scholarly journals An In Vitro Study of The Spore Densities Effect of Trichoderma spp. as Biocontrol Agent for Fusarium Wilt in Cayenne Pepper (Capsicum sp.)

Author(s):  
Ika Afifah Nugraheni ◽  
Tsania Taskia Nabila ◽  
Rais Sulistyo Widiyatmoko

Root disease controlling has been a challenge in increasing plant productivity. The soil-borne pathogens become the main concern which mostly infects the root surface. One of the most common soil-borne pathogens is Fusarium oxysporum (Fo). Cayenne pepper (Capsicum sp.) is one of the most abundant commodities and contributes significantly to the economy. This plant is also susceptible to Fusarium wilt infection. The use of endophytic fungi as biocontrol agents is an alternative against soil-borne pathogens, one of which is Trichoderma spp. fungi. This study aims to determine the effectiveness of various spore densities of Trichoderma spp. against the pathogen Fo. The research was conducted through an in vitro study by antagonistic testing between spore suspensions of Trichoderma spp. (103, 105, and 107 spores/mL) with Fo. The results showed the density of 107 spores/mL gave the highest percentage of inhibition (54.59%) compared to spore density of 103 (35.27%) and 105 spores/mL (44.44%). The spore density of 107 spores/mL gave a significant difference in response to the density of other spores according to the BNT test at a significance level of 5% and was able to inhibit the growth of Fo more than 50%. The results of this study are expected to be a reference for the formulation of Trichoderma spp. which is ideal for controlling Fo pathogens in the fields.

2021 ◽  
Vol 11 (2) ◽  
pp. 857
Author(s):  
Keunbada Son ◽  
Kyu-Bok Lee

The purpose of this in vitro study was to evaluate marginal and internal fits of ceramic crowns fabricated with chairside computer-aided design and manufacturing (CAD/CAM) systems. An experimental model based on ISO 12836:2015 was digitally scanned with different intraoral scanners (Omnicam (CEREC), EZIS PO (DDS), and CS3500 (Carestream)). Ceramic crowns were fabricated using the CAD/CAM process recommended by each system (CEREC, EZIS, and Carestream systems; N = 15). The 3-dimensional (3D) marginal and internal fit of each ceramic crown was measured using a 3D inspection software (Geomagic control X). Differences among the systems and various measurements were evaluated using the Kruskal–Wallis test. Statistically significant differences were validated using pairwise comparisons (α = 0.05). Occlusal gaps in the CEREC, EZIS, and Carestream groups were 113.0, 161.3, and 438.2 µm, respectively (p < 0.001). The axial gaps were 83.4, 78.0, and 107.9 µm, respectively. The marginal gaps were 77.8, 99.3, and 60.6 µm, respectively, and the whole gaps were 85.9, 107.3, and 214.0 µm, respectively. Significant differences were observed with the EZIS system compared with the other two systems in terms of the marginal gap sizes. The CEREC system showed no significant differences among the four measured regions. However, the EZIS and Carestream systems did show a statistically significant difference (p < 0.05). All three systems were judged to be capable of fabricating clinically acceptable prostheses, because the marginal gap, which is the most important factor in the marginal fit of prostheses, was recorded to be below 100 µm in all three systems.


Author(s):  
Royan Diana ◽  
Hedijanti Joenoes ◽  
Ariadna A Djais

Objective: This study aimed to compare the effect of Curcuma xanthrorrhiza ethanol extract to the viability of Streptococcus mutans and Aggregatibacter  actinomycetemcomitans using single- and dual-species biofilm at different phases of formation.Methods: Biofilm models were incubated for 4, 12, and 24 hrs, then exposed to the extract at a concentration of 0.525%.Results: The viability of the single-species S. mutans biofilm was low (p<0.05), and no significant difference (p>0.05) was found between singlespeciesA. actinomycetemcomitans and dual-species biofilm.Conclusions: Curcuma xanthorrhiza ethanol extract is more effective for decreasing the viability of single-species S. mutans biofilm.


2020 ◽  
Vol 24 (1) ◽  
pp. 21-28
Author(s):  
Ediz Kale ◽  
Ayça Deniz İzgi ◽  
Remzi Niğiz

SummaryBackground/Aim: The purpose of this in-vitro study was to compare the resin-bonded fixed partial dentures (RBFPD) fabricated using two different structural designs and two different antibacterial adhesive lutting protocols in regard to their resistance to debonding.Material and Methods: Forty samples for a model with single missing molar were divided into 4 groups (M1, M2, C1, C2) (n=10). M1 and M2 were prepared in accordance with modified inlay slot-cavity retained RBFPD design; C1 and C2 were prepared according to conventional inlay slot-cavity retained RBFPD design. M1 and C1 cavities were treated with 2% chlorhexidine-based (CHX) cavity disinfectant and 10-methacryloyloxydecyl dihydrogen phosphate (MDP) containing adhesive system; M2 and C2 cavities were treated with MDP and 12-methacryloyloxydodecylpyridinium bromide (MDPB) containing adhesive system featuring antibacterial cavity cleansing effect. The RBFPDs were made of base-metal alloy and their fit surfaces sandblasted with aluminium oxide (Al2O3). Adhesive resin cement was used for cementation, and the RBFPD retainers were interlocked into their corresponding inlay cavities using composite resin. After 1 week being immersed in aqueous environment, the RBFPDs were subjected to tensile loading at a crosshead speed of 1 mm/min until failure. One way ANOVA and Tukey HSD tests were used for statistical evaluation (α=0.05). Mode of failure and tooth damage was also noted.Results: Mean tensile bond strength values were 356 N for M1, 305 N for M2, 467 N for C1, and 455 N for C2. Tensile strength values of C1 and C2 were significantly higher than those of M1 and M2 (p<0.05). The mode of failure was mostly adhesive in character at the metal-cement interface in all groups. Tooth fracture was observed nearly in all specimens. No significant difference was detected between the antibacterial adhesive lutting protocols (p>0.05).Conclusions: The RBFPDs with the conventional design were found to be more retentive than those with the modified design. Using an adhesive system featuring antibacterial properties with no need of separate antibacterial agent application during bonding may be favourable.


Author(s):  
Prabhjeet S ◽  
Meena A K ◽  
Jesil M

Objective: The objective of the study was to evaluate the efficacy of Ganoderma lucidum toothpaste as an antiplaque agent and to compare its efficacy with herbal toothpaste and mouthwash.Methods: Pooled saliva was collected in a sterile container from the volunteers after taking the consent. Tissue culture plate with 12 (3 × 4) wells was chosen. Pooled saliva of 20 mL was added to each well using the micropipette and was kept in the incubator at 37°C for 72 h. After 72 h, saliva was removed without touching the walls or the base of the wells. Each row was treated either with slurry prepared with Ganoderma/herbal/Colgate total toothpaste or herbal/chlorhexidine mouthwash/distilled water. One row of wells was kept as a control using erythrosine dye. After 30 s, all the wells were rinsed with distilled water. Erythrosine dye was added to all the wells, kept for 30 s, and rinsed with distilled water. The tissue culture plate was kept in the ELx800MS machine (ELISA reader) which was set at 540 nm, and the readings were obtained.Results: The results showed that G. lucidum toothpaste slurry reduced plaque than herbal and chlorhexidine mouthwash. However, there was no significant difference in plaque reduction between herbal and G. lucidum toothpaste slurries.Conclusion: The present study concluded that G. lucidum had better antiplaque efficacy than herbal toothpaste, herbal mouthwash, and chlorhexidine mouthwash.


2017 ◽  
Vol 05 (01) ◽  
pp. 039-046 ◽  
Author(s):  
Monica Sharma ◽  
Ajay Bansal ◽  
Sunny Panthi ◽  
Shefali Malik ◽  
Atulya Sharma

Abstract Purpose: The purpose of this in vitro study was to evaluate marginal fit of cobalt- chromium (Co-Cr) copings fabricated by direct metal laser sintering system (DMLS) and conventional lost-wax technique (LW). Materials and method: Forty tooth preparations were carried out over extracted mandibular molars. They were divided into two groups A and B of 20 each. For group A Co-Cr copings were fabricated by direct metal laser sintering (DMLS) and for group B by lost wax technique (LW). Glass –ionomer cement (GIC) was used to tack the copings over their preparations. Marginal fit was then evaluated directly under the stereomicroscope. Results: The mean marginal gap of group A was 27.9 ± 2.4 μm and group B was 40.4 ±6 μm. Statistical analysis using t - test showed highly significant difference (P>.05) between the marginal mean of the DMLS (group A) compared to LW (group B). Conclusion: The DMLS copings demonstrated superior marginal fit compared to that of conventional Co-Cr casted copings.


2012 ◽  
Vol 2012 ◽  
pp. 1-5 ◽  
Author(s):  
Basawaraj Biradar ◽  
Sudharani Biradar ◽  
Arvind MS

Objectives. The objective of this in vitro study was to investigate whether weight gain or loss in the three different composites occurs due to water absorption when they are stored in water.Methods. The composite restorative materials selected for this study included a microfine hybrid (Synergy) and two nanofilled composite restorative materials (Ceram X and Filtek Supreme Ultra). Twenty specimens of each material were fabricated of each composite material. Group A: Filtek Supreme Ultra, Group B: Synergy, Group C: Ceram X. Then all the specimens were stored in 10 ml Distilled water containing test tubes and placed in incubator at 37°C for six weeks. The weight changes of these specimens were measured daily for the first week and later once a week for next five weeks by using an electrical analytical balance.Results.The data was analyzed by one-way analysis of variance and Student'sttest. All groups showed maximum amount of water absorption in the first week than gradual decrease in the water absorption from the second to the sixth week, as compared to the first week and there is no statistically significant difference between the groups tested.Conclusion. All the composite restorative material absorbs some amount of water. The water absorption of the composite may decrease the physical and mechanical properties of the composites; hence it is necessary to consider the type of the material before starting the treatment.


2013 ◽  
Vol 70 (3) ◽  
pp. 279-283
Author(s):  
Mirjana Apostolovic ◽  
Biljana Kalicanin ◽  
Marija Igic ◽  
Olivera Trickovic-Janjic ◽  
Dusan Surdilovic ◽  
...  

Bacground/Aim. Glass ionomer cements (GIC) belong to the group of polycarboxyl cements, and one of the principal characteristics of these materials is their anticariogenic potential of fluorine release into saliva and enamel-dentin substance. The aim of this study was to examine the content of released fluorine from GIC restorations (Fuji IX, GC, Japan) of young permanent teeth in the medium of artificial saliva and similar releases in the same medium by the restorations of these teeth treated with a low concentration fluoride solution. Methods. We examined 12 premolars exctracted from orthodontic reasons. The GIC restored teeth were divided into the group treated daily with low concentration fluoride solution (334 ppm) and the control, not treated group. The samples of artificial saliva were analyzed for fluorine ion content using an ion selective electrode. Results. Our comparative analysis of the mean values using the Student?s t-test demonstrated a statistically significant difference in fluorine ion concentration in artificial saliva of fluoridated and non-fluoridated teeth with GIC fillings after 14 and 21 days (p < 0.05), while the difference detected after 7 days was with no statistical significance. Conclusion. The results of this in vitro study indicated that low-concentration fluoride solutions could serve to refluoridate GIC fillings and contribute to an increased fluorine content in saliva. The process of refluoridation of GIC fillings should be advised 2-3 weeks after the restoration, since the release of fluorine from GIC fillings diminishes in time.


2002 ◽  
Vol 26 (4) ◽  
pp. 371-375 ◽  
Author(s):  
Ana Beatriz Alonso Chevitarese ◽  
Orlando Chevitarese ◽  
Ivete Pomarico Ribeiro de Souza ◽  
Roberto Braga de Carvalho Vianna

The aim of this study was to evaluate the influence of prophylaxis on the sealants microleakage in 30 premolars divided into: Group A, Group B and Group C. The teeth were analyzed using the optical microscope (OM) and at scanning electron microscope (SEM). There was a statitical significant difference among the groups regarding the presence of microleakage, but not with the presence of tags.


2021 ◽  
Vol 13 (2) ◽  
pp. 47-51
Author(s):  
Samaneh Abbasi ◽  
Soodabe Ebrahimi ◽  
Arash Shisheian ◽  
Maryam Farhadian

Background: Acrylic resin teeth wear resistance has an important role in the denture longevity. This study aimed to clarify the effect of glaze coating on wear resistance of three types of artificial acrylic teeth. Methods: In this in vitro study, the wear resistance rate of three of acrylic denture teeth (GENIUS, STON and CLASSIC) was compared with Ivoclar teeth (n=25/group). The wear resistance was measured by estimating the weight loss in pre and post removing glaze coating, following 5000 cycles in the chewing simulator device. Data analysis was made using paired t test, one-way ANOVA and Tukey’s post hoc test. Results: ANOVA test showed that there was no significant difference between the mean amount of wear of GENIUS, CLASSIC, STON and IVOCLAR teeth in the first stage (P <0.061), but this difference was significant (P <0.001) in the second stage. The result of Tukey post hoc test showed that wear rates of GENIUS were significantly lower than other groups (P<0.001). Comparison between the mean wear rates of each dental group at the first and second stages showed a significant difference between average teeth wear resistance of CLASSIC, STON and IVOCLAR in the first and second stages (P <0.001). Conclusions: In conclusion, the teeth wear resistance of STON and CLASSIC were similar to IVOCLAR. Also, after removing the glaze coating, the teeth wear resistance decreased in all groups but was not statistically significant for group GENIUS.


2020 ◽  
Vol 23 (3) ◽  
Author(s):  
Saeedeh Galledar ◽  
Robab Farhang ◽  
Malek Abazari ◽  
Parisa Negahdar

Objective: Proper apical seal plays an important role in the success of root canal treatment. The most common cause of failure of root canal therapy is known as the lack of adequate apical seal. The aim of this in vitro study was to compare the apical microleakage of MTA Fillapex, , and Endofill sealers using dye penetration method. Material and Methods: In this in vitro study, 72 single-rooted extracted human teeth were selected. The teeth were randomly divided into three experimental groups of 20 and two positive and negative control groups of 6. The canals were prepared by step-back technique and then filled with gutta-percha and one of the sealers mentioned. In the positive control group, the canals were filled with gutta-percha without sealer, and in the negative control group, the canals were prepared but not filled. The teeth were immersed in 2% methylene blue dye for 72 hours. The teeth were then cut longitudinally and the level of dye penetration was measured under a stereomicroscope. Data were analyzed by SPSS ver. 19 software, ANOVA and Bonferroni post-hoc tests. Results: The mean level of dye penetration in the Endofill test group was significantly higher than that in the  and MTA Fillapex test groups. While, the observed difference between  and MTA Fillapex groups was not statistically significant (p<0.05). Conclusion: The results of this study showed that  and MTA Fillapex sealers did not show any significant difference in apical seal properties. However, their sealing strength was significantly greater than Endofill sealer.KeywordsAH26 sealer; Endofill; MTA Fillapex; Microleakag