scholarly journals Effect of Grinding and Subsequent Various Surface Treatments on the Surface Roughness of Full Contour Monolithic Zirconia

2021 ◽  
Vol 10 (32) ◽  
pp. 2624-2628
Author(s):  
Surya Teja ◽  
Sanath Kumar Shetty ◽  
Mohammed Mohammed ◽  
Karkala Syed ◽  
Uma Mayoor ◽  
...  

BACKGROUND A smooth zirconia surface is necessary to protect the opposing natural dentition, to prevent plaque accumulation and to increase the survival rate of restoration by reducing the chances of failure by crack propagation. Surface roughness can be incorporated by routine dental procedures done in labs and clinics to adjust the restoration. It is unclear which surface treatment is most appropriate to achieve clinically acceptable zirconia surface. The purpose of this study was to evaluate the effect of grinding and subsequent various surface treatments on the surface roughness of full contour monolithic zirconia. METHODS In this invitro study 10 zirconia bars of final dimensions 20 x 4 x 2 mm & 40 zirconia bars of final dimensions 20 x 4 x 2.2 mm were milled and sintered. The zirconia bars with final dimensions 20 x 4 x 2mm were glazed and selected as samples for control group (Group C) (n = 10). Forty zirconia bars with dimensions of 20 x 4 x 2.2 mm were grounded using a standard straight cylindrical diamond point (105 – 125 µm) by placing them in a customized grinding apparatus till the dimensions became similar to that of control group i.e. 20 x 4 x 2 mm. After grinding and confirming the dimensions of each full contour monolithic zirconia bar using digital vernier caliper, zirconia bars were randomly allocated into 4 groups with 10 samples in each group (n = 10), namely (Group G: Grinding only, Group G+R: Grinding & Reheating, Group G+G: Grinding & Glazing, Group G+P: Grinding & Polishing) respectively. Surface roughness values were measured using a profilometer. Differences between groups were examined using one-way analysis of variance (ANOVA) (P ≤ 0.05) and Post hoc Tukey HSD test was done for multiple comparisons of surface roughness in between the groups using Statistical Package for Social Sciences (SPSS) software. RESULTS Group C showed the least surface roughness values. The maximum surface roughness values were seen in Group G. Surface roughness of Group G, Group G + H and Group G + G were statistically significant from Group C and Group G + P. There was no statistically significant difference in surface roughness values between Group C and Group G + P. CONCLUSIONS It can be concluded that polishing after grinding significantly reduced the surface roughness and re-established the surface smoothness of full-contour monolithic zirconia bars. KEY WORDS Surface Roughness, Zirconia, Monolithic, Full Contour, Profilometer

2020 ◽  
Vol 21 (2) ◽  
pp. 126-131
Author(s):  
Bhuvanachandra Pasupuleti ◽  
Vamshikrishna Gone ◽  
Ravali Baddam ◽  
Raj Kumar Venisetty ◽  
Om Prakash Prasad

Background: Clobazam (CLBZ) metabolized primarily by Cytochrome P-450 isoenzyme CYP3A4 than with CYP2C19, Whereas Levetiracetam (LEV) is metabolized by hydrolysis of the acetamide group. Few CYP enzymes are inhibited by Proton Pump Inhibitors (PPIs) Pantoprazole, Esomeprazole, and Rabeprazole in different extents that could affect drug concentrations in blood. The aim of the present study was to evaluate the effect of these PPIs on the plasma concentrations of LEV and CLBZ. Methods: Blood samples from 542 patients were included out of which 343 were male and 199 were female patients and were categorized as control and test. Plasma samples analyzed using an HPLC-UV method. Plasma concentrations were measured and compared to those treated and those not treated with PPIs. One way ANOVA and games Howell post hoc test used by SPSS 20 software. Results: CLBZ concentrations were significantly 10 folds higher in patients treated with Pantoprazole (P=0.000) and 07 folds higher in patients treated with Esmoprazole and Rabeprazole (P=0.00). Whereas plasma concentration of LEV control group has no statistical and significant difference when compared to pantoprazole (P=0.546) and with rabeprazole and esomeprazole was P=0.999. Conclusion: The effect of comedication with PPIs on the plasma concentration of clobazam is more pronounced for pantoprazole to a greater extent when compared to esomeprazole and rabeprazole. When pantoprazole is used in combination with clobazam, dose reduction of clobazam should be considered, or significance of PPIs is seen to avoid adverse effects.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Ádám László Nagy ◽  
Zsolt Tóth ◽  
Tamás Tarjányi ◽  
Nándor Tamás Práger ◽  
Zoltán Lajos Baráth

Abstract Background In this research the biomechanical properties of a bone model was examined. Porcine ribs are used as experimental model. The objective of this research was to investigate and compare the biomechanical properties of the bone model before and after implant placement. Methods The bone samples were divided in three groups, Group 1 where ALL-ON-FOUR protocol was used during pre-drilling and placing the implants, Group 2 where ALL-ON-FOUR protocol was used during pre-drilling, and implants were not placed, and Group 3 consisting of intact bones served as a control group. Static and dynamic loading was applied for examining the model samples. Kruskal–Wallis statistical test and as a post-hoc test Mann–Whitney U test was performed to analyze experimental results. Results According to the results of the static loading, there was no significant difference between the implanted and original ribs, however, the toughness values of the bones decreased largely on account of predrilling the bones. The analysis of dynamic fatigue measurements by Kruskal–Wallis test showed significant differences between the intact and predrilled bones. Conclusion The pre-drilled bone was much weaker in both static and dynamic tests than the natural or implanted specimens. According to the results of the dynamic tests and after a certain loading cycle the implanted samples behaved the same way as the control samples, which suggests that implantation have stabilized the skeletal bone structure.


Author(s):  
Samed Satir ◽  
Muhammed Hilmi Buyukcavus ◽  
Kaan Orhan

The purpose of our study is to determine whether bucco-palatal/lingual (BPL) root dilacerations (RD), especially in single root teeth, can be determined using the ImageJ program through only one periapical radiography. Extracted teeth without any RD ( n = 8) were determined as the control group (Group 1) and with RD in apical 1/3 part at least 20° with the longitudinal axis in the BPL direction ( n = 8) as the study group (Group 2). With the help of a simple holder system prepared, digital periapical radiographs of all teeth were taken in an anteroposterior position. Histogram analysis of all periapical radiographs was performed using the spectrum feature of ImageJ software. It was aimed to make a dilaceration analysis by comparing the groups using mean, standard deviation, minimum, maximum, and bin width values. As a result of the Mann-Whitney U test, all mean and maximum values showed a statistically significant difference between the study and control groups ( p < 0.05). This pilot study revealed that the ImageJ software can be used to diagnose BPL dilaceration in the apical 1/3 part of the root. It is important for dentists and patients that it can contribute to limiting the radiation dose to which patients will be exposed.


2021 ◽  
Author(s):  
CA Jurado ◽  
A Tsujimoto ◽  
H Watanabe ◽  
NG Fischer ◽  
JA Hasslen ◽  
...  

SUMMARY Objective: The purpose of this study was to evaluate the effectiveness of five different polishing systems on a computer-aided design and computer-aided manufacturing (CAD/CAM) polymer-infiltrated ceramic-network restoration with nanoscale assessment using atomic force microscopy (AFM) and visual assessment performed by dental school senior students and faculty members. Method: Forty-eight full coverage crowns were milled out of polymer-infiltrated ceramic-network CAD/CAM blocks (Vita Enamic) for polishing with one company proprietary, two ceramic and two composite polishing systems. The prepared crowns were divided into six groups: (1) no polishing (control); (2) polishing with Vita Enamic Polishing Kit (VEna); (3) polishing with Shofu Porcelain Laminate Polishing Kit (SCer); (4) polishing with Brasseler Dialite Feather lite All- Ceramic Adjusting & Polishing System (BCer); (5) polishing with Shofu Composite Polishing Kit (SCom); and (6) polishing with Brasseler Composite Polishing Kit (BCom). The polished crown surface topography was observed, and surface roughness and area were measured with AFM. In addition, polished crowns were visually assessed by 15 senior dental students and 15 dental school faculty members. Results: All polishing treatments significantly reduced the surface roughness and area of the crown compared with the control. SCom and BCom showed significantly higher surface area than VEna, and the SCer and BCer groups were intermediate, showing no significant difference from either VEna or SCom and BCom. There were no significant differences in surface roughness between any of the systems. Dental students and faculty members classified the groups polished with VEna, SCer, and BCer groups as clinically acceptable, and they selected BCer group as the best polished restorations and the control group as the least polished restorations. Conclusions: Ceramic and composite polishing systems produced similar polishing results as that observed using a company proprietary polishing system. However, effectiveness for polishing using a company proprietary and ceramic polishing system tends to be higher than composite polishing systems.


2021 ◽  
Vol 17 (1) ◽  
pp. 22-26
Author(s):  
Kadek Ayu Wirayuni ◽  
◽  
I Made Hendri Dwi Saputra ◽  

Introduction: The denture base is the part of the removable denture that is supported by good adaptation to the underlying oral tissue. Most of the denture bases are made of acrylic or polymethyl methacrylate resin, better known as PMMA. However, the acrylic resin also has disadvantages such as easily broken and absorbs liquids both water and chemicals. The chemical absorption like alcohol, ethanol, and some drinks that contain acidic materials will chemically be induced with acrylic resin and settle in the pores of the acrylic resin. The chemical damage or defect creates roughness on the surface of the acrylic resin which can cause cracking or crazing and a decrease in surface strength and hardness. Materials and Methods: The method used in this research was a laboratory experimental design with a post-test-only control group using 12 samples consisting of 2 different types of samples by measuring the surface roughness of the acrylic resin after immersing the sample with a predetermined time. Results and Discussions: One-way ANOVA test results showed a significant difference in surface roughness after the samples immersion with a value of p = 0.006 (p <0.05). Conclusions: Based on this research, can be concluded that there is an increase in the surface roughness of the heated polymerized acrylic resin for 3 hours and 4 hours of immersion. The longer the heated polymerized acrylic resin is soaked in arak hence the level of surface roughness increases.


2015 ◽  
Vol 26 (1) ◽  
pp. 50-55 ◽  
Author(s):  
Mansour Rismanchian ◽  
Amin Davoudi ◽  
Elham Shadmehr

Connecting prostheses to the implant abutments has become a concern and achieving a satisfactory retention has been focused in cement-retention prostheses recently. Sandblasting is a method to make a roughened surface for providing more retention. The aim of this study was to compare effects of nano and micro airborne abrasive particles (ABAP) in roughening surface of implant abutments and further retention of cemented copings. Thirty Xive abutments and analogues (4.5 D GH1) were mounted vertically in self-cured acrylic blocks. Full metal Ni-Cr copings with a loop on the top were fabricated with appropriate marginal adaptation for each abutment. All samples were divided into 3 groups: first group (MPS) was sandblasted with 50 µm Al2O3 micro ABAP, second group (NSP) was sandblasted with 80 nm Al2O3 nano ABAP, and the third group (C) was assumed as control. The samples were cemented with provisional cement (Temp Bond) and tensile bond strength of cemented copings was evaluated by a universal testing machine after thermic cycling. The t test for independent samples was used for statistical analysis by SPSS software (version 15) at the significant level of 0.05. Final result showed significant difference among all groups (p<0.001) and MPS manifested the highest mean retention (207.88±45.61 N) with significant difference among other groups (p<0.001). The control group showed the lowest bond strength as predicted (48.95±10.44 N). Using nano or micro ABAP is an efficient way for increasing bond strengths significantly, but it seems that micro ABAP was more effective.


2018 ◽  
Vol 47 ◽  
pp. 07006
Author(s):  
Saryono Saryono ◽  
Hesti Devinta ◽  
Abdul Haris Budi Widodo ◽  
Arif Imam Hidayat

Contaminated water often affects the occurrence of periodontitis in the coastal area. The diabetic hypercholesterolemia-induced periodontitis in Indonesia is very high. The use of coenzyme Q10 to treat this disease has never been investigated yet. Therefore, this study aimedto analyze the effect of coenzyme Q10 on the lipid profile of diabetic hypercholesterolemia-induced periodontitis.Twenty four rats were randomized into 6 groups (G1-G6). The groups (G1-G3) are healthy, negative and positive control group respectively. The treatment groups (G4-G6) are diabetic hypercholesterolemia-induced rats given coenzyme q10 dose of 13,5; 27 and 54 mg/kg respectively. Rats were induced by periodontitis, hypercholesterolemia and diabetes mellitus. Coenzyme Q10 was administered orally using 2 mL gastric tube once a day for 14 days. Lipid profile including triglycerides, HDL, and atherogenic index (IA) was measured enzymatically by the CHOD-PAP method. Data were analyzed by one-way ANOVA test and followed by the Least Significant Difference (LSD) post hoc test.Coenzyme Q10 with a dose of 54 mg/kgis effective in lowering triglyceride, and atherogenic index and increasing HDL level in diabetic hyperlipidemia-induced periodontitis rats model. This research supports the potential effects of coenzyme Q10 supplementation to improve lipid profile in diabetic hypercholesterolemia-induced periodontitis in the coastal area.


2015 ◽  
Vol 26 (5) ◽  
pp. 478-483 ◽  
Author(s):  
Tânia Mara da Silva ◽  
Ana Carolina Rodrigues Danzi Salvia ◽  
Rodrigo Furtado de Carvalho ◽  
Eduardo Galera da Silva ◽  
Clóvis Pagani

Abstract: The aim of this study was to evaluate the effect of different polishing protocols on surface roughness and morphology of lithium disilicate ceramics (IPS e.max CAD). Fifty ceramic bars (2.0x3.0x2.5 mm) were produced and randomly divided into five groups (n=10), according to surface treatments: C: Control; Cer: Ceramaster (60 s); CW: cloth wheel with large-grit diamond (30 s) + cloth wheel with fine-grit diamond paste (30 s); E: grey Exa-Cerapol (20 s) + pink Exa-Cerapol (20 s) + Cerapol Super (20 s); F: Felt wheel with large-grit diamond paste (30 s) + Felt wheel with fine-grit diamond paste (30 s). The samples were evaluated quantitatively for surface roughness (Ra) and qualitatively by SEM, at different moments: initial (prior to roughening), after roughening and after polishing procedures. Ra means were submitted to two-way ANOVA and Tukey test (p<0.05). After the different polishing protocols, no statistically significant differences were observed between the Cer and E groups (p=0.6347), E and CW groups (p=0.1366), and CW and FW groups (p=0.5433). Comparing different stages in the same group, it was possible to observe that CW (p<0.0001) and FW groups (p<0.0001) showed significant differences. SEM analysis revealed that both Cer and E groups exhibited a surface morphological pattern similar to that of control group. All polishing systems were effective in reducing the surface roughness of the studied ceramic type.


2019 ◽  
Vol 21 (4) ◽  
pp. 194-199
Author(s):  
Mahdi Ghafari ◽  
Ebrahim Banitalebi ◽  
Mohamad Faramarzi

Background and aims: Intermuscular lipolysis disorder plays an important role in insulin resistance and diabetes mellitus and perilipin PLIN5 and PLIN3 are the key proteins in regulating muscle cellular lipolysis. Therefore, the purpose of this study was to examine the relationship between the expression of PLIN3 and PLIN5 protein following endurance training in streptozotocin (STZ) rats. Methods: A number of 24 male Wistar rats were randomly divided into low endurance training group (n = 8), high-intensity training group (n = 8), and control group (n = 8). Diabetes was induced in every rat by STZ injection. Three days after injection, the blood samples were taken from the cut tip of the tails of the mice and animals with blood glucose greater than 300 mg/dL were considered diabetic. The training program included eight weeks of aerobic training at different intensities. Training in high- and low-intensity groups included 22-25 and 5-8 m/min of training. Finally, one-way analysis of variance (ANOVA) and correlation was used to determine the significance of the differences between variables, followed by utilizing Tukey’s post-hoc test for significance. Results: The comparison between the groups by ANOVA showed significant differences in PLIN3 (P=0.0006) and PLIN5 (P=0.012). The results of Tukey post hoc test also demonstrated a statistical difference between the mean values of diabetic control group and high-intensity endurance group regarding PLIN3 (P=0.01) and PLIN5 (P=0.009), but no significant increase was observed in the lowintensity exercise group as compared to the control group (PLIN3, P=0.067 & PLIN5, P=0.44). As regards insulin resistance, there was a significant difference among the three groups (P=0.0001). Eventually, the result of the correlation between PLIN3 and PLIN5 showed similar enhancement by increasing the intensity (P=0.0026). Conclusion: According to research results, high-intensity endurance training increased the expression of PLIN3 and PLIN5 in diabetic specimens and PLIN3 and PLIN5 followed a similar increase pattern in high-intensity training


2016 ◽  
Vol 17 (11) ◽  
pp. 920-925 ◽  
Author(s):  
Bandar MA Al-Makramani ◽  
Fuad A Al-Sanabani ◽  
Abdul AA Razak ◽  
Mohamed I Abu-Hassan ◽  
Ibrahim Z AL-Shami ◽  
...  

ABSTRACT Aim The aim of this study was to evaluate the effect of surface treatments on shear bond strength (SBS) of Turkom-Cera (Turkom-Ceramic (M) Sdn. Bhd., Puchong, Malaysia) all-ceramic material cemented with resin cement Panavia-F (Kuraray Medical Inc., Okayama, Japan). Materials and methods Forty Turkom-Cera ceramic disks (10 mm × 3 mm) were prepared and randomly divided into four groups. The disks were wet ground to 1000-grit and subjected to four surface treatments: (1) No treatment (Control), (2) sandblasting, (3) silane application, and (4) sandblasting + silane. The four groups of 10 specimens each were bonded with Panavia-F resin cement according to manufacturer's recommendations. The SBS was determined using the universal testing machine (Instron) at 0.5 mm/min crosshead speed. Failure modes were recorded and a qualitative micromorphologic examination of different surface treatments was performed. The data were analyzed using the one-way analysis of variance (ANOVA) and Tukey honestly significant difference (HSD) tests. Results The SBS of the control, sandblasting, silane, and sandblasting + silane groups were: 10.8 ± 1.5, 16.4 ± 3.4, 16.2 ± 2.5, and 19.1 ± 2.4 MPa respectively. According to the Tukey HSD test, only the mean SBS of the control group was significantly different from the other three groups. There was no significant difference between sandblasting, silane, and sandblasting + silane groups. Conclusion In this study, the three surface treatments used improved the bond strength of resin cement to Turkom-Cera disks. Clinical significance The surface treatments used in this study appeared to be suitable methods for the cementation of glass infiltrated all-ceramic restorations. How to cite this article Razak AAA, Abu-Hassan MI, AL-Makramani BMA, AL-Sanabani FA, AL-Shami IZ, Almansour HM. Effect of Surface Treatments on the Bond Strength to Turkom-Cera All-Ceramic Material. J Contemp Dent Pract 2016;17(11):920-925.


Sign in / Sign up

Export Citation Format

Share Document