Virtual trabecular bone models and their mechanical response

Author(s):  
F E Donaldson ◽  
P Pankaj ◽  
A H Law ◽  
A H Simpson

The study of the mechanical behaviour of trabecular bone has extensively employed micro-level finite element (μFE) models generated from images of real bone samples. It is now recognized that the key determinants of the mechanical behaviour of bone are related to its micro-architecture. The key indices of micro-architecture, in turn, depend on factors such as age, anatomical site, sex, and degree of osteoporosis. In practice, it is difficult to acquire sufficient samples that encompass these variations. In this preliminary study, a method of generating virtual finite element (FE) samples of trabecular bone is considered. Virtual samples, calibrated to satisfy some of the key micro-architectural characteristics, are generated computationally. The apparent level elastic and post-elastic mechanical behaviour of the generated samples is examined: the elastic mechanical response of these samples is found to compare well with natural trabecular bone studies conducted by previous investigators; the post-elastic response of virtual samples shows that material non-linearities have a much greater effect in comparison with geometrical non-linearity for the bone densities considered. Similar behaviour has been reported by previous studies conducted on real trabecular bone. It is concluded that virtual modelling presents a potentially valuable tool in the study of the mechanical behaviour of trabecular bone and the role of its micro-architecture.

2014 ◽  
Vol 695 ◽  
pp. 588-591
Author(s):  
Khairul Salleh Basaruddin ◽  
Ruslizam Daud

This study aims to investigate the influence of trabecular bone in human mandible bone on the mechanical response under implant load. Three dimensional voxel finite element (FE) model of mandible bone was reconstructed from micro-computed tomography (CT) images that were captured from bone specimen. Two FE models were developed where the first consists of cortical bone, trabecular bone and implants, and trabecular bone part was excluded in the second model. A static analysis was conducted on both models using commercial software Voxelcon. The results suggest that trabecular bone contributed to the strength of human mandible bone and to the effectiveness of load distribution under implant load.


2020 ◽  
pp. 002199832097679
Author(s):  
V Cucumazzo ◽  
E Demirci ◽  
B Pourdeyhimi ◽  
VV Silberschmidt

Calendered nonwovens, formed by polymeric fibres, are three-phase heterogeneous materials, comprising a fibrous matrix, bond-areas and interface regions. As a result, two main factors of anisotropy can be identified. The first one is ascribable to a random fibrous microstructure, with the second one related to orientation of a bond pattern. This paper focuses on the first type of anisotropy in thin and thick nonwovens under uniaxial tensile loading. Individual and combined effects of anisotropy and strain rate were studied by conducting uniaxial tensile tests in various loading directions (0°, 30°, 45°, 60° and 90° with regard to the main fabric’s direction) and strain rate (0.01, 0.1 and 0.5 s−1). Fabrics exhibited an initial linear elastic response, followed by nonlinear strain hardening up to necking and final softening. The studied allowed assessment of the extent the effects of loading direction (anisotropy), planar density and strain rate on the mechanical response of the calendered fabrics. The evidence supported the conclusion that anisotropy is the most crucial factor, also delineating the balance between the fabric’s load-bearing capacity and extension level along various directions. The strain rate produced a marked effect on the fibre’s response, with increased stress at higher strain rate while this effect in the fabric was small. The results demonstrated the differences of the mechanical behaviour of fabrics from that of their constituent fibres.


2010 ◽  
Vol 638-642 ◽  
pp. 2761-2765 ◽  
Author(s):  
J.G.F. Wismans ◽  
J.A.W. van Dommelen ◽  
L.E. Govaert ◽  
H.E.H. Meijer

A hybrid numerical-experimental approach is used to characterize the macroscopic mechanical behaviour of polymer foams. The method is based on characterization of foams with X-ray Computed Tomography and conversion of the data to Finite Element (FE) models. Results of FE analyses revealed that plasticity has a large influence on the mechanical response of these structures.


Author(s):  
Hassan Gonabadi ◽  
Yao Chen ◽  
Arti Yadav ◽  
Steve Bull

AbstractAlthough the literature is abundant with the experimental methods to characterize mechanical behavior of parts made by fused filament fabrication 3D printing, less attention has been paid in using computational models to predict the mechanical properties of these parts. In the present paper, a numerical homogenization technique is developed to predict the effect of printing process parameters on the elastic response of 3D printed parts with cellular lattice structures. The development of finite element computational models of printed parts is based on a multi scale approach. Initially, at the micro scale level, the analysis of micro-mechanical models of a representative volume element is used to calculate the effective orthotropic properties. The finite element models include different infill densities and building/raster orientation maintaining the bonded region between the adjacent fibers and layers. The elastic constants obtained by this method are then used as an input for the creation of macro scale finite element models enabling the simulation of the mechanical response of printed samples subjected to the bending, shear, and tensile loads. Finally, the results obtained by the homogenization technique are validated against more realistic finite element explicit microstructural models and experimental measurements. The results show that, providing an accurate characterization of the properties to be fed into the macro scale model, the use of the homogenization technique is a reliable tool to predict the elastic response of 3D printed parts. The outlined approach provides faster iterative design of 3D printed parts, contributing to reducing the number of experimental replicates and fabrication costs.


2014 ◽  
Vol 136 (12) ◽  
Author(s):  
Mikko S. Venäläinen ◽  
Mika E. Mononen ◽  
Jukka S. Jurvelin ◽  
Juha Töyräs ◽  
Tuomas Virén ◽  
...  

Mechanical behavior of bone is determined by the structure and intrinsic, local material properties of the tissue. However, previously presented knee joint models for evaluation of stresses and strains in joints generally consider bones as rigid bodies or linearly elastic solid materials. The aim of this study was to estimate how different structural and mechanical properties of bone affect the mechanical response of articular cartilage within a knee joint. Based on a cadaver knee joint, a two-dimensional (2D) finite element (FE) model of a knee joint including bone, cartilage, and meniscus geometries was constructed. Six different computational models with varying properties for cortical, trabecular, and subchondral bone were created, while the biphasic fibril-reinforced properties of cartilage and menisci were kept unaltered. The simplest model included rigid bones, while the most complex model included specific mechanical properties for different bone structures and anatomically accurate trabecular structure. Models with different porosities of trabecular bone were also constructed. All models were exposed to axial loading of 1.9 times body weight within 0.2 s (mimicking typical maximum knee joint forces during gait) while free varus–valgus rotation was allowed and all other rotations and translations were fixed. As compared to results obtained with the rigid bone model, stresses, strains, and pore pressures observed in cartilage decreased depending on the implemented properties of trabecular bone. Greatest changes in these parameters (up to −51% in maximum principal stresses) were observed when the lowest modulus for trabecular bone (measured at the structural level) was used. By increasing the trabecular bone porosity, stresses and strains were reduced substantially in the lateral tibial cartilage, while they remained relatively constant in the medial tibial plateau. The present results highlight the importance of long bones, in particular, their mechanical properties and porosity, in altering and redistributing forces transmitted through the knee joint.


2016 ◽  
Vol 713 ◽  
pp. 212-215 ◽  
Author(s):  
Kateřina Štegnerová ◽  
Luboš Náhlík ◽  
Pavel Hutař ◽  
Pavel Pokorný ◽  
Zdeněk Majer

The contribution deals with the issue of mechanical response of the particulate ceramic composites used in microelectronic. Mechanical properties and behaviour of composites are highly influenced by residual stresses which are developed in material during cooling in manufacturing process due to the different coefficients of thermal expansions of individual constituents. The main aim of this paper is to estimate the elastic constants and strength of the selected particulate ceramic composites with considering the residual stresses. Three dimensional models and finite element method are used for numerical simulations. Results contribute to determination and better understanding of mechanical behaviour of the particulate ceramic composites.


Author(s):  
Er. Hardik Dhull

The finite element method is a numerical method that is used to find solution of mathematical and engineering problems. It basically deals with partial differential equations. It is very complex for civil engineers to study various structures by using analytical method,so they prefer finite element methods over the analytical methods. As it is an approximate solution, therefore several limitationsare associated in the applicationsin civil engineering due to misinterpretationof analyst. Hence, the main aim of the paper is to study the finite element method in details along with the benefits and limitations of using this method in analysis of building components like beams, frames, trusses, slabs etc.


Sign in / Sign up

Export Citation Format

Share Document