Global similarity based ontology to enhance the quality of big and distributed RDF data

Author(s):  
Lamrani Kaoutar ◽  
Ghadi Abderrahim
Keyword(s):  
Rdf Data ◽  
F1000Research ◽  
2019 ◽  
Vol 8 ◽  
pp. 1677
Author(s):  
Toshiaki Katayama ◽  
Shuichi Kawashima ◽  
Gos Micklem ◽  
Shin Kawano ◽  
Jin-Dong Kim ◽  
...  

Publishing databases in the Resource Description Framework (RDF) model is becoming widely accepted to maximize the syntactic and semantic interoperability of open data in life sciences. Here we report advancements made in the 6th and 7th annual BioHackathons which were held in Tokyo and Miyagi respectively. This review consists of two major sections covering: 1) improvement and utilization of RDF data in various domains of the life sciences and 2) meta-data about these RDF data, the resources that store them, and the service quality of SPARQL Protocol and RDF Query Language (SPARQL) endpoints. The first section describes how we developed RDF data, ontologies and tools in genomics, proteomics, metabolomics, glycomics and by literature text mining. The second section describes how we defined descriptions of datasets, the provenance of data, and quality assessment of services and service discovery. By enhancing the harmonization of these two layers of machine-readable data and knowledge, we improve the way community wide resources are developed and published.  Moreover, we outline best practices for the future, and prepare ourselves for an exciting and unanticipatable variety of real world applications in coming years.


Author(s):  
Omid Zanganeh ◽  
Komal Komal ◽  
Nandita Bhattacharjee ◽  
David Albrecht ◽  
Bala Srinivasan

The conventional method of fingerprint alignment using reference points does not work well for partial fingerprints due to the limited or non-availability of reference points. Moreover, matching of partial fingerprints using existing techniques is challenging as partial fingerprints lack enough distinguishing information. Even if fingerprints consists of sufficient information, the varying quality of different parts of fingerprint affects recognition process. In this paper, a new paradigm in the form of region-based approach that uses all available fingerprint ridge structure for aligning the fingerprints is proposed. Additionally, a new metric to compute individual local region similarity based on region’s quality, size and consistency of its neighbouring regions is proposed and used in deriving the global similarity for matching process. Although the proposed approach is computationally intensive, yet, the error rate is close to zero as the experimental results shows. The method is most suitable in applications where perfect identification is required such as forensic investigations.  


Author(s):  
K. T. Tokuyasu

During the past investigations of immunoferritin localization of intracellular antigens in ultrathin frozen sections, we found that the degree of negative staining required to delineate u1trastructural details was often too dense for the recognition of ferritin particles. The quality of positive staining of ultrathin frozen sections, on the other hand, has generally been far inferior to that attainable in conventional plastic embedded sections, particularly in the definition of membranes. As we discussed before, a main cause of this difficulty seemed to be the vulnerability of frozen sections to the damaging effects of air-water surface tension at the time of drying of the sections.Indeed, we found that the quality of positive staining is greatly improved when positively stained frozen sections are protected against the effects of surface tension by embedding them in thin layers of mechanically stable materials at the time of drying (unpublished).


Author(s):  
L. D. Jackel

Most production electron beam lithography systems can pattern minimum features a few tenths of a micron across. Linewidth in these systems is usually limited by the quality of the exposing beam and by electron scattering in the resist and substrate. By using a smaller spot along with exposure techniques that minimize scattering and its effects, laboratory e-beam lithography systems can now make features hundredths of a micron wide on standard substrate material. This talk will outline sane of these high- resolution e-beam lithography techniques.We first consider parameters of the exposure process that limit resolution in organic resists. For concreteness suppose that we have a “positive” resist in which exposing electrons break bonds in the resist molecules thus increasing the exposed resist's solubility in a developer. Ihe attainable resolution is obviously limited by the overall width of the exposing beam, but the spatial distribution of the beam intensity, the beam “profile” , also contributes to the resolution. Depending on the local electron dose, more or less resist bonds are broken resulting in slower or faster dissolution in the developer.


Author(s):  
G. Lehmpfuhl

Introduction In electron microscopic investigations of crystalline specimens the direct observation of the electron diffraction pattern gives additional information about the specimen. The quality of this information depends on the quality of the crystals or the crystal area contributing to the diffraction pattern. By selected area diffraction in a conventional electron microscope, specimen areas as small as 1 µ in diameter can be investigated. It is well known that crystal areas of that size which must be thin enough (in the order of 1000 Å) for electron microscopic investigations are normally somewhat distorted by bending, or they are not homogeneous. Furthermore, the crystal surface is not well defined over such a large area. These are facts which cause reduction of information in the diffraction pattern. The intensity of a diffraction spot, for example, depends on the crystal thickness. If the thickness is not uniform over the investigated area, one observes an averaged intensity, so that the intensity distribution in the diffraction pattern cannot be used for an analysis unless additional information is available.


Author(s):  
K. Shibatomi ◽  
T. Yamanoto ◽  
H. Koike

In the observation of a thick specimen by means of a transmission electron microscope, the intensity of electrons passing through the objective lens aperture is greatly reduced. So that the image is almost invisible. In addition to this fact, it have been reported that a chromatic aberration causes the deterioration of the image contrast rather than that of the resolution. The scanning electron microscope is, however, capable of electrically amplifying the signal of the decreasing intensity, and also free from a chromatic aberration so that the deterioration of the image contrast due to the aberration can be prevented. The electrical improvement of the image quality can be carried out by using the fascionating features of the SEM, that is, the amplification of a weak in-put signal forming the image and the descriminating action of the heigh level signal of the background. This paper reports some of the experimental results about the thickness dependence of the observability and quality of the image in the case of the transmission SEM.


Author(s):  
John H. Luft

With information processing devices such as radio telescopes, microscopes or hi-fi systems, the quality of the output often is limited by distortion or noise introduced at the input stage of the device. This analogy can be extended usefully to specimen preparation for the electron microscope; fixation, which initiates the processing sequence, is the single most important step and, unfortunately, is the least well understood. Although there is an abundance of fixation mixtures recommended in the light microscopy literature, osmium tetroxide and glutaraldehyde are favored for electron microscopy. These fixatives react vigorously with proteins at the molecular level. There is clear evidence for the cross-linking of proteins both by osmium tetroxide and glutaraldehyde and cross-linking may be a necessary if not sufficient condition to define fixatives as a class.


Author(s):  
Russell L. Steere ◽  
Eric F. Erbe ◽  
J. Michael Moseley

We have designed and built an electronic device which compares the resistance of a defined area of vacuum evaporated material with a variable resistor. When the two resistances are matched, the device automatically disconnects the primary side of the substrate transformer and stops further evaporation.This approach to controlled evaporation in conjunction with the modified guns and evaporation source permits reliably reproducible multiple Pt shadow films from a single Pt wrapped carbon point source. The reproducibility from consecutive C point sources is also reliable. Furthermore, the device we have developed permits us to select a predetermined resistance so that low contrast high-resolution shadows, heavy high contrast shadows, or any grade in between can be selected at will. The reproducibility and quality of results are demonstrated in Figures 1-4 which represent evaporations at various settings of the variable resistor.


Sign in / Sign up

Export Citation Format

Share Document