Conjugate heat transfer study of backdisc cooling of a radial turbine

Author(s):  
MA Chao ◽  
LU Kangbo ◽  
LI Wenjiao

Radial turbines used in turbochargers and micro-turbines are subjected to high inlet temperature. This creates high thermal stress in the turbines, and possible creep of turbine inducer blades, and can reduce turbines’ reliability. With the ever-stringent engine emission regulations and the continuous drive for engine power density, turbine inlet temperature is significantly increased recently and the risk of thermo-mechanical failure of turbine rotor is heightened. To solve this problem, an innovative turbine cooling method is proposed by injecting a small amount of compressor or intercooler discharge air onto the upper backdisc region of turbine rotor to cool the disc and the inducer blades. A conjugate heat transfer simulation was carried out to investigate the effects of this cooling method with a turbocharger turbine. Flow conditions and geometric configurations were investigated for their influences on the cooling effectiveness of the method. The results show that using the compressor discharger air after intercooler with only 0.5–2.0% of turbine mass flow, the averaged cooling efficiency of the turbine backdisc is promoted by 23–43%; only four to six jets may be needed to cool the entire backdisc; and turbine efficiency is reduced by less than 1% point.

2021 ◽  
pp. 1-20
Author(s):  
Hongyan Bu ◽  
Yufeng Yang ◽  
Liming Song ◽  
Jun Li

Abstract The gas turbine endwall is bearing extreme thermal loads with the rapid increase of turbine inlet temperature. Therefore, the effective cooling of turbine endwalls is of vital importance for the safe operation of turbines. In the design of endwall cooling layouts, numerical simulations based on conjugate heat transfer (CHT) are drawing more attention as the component temperature can be predicted directly. However, the computation cost of high-fidelity CHT analysis can be high and even prohibitive especially when there are many cases to evaluate such as in the design optimization of cooling layout. In this study, we established a multi-fidelity framework in which the data of low-fidelity CHT analysis was incorporated to help the building of a model that predicts the result of high-fidelity simulation. Based upon this framework, multi-fidelity design optimization of a validated numerical turbine endwall model was carried out. The high and low fidelity data were obtained from the computation of fine mesh and coarse mesh respectively. In the optimization, the positions of the film cooling holes were parameterized and controlled by a shape function. With the help of multi-fidelity modeling and sequentially evaluated designs, the cooling performance of the model endwall was improved efficiently.


Author(s):  
Jong-Shang Liu ◽  
Mark C. Morris ◽  
Malak F. Malak ◽  
Randall M. Mathison ◽  
Michael G. Dunn

In order to have higher power to weight ratio and higher efficiency gas turbine engines, turbine inlet temperatures continue to rise. State-of-the-art turbine inlet temperatures now exceed the turbine rotor material capability. Accordingly, one of the best methods to protect turbine airfoil surfaces is to use film cooling on the airfoil external surfaces. In general, sizable amounts of expensive cooling flow delivered from the core compressor are used to cool the high temperature surfaces. That sizable cooling flow, on the order of 20% of the compressor core flow, adversely impacts the overall engine performance and hence the engine power density. With better understanding of the cooling flow and accurate prediction of the heat transfer distribution on airfoil surfaces, heat transfer designers can have a more efficient design to reduce the cooling flow needed for high temperature components and improve turbine efficiency. This in turn lowers the overall specific fuel consumption (SFC) for the engine. Accurate prediction of rotor metal temperature is also critical for calculations of cyclic thermal stress, oxidation, and component life. The utilization of three-dimensional computational fluid dynamics (3D CFD) codes for turbomachinery aerodynamic design and analysis is now a routine practice in the gas turbine industry. The accurate heat-transfer and metal-temperature prediction capability of any CFD code, however, remains challenging. This difficulty is primarily due to the complex flow environment of the high-pressure turbine, which features high speed rotating flow, coupling of internal and external unsteady flows, and film-cooled, heat transfer enhancement schemes. In this study, conjugate heat transfer (CHT) simulations are performed on a high-pressure cooled turbine stage, and the heat flux results at mid span are compared to experimental data obtained at The Ohio State University Gas Turbine Laboratory (OSUGTL). Due to the large difference in time scales between fluid and solid, the fluid domain is simulated as steady state while the solid domain is simulated as transient in CHT simulation. This paper compares the unsteady and transient results of the heat flux on a high-pressure cooled turbine rotor with measurements obtained at OSUGTL.


2018 ◽  
Vol 2018 ◽  
pp. 1-18
Author(s):  
Muhammad Ishaq ◽  
Khalid Saifullah Syed ◽  
Zafar Iqbal ◽  
Ahmad Hassan

A DG-FEM based numerical investigation has been performed to explore the influence of the various geometric configurations on the thermal performance of the conjugate heat transfer analysis in the triangular finned double pipe heat exchanger. The computed results dictate that Nusselt number in general rises with values of the conductivity ratio of solid and fluid, for the specific configuration parameters considered here. However, the performance of these parameters shows strong influence on the conductivity ratio. Consequently, these parameters must be selected in consideration of the thermal resistance, for better design of heat exchanger.


Author(s):  
Akshay Khadse ◽  
Andres Curbelo ◽  
Ladislav Vesely ◽  
Jayanta S. Kapat

Abstract The first stage of turbine in a Brayton cycle faces the maximum temperature in the cycle. This maximum temperature may exceed creep temperature limit or even melting temperature of the blade material. Therefore, it becomes an absolute necessity to implement blade cooling to prevent them from structural damage. Turbine inlet temperatures for oxy-combustion supercritical CO2 (sCO2) are promised to reach blade material limit in near future foreseeing need of turbine blade cooling. Properties of sCO2 and the cycle parameters can make Reynolds number external to blade and external heat transfer coefficient to be significantly higher than those typically experience in regular gas turbines. This necessitates evaluation and rethinking of the internal cooling techniques to be adopted. The purpose of this paper is to investigate conjugate heat transfer effects within a first stage vane cascade of a sCO2 turbine. This study can help understand cooling requirements which include mass flow rate of leakage coolant sCO2 and geometry of cooling channels. Estimations can also be made if the cooling channels alone are enough for blade cooling or there is need for more cooling techniques such as film cooling, impingement cooling and trailing edge cooling. The conjugate heat transfer and aerodynamic analysis of a turbine cascade is carried out using STAR CCM+. The turbine inlet temperature of 1350K and 1775 K is considered for the study considering future potential needs. Thermo-physical properties of this mixture are given as input to the code in form of tables using REFPROP database. The blade material considered is Inconel 718.


2021 ◽  
Author(s):  
Hongyan Bu ◽  
Yufeng Yang ◽  
Liming Song ◽  
Jun Li

Abstract The gas turbine endwall is bearing extreme thermal loads with the rapid increase of turbine inlet temperature. Therefore, the effective cooling of turbine endwalls is of vital importance for the safe operation of turbines. In the design of endwall cooling layouts, numerical simulations based on conjugate heat transfer (CHT) are drawing more attention as the component temperature can be predicted directly. However, the computation cost of high-fidelity CHT analysis can be high and even prohibitive especially when there are many cases to evaluate such as in the design optimization of cooling layout. In this study, we established a multi-fidelity framework in which the data of low-fidelity CHT analysis was incorporated to help the building of a model that predicts the result of high-fidelity simulation. Based upon this framework, multi-fidelity design optimization of a validated numerical turbine endwall model was carried out. The high and low fidelity data were obtained from the computation of fine mesh and coarse mesh respectively. In the optimization, the positions of the film cooling holes were parameterized and controlled by a shape function. With the help of multi-fidelity modeling and sequentially evaluated designs, the cooling performance of the model endwall was improved efficiently.


Author(s):  
Zhongran Chi ◽  
Haiqing Liu ◽  
Shusheng Zang ◽  
Guangyun Jiao

This paper discusses the methodology of impingement cooling optimization of a gas turbine 2nd stage vane with 3D conjugate heat transfer (CHT) CFD analysis applied. The vane is installed with a novel impingement cooling structure in the leading cavity and a pin-fin array in the trailing edge. This study involves the optimization of the impingement cooling structure, including the location of the jet holes and the diameter of each hole. The generation of 3D model and CHT mesh was realized using an in-house code developed specifically for turbine cooling optimization. A constant pressure drop was assumed within the cooling system during optimization. To make the optimization computationally faster, a metamodel which can predict the detailed distribution of metal temperature on the vane surface was used in the second-level search together with a genetic algorithm. An optimal nonuniform impingement cooling structure in the leading cavity was automatically designed by the optimization process costing only dozens of CFD runs, which provided a more uniform temperature distribution on the vane surface and required no more coolant amount compared with the initial impingement cooling structure.


Author(s):  
Aneesh Sridhar Vadvadgi ◽  
Savas Yavuzkurt

The present study deals with the numerical modeling of the turbulent flow in a rotor-stator cavity with or without imposed through flow with heat transfer. The commercial finite volume based solver, ANSYS/FLUENT is used to numerically simulate the problem. A conjugate heat transfer approach is used. The study specifically deals with the calculation of the heat transfer coefficients and the temperatures at the disk surfaces. Results are compared with data where available. Conventional approaches which use boundary conditions such as constant wall temperature or constant heat flux in order to calculate the heat transfer coefficients which later are used to calculate disk temperatures can introduce significant errors in the results. The conjugate heat transfer approach can resolve this to a good extent. It includes the effect of variable surface temperature on heat transfer coefficients. Further it is easier to specify more realistic boundary conditions in a conjugate approach since solid and the flow heat transfer problems are solved simultaneously. However this approach incurs a higher computational cost. In this study, the configuration chosen is a simple rotor and stator system with a stationary and heated stator and a rotor. The aspect ratio is kept small (around 0.1). The flow and heat transfer characteristics are obtained for a rotational Reynolds number of around 106. The simulation is performed using the Reynolds Stress Model (RSM). The computational model is first validated against experimental data available in the literature. Studies have been carried out to calculate the disk temperatures using conventional non-conjugate and full conjugate approaches. It has been found that the difference between the disk temperatures for conjugate and non-conjugate computations is 5 K for the low temperature and 30 K for the high temperature boundary conditions. These represent differences of 1% and 2% from the respective stator surface temperatures. Even at low temperatures, the Nusselt numbers at the disk surface show a difference of 5% between the conjugate and non-conjugate computations, and far higher at higher temperatures.


Author(s):  
Debabrata Mukhopadhyay ◽  
Howard M. Brilliant ◽  
Xiaoqing Zheng

Shell deflection during shutdown, cool-down process is a phenomenon well known to the steam turbine community. The main reason for this phenomenon is slower cooling of the top half shell and a relative faster cooling of the bottom half shell. There are multiple reasons for such thermal behavior of the two half casings, including natural heat convection from the bottom half to the top half, asymmetrical distribution of mass, dissimilar behavior of thermal insulation over the top and the bottom halves, etc. Shell deflection poses considerable challenge to the clearance engineer in terms of configuring operating clearance which ensures rub free operations. Understanding the cool-down process for the rotor is also equally important as the allowable steam inlet temperature during the hot or warm restart will depend on prevailing local temperature of the rotor. This paper describes an exemplary physics-based cool-down prediction methodology capable of accurately capturing the rotor cool-down process. The methodology involves development of a full 3D rotor casing thermal model, integrated conjugate heat transfer FE model and validated with measured field data.


Author(s):  
Li Haibo ◽  
Chunwei Gu

Conjugate heat transfer is a key feature of modern gas turbine, as cooling technology is widely applied to improve the turbine inlet temperature for high efficiency. Impact of conjugate heat transfer on heat loads and thermodynamic efficiency is a key issue in gas turbine design. This paper presented a through flow calculation method to predict the impact of heat transfer on the design process of a convective cooled turbine. A cooling model was applied in the through flow calculations to predict the coolant requirements, as well as a one-dimensional mixing model to evaluate some key parameters such as pressure losses, deviation angles and velocity triangles because of the injection cooling air. Numerical simulations were performed for verification of the method and investigation on conjugate heat transfer within the blades. By comparing these two calculations, it is shown that the through flow calculation method is a useful tool for the blade design of convective cooled turbines because of its simplicity and flexibility.