scholarly journals Field Demonstration of Heat Technology to Mitigate Heat Sinks for Drywood Termite (Blattodea: Kalotermitidae) Management

Author(s):  
Jia-Wei Tay ◽  
Devon James

With heat treatments to control drywood termites (Blattodea: Kalotermitidae), the presence of heat sinks causes heat to be distributed unevenly throughout the treatment areas. Drywood termites may move to galleries in heat sink areas to avoid exposure to lethal temperatures. Our studies were conducted in Crytotermes brevis-infested condominiums in Honolulu, Hawaii to reflect real-world condominium scenarios; either a standard heat treatment performed by a heat remediation company or an improved heat treatment was used. For improved treatments, heated air was directed into the toe-kick voids of C. brevis infested cabinets to reduce heat sink effects and increase the heat penetration into these difficult-to-heat areas. Eight thermistor sensors placed inside toe-kick voids, treatment zone, embedded inside cabinets’ sidewalls, and in a wooden cube recorded target temperatures of above 46 °C or 50 °C for 120 minutes. A pretreatment and follow-up inspections were performed at 6 months posttreatment to monitor termite inactivity using visual observations and by recording the numbers of spiked peaks on a microwave technology termite detection device (Termatrac). In improved treatment condominiums, significantly higher numbers of spiked peaks were recorded at pretreatment as compared to 6 months posttreatment. Efficacious heat treatment protocols using the improved methods are proposed.

Insects ◽  
2021 ◽  
Vol 12 (12) ◽  
pp. 1090
Author(s):  
Jia-Wei Tay ◽  
Devon James

With heat treatments to control drywood termites (Blattodea: Kalotermitidae), the presence of heat sinks causes heat to be distributed unevenly throughout the treatment areas. Drywood termites may move to galleries in heat sink areas to avoid exposure to lethal temperatures. Our studies were conducted in Crytotermes brevis-infested condominiums in Honolulu, Hawaii to reflect real-world condominium scenarios; either a standard heat treatment performed by a heat remediation company, or an improved heat treatment was used. For improved treatments, heated air was directed into the toe-kick voids of C. brevis infested cabinets to reduce heat sink effects and increase heat penetration into these difficult-to-heat areas. Eight thermistor sensors placed inside the toe-kick voids, treatment zone, embedded inside cabinets’ sidewalls, and in a wooden cube recorded target temperatures of above 46 °C or 50 °C for 120 min. Pre-treatment and follow-up inspections were performed at 6 months posttreatment to monitor termite inactivity using visual observations and by recording the numbers of spiked peaks on a microwave technology termite detection device (Termatrac). In improved treatment condominiums, significantly higher numbers of spiked peaks were recorded at pre-treatment as compared to 6 months posttreatment. Efficacious heat treatment protocols using the improved methods are proposed.


Author(s):  
Jia-Wei Tay ◽  
Devon James

With heat treatments to control drywood termites (Blattodea: Kalotermitidae), the presence of heat sinks, which have insulating properties, causes heat to be distributed unevenly throughout the treatment areas. Drywood termites may move to galleries in heat sink areas to avoid exposure to lethal temperatures. To mitigate heat sink effect, studies were conducted in Crytotermes brevis-infested homes in Honolulu, Hawaii to reflect real-world scenarios; either a standard heat treatment performed by a heat remediation company or improved heat treatment methods were used. For improved treatments, heated air was directed into the toe-kick voids of cabinets to reduce heat sink effects. Eight thermistor sensors were placed inside toe-kick voids, in the treatment zone, embedded inside cabinets or the sidewall, or in a wooden cube to monitor internal and ambient temperatures to ensure sufficiently high heat reached all areas. Target temperatures above 46 °C or 50 °C were recorded in all areas for 120 minutes. A pretreatment inspection was conducted, and follow-up inspections were performed at 6 months posttreatment to confirm termite inactivity using visual observations and a Termatrac device. In improved treatment homes, no termite activity was found after treatment. Efficacious heat treatment protocols for structures using the improved method are proposed.


Author(s):  
Nico Setiawan Effendi ◽  
Kyoung Joon Kim

A computational study is conducted to explore thermal performances of natural convection hybrid fin heat sinks (HF HSs). The proposed HF HSs are a hollow hybrid fin heat sink (HHF HS) and a solid hybrid fin heat sink (SHF HS). Parametric effects such as a fin spacing, an internal channel diameter, a heat dissipation on the performance of HF HSs are investigated by CFD analysis. Study results show that the thermal resistance of the HS increases while the mass-multiplied thermal resistance of the HS decreases associated with the increase of the channel diameter. The results also shows the thermal resistance of the SHF HS is 13% smaller, and the mass-multiplied thermal resistance of the HHF HS is 32% smaller compared with the pin fin heat sink (PF HS). These interesting results are mainly due to integrated effects of the mass-reduction, the surface area enhancement, and the heat pumping via the internal channel. Such better performances of HF HSs show the feasibility of alternatives to the conventional PF HS especially for passive cooling of LED lighting modules.


2020 ◽  
Vol 319 ◽  
pp. 02004
Author(s):  
Muhammad Akif Rahman ◽  
Md Badrath Tamam ◽  
Md Sadman Faruque ◽  
A.K.M. Monjur Morshed

In this paper a numerical analysis of three-dimensional laminar flow through rectangular channel heat sinks of different geometric configuration is presented and a comparison of thermal performance among the heat sinks is discussed. Liquid water was used as coolant in the aluminum made heat sink with a glass cover above it. The aspect ratio (section height to width) of rectangular channels of the mini-channel heat sink was 0.33. A heat flux of 20 W/cm2 was continuously applied at the bottom of the channel with different inlet velocity for Reynold’s number ranging from 150 to 1044. Interconnectors and obstacles at different positions and numbers inside the channel were introduced in order to enhance the thermal performance. These modifications cause secondary flow between the parallel channels and the obstacles disrupt the boundary layer formation of the flow inside the channel which leads to the increase in heat transfer rate. Finally, Nusselt number, overall thermal resistance and maximum temperature of the heat sink were calculated to compare the performances of the modified heat sinks with the conventional mini channel heat sink and it was observed that the heat sink with both interconnectors and obstacles enhanced the thermal performance more significantly than other configurations. A maximum of 36% increase in Nusselt number was observed (for Re =1044).


2003 ◽  
Vol 125 (3) ◽  
pp. 319-324 ◽  
Author(s):  
C. B. Coetzer ◽  
J. A. Visser

This paper introduces a compact model to predict the interfin velocity and the resulting pressure drop across a longitudinal fin heat sink with tip bypass. The compact model is based on results obtained from a comprehensive study into the behavior of both laminar and turbulent flow in longitudinal fin heat sinks with tip bypass using CFD analysis. The new compact flow prediction model is critically compared to existing compact models as well as to the results obtained from the CFD simulations. The results indicate that the new compact model shows at least a 4.5% improvement in accuracy predicting the pressure drop over a wide range of heat sink geometries and Reynolds numbers simulated. The improved accuracy in velocity distribution between the fins also increases the accuracy of the calculated heat transfer coefficients applied to the heat sinks.


Author(s):  
Ali Kosar ◽  
Chih-Jung Kuo ◽  
Yoav Peles

An experimental study on thermal-hydraulic performance of de-ionized water over a bank of shrouded NACA 66-021 hydrofoil micro pin fins with wetted perimeter of 1030-μm and chord thickness of 100 μm has been performed. Average heat transfer coefficients have been obtained over effective heat fluxes ranging from 4.0 to 308 W/cm2 and mass velocities from 134 to 6600 kg/m2s. The experimental data is reduced to the Nusselt numbers, Reynolds numbers, total thermal resistances, and friction factors in order to determine the thermal-hydraulic performance of the heat sink. It has been found that prodigious hydrodynamic improvement can be obtained with the hydrofoil-based micro pin fin heat sink compared to the circular pin fin device. Fluid flow over pin fin heat sinks comprised from hydrofoils yielded radically lower thermal resistances than circular pin fins for a similar pressure drop.


2021 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Krzysztof Posobkiewicz ◽  
Krzysztof Górecki

Purpose The purpose of this study is to investigate the validation of the usefulness of cooling systems containing Peltier modules for cooling power devices based on measurements of the influence of selected factors on the value of thermal resistance of such a cooling system. Design/methodology/approach A cooling system containing a heat-sink, a Peltier module and a fan was built by the authors and the measurements of temperatures and thermal resistance in various supply conditions of the Peltier module and the fan were carried out and discussed. Findings Conclusions from the research carried out answer the question if the use of Peltier modules in active cooling systems provides any benefits comparing with cooling systems containing just passive heat-sinks or conventional active heat-sinks constructed of a heat-sink and a fan. Research limitations/implications The research carried out is the preliminary stage to asses if a compact thermal model of the investigated cooling system can be formulated. Originality/value In the paper, the original results of measurements and calculations of parameters of a cooling system containing a Peltier module and an active heat-sink are presented and discussed. An influence of power dissipated in the components of the cooling system on its efficiency is investigated.


2021 ◽  
Author(s):  
Mahyar Pourghasemi ◽  
Nima Fathi

Abstract 3-D numerical simulations are performed to investigate liquid sodium (Na) flow and the heat transfer within miniature heat sinks with different geometries and hydraulic diameters of less than 5 mm. Two different straight small-scale heat sinks with rectangular and triangular cross-sections are studied in the laminar flow with the Reynolds number up to 1900. The local and average Nusselt numbers are obtained and compared against eachother. At the same surface area to volume ratio, rectangular minichannel heat sink leads to almost 280% higher convective heat transfer rate in comparison with triangular heat sink. It is observed that the difference between thermal efficiencies of rectangular and triangular minichannel heat sinks was independent of flow Reynolds number.


2000 ◽  
Author(s):  
X. Wei ◽  
Y. Joshi

Abstract A novel heat sink based on a multi-layer stack of liquid cooled microchannels is investigated. For a given pumping power and heat removal capability for the heat sink, the flow rate across a stack of microchannels is lower compared to a single layer of microchannels. Numerical simulations using a computationally efficient multigrid method [1] were carried out to investigate the detailed conjugate transport within the heat sink. The effects of the microchannel aspect ratio and total number of layers on thermal performance were studied for water as coolant. A heat sink of base area 10 mm by 10 mm with a height in the range 1.8 to 4.5 mm (2–5 layers) was considered with water flow rate in the range 0.83×10−6 m3/s (50 ml/min) to 6.67×10−6 m3/s (400 ml/min). The results of the computational simulations were also compared with a simplified thermal resistance network analysis.


Author(s):  
D. Sahray ◽  
H. Shmueli ◽  
N. Segal ◽  
G. Ziskind ◽  
R. Letan

In the present work, horizontal-base pin fin heat sinks exposed to free convection in air are studied. They are made of aluminum, and there is no contact resistance between the base and the fins. For the same base dimensions the fin height and pitch vary. The fins have a constant square cross-section. The edges of the sink are blocked: the surrounding insulation is flush with the fin tips. The effect of fin height and pitch on the performance of the sink is studied experimentally and numerically. In the experiments, the heat sinks are heated using foil electrical heaters. The heat input is set, and temperatures of the base and fins are measured. In the corresponding numerical study, the sinks and their environment are modeled using the Fluent 6 software. The results show that heat transfer enhancement due to the fins is not monotonic. The differences between sparsely and densely populated sinks are analyzed for various fin heights. Also assessed are effects of the blocked edges as compared to the previously studied cases where the sink edges were exposed to the surroundings.