scholarly journals Estimation of Inelastic Interstorey Drift for OSB/Gypsum Sheathed Cold-Formed Steel Structures under Collapse Level Earthquakes

2019 ◽  
Vol 2019 ◽  
pp. 1-15
Author(s):  
Xiangbin Liu ◽  
Hanheng Wu ◽  
Liurui Sang ◽  
Lu Sui ◽  
Congcong Xu

In order to estimate the inelastic interstorey drift of cold-formed steel (CFS) framed structures under collapse level earthquakes, the deflection amplification factor ηp is employed in this paper to compute the maximum interstorey drift ratio (IDRmax) from an elastic analysis. For this purpose, a series of CFS wall specimens were tested under cyclic horizontal loads, and then the hysteresis model of the walls was put forward by test results. In terms of the hysteresis model, a large quantity of elastic-plastic time-history analysis of CFS building structures was conducted based on the storey shear-type model. Furthermore, the deflection amplification factor ηp for estimating IDRmax and the parameters were analyzed. The results indicate that the deflection amplification factor ηp is highly dependent on yielding coefficient of storey shear force ξy, storey number N, period of structure T, and ground acceleration records GA. Eventually, an approximate ξy-N-ηp relationship for estimating the deflection amplification factor ηp is proposed in this paper, which can be used for seismic design in practices.

2021 ◽  
pp. 136943322110439
Author(s):  
Mussa Mahmoudi ◽  
Mohammad Jalili Sadr Abad

Researchers in the field of earthquake engineering are always looking for new ways to improve the seismic behavior of structures. The buckling-restrained brace (BRB) is one of these exciting innovations that are employed to increase the ductility capacity of traditional steel braced frames. Understanding the nonlinear response of these novel systems in estimating maximum displacements due to an earthquake has been of significant importance for structural designers. Accordingly, this research is carried out to study of deflection amplification factor ( C d) in BRBs, which have recently been presented in seismic design provisions as one of the seismic lateral-resisting systems. To this end, five 3-, 5-, 7-, 10-, and 15-story BRBs are modeled in the software framework of OpenSees. Ground motion simulation is performed by selecting several scaled earthquake records, and the values of elastic and ultimate displacements of structural systems are computed through pushover and nonlinear time-history analyses. The results showed that the deflection amplification factor suggested within famous building codes (such as ASCE-7-16) compared to the obtained values is, in some cases, for certainty; conversely, it is underestimated under some conditions. In fact, the findings indicate that the magnitude of C d in these systems is strongly related to the height of the building.


2020 ◽  
Vol 2 (1) ◽  
pp. 40-47
Author(s):  
Anand Dev Bhatt

 Inter-storey drift is an important parameter of structural behavior in seismic analysis of buildings. Pounding effect in building simply means collision between adjacent buildings due to earthquake load caused by out of phase vibration of adjacent buildings. There is variation in inter-storey drift of adjacent buildings during pounding case and no pounding case. The main objective of this research was to compare the inter-storey drift of general adjacent RC buildings in pounding and no pounding case. For this study two adjacent RC buildings having same number of stories have been considered. For pounding case analysis there is no gap in between adjacent buildings and for no pounding case analysis there is sufficient distance between adjacent buildings. The model consists of adjacent buildings having 4 and 4 stories but unequal storey height. Both the buildings have same material & sectional properties. Fast non-linear time history analysis was performed by using El-centro earthquake data as ground motion. Adjacent buildings having different overall height were modelled in SAP 2000 v 15 using gap element for pounding case. Finally, analysis was done and inter-storey drift was compared. It was found that in higher building inter-storey drift is greater in no pounding case than in pounding case but in adjacent lower height building the result was reversed. Additionally, it was found that in general residential RC buildings maximum inter-storey drift occurs in 2nd floor.


2011 ◽  
Vol 255-260 ◽  
pp. 2341-2344
Author(s):  
Mohammad Saeed Masoomi ◽  
Siti Aminah Osman ◽  
Ali Jahanshahi

This paper presents the performance of base-isolated steel structures under the seismic load. The main goals of this study are to evaluate the effectiveness of base isolation systems for steel structures against earthquake loads; to verify the modal analysis of steel frame compared with the hand calculation results; and development of a simulating method for base-isolated structure’s responses. Two models were considered in this study, one a steel structure with base-isolated and the other without base-isolated system. The nonlinear time-history analysis of both structures under El Centro 1940 seismic ground motion was used based on finite element method through SAP2000. The mentioned frames were analyzed by Eigenvalue method for linear analysis and Ritz-vector method for nonlinear analysis. Simulation results were presented as time-acceleration graphs for each story, period and frequency of both structures for the first three modes.


2018 ◽  
Vol 763 ◽  
pp. 295-300 ◽  
Author(s):  
Khaled Saif ◽  
Chin Long Lee ◽  
Trevor Yeow ◽  
Gregory A. MacRae

Nonlinear time history analyses of SDOF bridge columns with elasto-plastic flexural behaviour which are subject to eccentric gravity loading are conducted to quantify the effect of ratchetting. Peak and residual displacements were used as indicators of the degree of ratchetting. The effects of member axial loads and design force reduction factors were also investigated. It was shown that displacement demands increased with increasing eccentric moment. For eccentric moment of 30% of the yield moment, the average maximum and residual displacements increase by 4.2 and 3.8 times the maximum displacement, respectively, which the engineers calculate using static methods without considering ratchetting effect. Design curves for estimating the displacement demands for different eccentric moments are also developed. The current NZ1170.5 (2016) provisions were found to be inadequate in estimating the maximum displacement for steel structures, and hence, new provisions for steel structures should be presented.


2021 ◽  
Author(s):  
Aleksei Kondratenko ◽  
Alper Kanyilmaz ◽  
Carlo Andrea Castiglioni ◽  
Francesco Morelli ◽  
Mohsen Kohrangi

Abstract Automated Multi-Depth Shuttle Warehouses (AMSWs) are compact storage systems that provide a large surface occupation and therefore maximum storage density. AMSWs represent the future of storage technology, providing substantial savings in terms of cost, space, and energy with respect to traditional warehouses. Currently, designers refer to the standard building codes for the seismic design of AMSWs. Since structural characteristics of AMSWs are considerably different from the steel structures of typical buildings, this current approach used by designers is questionable in terms of safety and efficiency. In this article, the behavior of 5 AMSW structures has been studied performing 150 time-history analyses by direct integration including P-Delta effects. Demand/capacity ratios calculated for each element showed the dominance of the brittle failure mechanism in AMSWs subjected to low-to-moderate seismic actions. These mechanisms mainly took place in upright columns and their base connections prior to the activation of ductile energy dissipation mechanisms of the structure. Based on the results, further improvements have been recommended for the future design provisions, which may lead to a safer seismic design of AMSWs.


2021 ◽  
Vol 885 ◽  
pp. 127-132
Author(s):  
Sarmad Shakeel ◽  
Alessia Campiche

The current edition of Eurocode 8 does not cover the design of the Cold-Formed steel (CFS) building structures under the seismic design condition. As part of the revision process of Euro-code 8 to reflect the outcomes of extensive research carried out in the past decade, University of Naples “Federico II” is involved in the validation of existing seismic design criteria and development of new rules for the design of CFS systems. In particular, different types of Lateral Force Resisting System (LFRS) are analyzed that can be listed in the second generation of Eurocode 8. The investigated LFRS’s include CFS strap braced walls and CFS shear walls with steel sheets, wood, or gypsum sheathing. This paper provides the background information on the research works and the reference design standards, already being used in some parts of the world, which formed the basis of design criteria for these LFRS systems. The design criteria for the LFRS-s common to CFS buildings would include rules necessary for ensuring the dissipative behavior, appropriate values of the behavior factor, guidelines to predict the design strength, geometrical and mechanical limitations.


2018 ◽  
Vol 763 ◽  
pp. 1067-1076 ◽  
Author(s):  
Luigi di Sarno ◽  
Fabrizio Paolacci ◽  
Anastasios G. Sextos

Numerous existing steel framed buildings located in earthquake prone regions world-wide were designed without seismic provisions. Slender beam-columns, as well as non-ductile beam-to-column connections have been employed for multi-storey moment-resisting frames (MRFs) built before the 80’s. Thus, widespread damage due to brittle failure has been commonly observed in the past earthquakes for steel MRFs. A recent post-earthquake survey carried out in the aftermath of the 2016-2017 Central Italy seismic swarm has pointed out that steel structures may survive the shaking caused by several main-shocks and strong aftershocks without collapsing. Inevitably, significant lateral deformations are experienced, and, in turn, non-structural components are severely damaged thus inhibiting the use of the steel building structures. The present papers illustrates the outcomes of a recent preliminary numerical study carried out for the case of a steel MRF building located in Amatrice, Central Italy, which experienced a series of ground motion excitations suffering significant damage to the masonry infills without collapsing. A refined numerical model of the sample structure has been developed on the basis of the data collected on site. Given the lack of design drawings, the structure has been re-designed in compliance with the Italian regulations imposed at the time of construction employing the allowable stress method. The earthquake performance of the case study MRF has been then investigated through advanced nonlinear dynamic analyses and its structural performance has been evaluated according to Eurocode 8-Part 3 for existing buildings. The reliability of the codified approaches has been evaluated and possible improvements emphasized.


2018 ◽  
Vol 15 (5) ◽  
pp. 575-583
Author(s):  
Ka Yee Kok ◽  
Hieng Ho Lau ◽  
Thanh Duoc Phan ◽  
TIina Chui Huon Ting

Purpose This paper aims to present the design optimisation using genetic algorithm (GA) to achieve the highest strength to weight (S/W) ratio, for cold-formed steel residential roof truss. Design/methodology/approach The GA developed in this research simultaneously optimises roof pitch, truss configurations, joint coordinates and applied loading of typical dual-pitched symmetrical residential roof truss. The residential roof truss was considered with incremental uniform distributed loading, in both gravitational and uplift directions. The structural analyses of trusses were executed in this GA using finite element toolbox. The ultimate strength and serviceability of trusses were checked through the design formulation implemented in GA, according to the Australian standard, AS/NZS 4600 Cold-formed Steel Structures. Findings An optimum double-Fink roof truss which possess highest S/W ratio using GA was determined, with optimum roof pitch of 15°. The optimised roof truss is suitable for industrial application with its higher S/W ratio and cost-effectiveness. The combined methodology of multi-level optimisation and simultaneous optimisation developed in this research could determine optimum roof truss with consistent S/W ratio, although with huge GA search space. Research limitations/implications The sizing of roof truss member is not optimised in this paper. Only single type of cold-formed steel section is used throughout the whole optimisation. The design of truss connection is not considered in this paper. The corresponding connection costs are not included in the proposed optimisation. Practical implications The optimum roof truss presented in this paper is suitable for industrial application with higher S/W ratio and lower cost, in either gravitational or uplift loading configurations. Originality/value This research demonstrates the approaches in combining multi-level optimisation and simultaneous optimisation to handle large number of variables and hence executed an efficient design optimisation. The GA designed in this research determines the optimum residential roof truss with highest S/W ratio, instead of lightest truss weight in previous studies.


Sign in / Sign up

Export Citation Format

Share Document