scholarly journals The efficiency of the economic septic tank in the treatment of domestic wastewater and black water in rural areas

2021 ◽  
Vol 10 (8) ◽  
pp. e22910817232
Author(s):  
Guilherme Franceschini ◽  
Nathalie Dyane Miranda Slompo ◽  
Sergio Augusto Rodrigues ◽  
Valéria Cristina Rodrigues Sarnighausen ◽  
Jorge Lucas Junior

Wastewater treatment in rural areas is important to prevent the pollution of aquatic environments and to protect the health of the population. Centralized treatment systems present a high cost, making the use of decentralized systems attractive. The use of septic tanks for on-site treatment of residential (single-family) is an attractive alternative within the context of Brazilian sanitation. Thus, the main objective of this study was to analyze the efficiency of the Economic Septic Tank in the treatment of wastewater of two residences located in a rural area. Two systems were installed: the first treat sanitary wastewater of a residence with three residents (A) and the second treat only the water from the toilet of a residence with five residents (B) (Black Water). For both systems, A and B, removal efficiencies were obtained in relation to total suspended solid (75%), biochemical oxygen demand (58 and 55%), and chemical oxygen demand (61 and 60%), respectively. Removal efficiencies were close, indicating that the system works satisfactorily in both systems, considering values indicated in the literature.

2018 ◽  
Vol 7 (4.35) ◽  
pp. 22
Author(s):  
Gasim Hayder ◽  
Puniyarasen Perumulselum ◽  
Hitham Alhussian

Fixed bed biofilm reactors were evaluated with three different arrangements of bio-balls. The performance of different arrangements was evaluated based on chemical oxygen demand (COD), total suspended solid (TSS) and mixed liquor suspended solid (MLSS). The three rectors were fabricated and operated in lab scale model with real domestic wastewater. Considering the TSS removal efficiency, arrangement one was the best followed by arrangement two and arrangement three. While for COD, arrangement one recorded the highest removal efficiency followed by arrangement two and column. The average COD concentration for arrangement one was 23 while for arrangement two and arrangement three was 25 and 36 mg/l respectively. The overall average effluent TSS concentrations for the arrangement one, two and three were 25, 32 and 45 mg/l respectively. TSS and COD removal was almost the same for arrangement one and arrangement two but arrangement one has the highest among them, and all removal is acceptable under Malaysian standards. Besides that, all the three arrangements have the differences in terms of maintenance and installation. There was no clogging occurred in all the three arrangements.


2022 ◽  
Vol 10 (E) ◽  
pp. 6-11
Author(s):  
Zulfikar Zulfikar ◽  
Nasrullah Nasrullah ◽  
Kartini Kartini ◽  
Wiwit Aditama

BACKGROUND: Domestic wastewater can cause health problems and pollute groundwater sources. Such pollution not only has a negative impact on health and the environment, but also on the cost in providing clean water. AIM: The outcome of domestic wastewater treatment through a proper technique is expected to meet the clean water quality standard for sanitation purposes. MATERIALS AND METHODS: The experiment was conducted to determine the effect of Hydraulic Retention Time (HRT) on the levels of Biochemical Oxygen Demand (BOD) and Total Suspended Solid (TSS) of domestic wastewater. The experiment was carried out with 6 variations of HRT, namely 1 hour, 2 hours, 4 hours, 6 hours and 8 hours with 4 repetitions. The media running process was carried out for 14 days until the reactor condition was in steady state. RESULTS: The results showed that the removal values ​​for COD, Oil and Fat, Ammonia and Total Coliform parameters were 68.03%, 46.51%, 69.64% and 68.99%, respectively. Based on the variation of HRT of 1 hour, 2 hours, 4 hours, 6 hours and 8 hours on the BOD parameter, the removal values ​​obtained were 11.7%, 21.3%, 34.7%, 49.0% and 64.1%, respectively. Furthermore, for the TSS parameter, the values obtained were 17.3%, 25.4%, 30.6%, 42.3% and 50.4%, respectively. CONCLUSION: HRT was proven to have a significant effect on the levels of BOD and TSS of domestic wastewater with a p-value of <0.05 at the 95% confidence level


2020 ◽  
Vol 82 (4) ◽  
Author(s):  
Priyatharishini Mardarveran ◽  
Nadzirah Mohd Mokhtar

The chemical coagulants used in the process of wastewater treatment causes negative implications on environment and human health. Exploration on natural coagulants as environmental friendly solution has been widely carried out. In present research, Artocarpus heterophyllus (jackfruit) peel is used as coagulant in treating domestic wastewater. This study aimed to assess optimum pH of wastewater and coagulant dosage by varying them to achieve the maximum removal rate of total suspended solid (TSS), biological oxygen demand (BOD), chemical oxygen demand (COD) and turbidity. The studied range for pH of wastewater was pH 1-3 and dosage of coagulant within 50–70 mg/L. Response surface methodology (RSM) based on central composite design (CCD) implied in optimization of this coagulation process. Treatment using this natural coagulant enabled maximum reduction of turbidity, TSS, BOD and COD up to 80.7 %, 77.5 %, 34.3 % and 34.6 % respectively under optimum condition of pH 2.1 and dosage of 58 mg/L. These findings revealed higher reduction in turbidity and TSS. Thus, this study indicates the promising potential of the Artocarpus heterophyllus peel extract as an alternative bio-based coagulating agent for effective pre-treatment of wastewater. 


2019 ◽  
Vol 10 (2) ◽  
pp. 63-69
Author(s):  
Veronika Amelia Simbolon ◽  
Razor Armada ◽  
Rinaldi Daswito

Domestic wastewater is wastewater, if not treated it can cause pollution. One of the efforts to reduce levels of Total Suspended Solid (TSS) and Chemical Oxygen Demand (COD) is to treat domestic waste. This study uses a modified bubble aerator and filtration method with zeolite, beach sand, and activated charcoal as an effort to reduce the levels of COD and TSS in domestic wastewater. This research method is a pre-trial using the One Group Pretest Postest design. Measurement of results is done before and after calculation. The sampling technique uses purposive sampling. Data analysis performed was univariate and bivariate analysis. Paired statistical t-test was used to find out the difference in average TSS and COD levels before completion. Decreased TSS levels after training (79.36%) and COD after administration (13.48%). Paired t test results showed no difference before and after using the bubble aerator and filtration modification methods with p values ​​of 0.342 and 0.448, respectively. Modifications to the bubble aerator and filtration methods can be used to reduce TSS and COD levels in domestic wastewater, although statistics show insignificant results. It is hoped that further researchers will conduct further research to perfect the methods that had been estimated.    Keywords: TSS levels, COD, bubble-filtation aeration method


2013 ◽  
Vol 68 (4) ◽  
pp. 956-964 ◽  
Author(s):  
Tarek Elmitwalli

Although the septic tank is the most applied on-site system for wastewater pre-treatment, limited research has been performed to determine sludge accumulation and biogas production in the tank. Therefore a dynamic mathematical model based on the Anaerobic Digestion Model No. 1 (ADM1) was developed for anaerobic digestion of the accumulated sludge in a septic tank treating domestic wastewater or black water. The results showed that influent chemical oxygen demand (COD) concentration and hydraulic retention time (HRT) of the tank mainly control the filling time with sludge, while operational temperature governs characteristics of the accumulated sludge and conversion to methane. For obtaining stable sludge and high conversion, the tank needs to be operated for a period more than a year without sludge wasting. Maximum conversion to methane in the tank is about 50 and 60% for domestic wastewater and black water, respectively. The required period for sludge wasting depends on the influent COD concentration and the HRT, while characteristics of the wasted sludge are affected by operational temperature followed by the influent COD concentration and the HRT. Sludge production from the tank ranges between 0.19 to 0.22 and 0.13 to 0.15 L/(person.d), for the domestic wastewater and black water, respectively.


2020 ◽  
Vol 6 (1) ◽  
pp. 10-19
Author(s):  
Aviandini Galih Hanuranti ◽  
Sulistiya Nengse ◽  
Arqowi Pribadi ◽  
Dyah Ratri Nurmaningsih ◽  
Teguh Taruna Utama

Central Processing Plant (CPP) Gundih merupakan salah satu fasilitas produksi pengolahan gas alam Blok Gundih PT. Pertamina EP Asset 4 Cepu Field dari strukrur Kedungtuban, Randublatung, dan Kedunglusi. Kegiatan utama CPP Gundih terdiri dari kegiatan produksi dan kegiatan operasional. Kegiatan produksi menghasilkan air limbah berupa air terproduksi. Pengolahan air terproduksi terintegrasi dengan sistem dan proses produksi. Sedangkan kegiatan operasional menghasilkan air limbah yang berasal dari kegiatan domestik (perkantoran) oleh 161 pekerja/hari. Kuantitas air limbah domestik 21,896 m3/hari dengan kualitas Biological Oxygen Demand (BOD), Chemical Oxygen Demand (COD), dan Total Suspended Solid (TSS) adalah 9,8 mg/L, 100 mg/L, dan 33 mg/L. Air limbah domestik berupa grey water dan black water saat ini ditampung dalam tangki septik. Air limpasan dari tangki septik dialirkan melalui saluran drainase tanpa pengolahan. Perlu direncanakan Instalasi Pengolahan Air Limbah (IPAL) domestik yang tepat yaitu menggunakan unit biofilter anaerob-aerob. Biaya yang dibutuhan untuk pembangunan IPAL domestik ini adalah Rp. 13.590.441,80-.


2021 ◽  
Vol 11 (11) ◽  
pp. 5281
Author(s):  
Marcin Spychała ◽  
Tadeusz Nawrot ◽  
Radosław Matz

The aim of the study was to verify two morphological forms (“angel hair” and “scraps”) of xylit as a trickling filter material. The study was carried out on two types of polluted media: septic tank effluent (STE) and seminatural greywater (GW). The basic wastewater quality indicators, namely, chemical oxygen demand (COD), biochemical oxygen demand (BOD5), total suspended solids (TSS), ammonium nitrogen (NNH4), and total phosphorus (Ptot) were used as the indicators of treatment efficiency. Filtering columns filled with the investigated material acted as conventional trickling filters at a hydraulic load of 376–472 cm3/d during the preliminary stage, 198–245 cm3/d during stage I, and 184–223 cm3/d during stage II. The removal efficiency of the two morphological forms of xylit did not differ significantly. The average efficiencies of treatment were as follows: for COD, over 70, 80, and 85% for preliminary stage, stage I and stage II, respectively; for BOD5, 77–79% (preliminary stage); for TSS, 42% and 70% during the preliminary stage, and 88, 91, and 65% during stage I; for NNH4, 97–99% for stage I and 36–49% for stage II; for Ptot, 51–54% for stage I and 52–56% for stage II. The study demonstrated that xylit was a material highly effective in wastewater quality indicators removal, even during the initial period of its use.


2020 ◽  
Vol 15 (3) ◽  
pp. 70-77
Author(s):  
J.D Bala ◽  
F. A Kuta ◽  
N.U Adabara ◽  
O.P Abioye ◽  
H.S Auta ◽  
...  

Water used for washing carcasses of slaughtered animals and slaughter house is referred to as abattoir wastewater. This study was designed to investigate the microorganisms associated with abattoir wastewater and to establish the biodegradation potential of abattoir wastewater microbiota. Isolation of the microbes was carried out using pour plate technique. The total viable count for the microbes’ ranges from 2.5×104 - 4.6×105 cfu/mL. Results revealed that all the physicochemical parameters exceeded the permissible limits (total dissolved solid (TDS) 1748mg/L, total suspended solid (TSS) 176mg/L, biochemical oxygen demand (BOD5) 91 mg/L and chemical oxygen demand (COD) 227 mg/L). Microorganisms isolated include Staphylococcus aureus, Pseudomonas aeruginosa, Bacillus subtilis, Bacillus anthracis, Aspergillus niger, A. flavus, Mucor sp, Trichophyton quickeanum and Penicillium sp. Some of the microbes were observed to have biodegradation potential by their ability to grow on mineral salt media (MSM) incorporated with starch, cellulose, crude oil, kerosene and diesel as the sole source of carbon and energy. This study suggests that abattoir wastewater harbors microorganisms that could be hazardous to public health when discharged into the environment untreated hence the need for strict monitoring. These microbes isolated could be employed as agent of bioremediation of wastewaters. Key words: Abattoir; Biodegredation; Isolation; Microbiota; Wastewater


2004 ◽  
Vol 49 (5-6) ◽  
pp. 281-288 ◽  
Author(s):  
S.J. Kim ◽  
P.Y. Yang

A two-stage entrapped mixed microbial cell (2SEMMC) process which separates nitrification and denitrification phases by the installation of the anoxic and oxic EMMC reactors packed with EMMC carriers was operated with 6, 4, 3, and 2 hours of hydraulic retention time (HRT) using simulated domestic wastewater. The activated sludge was immobilized using cellulose acetate for the EMMC carriers. Similar soluble chemical oxygen demand (SCOD) removal efficiencies of 90-97% were observed for all HRTs (SCOD loading rate of 0.84-2.30 g/L/d) applied. In order to achieve more than 80 % of TN removal efficiency, the HRT should be maintained higher than 4 hours (less than 0.24 g/L/d of TN loading rate). Denitrification was a rate-limiting step which controlled overall TN removal efficiency at TN loading rate of 0.15-0.31 g/L/d although nitrification efficiencies achieved 97-99 %. The effluent TSS of less than 25 mg/L in the 2SEMMC process was maintained at the SCOD loading rate of less than 1.23 g/L/d with back-washing intervals of 5 and 10 days in the anoxic and oxic EMMC reactors, respectively. The minimum HRT of 4 hours is required for high removal efficiencies of organics (average 95.6 %) and nitrogen (average 80.5 %) in the 2SEMMC process with 3 times of recirculation ratio.


Sign in / Sign up

Export Citation Format

Share Document