV-2 S viral surface protein (Spike), we studied the neutralizing antibody (nAb) response in serum samples from a cohort of 140 SARS-CoV-2 qPCR-confirmed infections, including patients with mild symptoms and also more severe forms, including those that required intensive care. We show that nAb titers correlated strongly with disease severity and with anti-spike IgG levels. Indeed, patients from intensive care units exhibited high nAb titers; conversely, patients with milder disease symptoms had heterogeneous nAb titers, and asymptomatic or exclusive outpatient-care patients had no or low nAbs. We found that nAb activity in SARS-CoV-2-infected patients displayed a relatively rapid decline after recovery compared to individuals infected with other coronaviruses. Moreover, we found an absence of cross-neutralization between endemic coronaviruses and SARS-CoV-2, indicating that previous infection by human coronaviruses may not generate protective nAbs against SARS-CoV-2. Finally, we found that the D614G mutation in the spike protein, which has recently been identified as the current major variant in Europe, does not allow neutralization escape. Altogether, our results contribute to our understanding of the immune correlates of SARS-CoV-2-induced disease, and rapid evaluation of the role of the humoral response in the pathogenesis of SARS-CoV-2 is warranted.


Viruses ◽  
2021 ◽  
Vol 13 (2) ◽  
pp. 303
Author(s):  
Wei-Ting Hsu ◽  
Chia-Yu Chang ◽  
Chih-Hsuan Tsai ◽  
Sung-Chan Wei ◽  
Huei-Ru Lo ◽  
...  

Porcine epidemic diarrhea virus (PEDV) is a coronavirus that causes serious and highly contagious enteric disease in swine worldwide. In this study, we constructed a recombinant baculovirus (S-Bac) expressing full-length spike protein of the virulent epidemic genotype 2b (G2b) PEDV strain for serological studies of infected pigs. We found that most spike-specific antibodies produced upon PEDV infection in pigs are conformation-specific and they could be detected on S-Bac-infected insect cells by immunofluorescent assay, but they were insensitive to Western blot analysis, the typical method for antiserum analysis. These results indicated that spike conformation is crucial for serum recognition. Since it is difficult to purify trimeric spike membrane protein for conventional enzyme-linked immunosorbent assay (ELISA), we used S-Bac to generate a novel cell-based ELISA for convenient PEDV detection. We analyzed 100 pig serum samples, and our cell-based ELISA exhibited a sensitivity of 100%, a specificity of 97%, and almost perfect agreement [Cohen’s kappa coefficient value (κ) = 0.98] with immunocytochemical staining results. Our cell-based ELISA rapidly presented antigen for proper detection of conformation-specific antibodies, making PEDV detection more convenient, and it will be useful for detecting many viral diseases in the future.


Author(s):  
Eide Dias Camargo ◽  
Paulo Mutuko Nakamura ◽  
Adelaide José Vaz ◽  
Marcos Vinícius da Silva ◽  
Pedro Paulo Chieffi ◽  
...  

The dot-enzyme-linked immunosorbent assay (dot-ELISA) was standardized using somatic (S) and excretory-secretory (ES) antigens of Toxocara-canis for the detection of specific antibodies in 22 serum samples from children aged 1 to 15 years, with clinical signs of toxocariasis. Fourteen serum samples from apparently normal individuals and 28 sera from patients with other pathologies were used as controls. All samples were used before and after absorption with Ascaris suum extract. When the results were evaluated in comparison with ELISA, the two tests were found to have similar sensitivity, but dot-ELISA was found to be more specific in the presence of the two antigens studied. Dot-ELISA proved to be effective for the diagnosis of human toxocariasis, presenting advantages in terms of yield, stability, time and ease of execution and low cost.


2003 ◽  
Vol 10 (3) ◽  
pp. 388-393 ◽  
Author(s):  
Francois-Xavier Mbopi-Kéou ◽  
Laurent Bélec ◽  
Julie Dalessio ◽  
Jérôme Legoff ◽  
Gérard Grésenguet ◽  
...  

ABSTRACT Antibodies to herpes simplex virus type 1 (HSV-1) and HSV-2 of the immunoglobulin G (IgG) and IgA isotypes were detected in the cervicovaginal secretions (CVS) of 77 HSV-1- and HSV-2-seropositive but clinically asymptomatic African women by type-specific enhanced chemiluminescence Western blotting (ECL-WB). Of the 77 subjects, 34 were HIV negative, shedding HSV-2 DNA in their genital secretions; 20 were HIV positive, shedding HSV-2 DNA; and 23 were HIV negative, not shedding HSV-2 DNA. HSV-specific IgG was detected in CVS of nearly 70% of the women studied. HSV-specific IgA was found in CVS of 50% of the women studied. The distribution of CVS HSV-specific antibodies to each HSV type was highly heterogeneous, with a slight predominance of detectable IgG to HSV-1 (59%) over IgG to HSV-2 (41%), whereas the frequency of detectable IgA to HSV-1 (39%) was similar to that of IgA to HSV-2 (36%). The presence of detectable HSV-specific antibodies was inversely associated with HSV-2 DNA genital asymptomatic shedding but was not affected by HIV seropositivity. In addition, 13 of 77 (17%) CVS samples showed neutralizing activity against HSV-2, as assessed by an HSV-2 in vitro infectivity reduction assay. Neutralizing activity in CVS was associated with the presence of IgG and/or IgA antibodies to HSV-1 and/or to HSV-2 by ECL-WB. Among women whose CVS showed HSV-2-neutralizing activity, the specific activity of HSV-specific neutralizing antibodies was substantially (fivefold) higher in HSV-2 DNA shedders than in nonshedders. In conclusion, HSV-specific antibodies are frequently detected in CVS of asymptomatic African women seropositive for HSV-1 and HSV-2. A subset of these women had functional neutralizing activity against HSV-2 in their CVS. The origin of these antibodies and their role in HSV-2 disease of the female genital tract remain to be determined.


Revista CERES ◽  
2014 ◽  
Vol 61 (2) ◽  
pp. 280-283 ◽  
Author(s):  
Marcus Rebouças Santos ◽  
Hanna Carolina Campos Ferreira ◽  
Marcos Antônio dos Santos ◽  
Giuliana Loreto Saraiva ◽  
Natália Filardi Tafuri ◽  
...  

Bovine herpesvirus 1 (BoHV-1) causes major losses in worldwide livestock, affecting the respiratory and reproductive tracts of bovine. In the past decades, the number of cases in Brazil has been gradually increasing. Therefore, it is important to assess the distribution of infection in different regions of the country. In the state of Espírito Santo (ES) the BoHV 1 infection rate in dairy cattle herds is unknown. Thus, the aim of this study was to detect neutralizing antibodies against BoHV-1 in serum samples from 1,161 non-vaccinated cows from 59 dairy cattle herds in 23 municipalities of the Metropolitan, North, Northwest and South macro-regions. The identification of seropositive cows was evaluated by the virus neutralization test. The results showed that of all serum samples evaluated 775 (66.75%) had neutralizing antibodies against BoHV-1. Moreover, all herds were found positive; however, the percentage of positive cows varied among regions; 49.06%, 62.15%, 67.21% and 80.04% for the Metropolitan, South, North and Northwest macro-regions, respectively. In this study, the results clearly indicate the dissemination of the viral agent in dairy cattle in the ES state, requiring the monitoring and control of diseases related to BoHV-1 infection.


1989 ◽  
Vol 31 (4) ◽  
pp. 279-285 ◽  
Author(s):  
M.E. Camargo ◽  
Maria Emilia G. Moura ◽  
P.G. Leser

In search of an efficient but simple, low cost procedure for the serodiagnosis of Toxoplasmosis, especially suited for routine laboratories facing technical and budget limitations as in less developed countries, the diagnostic capability of Hematoxo® , an hemagglutination test for toxoplasmosis, was evaluated in relation to a battery of tests including IgG- and IgM-immunofluorescence tests, hemagglutination and an IgM-capture enzymatic assay. Detecting a little as 5 I.U. of IgG antitoxoplasma antibodies, Hematoxo® showed a straight agreement as to reactivity and non-reactivity for the 443 non-reactive and the 387 reactive serum samples, included in this study. In 23 cases presenting a serological pattern of acute toxoplasmosis and showing IgM antibodies, Hematoxo® could detect IgM antibodies in 18, indicated by negativation or a significant decrease in titers as a result of treating samples with 2-mercapto-ethanol. However, a neat increase in sensitivity for IgM specific antibodies could be achieved by previously removing IgG from the sample, as demonstrated in a series of acute toxoplasmosis sera. A simple procedure was developed for this purpose, by reconstituting a lyophilized suspension of Protein A - rich Staphylococcus with the lowest serum dilution to be tested. Of low cost and easy to perform, Hematoxo® affords not only a practical qualitative procedure for screening reactors and non-reactors, as in prenatal services, but also quantitative assays that permit to titrate antibodies as well as to identify IgM antibodies.


2017 ◽  
Vol 47 (10) ◽  
Author(s):  
Mathias Martins ◽  
João Motta de Quadros ◽  
Eduardo Furtado Flores ◽  
Rudi Weiblen

ABSTRACT: The antibody response to rabies virus (RABV) induced by commercial vaccines in heifers was investigated. For this, 84 heifers were vaccinated twice (30 days interval) with each of four vaccines (G1 = 14 animals; G2 = 24; G3 = 22 and G4 = 24) and received a booster vaccination 360 days later. Serum samples collected at different intervals after vaccination and 30 days after booster were submitted to a virus neutralizing (VN) assay for RABV antibodies. Thirty days after the second vaccine dose, 92% of the immunized animals presented VN titers ≥0.5UI/mL (geometric medium titers [GMT] 1.7 to 3.8UI/mL). At the day of the booster (360 days post-vaccination); however, the percentage of animals harboring antibody titers ≥0.5UI/mL had dropped to 31% (0-80% of the animals, depending on the vaccine), resulting in lower GMT (0.1 to 0.6UI/mL). Booster vaccination at day 360 resulted in a detectable anamnestic response in all groups, resulting in 83% of animals (65 to 100%) harboring VN titers ≥0.5UI/mL thirty days later (GMT 0.6 to 4.3UI/mL). These results indicated that these vaccines were able to induce an adequate anti-RABV response in all animals after prime vaccination (and after booster as well). However, the titers decreased, reaching titers <0.5UI/mL in approximately 70% of animals within the interval before the recommended booster. Thus, booster vaccination for rabies in cattle using the current vaccines should be performed before the recommended one-year interval, as to maintain neutralizing antibodies levels in most vaccinated animals.


Sign in / Sign up

Export Citation Format

Share Document