Analisis Tingkat Pencemaran Air Sungai Krueng Tamiang Terhadap COD, BOD dan TSS

2020 ◽  
Vol 5 (3) ◽  
Author(s):  
Bahagia Bahagia ◽  
Suhendrayatna Suhendrayatna ◽  
Zulkifli Ak

Industrial waste is a factor influencing the pollution of the Krueng Tamiang river. The purpose of this study was to analyze the level of water pollution in the Krueng Tamiang river with the parameters of Biochemical Oxygen Demand (BOD), Chemical Oxygen Demand (COD) and Total suspended Solid (TSS) parameters. The results showed the highest BOD parameter test results came from location 2 (Seumadam Bridge) of 3.63 mg / L at stage IV and the lowest BOD value at locations 1 and 6 (Kaloy Village and Alur Manis Bridge) at stage I of 2 mg / L. The highest COD parameter test results came from location 5 (Kota Lintang Bridge) of 21.0 mg / L at stage III and the lowest COD value at location location 1 (Kaloy Village) at stage III, points 1, 3 and 6 (Kaloy Village, Kebon Tengah Suspension Bridge and Alur Manis Bridge) at stage IV of 17.0 mg / L. The highest TSS parameter test results came from location 7 (Peukan Seuruway), namely 295 mg / L phase I in the dry season, and the lowest TSS value at location 1 (Kaloy Village), which was 11 mg / L in stage III during the rainy season.

2020 ◽  
Vol 15 (3) ◽  
pp. 70-77
Author(s):  
J.D Bala ◽  
F. A Kuta ◽  
N.U Adabara ◽  
O.P Abioye ◽  
H.S Auta ◽  
...  

Water used for washing carcasses of slaughtered animals and slaughter house is referred to as abattoir wastewater. This study was designed to investigate the microorganisms associated with abattoir wastewater and to establish the biodegradation potential of abattoir wastewater microbiota. Isolation of the microbes was carried out using pour plate technique. The total viable count for the microbes’ ranges from 2.5×104 - 4.6×105 cfu/mL. Results revealed that all the physicochemical parameters exceeded the permissible limits (total dissolved solid (TDS) 1748mg/L, total suspended solid (TSS) 176mg/L, biochemical oxygen demand (BOD5) 91 mg/L and chemical oxygen demand (COD) 227 mg/L). Microorganisms isolated include Staphylococcus aureus, Pseudomonas aeruginosa, Bacillus subtilis, Bacillus anthracis, Aspergillus niger, A. flavus, Mucor sp, Trichophyton quickeanum and Penicillium sp. Some of the microbes were observed to have biodegradation potential by their ability to grow on mineral salt media (MSM) incorporated with starch, cellulose, crude oil, kerosene and diesel as the sole source of carbon and energy. This study suggests that abattoir wastewater harbors microorganisms that could be hazardous to public health when discharged into the environment untreated hence the need for strict monitoring. These microbes isolated could be employed as agent of bioremediation of wastewaters. Key words: Abattoir; Biodegredation; Isolation; Microbiota; Wastewater


Jurnal Ecolab ◽  
2021 ◽  
Vol 15 (2) ◽  
pp. 101-109
Author(s):  
Dewi Ratnaningsih ◽  
◽  
Retno Puji Lestari ◽  
Ernawita Nazir

Kualitas air di suatu wilayah yang merupakan salah satu indikator lingkungan dapat dievaluasi menggunakan parameter fisika, kimia, dan biologi. Indeks Kualitas Air Indonesia (IKA-INA) dapat digunakan untuk menilai kondisi kualitas air secara menyeluruh pada lokasi dan waktu tertentu. IKA-INA dihitung dengan menggunakan sepuluh (10) parameter yaitu pH, Total Dissolved Solid (TDS), Total Suspended Solid (TSS), Dissolved Oxygen (DO), Biological Oxygen Demand (BOD), Chemical Oxygen Demand (COD), NO3, NH3, Total Phosphate (TP) dan fecal coliform. IKA-INA tersebut merupakan indeks kualitas air yang dapat memberikan informasi secara sederhana. Dalam pemanfaatannya, tidak semua data parameter dalam IKA-INA tersebut dapat terpenuhi karena adanya data tidak valid atau data yang hilang. Kajian ini bertujuan untuk memberi alternatif rumusan IKA-INA dengan parameter yang tidak lengkap atau jika tidak semua data dalam parameters tersebut tersedia. Metode yang digunakan dalam menyusun rumusan adalah dengan melakukan koreksi faktor bobot parameter IKA-INA terhadap parameter yang hilang dan nilai Q (nilai sub-indeks). Setelah itu dilakukan uji coba pada nilai baku mutu air dalam Peraturan Pemerintah No. 22/2021 Lampiran VI serta pada data kualitas air sungai yang mewakili kualitas baik dan buruk. Hasil uji coba menunjukkan bahwa bobot parameter terkoreksi dapat digunakan untuk penanganan parameter yang hilang dalam penilaian kualitas air dengan metode IKA-INA. Hasil IKA-INA dengan parameter hilang yang menggunakan bobot terkoreksi dan hasil IKA-INA dengan parameter lengkap mayoritas memberikan status IKA yang tidak berbeda, kecuali untuk parameter fecal coli dan parameter yang mempunyai kadar jauh berbeda terhadap kondisi air secara keseluruhan.


2018 ◽  
Vol 67 ◽  
pp. 04006 ◽  
Author(s):  
Irfan Aditya ◽  
Sutrasno Kartohardjono

Wastewater generated from the tofu industry usually still contains high organic pollutants that can contaminate the surface water. Therefore, it should be treated properly before it can be disposed to the environment. This study aims to evaluate the combination of coagulationflocculation and ultrafiltration methods in treating the wastewater from tofu industry. Based on the preliminary tests, the wastewater from tofu industry have pH, total dissolved solid (TDS), total suspended solid (TSS), turbidity and chemical oxygen demand (COD) of 3.4, 870 - 1080 mg/L, 370 mg/L, 446 FAU and 7954 mg/L, respectively. The coagulant and membrane used in this study were Poly aluminum chloride (PAC) and the ceramic membrane, respectively. Experimental results showed that the best pH for coagulation-flocculation process is at pH of 7.0, and this pH was then used for ultrafiltration process. The flux of the ultrafiltration membrane increased with increasing the trans membrane pressure due to increasing driving force. The observed parameters such as TSS and turbidity of wastewater decreased drastically after experiencing ultrafiltration process and met the National Environmental Quality Standard. However, the COD of water produced in the ultrafiltration process was still high and did not meet the National Environmental Quality Standard.


2020 ◽  
Vol 32 (4) ◽  
pp. 827-834
Author(s):  
Muhammad Towhid Moula ◽  
Ranjit K. Nath ◽  
Mh. Mosfeka Chowdhury ◽  
Md. Abu Bakar Siddique

Halda is an important river of Bangladesh, is now polluted in different ways through industrial, agricultural, domestic and sewage disposal. Increased anthropogenic activities have increased the potential pollution of the river and excessive pollutants may be toxic to humans and aquatic fauna. Presence of heavy metals in the river water causes perilous impact on the aquatic organisms. Hence, regular monitoring of pollution levels in the river is indispensable. In this study, we discuss about physico-chemical assessments of water quality parameters viz. pH, dissolve oxygen (DO), biochemical oxygen demand (BOD), chemical oxygen demand (COD), total solid (TS), total suspended solid (TSS), total dissolved substance (TDS), total alkalinity, turbidity, salinity, electrical conductivity (EC), hardness, chloride and heavy metals in the water of Halda river during rainy and winter seasons, at different points; sources of pollutants in water and their effects given starting from the early research until the current research.


2012 ◽  
Vol 610-613 ◽  
pp. 363-367
Author(s):  
Tipakorn Suwannarat ◽  
Nipon Pisutpaisal ◽  
Siriorn Boonyawanich

The purpose of current study was to examine the ability of electrocoagulation in decreasing chemical oxygen demand (COD) and total suspended solid (TSS) constituted in palm oil mill effluent. Bench-scale batch reactor containing two aluminum or steel plates (10 cm width × 30 cm height with 0.1 cm thickness) serving as electrodes with the interval distance of 3 cm was set up. The wastewater with COD concentration of 68,425 mg L-1 was treated in the reactor under the varied direct currents (0.3-1.3 A) and contact time (30-120 min). Sodium chloride was added to the wastewater to obtain the final concentration of 2 g L-1 (conductivity of 10 ms) prior to being fed into the reactor. The results showed that higher treatment efficiency when the aluminum was used as electrodes compared to the steel. COD removal efficiency was directly proportional to the contact time. The maximum COD and TSS removal observed at 1.3 A current input and 60 min contact time are 74.1 and 77.0%, respectively.


2020 ◽  
Vol 997 ◽  
pp. 139-149
Author(s):  
Yong Yin Sia ◽  
Ivy Ai Wei Tan ◽  
Mohammad Omar Abdullah

Palm oil processing is a multi-stage operation which generates large amount of palm oil mill effluent (POME). Due to its potential to cause environmental pollution, POME must be treated prior to discharge. Electrocoagulation (EC), adsorption (AD), combined EC and AD, and EC integrated with AD have demonstrated great potential to remove various organic and inorganic pollutants from wastewater. Up to date, no study has been found on POME treatment using EC-AD hybrid process. Therefore, this study aims to investigate the feasibility of applying EC-AD hybrid process as an alternative treatment for POME. The EC-AD hybrid process achieved higher removal of total suspended solid (TSS), chemical oxygen demand (COD) and colour as compared to EC and AD stand-alone processes. The EC-AD hybrid process reduced 79% of TSS, 44% of COD and 89% of colour from POME. The adsorption kinetics of TSS, COD and colour were best interpreted using pseudo-second-order model, which indicated that the adsorption rate was mainly controlled by chemisorption. Overall, the EC-AD hybrid process could be recommended as an alternative treatment for POME.


2020 ◽  
Vol 8 ◽  
pp. 1
Author(s):  
Ismail Babatunde Onajobi ◽  
Hassan Adeyemi Sanuth ◽  
Sunday Ademola Laba ◽  
Abdul-Azeez Olayiwola Sirajudeen

This study was carried out to investigate the microbial and physiochemical quality of common borehole water filter installations. Ten (10) borehole filter samples were collected from private homes in Ijebu-Ode, Southwestern Nigeria. These were analyzed using standard procedures. Antibiotic susceptibility of isolates was determined using the standard disc diffusion method. The temperature o oand pH range of filter samples recorded was 27.6 – 28.9C and 6.09 – 6.90C respectively. Total dissolved solid, total suspended solid and total dissolved oxygen of filter samples recorded ranged 3 3between 10 - 55mg/L, 0.5 x10 - 17.14 x 10mg/L and 4.7 - 9.7mg/L respectively. Chemical oxygen demand ranged from 9.5 - 13.25mg/L while biochemical oxygen demand ranged from 4.5 - 8.5mg/L. Total heterotrophic count, Salmonella-Shigella count and Escherichia coli count ranged from 16 x 3 5 3 5 3 510 - 52 x10, 0 x 10 - 12 x 10 and 0 x 10 - 12 x10 CFU/mL respectively. Faecal coliform count 3 5ranged from 0 x 10 - 12 x10 CFU/mL. Nine bacteria isolated and identified includes: Escherichia coli, Klebsiella species, Staphylococcus aureus, Pseudomonas species, Pseudomonas aeruginosa, Proteus species, Bacillus cereus, Enterobacter species and Salmonella species. Escherichia coli was sensitive to all antibiotics, except augmentin. The highest level of resistance was exhibited by Enterobacter sp. This study revealed that the borehole water filter from Ijebu-Ode is of poor microbial and physiochemical quality. Further work needs to evaluate the filter composition and quality. Disinfection of water in storage tanks before distribution is strongly recommended as a short term solution.


2014 ◽  
Vol 11 (2) ◽  
pp. 62 ◽  
Author(s):  
M Wawan Kurniawan ◽  
P Purwanto ◽  
S Sudarno

ABSTRAKIndustri batik menimbulkan dampak air limbah organik dalam jumlah yang besar, warnayang pekat, berbau menyengat dan memiliki suhu, keasaman (pH), Biochemical OxygenDemand (BOD), Chemical Oxygen Demand (COD) serta Total Suspended Solid (TSS) yangtinggi. Desa Banaran Kecamatan Grogol Kabupaten Sukoharjo merupakan sentra industriusaha mikro, kecil dan menengah (UMKM) batik yang potensial dalam mendukungperekonomian lokal namun belum memiliki sistem pengelolaan air limbah. Penelitian inibertujuan untuk menyusun strategi pengelolaan air limbah UMKM Batik di Desa Banarandalam perspektif good governance berdasarkan kajian aspek teknis, aspek ekonomi, aspekmanajemen dan aspek sosial dengan menggunakan analisis SWOT (Strength, Weakness,Opportunity and Threats) dilanjutkan penentuan prioritas strategi dengan metode AHP(Analytical Hierarchy Process). Untuk mengkaji keempat aspek tersebut maka dilakukanobservasi, dokumentasi, pengukuran, uji laboratorium di lokasi penelitian dan wawancaraterhadap stakeholders dalam pengelolaan air limbah UMKM Batik di Desa Banaran yaitupemerintah daerah, UMKM Batik, tokoh masyarakat dan sektor swasta pelaku CorporateSocial Responsibility (CSR) di Kabupaten Sukoharjo. Berdasarkan hasil analisis SWOT danmetode AHP menghasilkan prioritas strategi untuk mewujudkan pengelolaan air limbahUMKM Batik yaitu : (1) Aspek Manajemen : penyusunan kebijakan dan programpengelolaan air limbah UMKM Batik, (2) Aspek Teknis : penentuan lahan untuk InstalasiPengolahan Air Limbah (IPAL) yang representatif, (3) Aspek Ekonomi : swadana UMKMBatik dalam operasional dan perawatan IPAL dan (4) Aspek Sosial : pembinaan tekniskepada UMKM Batik dalam pengelolaan air limbah. Untuk mewujudkan pengelolaan airlimbah UMKM Batik secara optimal dan berkelanjutan diperlukan kerjasama dankemitraan yang baik di antara stakeholders sebagai perwujudan dari paradigma goodgovernance didalam kerangka pembangunan yang berkelanjutan.Kata kunci : pengelolaan air limbah UMKM batik, good governance, prioritas strategi


Sign in / Sign up

Export Citation Format

Share Document