scholarly journals Analysis of expansion within a pressure inflated section of an urethral stricture model

2021 ◽  
Vol 7 (2) ◽  
pp. 578-581
Author(s):  
Ashish Bhave ◽  
Knut Möller

Abstract The Urethra is a long tubular structure in the genitourinary tract and serves important functions. Researchers have experimented with some approaches to model the urethra and to analyse its biomechanical properties. However, experiments to model the in-vivo behaviour of urethra with strictures is not thoroughly explored. To analyse the in-vivo urethral properties and specifically for supporting treatment of strictures, a new inflatable sensor-actuator system is being developed. The capabilities of this sensor shall be evaluated in simulations which require appropriate modelling of the human male urethra with strictures. This forms a part of the identification procedure for a variety of urethra conditions and geometries, which in turn forms a basis for inverse modelling. As an initial simplified approach, an axisymmetric Finite Element model was generated that resembled the urethra incorporating a stricture region. An ideal actuator with sensor elements exerting a pressure on inner wall of this urethra was simulated. Three circumference measurement zones within the sensor height (top surface, centre and bottom surface) were implemented. The resulting pressure-extension (circumferential) responses were determined at these measurement zones. The sensor was placed at different lengths within this urethral tube and inflated and the pressure-extension responses were noted. It was found that depending on the position of the sensor-actuator, the extension of tissue can vary. The possible factors for this variation were the finite length of the actuator as well as the influence of tissue properties around the measurement zones. This is important information for the interpretation of sensor data to be gained by the current development. It was possible to generate datasets based on an ideal sensor model, that proved helpful in the evaluation of biomechanical tissue properties in healthy and stricture conditions. This indicates simulations are a versatile and prospective way to test new sensors prior to real experiments.

2008 ◽  
Vol 130 (2) ◽  
Author(s):  
Jacob Rosen ◽  
Jeffrey D. Brown ◽  
Smita De ◽  
Mika Sinanan ◽  
Blake Hannaford

Accurate knowledge of biomechanical characteristics of tissues is essential for developing realistic computer-based surgical simulators incorporating haptic feedback, as well as for the design of surgical robots and tools. As simulation technologies continue to be capable of modeling more complex behavior, an in vivo tissue property database is needed. Most past and current biomechanical research is focused on soft and hard anatomical structures that are subject to physiological loading, testing the organs in situ. Internal organs are different in that respect since they are not subject to extensive loads as part of their regular physiological function. However, during surgery, a different set of loading conditions are imposed on these organs as a result of the interaction with the surgical tools. Following previous research studying the kinematics and dynamics of tool/tissue interaction in real surgical procedures, the focus of the current study was to obtain the structural biomechanical properties (engineering stress-strain and stress relaxation) of seven abdominal organs, including bladder, gallbladder, large and small intestines, liver, spleen, and stomach, using a porcine animal model. The organs were tested in vivo, in situ, and ex corpus (the latter two conditions being postmortem) under cyclical and step strain compressions using a motorized endoscopic grasper and a universal-testing machine. The tissues were tested with the same loading conditions commonly applied by surgeons during minimally invasive surgical procedures. Phenomenological models were developed for the various organs, testing conditions, and experimental devices. A property database—unique to the literature—has been created that contains the average elastic and relaxation model parameters measured for these tissues in vivo and postmortem. The results quantitatively indicate the significant differences between tissue properties measured in vivo and postmortem. A quantitative understanding of how the unconditioned tissue properties and model parameters are influenced by time postmortem and loading condition has been obtained. The results provide the material property foundations for developing science-based haptic surgical simulators, as well as surgical tools for manual and robotic systems.


2021 ◽  
Author(s):  
Kyle W Christensen ◽  
Jonathan Turner ◽  
Kelly Coughenour ◽  
Yas Maghdouri-White ◽  
Anna A Bulysheva ◽  
...  

Musculoskeletal tissue injuries, including the damage and rupture of ligaments and tendons, and volumetric muscle loss (VML), are exceptionally commonplace and often lead to permanent disability and deformation. We developed an advanced biomanufacturing platform producing cellularized collagen microfiber implants to facilitate functional repair and regeneration of musculoskeletal soft tissues. This Assembled Cell-Decorated Collagen (AC-DC) bioprinting process rapidly and reproducibly forms 3D implants using clinically relevant cells and strong, microfluidic extruded collagen fibers. Quantitative analysis showed that the directionality and distribution of cells throughout AC-DC implants mimic the cellular properties of native musculoskeletal tissue. AC-DC bioprinted implants further approximate or exceed the strength and stiffness of human tendons and ligaments and exceeded the properties of commonplace collagen hydrogels by orders of magnitude. The regenerative potential of AC-DC implants was also assessed in vivo in a rodent VML model. A critically sized muscle injury in the hindlimb was created and repaired, and limb torque generation potential was measured over 12 weeks. Both acellular and cellular implants were found to promote functional recovery compared to the unrepaired group, with AC-DC implants containing therapeutic muscle progenitor cells promoting the highest degree of recovery. Histological analysis and automated image processing of explanted muscle cross-sections revealed increased total muscle fiber count, median muscle fiber size, and increased cellularization for injuries repaired with cellularized implants. These studies introduce the tremendous potential of an advanced bioprinting method for generating tissue analogs with near-native biological and biomechanical properties with the potential to repair numerous challenging musculoskeletal injuries.


2017 ◽  
Vol 139 (10) ◽  
Author(s):  
Kathryn M. Robison ◽  
Cassandra K. Conway ◽  
Laurephile Desrosiers ◽  
Leise R. Knoepp ◽  
Kristin S. Miller

Progress toward understanding the underlying mechanisms of pelvic organ prolapse (POP) is limited, in part, due to a lack of information on the biomechanical properties and microstructural composition of the vaginal wall. Compromised vaginal wall integrity is thought to contribute to pelvic floor disorders; however, normal structure–function relationships within the vaginal wall are not fully understood. In addition to the information produced from uniaxial testing, biaxial extension–inflation tests performed over a range of physiological values could provide additional insights into vaginal wall mechanical behavior (i.e., axial coupling and anisotropy), while preserving in vivo tissue geometry. Thus, we present experimental methods of assessing murine vaginal wall biaxial mechanical properties using extension–inflation protocols. Geometrically intact vaginal samples taken from 16 female C57BL/6 mice underwent pressure–diameter and force–length preconditioning and testing within a pressure-myograph device. A bilinear curve fit was applied to the local stress–stretch data to quantify the transition stress and stretch as well as the toe- and linear-region moduli. The murine vaginal wall demonstrated a nonlinear response resembling that of other soft tissues, and evaluation of bilinear curve fits suggests that the vagina exhibits pseudoelasticity, axial coupling, and anisotropy. The protocols developed herein permit quantification of biaxial tissue properties. These methods can be utilized in future studies in order to assess evolving structure–function relationships with respect to aging, the onset of prolapse, and response to potential clinical interventions.


Life ◽  
2021 ◽  
Vol 11 (6) ◽  
pp. 515
Author(s):  
Andrea Cugno ◽  
Alex Marki ◽  
Klaus Ley

Leukocytes, including neutrophils, which are propelled by blood flow, can roll on inflamed endothelium using transient bonds between selectins and their ligands, and integrins and their ligands. When such receptor–ligand bonds last long enough, the leukocyte microvilli become extended and eventually form thin, 20 m long tethers. Tether formation can be observed in blood vessels in vivo and in microfluidic flow chambers. Tethers can also be extracted using micropipette aspiration, biomembrane force probe, optical trap, or atomic force microscopy approaches. Here, we review the biomechanical properties of leukocyte tethers as gleaned from such measurements and discuss the advantages and disadvantages of each approach. We also review and discuss viscoelastic models that describe the dependence of tether formation on time, force, rate of loading, and cell activation. We close by emphasizing the need to combine experimental observations with quantitative models and computer simulations to understand how tether formation is affected by membrane tension, membrane reservoir, and interactions of the membrane with the cytoskeleton.


2021 ◽  
Vol 22 (2) ◽  
pp. 674
Author(s):  
Óscar Darío García-García ◽  
Marwa El Soury ◽  
David González-Quevedo ◽  
David Sánchez-Porras ◽  
Jesús Chato-Astrain ◽  
...  

Acellular nerve allografts (ANGs) represent a promising alternative in nerve repair. Our aim is to improve the structural and biomechanical properties of biocompatible Sondell (SD) and Roosens (RS) based ANGs using genipin (GP) as a crosslinker agent ex vivo. The impact of two concentrations of GP (0.10% and 0.25%) on Wistar rat sciatic nerve-derived ANGs was assessed at the histological, biomechanical, and biocompatibility levels. Histology confirmed the differences between SD and RS procedures, but not remarkable changes were induced by GP, which helped to preserve the nerve histological pattern. Tensile test revealed that GP enhanced the biomechanical properties of SD and RS ANGs, being the crosslinked RS ANGs more comparable to the native nerves used as control. The evaluation of the ANGs biocompatibility conducted with adipose-derived mesenchymal stem cells cultured within the ANGs confirmed a high degree of biocompatibility in all ANGs, especially in RS and RS-GP 0.10% ANGs. Finally, this study demonstrates that the use of GP could be an efficient alternative to improve the biomechanical properties of ANGs with a slight impact on the biocompatibility and histological pattern. For these reasons, we hypothesize that our novel crosslinked ANGs could be a suitable alternative for future in vivo preclinical studies.


Author(s):  
Zhong Li ◽  
Yikang Bi ◽  
Qi Wu ◽  
Chao Chen ◽  
Lu Zhou ◽  
...  

AbstractTo evaluate the performance of a composite scaffold of Wharton’s jelly (WJ) and chondroitin sulfate (CS) and the effect of the composite scaffold loaded with human umbilical cord mesenchymal stem cells (hUCMSCs) in repairing articular cartilage defects, two experiments were carried out. The in vitro experiments involved identification of the hUCMSCs, construction of the biomimetic composite scaffolds by the physical and chemical crosslinking of WJ and CS, and testing of the biomechanical properties of both the composite scaffold and the WJ scaffold. In the in vivo experiments, composite scaffolds loaded with hUCMSCs and WJ scaffolds loaded with hUCMSCs were applied to repair articular cartilage defects in the rat knee. Moreover, their repair effects were evaluated by the unaided eye, histological observations, and the immunogenicity of scaffolds and hUCMSCs. We found that in vitro, the Young’s modulus of the composite scaffold (WJ-CS) was higher than that of the WJ scaffold. In vivo, the composite scaffold loaded with hUCMSCs repaired rat cartilage defects better than did the WJ scaffold loaded with hUCMSCs. Both the scaffold and hUCMSCs showed low immunogenicity. These results demonstrate that the in vitro construction of a human-derived WJ-CS composite scaffold enhances the biomechanical properties of WJ and that the repair of knee cartilage defects in rats is better with the composite scaffold than with the single WJ scaffold if the scaffold is loaded with hUCMSCs.


2009 ◽  
Vol 79 (4) ◽  
pp. 703-714 ◽  
Author(s):  
Carmen Gonzales ◽  
Hitoshi Hotokezaka ◽  
Yoshinori Arai ◽  
Tadashi Ninomiya ◽  
Junya Tominaga ◽  
...  

Abstract Objective: To investigate the precise longitudinal change in the periodontal ligament (PDL) space width and three-dimensional tooth movement with continuous-force magnitudes in living rats. Materials and Methods: Using nickel-titanium closed-coil springs for 28 days, 10-, 25-, 50-, and 100-g mesial force was applied to the maxillary left first molars. Micro-CT was taken in the same rat at 0, 1, 2, 3, 10, 14, and 28 days. The width of the PDL was measured in the pressure and tension sides from 0 to 3 days. Angular and linear measurements were used to evaluate molar position at day 0, 10, 14, and 28. The finite element model (FEM) was constructed to evaluate the initial stress distribution, molar displacement, and center of rotation of the molar. Results: The initial evaluation of PDL width showed no statistical differences among different force magnitudes. Tooth movement was registered 1 hour after force application and gradually increased with time. From day 10, greater tooth movement was observed when 10 g of force was applied. The FEM showed that the center of rotation in the molar is located in the center of five roots at the apical third of the molar roots. Conclusion: The rat's molar movement mainly consists of mesial tipping, extrusion of distal roots, intrusion of mesial root, palatal inclination, and mesial rotation. Although the initial tooth movement after the application of different force magnitudes until day 3 was not remarkably different, 10 g of force produced more tooth movement compared with heavier forces at day 28.


Author(s):  
Kivilcim Buyukhatipoglu ◽  
Robert Chang ◽  
Wei Sun ◽  
Alisa Morss Clyne

Tissue engineering may require precise patterning of cells and bioactive components to recreate the complex, 3D architecture of native tissue. However, it is difficult to image and track cells and bioactive factors once they are incorporated into the tissue engineered construct. These bioactive factors and cells may also need to be moved during tissue growth in vitro or after implantation in vivo to achieve the desired tissue properties, or they may need to be removed entirely prior to implantation for biosafety concerns.


2013 ◽  
Vol 135 (10) ◽  
Author(s):  
Clare Y. L. Chao ◽  
Gabriel Y. F. Ng ◽  
Kwok-Kuen Cheung ◽  
Yong-Ping Zheng ◽  
Li-Ke Wang ◽  
...  

An evaluation of wound mechanics is crucial in reflecting the wound healing status. The present study examined the biomechanical properties of healing rat skin wounds in vivo and ex vivo. Thirty male Sprague-Dawley rats, each with a 6 mm full-thickness circular punch biopsied wound at both posterior hind limbs were used. The mechanical stiffness at both the central and margins of the wound was measured repeatedly in five rats over the same wound sites to monitor the longitudinal changes over time of before wounding, and on days 0, 3, 7, 10, 14, and 21 after wounding in vivo by using an optical coherence tomography-based air-jet indentation system. Five rats were euthanized at each time point, and the biomechanical properties of the wound tissues were assessed ex vivo using a tensiometer. At the central wound bed region, the stiffness measured by the air-jet system increased significantly from day 0 (17.2%), peaked at day 7 (208.3%), and then decreased progressively until day 21 (40.2%) as compared with baseline prewounding status. The biomechanical parameters of the skin wound samples measured by the tensiometer showed a marked reduction upon wounding, then increased with time (all p < 0.05). On day 21, the ultimate tensile strength of the skin wound tissue approached 50% of the normal skin; while the stiffness of tissue recovered at a faster rate, reaching 97% of its prewounded state. Our results suggested that it took less time for healing wound tissues to recover their stiffness than their maximal strength in rat skin. The stiffness of wound tissues measured by air-jet could be an indicator for monitoring wound healing and contraction.


Sign in / Sign up

Export Citation Format

Share Document