PIV Study of Flow in an Aerated Tank with a Hollow Blade Turbine

Author(s):  
Xuan Geng ◽  
Zhengming Gao ◽  
Yuyun Bao

Liquid phase hydrodynamics in an aerated tank (ID = 0.19 m) stirred by a half elliptical blade disk turbine (HEDT) have been investigated using particle image velocimetry (PIV) under both aerated and unaerated conditions. The effect of the gas flow rate on the aerated mean velocity of the liquid phase, turbulent kinetic energy and turbulent kinetic energy dissipation are discussed, and their comparisons with those under unaerated conditions are also carried out. Under aerated conditions, the presence of gas does not remarkably change the velocity pattern of the liquid phase. When the direction of the liquid flow is the same as the buoyancy, the liquid is accelerated up to 10.4% by bubbles at position of z/T=0.8 and r/T=0.45; while the liquid flow reversely, the liquid is decelerated about 37.5% under the gas flow rate of 0.2 vvm at the position of z/T=0.25 and r/T=0.45. The turbulent kinetic energy in the bulk flow increases after introducing gas phase, and the average turbulent kinetic energy of the upper, middle and lower regions at 0.2 vvm are increased by 37.3%, 37.8% and 142.7%, respectively. Large-eddy PIV approach is carried out to estimate the distribution of the turbulence kinetic energy dissipation. The result shows that the distribution of the turbulent kinetic energy dissipation is similar as those of turbulent kinetic energy.

Metals ◽  
2021 ◽  
Vol 11 (12) ◽  
pp. 1943
Author(s):  
Jian-Qiu Liu ◽  
Jian Yang ◽  
Chao Ma ◽  
Yi Guo ◽  
Wen-Yuan He ◽  
...  

In this paper, the effects of the width of the mold on the surface velocity, flow field pattern, turbulent kinetic energy distribution, and surface-level fluctuation in the mold were studied with measurement of the flow velocity near the surface of the mold at high temperature with the rod deflection method and numerical calculation with the standard k-ε model coupled with the discrete-phase model (DPM) model for automobile exposed panel production. Under the conditions of low fixed steel throughput of 2.2 ton/min, a nozzle immersion depth of 140 mm, and an argon gas flow rate of 4 L/min, as the width of the mold increases from 880 mm to 1050 mm and 1300 mm, the flow velocity near the surface of the mold decreases. The flow direction changes from the positive velocity with the mold widths of 880 mm and 1050 mm to the unstable velocity with the mold width of 1300 mm. The calculated results are in good agreement with the measured results. The turbulent kinetic energy near the submerged entry nozzle (SEN) gradually increases, and the risk of slag entrainment increases. Under the conditions of high fixed steel throughput of 3.5 ton/min, the SEN immersion depth of 160 mm, and the argon gas flow rate of 10 L/min, as the width of the mold increases from 1600 mm to 1800 mm and 2000 mm, the velocity near the mold surface decreases. The flow velocity at 1/4 of the surface of the mold is positive with the mold width of 1600 mm, while the velocities are negative with the widths of 1800 mm and 2000 mm. The calculated results are basically consistent with the measured results. The high turbulent kinetic energy area near the nozzle expands to a narrow wall, and the risk of slag entrainment is significantly increased. In both cases of low and high fixed steel throughput, the change rules of the flow field in the mold with the width are basically the same. The argon gas flow rate and the immersion depth of SEN should be adjusted reasonably to optimize the flow field in the mold with different widths under the same fixed steel throughput in the practical production.


Konversi ◽  
2019 ◽  
Vol 7 (1) ◽  
pp. 6
Author(s):  
Erlinda Ningsih ◽  
Abas Sato ◽  
Mochammad Alfan Nafiuddin ◽  
Wisnu Setyo Putranto

Abstract- One of the most widely used processes for CO2 gas removal is Absorption. Carbon dioxide is the result of the fuel combustion process which of the hazardous gases. The aim of this research is to determine the total mass transfer coefficient and analyze the effect of the absorbent flow rate of the absorbent solution with the promoter and the gas flow rate to the total mass transfer coefficient value. The variables consisted of liquid flow rate: 1, 2, 3, 4, 5 liter/min, gas flow rate: 15, 25, 30, 40, 50 liter/min and MSG concentration: 0%, 1%, 3% and 5% by weight. The solution of Pottasium Carbonate as absorbent with MSG promoter is flowed through top column and CO2 gas flowed from bottom packed column. Liquids were analyzed by titration and the gas output was analyzed by GC. From this research, it is found that the flow rate of gas and the liquid flow rate is directly proportional to the value of KGa. The liquid flow rate variable 5 liters / minute, gas flow rate 15 l / min obtained value of KGa 11,1102 at concentration of MSG 5%. Keywords:  Absorption, CO2,  K2CO3, MSG. 


1994 ◽  
Vol 29 (10-11) ◽  
pp. 231-241 ◽  
Author(s):  
H. T. Chang ◽  
B. E. Rittmann

This paper presents a unified model that inter-relates gas flow rate, liquid flow rate, and hold-ups of each of the liquid, gas, and solid phases in three-phase, fluidized-bed biofilm (TPFBB) process. It describes how carrier properties, biofilm properties, and gas and liquid flow velocities control the system dynamics, which ultimately will affect the density, thickness, and distribution of the biofilm. The paper describes the development of the mathematical model to correlate the effects of gas flow rate, liquid flow rate, solid concentration, and biofilm thickness and density. This knowledge is critically needed in light of the use of TPFBB processes in treating industrial wastewater, which often has high substrate concentration. For example, the proper design of the TPFBB process requires mathematical description of the cause-effect relationship between biofilm growth and fluidization.


Metals ◽  
2019 ◽  
Vol 9 (5) ◽  
pp. 555 ◽  
Author(s):  
Luis E. Jardón-Pérez ◽  
Daniel R. González-Morales ◽  
Gerardo Trápaga ◽  
Carlos González-Rivera ◽  
Marco A. Ramírez-Argáez

In this work, the effects of equal (50%/50%) or differentiated (75%/25%) gas flow ratio, gas flow rate, and slag thickness on mixing time and open eye area were studied in a physical model of a gas stirred ladle with dual plugs separated by an angle of 180°. The effect of the variables under study was determined using a two-level factorial design. Particle image velocimetry (PIV) was used to establish, through the analysis of the flow patterns and turbulence kinetic energy contours, the effect of the studied variables on the hydrodynamics of the system. Results revealed that differentiated injection ratio significantly changes the flow structure and greatly influences the behavior of the system regarding mixing time and open eye area. The Pareto front of the optimized results on both mixing time and open eye area was obtained through a multi-objective optimization using a genetic algorithm (NSGA-II). The results are conclusive in that the ladle must be operated using differentiated flow ratio for optimal performance.


SPE Journal ◽  
2006 ◽  
Vol 11 (02) ◽  
pp. 199-205 ◽  
Author(s):  
David I. Atkinson ◽  
Oyvind Reksten ◽  
Gerald Smith ◽  
Helge Moe

Summary Dedicated wet-gas flowmeters are now commercially available for the measurement of gas and liquid flow rates and offer a more compact measurement solution than does the traditional separator approach. The interpretation models of traditional multiphase flowmeters emphasize the liquid rate measurements and have been used to well test and meter mostly liquid-rich flow streams. These models were not developed for the measurement of gas flow rates, particularly those of wet gas. A new interpretation is described that allows a traditional multiphase flowmeter to operate in a dual mode either as a multiphase meter or as a wet-gas meter in 90 to 100% gas. The new interpretation model was developed for a commercially available multiphase flowmeter consisting of a venturi and a dual-energy composition meter. This combination results in excellent predictions of the gas flow rate; the liquid rate prediction is made with acceptable accuracy and no additional measurements. The wet gas and low-liquid-volume-fraction interpretation model is described together with the multiphase flowmeter. Examples of applying this model to data collected on flow loops are presented, with comparison to reference flow rates. The data from the Sintef and NEL flow loops show an error (including the reference meter error) in the gas flow rate, better than ± 2% reading (95% confidence interval), at line conditions; the absolute error (including the reference meter error) in the measured total liquid flow rate at line conditions was better than ± 2 m3/h (< ± 300 B/D: 95% confidence interval). This new interpretation model offers a significant advance in the metering of wet-gas multiphase flows and yields the possibility of high accuracies to meet the needs of gas-well testing and production allocation applications without the use of separators. Introduction There has been considerable focus in recent years on the development of new flow-measurement techniques for application to surface well testing and flow-measurement allocation in multiphase conditions without separating the phases. This has resulted in new technology from the industry for both gas and oil production. Today, there are wet-gas flowmeters, dedicated to the metering of wet-gas flows, and multiphase meters, for the metering of multiphase liquid flows. The common approach to wet-gas measurement relates gas and liquid flows to a "pseudo-gas flow rate" calculated from the standard single-phase equations. This addresses the need for gas measurement in the presence of liquids and can be applied to a limit of liquid flow [or gas volume fraction, (GVF)], though the accuracy of this approach decreases with decreasing GVF. The accurate determination of liquid rates by wet-gas meters is restricted in range. The application and performance of multiphase meters has been well documented through technical papers and industry forums, and after several years of development is maturing (Scheers 2004). Some multiphase measurement techniques can perform better, and the meters provide a more compact solution, than the traditional separation approach. It is not surprising that the use of multiphase flowmeters has grown significantly, the worldwide number doubling in little over a 2-year period (Mehdizadeh et al. 2002). Multiphase-flowmeter interpretation emphasizes the liquid rate measurement, and the application of multiphase flowmeters has been predominantly for liquid-rich flow stream allocation and well testing.


1989 ◽  
Vol 8 (2) ◽  
pp. 63-68
Author(s):  
A. J. Rautenbach ◽  
G. Kornelius

Spray columns are widely used in industry as a gas-liquid contacting apparatus because of the advantages of a high transfer area per unit volume and the tow gas side resistance. For a large number of systems, mass transfer parameters are not available and an experimental determination for the system benzene/wash oil was therefore carried out. The experimental technique and design are described. The variation in mass transfer coefficient as function of gas flow rate, liquid flow rate and column height agrees with those published elsewhere.


Nowadays, CO2 as the product of fossil fuel combustions, is polluting the air and the human environment, and it causes global warming. To reduce the negative effect of CO2 presence, it should be removed from the air by capturing methods. Hollow fiber membrane contactor (HFMC) system is one of the most efficient method for CO2 capturing than the other feasible capturing methods. In the present paper an HFMC absorbing system has been simulated using COMSOL Multiphysics software and the effect of flow rates of gas and liquid on the amount of CO2 removal has been studied. Aqueous solution of Mono-ethanolamine (MEA) is entered as the absorbent liquid in the tubes, and CO2 is removed from the shell side by the diffusion phenomena by participating in the chemical reaction with MEA. The results show that the higher liquid flow rate the higher %CO2 removal from the inserted gas. Against this result, the percentage of CO2 removal decreases with increasing the gas flow rate as expected. Higher gas flow rate leads the gas velocity to higher values and less possibility of absorbing by the diffusion method. The rate of the CO2 removal variation with liquid flow rate is higher than the CO2 removal variation whit the gas flow rate.


Author(s):  
Yaw Y. Afriyie ◽  
Ebenezer E. Essel ◽  
Eric W. Thacher ◽  
Mark F. Tachie

This paper presents results of an experimental research conducted to study roughness effects downstream of a forward facing step (FFS). A rough surface and a hydraulically smooth surface were used as a rough-FFS and a smooth-FFS, respectively. The upstream condition was kept smooth. Particle image velocimetry (PIV) technique was used for the velocity measurements. The Reynolds number based on the step height (h) and freestream velocity of the approach flow was kept constant at 8685. The results show that the mean reattachment length for the smooth-FFS (SM-SM) is 1.9h. Roughness reduced the peak values of the streamwise mean velocity, Reynolds shear stress and turbulent kinetic energy by 3%, 45% and 16.7% respectively in the recirculation region. In the early redevelopment region, roughness also reduced the peak values of turbulent kinetic energy and the Reynolds shear stress by 41% and 22% respectively.


2013 ◽  
Vol 864-867 ◽  
pp. 2139-2144 ◽  
Author(s):  
Yang Lin Li

In order to improve the efficiency of ozone mass transfer in liquid phase, the method enhanced by electric field was put forward. The effect on ozone mass transfer was investigated from voltage, electrode spacing and gas flow rate. The result showed that ozone concentration in water and the total mass transfer coefficient increased correspondingly with the increase of the voltage, and ozone concentration in water and the total mass transfer coefficient increased correspondingly with increase of the electrode spacing in the range from 1 to 3 cm, and ozone concentration in water increased correspondingly with increase of the gas flow rate, but the total mass transfer coefficient reduced correspondingly.


2016 ◽  
Vol 859 ◽  
pp. 153-157
Author(s):  
Pao Chi Chen ◽  
Sheng Zhong Lin

This work uses a continuous bubble-column scrubber for the absorption of CO2 with a 5M MEA solution under a constant pH environment to explore the effect of the pH of the solution and gas-flow rate (Qg) on the removal efficiency (E), absorption rate (RA), overall mass-transfer coefficient (KGa), liquid flow rate (QL), gas-liquid flow ratio (γ), and scrubbing factors (φ). From the outlet CO2 concentration with a two-film model, E, RA, KGa, QL, γ, and φ can be simultaneously determined at the steady state. Depending on the operating conditions, the results show that E (80-97%), RA(2.91x10-4-10.0x10-4mol/s-L), KGa (0.09-0.48 1/s), QL(8.74-230.8mL/min), γ (0.19-5.39), and φ (0.031-0.74 mol/mol-L) are found to be comparable with other solvents. In addition, RA, KGa, E, and QL have been used to correlate with pH and Qg, respectively, with the results further explained.


Sign in / Sign up

Export Citation Format

Share Document