scholarly journals Peri-Implant Tissue Adaptation after Implant Rehabilitation with Shoulderless Abutments with 24 Months of Follow-Up

2021 ◽  
Vol 2021 ◽  
pp. 1-8
Author(s):  
Luca Casula ◽  
Alex Gillone ◽  
Davide Musu

An 11-year-old girl presented with agenesis of the maxillary lateral incisors. Orthodontic treatment was performed to close the midline diastema and create adequate space between the central incisors and canines to replace the missing maxillary lateral incisors on both sides. Two-piece implants were placed, and shoulderless abutments were prepared following the “biologically oriented preparation technique” (BOPT) protocol. The soft tissues were allowed to heal directly on the prosthetic emergence profile of the interim crown restorations after implant exposure. Two months later, the gingival tissue adapted to the prosthetic components in a specular manner. No complications were noted at 24 months. The BOPT protocol, originally described for natural teeth, may be applied to dental implants with shoulderless abutments.

Author(s):  
Odontuya Dorj ◽  
Hsi-Kuei Lin ◽  
Eisner Salamanca ◽  
Yu-Hwa Pan ◽  
Yi-Fan Wu ◽  
...  

Background: The objective of this study was to evaluate the effects of opposite tooth conditions on change in marginal bone level (MBL) around submerged dental implants. Materials and methods: The study included healthy patients with one or two implants. Structures opposite implants were either natural teeth (NT) or fixed restorations (FRs). MBLs were measured on digital periapical radiographs at the mesial and distal aspects of each implant. Results: Sixty implants were inserted by the 3-year follow-up. Mean MBLs for NT were 0.21 ± 0.33 mm before prosthetic loading and 0.30 ± 0.41 mm 3 years later (p = 0.001). Mean MBLs with FRs were 0.36 ± 0.45 mm before loading and 0.53 ± 0.50 mm 3 years later (p < 0.001). Changes in mean MBL from the 6-month follow-up to the 1- and 3-year follow-ups were statistically significant (p < 0.01) for implants opposite NT. However, changes in mean MBL from the 6-month follow-up to the 1-year (p = 0.161) and 3-year follow-ups (p = 1.000) were not significant for implants opposite FRs. Between baseline and the 3-year follow-up, MBL change was relatively small and did not differ regarding NT and FRs. Conclusion: Bone loss was greater if submerged dental implants were opposed by FRs. MBLs around submerged implants continued to change after 3 years if NT opposed implants.


2016 ◽  
Vol 86 (5) ◽  
pp. 713-720 ◽  
Author(s):  
Sung-Hwan Choi ◽  
Kyung-Keun Shi ◽  
Jung-Yul Cha ◽  
Young-Chel Park ◽  
Kee-Joon Lee

ABSTRACT Objective:  To evaluate the stability of nonsurgical miniscrew-assisted rapid maxillary expansion (MARME) in young adults with a transverse maxillary deficiency. Materials and Methods:  From a total of 69 adult patients who underwent MARME followed by orthodontic treatment with a straight-wire appliance, 20 patients (mean age, 20.9 ± 2.9 years) with follow-up records (mean, 30.2 ± 13.2 months) after debonding were selected. Posteroanterior cephalometric records and dental casts were obtained at the initial examination (T0), immediately after MARME removal (T1), immediately after debonding (T2), and at posttreatment follow-up (T3). Results:  Suture separation was observed in 86.96% of subjects (60/69). An increase in the maxillary width (J-J; 1.92 mm) accounted for 43.34% of the total expansion with regard to the intermolar width (IMW) increase (4.43 mm; P &lt; .001) at T2. The amounts of J-J and IMW posttreatment changes were −0.07 mm (P &gt; .05) and −0.42 mm (P  =  .01), respectively, during retention. The postexpansion change in middle alveolus width increased with age (P &lt; .05). The postexpansion change of interpremolar width (IPMW) was positively correlated with the amount of IPMW expansion (P &lt; .05) but not with IMW. The changes of the clinical crown heights in the maxillary canines, first premolars, and first molars were not significant at each time point. Conclusions:  Nonsurgical MARME can be a clinically acceptable and stable treatment modality for young adults with a transverse maxillary deficiency.


2021 ◽  
Vol 7 (1) ◽  
Author(s):  
George Deryabin ◽  
Simonas Grybauskas

Abstract Background The purpose of this study was to analyze medium-to-long-term implant success and survival rates, and lower lip sensory disturbance after placement of dental implants with simultaneous inferior alveolar nerve (IAN) repositioning. Methods Fifteen patients (3 men, 12 women) treated in two centers were included in this retrospective study. The ages of the participants ranged from 19 to 68. A total of 48 dental implants were placed in 23 posterior mandibular segments simultaneously with IAN transposition or lateralization. The residual bone above the IAN ranged from 0.5 to 7.0 mm. Crestal bone changes were measured using cone beam computed tomography (CBCT) images. Disturbance of the IAN was evaluated subjectively using a modified questionnaire. Results The healing process was uneventful in fourteen patients. In one patient, spontaneous fracture of the operated mandible occurred on tenth day after the surgery. The implant in the fracture line was removed at the time of open reduction and fixation. One more implant was lost after 5 years of loading. Therefore, the overall dental implant survival rate was 95.8%, whereas all implants in function were judged as successful after a follow-up period of 1 to 10 years. Transient neurosensory disturbances (ND) were observed in all patients who underwent IAN lateralization and IAN transposition. At follow-up times of 3 years, 5 years, and 10 years, weak hypoesthesia remained in two subjects treated with IAN transposition. None of the patients developed neuropathic pain after the procedure. Conclusions Within the limitations of this study, we conclude that reconstruction of severely resorbed mandibles with dental implants in conjunction with IAN repositioning is an effective and reliable technique. Although neurosensory disturbances are the most common complication after surgery, they tend to resolve over time. Advanced surgical skills are required to perform this technique.


Author(s):  
Riccardo Scaringi ◽  
Michele Nannelli ◽  
Alessio Franchina ◽  
Giuseppe Lizio ◽  
Luigi V. Stefanelli ◽  
...  

CAD/CAM technology can enhance the dentistry application of ceramic materials that meet the more relevant biocompatibility and aesthetics demands. In implant-borne prosthesis rehabilitation, yttria-stabilized zirconia appeared to be a valid alternative to metal-alloys and titanium, with comparable mechanical properties and even better interaction with bone and soft tissues. The improvement of monolithic CAD/CAM manufacturing allows for a reliable, predictable, and rapid workflow that can correspond to a holistic treatment philosophy associated with zirconia fixtures. This reported clinical case highlights the advantages of this approach in resolving particularly functionally and aesthetically complex situations. A 40-year-old patient with permanent canine impaction and the persistence of a deciduous tooth compromised by caries was successfully rehabilitated with the surgical removal of the enclosed tooth, the seating of a mono-phase zirconia implant after the deciduous extraction and its loading with a zirconia single crown, without any clinical or radiographical alteration up to seven years follow-up.


2021 ◽  
Vol 22 (3) ◽  
pp. 1067
Author(s):  
Georgios Romanos ◽  
Gerard Fischer ◽  
Rafael Delgado-Ruiz

The objective of this review was to analyze the process of wear of implants leading to the shedding of titanium particles into the peri-implant hard and soft tissues. Titanium is considered highly biocompatible with low corrosion and toxicity, but recent studies indicate that this understanding may be misleading as the properties of the material change drastically when titanium nanoparticles (NPs) are shed from implant surfaces. These NPs are immunogenic and are associated with a macrophage-mediated inflammatory response by the host. The literature discussed in this review indicates that titanium NPs may be shed from implant surfaces at the time of implant placement, under loading conditions, and during implant maintenance procedures. We also discuss the significance of the micro-gap at the implant-abutment interface and the effect of size of the titanium particles on their toxicology. These findings are significant as the titanium particles can have adverse effects on local soft and hard tissues surrounding implants, implant health and prognosis, and even the health of systemic tissues and organs.


2021 ◽  
Vol 10 (5) ◽  
pp. 940
Author(s):  
Jakub Hadzik ◽  
Paweł Kubasiewicz-Ross ◽  
Izabela Nawrot-Hadzik ◽  
Tomasz Gedrange ◽  
Artur Pitułaj ◽  
...  

Short 6 mm dental implants are considered as an alternative to the maxillary sinus elevation and bone augmentation procedure where there is a reduced alveolar ridge height. The aim of this study was to compare the implant survival rate between short dental implants (6 mm) and regular length implants (11–13 mm) when placed in combination with bone grafting and loaded with a single non splinted crown, seven years after placing the implant. It was conducted as a controlled clinical study of 30 patients with partial edentulism in the posterior maxilla. The protocol included radiological and clinical evaluation of the C/I ratio (length of the superstructure divided by the length of the implant crestal part), marginal bone level (MBL), ultrasonography measurement of soft tissue surrounding implant (STT), patient-reported outcomes, and biological and technical complications. A total number of 28 implants (93%) remained integrated during follow-up period. MBL of 0.50 and 0.52 mm was observed for short implants and regular implants, respectively. MBL was checked for correlation with STT, and a negative correlation was found between MBL: STT. Our study has demonstrated a significantly lower implant survival rate for short implants compared to regular implants (87% compared to 100%). Despite the loss of several implants, good clinical results were achieved in the remaining implants in both groups. It is, therefore, worth considering short implants as an alternative to regular implants with a sinus lift surgery.


2021 ◽  
pp. 239719832110043
Author(s):  
Miguel Angel Garcés Villalá ◽  
Carolina Zorrilla Albert

Introduction: Limited cutaneous systemic sclerosis with special manifestations (calcinosis cutis, Raynaud’s phenomenon, esophageal dysmotility, sclerodactyly, and telangiectasia) is part of the group of connective tissue diseases, these rare autoimmune systemic pathologies cause thickening and hardening of tissues in different parts of the body and can lead to complex disorders. Oral manifestations of systemic sclerosis may include limited ability to open the mouth, xerostomia, periodontal disease, enlarged periodontal ligament, and bone resorption of the jaw. Case Description: A 54-year-old Caucasian patient presented with oral pain, swallowing, phonation and chewing difficulties associated with dental instability, hygiene/handling difficulties and her main problem with microstomia, which prevented her from removing the skeletal prosthesis for 4 years, depriving her of social life. Gradual treatment with dental implants was diagnosed and planned to support a fixed total denture adapted to the ridge with self-cleaning characteristics. After implant insertion, panoramic radiographs with standardized parameters were taken to compare crestal bone levels at the time of prosthesis placement and with 10 years of follow-up. Conclusion: The average crestal bone loss of the 12 implants after the 10 years of follow-up was 1.26 mm for the maxilla and 1.17 mm for the mandible. The survival of the 12 support implants of two total fixed prostheses in a clinical/radiographic follow-up of 10 years was 100%. After 10 years of follow-up, the 12 implants inserted had a bone loss similar to that of healthy patients and no pathologies were registered, recovering function, aesthetics, and self-esteem. This therapy must be implemented before the interincisal distance decreases to 30 mm to allow intraoral surgical/prosthetic access. Implant-supported total fixed rehabilitation is a viable, predictable, and recommended therapy in patients with limited cutaneous systemic sclerosis.


2021 ◽  
Vol 11 (5) ◽  
pp. 2176
Author(s):  
Krzysztof Dowgierd ◽  
Rafal Pokrowiecki ◽  
Maciej Borowiec ◽  
Marcin Kozakiewicz ◽  
Dominika Smyczek ◽  
...  

Extended postoperative mandibular reconstructions due to orofacial disease involving the temporomandibular joint (TMJ) in immature patients remain a challenge as a result of ongoing growth, which is usually affected by the disease and treatment. Current reconstructive techniques based fully on alloplastic total joint replacement fail to meet fully the anatomical and functional requirements for the masticatory system and speech development. Fourteen children aged 12.6 ± 2.6 with tumors or congenital deformities affecting the mandible and TMJ were included in the study. Radical surgical treatment according to our own protocol was performed through microvascular anastomotic flap reconstruction of the soft tissues and bones, together with total TMJ custom replacements. Follow-up lasted 2–6 years. During the follow-up, increases in the mandible body (13% growth) and ramus (12% growth) were observed, both of which were related (p < 0.001). This is the first report concerning the immediate reconstruction of the mandible with ramus and total TMJ in children and adolescents that combines a free vascularized graft and total individual prosthesis of the TMJ. The presented technique enabled optimal function of the TMJ, growth of the mandible, and further rehabilitation of the patients. The technique was demonstrated to be safe, reliable, and provide good functional and cosmetic outcomes.


2020 ◽  
Vol 9 (12) ◽  
pp. 3943
Author(s):  
João Caramês ◽  
Ana Catarina Pinto ◽  
Gonçalo Caramês ◽  
Helena Francisco ◽  
Joana Fialho ◽  
...  

This retrospective study evaluated the survival rate of short, sandblasted acid-etched surfaced implants with 6 and 8 mm lengths with at least 120 days of follow-up. Data concerning patient, implant and surgery characteristics were retrieved from clinical records. Sandblasted and acid-etched (SLA)-surfaced tissue-level 6 mm (TL6) or 8 mm (TL8) implants or bone-level tapered 8 mm (BLT8) implants were used. Absolute and relative frequency distributions were calculated for qualitative variables and mean values and standard deviations for quantitative variables. A Cox regression model was performed to verify whether type, length and/or width influence the implant survival. The cumulative implant survival rate was assessed by time-to-event analyses (Kaplan–Meier estimator). In all, 513 patients with a mean age of 58.00 ± 12.44 years received 1008 dental implants with a mean follow-up of 21.57 ± 10.77 months. Most implants (78.17%) presented a 4.1 mm diameter, and the most frequent indication was a partially edentulous arch (44.15%). The most frequent locations were the posterior mandible (53.97%) and the posterior maxilla (31.55%). No significant differences were found in survival rates between groups of type, length and width of implant with the cumulative rate being 97.7% ± 0.5%. Within the limitations of this study, the evaluated short implants are a predictable option with high survival rates during the follow-up without statistical differences between the appraised types, lengths and widths.


Sign in / Sign up

Export Citation Format

Share Document