Assessing the Ergonomic Benefits of a New Adjustable Forklift Backrest

Author(s):  
Pranav Madhav Kuber ◽  
Ehsan Rashedi

A new forklift backrest has been developed by incorporating adjustability concepts into the design to facilitate comfort to a wide range of users. We have conducted a comparative study between the new and original backrests to assess the effectiveness of design features. Using the phenomenon of restlessness, discomfort of the user was associated with the amount of body movement, where we have used a motion- capture system and a force platform to quantify the individuals’ movement for a wide range of body sizes. Meanwhile, subjective comfort and design feedback were collected using a questionnaire. Our results showed a reduction in the mean torso movement and the maximum center of pressure change of location by 300 and 6 mm, respectively, for the new design. Taking advantage of adjustability feature, the new backrest design exhibited enhanced comfort for longer durations and reduced magnitude of discomfort for a wide range of participants’ body sizes.

2012 ◽  
Vol 529 ◽  
pp. 290-294
Author(s):  
Yi Gao

This paper, by using German Simi Motion walking motion system, quantitatively describes the parameters and indicators of the human gait characteristics, tracks and captures the characteristics of body movement and motions of articulation points, compares the gait characteristics between different people, conclude significant differences between walking gait characteristics corresponding to different leg heights and knee bending angles through a large number of experiments, and finds out a description of stability and diversity under different human gait characteristics. This study extends the range and ideas of biological personal identification technology research, so as to provide a more scientific description of gait characteristics, so this study sets a basis for personal identification and establishing identity by using gait characteristics.


2019 ◽  
Vol 2019 ◽  
pp. 1-10 ◽  
Author(s):  
Birendra M. Dewan ◽  
C. Roger James ◽  
Neeraj A. Kumar ◽  
Steven F. Sawyer

Background. The Biodex Biosway® Balance System and SWAY Balance® Mobile smartphone application (SBMA) are portable instruments that assess balance function with force plate and accelerometer technology, respectively. The validity of these indirect clinical measures of postural sway merits investigation. Purpose. The purpose of this study was to investigate the concurrent validity of standing postural sway measurements by using the portable Biosway and SBMA systems with kinematic measurements of the whole body Center of Mass (COM) derived from a gold-standard reference, a motion capture system. Study Design. Cross-sectional; repeated measures. Methods. Forty healthy young adults (21 female, 19 male) participated in this study. Participants performed 10 standing balance tasks that included combinations of standing on one or two legs, with eyes open or closed, on a firm surface or foam surface and voluntary rhythmic sway. Postural sway was measured simultaneously from SBMA, Biosway, and the motion capture system. The linear relationships between the measurements were analyzed. Results. Significant correlations were found between Biosway and COM velocity for both progressively challenging single and double leg stances (τb = 0.3 to 0.5, p<0.01 to <0.0001). SBMA scores and COM velocity were significantly correlated only for single leg stances (τb = −0.5 to −0.6, p<0.0001). SBMA scores had near-maximal values with zero to near-zero variance in double leg stances, indicating a ceiling effect. Conclusion. The force plate-based Biodex Biosway is valid for assessing standing postural sway for a wide range of test conditions and challenges to standing balance, whereas an accelerometer-based SWAY Balance smartphone application is valid for assessing postural sway in progressively challenging single leg stance but is not sensitive enough to detect lower-magnitude postural sway changes in progressively challenging double leg stances.


Author(s):  
Jonathan Kenneth Sinclair ◽  
Lindsay Bottoms

AbstractRecent epidemiological analyses in fencing have shown that injuries and pain linked specifically to fencing training/competition were evident in 92.8% of fencers. Specifically the prevalence of Achilles tendon pathology has increased substantially in recent years, and males have been identified as being at greater risk of Achilles tendon injury compared to their female counterparts. This study aimed to examine gender differences in Achilles tendon loading during the fencing lunge.Achilles tendon load was obtained from eight male and eight female club level epee fencers using a 3D motion capture system and force platform information as they completed simulated lunges. Independent t-tests were performed on the data to determine whether differences existed.The results show that males were associated with significantly greater Achilles tendon loading rates in comparison to females.This suggests that male fencers may be at greater risk from Achilles tendon pathology as a function of fencing training/ competition.


2018 ◽  
Vol 7 (4) ◽  
pp. 13-21
Author(s):  
Todd Backes ◽  
Charlene Takacs

There are a wide range of options for individuals to choose from in order to engage in aerobic exercise; from outdoor running to computer controlled and self-propelled treadmills. Recently, self-propelled treadmills have increased in popularity and provide an alternative to a motorized treadmill. Twenty subjects (10 men, 10 women) ranging in age from 19-23 with a mean of 20.4 ± 0.8 SD were participants in this study. The subjects visited the laboratory on three occasions. The purpose of the first visit was to familiarize the subject with the self-propelled treadmill (Woodway Curve 3.0). The second visit, subjects were instructed to run on the self-propelled treadmill for 3km at a self-determined pace. Speed data were collected directly from the self-propelled treadmill. The third visit used speed data collected during the self-propelled treadmill run to create an identically paced 3km run for the subjects to perform on a motorized treadmill (COSMED T150). During both the second and third visit, oxygen consumption (VO2) and respiratory exchange ratio (R) data were collected with COSMED’s Quark cardiopulmonary exercise testing (CPET) metabolic mixing chamber system. The VO2 mean value for the self-propelled treadmill (44.90 ± 1.65 SE ml/kg/min) was significantly greater than the motorized treadmill (34.38 ± 1.39 SE ml/kg/min). The mean R value for the self-propelled treadmill (0.91 ± 0.01 SE) was significantly greater than the motorized treadmill (0.86 ± 0.01 SE). Our study demonstrated that a 3km run on a self-propelled treadmill does elicit a greater physiological response than a 3km run at on a standard motorized treadmill. Self-propelled treadmills provide a mode of exercise that offers increased training loads and should be considered as an alternative to motorized treadmills.


Author(s):  
V. Dodokhov ◽  
N. Pavlova ◽  
T. Rumyantseva ◽  
L. Kalashnikova

The article presents the genetic characteristic of the Chukchi reindeer breed. The object of the study was of the Chukchi reindeer. In recent years, the number of reindeer of the Chukchi breed has declined sharply. Reduced reindeer numbers could lead to biodiversity loss. The Chukchi breed of deer has good meat qualities, has high germination viability and is adapted in adverse tundra conditions of Yakutia. Herding of the Chukchi breed of deer in Yakutia are engaged only in the Nizhnekolymsky district. There are four generic communities and the largest of which is the agricultural production cooperative of nomadic tribal community «Turvaurgin», which was chosen to assess the genetic processes of breed using microsatellite markers: Rt6, BMS1788, Rt 30, Rt1, Rt9, FCB193, Rt7, BMS745, C 143, Rt24, OheQ, C217, C32, NVHRT16, T40, C276. It was found that microsatellite markers have a wide range of alleles and generally have a high informative value for identifying of genetic differences between animals and groups of animal. The number of identified alleles is one of the indicators of the genetic diversity of the population. The total number of detected alleles was 127. The Chukchi breed of deer is characterized by a high level of heterozygosity, and the random crossing system prevails over inbreeding in the population. On average, there were 7.9 alleles (Na) per locus, and the mean number of effective alleles (Ne) was 4.1. The index of fixation averaged 0.001. The polymorphism index (PIC) ranged from 0.217 to 0.946, with an average of 0.695.


2020 ◽  
Vol 16 (3) ◽  
pp. 241-247
Author(s):  
Atifete Ramosaj-Morina ◽  
Alije Keka-Sylaj ◽  
Arbana Baloku Zejnullahu ◽  
Lidvana Spahiu ◽  
Virgjina Hasbahta ◽  
...  

Background: Celiac disease is an immune-mediated disorder characterized by variable clinical manifestations, specific antibodies, HLA-DQ2/DQ8 haplotypes, and enteropathy. Objectives: The aim of this study was to present the clinical spectrum and patterns of celiac disease in Kosovar Albanian children. Methods: A cross-sectional retrospective study was performed with Albanian children aged 0-18 years, treated for celiac disease in the Pediatric Clinic, University Clinical Center of Kosovo from 2005 to 2016. Results: During the study period, 63 children were treated for celiac disease. The mean age at diagnosis was 5.5 years (SD ± 3.31). The mean age at celiac disease onset was 3.3 years (SD ± 2.02), while the mean delay from the first symptoms indicative of celiac disease to diagnosis was 2.2 years (SD ± 2.09). More than 70% of the patients were diagnosed in the first 7 years of life, mainly presented with gastrointestinal symptoms, while primary school children and adolescents mostly showed atypical symptoms (p<0.001). The classical form of celiac disease occurred in 78% of the cases. Sixty (95%) patients carried HLA-DQ2.5, DQ2.2 and/or HLA-DQ8 heterodimers, and only three of them tested negative. Conclusions: Kosovo, as the majority of developing countries, is still facing the classical form of celiac disease as the dominant mode of presentation; as a result, most children with other forms of the celiac disease remain undiagnosed. : Physicians should be aware of the wide range of clinical presentations and utilize low testing thresholds in order to prevent potential long-term problems associated with untreated celiac disease.


1997 ◽  
Vol 180 ◽  
pp. 475-476
Author(s):  
M. G. Richer ◽  
G. Stasińska ◽  
M. L. McCall

We have obtained spectra of 28 planetary nebulae in the bulge of M31 using the MOS spectrograph at the Canada-France-Hawaii Telescope. Typically, we observed the [O II] λ3727 to He I λ5876 wavelength region at a resolution of approximately 1.6 å/pixel. For 19 of the 21 planetary nebulae whose [OIII]λ5007 luminosities are within 1 mag of the peak of the planetary nebula luminosity function, our oxygen abundances are based upon a measured [OIII]λ4363 intensity, so they are based upon a measured electron temperature. The oxygen abundances cover a wide range, 7.85 dex < 12 + log(O/H) < 9.09 dex, but the mean abundance is surprisingly low, 12 + log(O/H)–8.64 ± 0.32 dex, i.e., roughly half the solar value (Anders & Grevesse 1989). The distribution of oxygen abundances is shown in Figure 1, where the ordinate indicates the number of planetary nebulae with abundances within ±0.1 dex of any point on the x-axis. The dashed line indicates the mean abundance, and the dotted lines indicate the ±1 σ points. The shape of this abundance distribution seems to indicate that the bulge of M31 does not contain a large population of bright, oxygen-rich planetary nebulae. This is a surprising result, for various population synthesis studies (e.g., Bica et al. 1990) have found a mean stellar metallicity approximately 0.2 dex above solar. This 0.5 dex discrepancy leads one to question whether the mean stellar metallicity is as high as the population synthesis results indicate or if such metal-rich stars produce bright planetary nebulae at all. This could be a clue concerning the mechanism responsible for the variation in the number of bright planetary nebulae observed per unit luminosity in different galaxies (e.g., Hui et al. 1993).


2006 ◽  
Vol 99 (8) ◽  
pp. 08B312 ◽  
Author(s):  
S. Hashi ◽  
M. Toyoda ◽  
M. Ohya ◽  
Y. Okazaki ◽  
S. Yabukami ◽  
...  

Sensors ◽  
2021 ◽  
Vol 21 (11) ◽  
pp. 3771
Author(s):  
Alexey Kashevnik ◽  
Walaa Othman ◽  
Igor Ryabchikov ◽  
Nikolay Shilov

Meditation practice is mental health training. It helps people to reduce stress and suppress negative thoughts. In this paper, we propose a camera-based meditation evaluation system, that helps meditators to improve their performance. We rely on two main criteria to measure the focus: the breathing characteristics (respiratory rate, breathing rhythmicity and stability), and the body movement. We introduce a contactless sensor to measure the respiratory rate based on a smartphone camera by detecting the chest keypoint at each frame, using an optical flow based algorithm to calculate the displacement between frames, filtering and de-noising the chest movement signal, and calculating the number of real peaks in this signal. We also present an approach to detecting the movement of different body parts (head, thorax, shoulders, elbows, wrists, stomach and knees). We have collected a non-annotated dataset for meditation practice videos consists of ninety videos and the annotated dataset consists of eight videos. The non-annotated dataset was categorized into beginner and professional meditators and was used for the development of the algorithm and for tuning the parameters. The annotated dataset was used for evaluation and showed that human activity during meditation practice could be correctly estimated by the presented approach and that the mean absolute error for the respiratory rate is around 1.75 BPM, which can be considered tolerable for the meditation application.


Sign in / Sign up

Export Citation Format

Share Document