scholarly journals Degradation of acetaminophen in aqueous solution by UV and UV-activated sludge processes

2018 ◽  
Vol 78 (10) ◽  
pp. 2088-2095 ◽  
Author(s):  
Bingjie Xu ◽  
Guoyan Zhan ◽  
Bin Xu ◽  
Haijie Du ◽  
Hang Luo ◽  
...  

Abstract Acetaminophen (N-acetyl-p-aminophenol, APAP) is one of the most common antipyretic analgesics used to treat common ailments throughout the world. Recently, APAP has been frequently detected in wastewater effluent and groundwater, resulting in potential risks to the environment. Current methods for eliminating APAP are complicated and cost-prohibitive. This study examined APAP degradation by ultraviolet-C (UV-C) and UV-C irradiation combined with activated sludge (UV/AS) to evaluate potential applications in wastewater treatment. The results of this study indicate that UV-C irradiation reached an APAP degradation efficiency of more than 52% and a degradation rate of 0.0012–0.0013 min−1 during 720 min of exposure, while the initial APAP concentration exhibited only a nominal effect on the degradation rate. However, the UV/AS treatment demonstrated an APAP degradation rate that was 9.6 times the rate of the UV-C-only treatment, with a degradation efficiency of 99% over the same UV irradiation period. The results further indicated that APAP photolysis efficiency was more effective when applied to sterilized AS than when applied to unsterilized AS. Finally, excessive dosage of both AS and humic acid inhibited APAP photolysis efficiency.

1991 ◽  
Vol 24 (3-4) ◽  
pp. 427-430 ◽  
Author(s):  
J. Nevalainen ◽  
P.-R. Rantala ◽  
J. Junna ◽  
R. Lammi

Conventional and oxygen bleaching effluents from hardwood kraft pulp mills were treated in laboratory-scale activated sludge processes. The main interest was the fate of organochlorine compounds in the activated sludge process. In the treatment of conventional bleaching wastewaters the BOD7-reduction was 80-91 % and in oxygen bleaching wastewaters 86-93 %. The respective CODCr removals were about 40 % and about 50 %. The AOX reductions were on average 22 % and 40 % in the treatment of conventional and oxygen bleaching effluents, respectively. The reductions of chlorinated phenols, guajacols and catecols were usually more than 50 % in both reactors. Very little accumulation of AOX into the sludge was observed. The stripping of AOX from aeration unit was insignificant.


1992 ◽  
Vol 26 (3-4) ◽  
pp. 753-762 ◽  
Author(s):  
A. F. Rozich

The purpose of this paper is to present the background and examples of methodology which enable environmental engineers and scientists to analyze activated sludge processes much more effectively than is otherwise possible with conventional approaches. Good process analyses are key for devising optimal design and operational strategies. The key features to the technique presented herein are the field-proven predictability of the model and the methodology for collecting data needed for calibrating the process model. Case histories prove the predictability of the model that is associated with the process analysis approach. The advantage of the approach advocated herein is the use of respirometric techniques to calibrate the model. These methods enable the process analyst to collect the requisite data for model calibration in twenty-four hours or less. This feature enables one to use this process analysis methodology for both design and operational applications. The paper will present the technical basis for the process model and how respirometric methods are utilized to compute biokinetic constants in a manner which is consistent with kinetic theory. Case histories will be discussed that demonstrate the predictability of the modeling approach and demonstrate the utility of this tool for process analysis.


1998 ◽  
Vol 37 (12) ◽  
pp. 121-129 ◽  
Author(s):  
S. Isaacs ◽  
Terry Mah ◽  
S. K. Maneshin

A novel method is described to automatically estimate several key parameters affecting denitrification in activated sludge processes: the nitrate concentration, the denitrification capacity, and the maximum (substrate unlimited) and actual denitrification rates. From these, the concentration of active denitrifying microorganisms and the quality of available organic substrate pool can be estimated. Additionally, a modification of the method allows the determination of the efficacy of various carbon substrates to enhance denitrification, and this can be used to determine optimal dosing rates of an external carbon source. The method is based on measurements of either fluorescence or redox potential (ORP) in an isolated mini-reactor, the Biological Activity Meter (BAM), situated in the anoxic zone of the wastewater treatment plant. Advantages of the method are that it is in situ, operating at the same temperature as in the measured anoxic zone, requires no pumps or pipes for mixed liquor sampling, consumes little or no reagents, and uses measurement signals which are instantaneous and low maintenance, one of which provides a direct measure of biological activity.


1997 ◽  
Vol 35 (6) ◽  
pp. 37-44 ◽  
Author(s):  
Boran Zhang ◽  
Kazuo Yamamoto ◽  
Shinichiro Ohgaki ◽  
Naoyuki Kamiko

Activated sludges taken from full-scale membrane separation processes, building wastewater reuse system (400m3/d), and two nightsoil treatment plants (50m3/d) as well as laboratory scale membrane separation bioreactor (0.062m3/d) were analyzed to characterize membrane separation activated sludge processes (MSAS). They were also compared with conventional activated sludges(CAS) taken from municipal wastewater treatment plants. Specific nitrification activity in MSAS processes averaged at 2.28gNH4-N/kgMLSS.h were higher than that in CAS processes averaged at 0.96gNH4-N/kgMLSS.h. The denitrification activity in both processes were in the range of 0.62-3.2gNO3-N/kgMLSS.h without organic addition and in the range of 4.25-6.4gNO3-N/kgMLSS.h with organic addition. The organic removal activity in nightsoil treatment process averaged at 123gCOD/kgMLSS.h which was significantly higher than others. Floc size distributions were measured by particle sedimentation technique and image analysis technique. Flocs in MSAS processes changed their sizes with MLSS concentration changes and were concentrated at small sizes at low MLSS concentration, mostly less than 60 μm. On the contrary, floc sizes in CAS processes have not much changed with MLSS concentration changes and they were distributed in large range. In addition, the effects of floc size on specific nitrification rate, denitrification rate with and without organic carbon addition were investigated. Specific nitrification rate was decreased as floc size increased. However, little effect of floc size on denitrification activity was observed.


2000 ◽  
Vol 42 (12) ◽  
pp. 189-200 ◽  
Author(s):  
G.-H. Chen ◽  
H.-K. Mo ◽  
S. Saby ◽  
W.-k. Yip ◽  
Y. Liu

Minimization of excess sludge production in activated sludge processes has been pursued around the world in order to meet stringent environmental regulations on sludge treatment and disposal. To achieve this goal, physical, chemical, and biological approaches have been proposed. In this paper, a chemical compound, 3,3′,4′,5-tetrachlorosalicylanilide (TCS) was tested for enhancing microbial energy spilling of the sludgeso as to minimize its growth. In order to examine this, an exploratory study was conducted using both batch and continuous activated sludge cultures. Batch experiments with these two cultures were carried out at different initial concentrations of TCS. It has been confirmed that an addition of TCS is effective in reducing the production of both the sludge cultures, particularly the continuous culture where the observed growth yield was reduced by around 70%, when the initial TCS concentration was 0.8 ppm. Meanwhile, the substrate removal activity of this culture was found not to be affected at this TCS concentration. To further evaluate the TCS effect, a pure microbial culture of E. coli was employed. Batch experiment results with this culture implied that TCS might be able to reduce the cell density of E. coli drastically when an initial TCS concentration was greater than 0.12 ppm. It was also found that TCS was not toxic to this type of bacteria. Microscopic examinations with a 4′, 6-diamidino-2-phenylindole (DAPI) staining technique revealed that TCS neither affected the cell division nor altered the cell size of E. coli. However, both the cell ATP content and the cell dry weight were reduced significantly with the addition of TCS.


2020 ◽  
Vol 41 (S1) ◽  
pp. s33-s33
Author(s):  
Michihiko Goto ◽  
Erin Balkenende ◽  
Gosia Clore ◽  
Rajeshwari Nair ◽  
Loretta Simbartl ◽  
...  

Background: Enhanced terminal room cleaning with ultraviolet C (UVC) disinfection has become more commonly used as a strategy to reduce the transmission of important nosocomial pathogens, including Clostridioides difficile, but the real-world effectiveness remains unclear. Objectives: We aimed to assess the association of UVC disinfection during terminal cleaning with the incidence of healthcare-associated C. difficile infection and positive test results for C. difficile within the nationwide Veterans Health Administration (VHA) System. Methods: Using a nationwide survey of VHA system acute-care hospitals, information on UV-C system utilization and date of implementation was obtained. Hospital-level incidence rates of clinically confirmed hospital-onset C. difficile infection (HO-CDI) and positive test results with recent healthcare exposures (both hospital-onset [HO-LabID] and community-onset healthcare-associated [CO-HA-LabID]) at acute-care units between January 2010 and December 2018 were obtained through routine surveillance with bed days of care (BDOC) as the denominator. We analyzed the association of UVC disinfection with incidence rates of HO-CDI, HO-Lab-ID, and CO-HA-LabID using a nonrandomized, stepped-wedge design, using negative binomial regression model with hospital-specific random intercept, the presence or absence of UVC disinfection use for each month, with baseline trend and seasonality as explanatory variables. Results: Among 143 VHA acute-care hospitals, 129 hospitals (90.2%) responded to the survey and were included in the analysis. UVC use was reported from 42 hospitals with various implementation start dates (range, June 2010 through June 2017). We identified 23,021 positive C. difficile test results (HO-Lab ID: 5,014) with 16,213 HO-CDI and 24,083,252 BDOC from the 129 hospitals during the study period. There were declining baseline trends nationwide (mean, −0.6% per month) for HO-CDI. The use of UV-C had no statistically significant association with incidence rates of HO-CDI (incidence rate ratio [IRR], 1.032; 95% CI, 0.963–1.106; P = .65) or incidence rates of healthcare-associated positive C. difficile test results (HO-Lab). Conclusions: In this large quasi-experimental analysis within the VHA System, the enhanced terminal room cleaning with UVC disinfection was not associated with the change in incidence rates of clinically confirmed hospital-onset CDI or positive test results with recent healthcare exposure. Further research is needed to understand reasons for lack of effectiveness, such as understanding barriers to utilization.Funding: NoneDisclosures: None


Polymers ◽  
2021 ◽  
Vol 13 (5) ◽  
pp. 801
Author(s):  
Talita Nicolau ◽  
Núbio Gomes Filho ◽  
Andrea Zille

In normal conditions, discarding single-use personal protective equipment after use is the rule for its users due to the possibility of being infected, particularly for masks and filtering facepiece respirators. When the demand for these protective tools is not satisfied by the companies supplying them, a scenario of shortages occurs, and new strategies must arise. One possible approach regards the disinfection of these pieces of equipment, but there are multiple methods. Analyzing these methods, Ultraviolet-C (UV-C) becomes an exciting option, given its germicidal capability. This paper aims to describe the state-of-the-art for UV-C sterilization in masks and filtering facepiece respirators. To achieve this goal, we adopted a systematic literature review in multiple databases added to a snowball method to make our sample as robust as possible and encompass a more significant number of studies. We found that UV-C’s germicidal capability is just as good as other sterilization methods. Combining this characteristic with other advantages makes UV-C sterilization desirable compared to other methods, despite its possible disadvantages.


2020 ◽  
Vol 41 (S1) ◽  
pp. s292-s292
Author(s):  
William Rutala ◽  
Hajime Kanamori ◽  
Maria Gergen ◽  
Emily Sickbert-Bennett ◽  
David Jay Weber

Background:Candida auris is an emerging fungal pathogen that is often resistant to major classes of antifungal drugs. It is considered a serious global health threat because it has caused severe infections with frequent mortality in over a dozen countries. C. auris can survive on healthcare environmental surfaces for at least 7 days, and it causes outbreaks in healthcare facilities. C. auris has an environmental route of transmission. Thus, infection prevention strategies, such as surface disinfection and room decontamination technologies (eg, ultraviolet [UV-C] light), will be essential to controlling transmission. Unfortunately, data are limited regarding the activity of UV-C to inactivate this pathogen. In this study, a UV-C device was evaluated for its antimicrobial activity against C. auris and C. albicans. Methods: We tested the antifungal activity of a single UV-C device using the vegetative bacteria cycle, which delivers a reflected dose of 12,000 µW/cm2. This testing was performed using Formica sheets (7.6 × 7.6 cm; 3 × 3 inches). The carriers were inoculated with C. auris or C. albicans and placed horizontal on the surface or vertical (ie, perpendicular) to the vertical UV-C lamp and at a distance from 1. 2 m (~4 ft) to 2.4 m (~8 ft). Results: Direct UV-C, with or without FCS (log10 reduction 4.57 and 4.45, respectively), exhibited a higher log10 reduction than indirect UV-C for C. auris (log10 reduction 2.41 and 1.96, respectively), which was statistically significant (Fig. 1 and Table 1). For C. albicans, although direct UV-C had a higher log10 reduction (log10 reduction with and without FCS, 5.26 and 5.07, respectively) compared to indirect exposure (log10 reduction with and without FCS, 3.96 and 3.56, respectively), this difference was not statistically significant. The vertical UV had statistically higher log10 reductions than horizontal UV against C. auris and C. albicans with FCS and without FCS. For example, for C. auris with FCS the log10 reduction for vertical surfaces was 4.92 (95% CI 3.79, 6.04) and for horizontal surfaces the log10 reduction was 2.87 (95% CI, 2.36–3.38). Conclusions:C. auris can be inactivated on environmental surfaces by UV-C as long as factors that affect inactivation are optimized (eg, exposure time). These data and other published UV-C data should be used in developing cycle parameters that prevent contaminated surfaces from being a source of acquisition by staff or patients of this globally emerging pathogen.Funding: NoneDisclosures: None


2004 ◽  
Vol 94 (2) ◽  
pp. 95-110 ◽  
Author(s):  
M.G. Kramer

AbstractThe ability to insert foreign genes into arthropod genomes has led to a diverse set of potential applications for transgenic arthropods, many of which are designed to advance public health or improve agricultural production. New techniques for expressing foreign genes in arthropods have now been successfully used in at least 18 different genera. However, advances in field biology are lagging far behind those in the laboratory, and considerable work is needed before deployment in nature can be a reality. A mechanism to drive the gene of interest though a natural population must be developed and thoroughly evaluated before any field release, but progress in this area has been limited. Likewise, serious consideration of potential risks associated with deployment in nature has been lacking. This review gives an overview of the most promising techniques for expressing foreign genes in arthropods, considers the potential risks associated with their deployment, and highlights the areas of research that are most urgently needed for the field to advance out of the laboratory and into practice.


Sign in / Sign up

Export Citation Format

Share Document