scholarly journals An Overview of Wearable Piezoresistive and Inertial Sensors for Respiration Rate Monitoring

Electronics ◽  
2021 ◽  
Vol 10 (17) ◽  
pp. 2178
Author(s):  
Roberto De Fazio ◽  
Marco Stabile ◽  
Massimo De Vittorio ◽  
Ramiro Velázquez ◽  
Paolo Visconti

The demand for wearable devices to measure respiratory activity is constantly growing, finding applications in a wide range of scenarios (e.g., clinical environments and workplaces, outdoors for monitoring sports activities, etc.). Particularly, the respiration rate (RR) is a vital parameter since it indicates serious illness (e.g., pneumonia, emphysema, pulmonary embolism, etc.). Therefore, several solutions have been presented in the scientific literature and on the market to make RR monitoring simple, accurate, reliable and noninvasive. Among the different transduction methods, the piezoresistive and inertial ones satisfactorily meet the requirements for smart wearable devices since unobtrusive, lightweight and easy to integrate. Hence, this review paper focuses on innovative wearable devices, detection strategies and algorithms that exploit piezoresistive or inertial sensors to monitor the breathing parameters. At first, this paper presents a comprehensive overview of innovative piezoresistive wearable devices for measuring user’s respiratory variables. Later, a survey of novel piezoresistive textiles to develop wearable devices for detecting breathing movements is reported. Afterwards, the state-of-art about wearable devices to monitor the respiratory parameters, based on inertial sensors (i.e., accelerometers and gyroscopes), is presented for detecting dysfunctions or pathologies in a non-invasive and accurate way. In this field, several processing tools are employed to extract the respiratory parameters from inertial data; therefore, an overview of algorithms and methods to determine the respiratory rate from acceleration data is provided. Finally, comparative analysis for all the covered topics are reported, providing useful insights to develop the next generation of wearable sensors for monitoring respiratory parameters.

2021 ◽  
Vol 11 (3) ◽  
pp. 1235
Author(s):  
Su Min Yun ◽  
Moohyun Kim ◽  
Yong Won Kwon ◽  
Hyobeom Kim ◽  
Mi Jung Kim ◽  
...  

The development of wearable sensors is aimed at enabling continuous real-time health monitoring, which leads to timely and precise diagnosis anytime and anywhere. Unlike conventional wearable sensors that are somewhat bulky, rigid, and planar, research for next-generation wearable sensors has been focused on establishing fully-wearable systems. To attain such excellent wearability while providing accurate and reliable measurements, fabrication strategies should include (1) proper choices of materials and structural designs, (2) constructing efficient wireless power and data transmission systems, and (3) developing highly-integrated sensing systems. Herein, we discuss recent advances in wearable devices for non-invasive sensing, with focuses on materials design, nano/microfabrication, sensors, wireless technologies, and the integration of those.


Author(s):  
Enrique Garcia-Ceja ◽  
Ramon F. Brena

Recently, Human Activity Recognition (HAR) has become an important research area because of its wide range of applications in several domains such as health care, elder care, sports monitoring systems, etc. The use of wearable sensors — specifically the use of inertial sensors such as accelerometers and gyroscopes — has become the most common approach to recognize physical activities because of their unobtrusiveness and ubiquity. Overall, the process of building a HAR system starts with a feature extraction phase and then a classification model is trained. In the work of Siirtola et al. is proposed an intermediate clustering step to find the homogeneous groups of activities. For the recognition step, an instance is assigned to one of the groups and the final classification is performed inside that group. In this work we evaluate the clustering-based approach for activity classification proposed by Siirtola with two additional improvements: automatic selection of the number of groups and an instance reassignment procedure. In the original work, they evaluated their method using decision trees on a sports activities dataset. For our experiments, we evaluated seven different classification models on four public activity recognition datasets. Our results with 10-fold Cross Validation showed that the method proposed by Siirtola with our additional two improvements performed better in the majority of cases as compared to using the single classification model under consideration. When using Leave One User Out Cross Validation (user independent model) we found no differences between the proposed method and the single classification model.


Molecules ◽  
2021 ◽  
Vol 26 (3) ◽  
pp. 748
Author(s):  
Atul Sharma ◽  
Mihaela Badea ◽  
Swapnil Tiwari ◽  
Jean Louis Marty

With the increasing prevalence of growing population, aging and chronic diseases continuously rising healthcare costs, the healthcare system is undergoing a vital transformation from the traditional hospital-centered system to an individual-centered system. Since the 20th century, wearable sensors are becoming widespread in healthcare and biomedical monitoring systems, empowering continuous measurement of critical biomarkers for monitoring of the diseased condition and health, medical diagnostics and evaluation in biological fluids like saliva, blood, and sweat. Over the past few decades, the developments have been focused on electrochemical and optical biosensors, along with advances with the non-invasive monitoring of biomarkers, bacteria and hormones, etc. Wearable devices have evolved gradually with a mix of multiplexed biosensing, microfluidic sampling and transport systems integrated with flexible materials and body attachments for improved wearability and simplicity. These wearables hold promise and are capable of a higher understanding of the correlations between analyte concentrations within the blood or non-invasive biofluids and feedback to the patient, which is significantly important in timely diagnosis, treatment, and control of medical conditions. However, cohort validation studies and performance evaluation of wearable biosensors are needed to underpin their clinical acceptance. In the present review, we discuss the importance, features, types of wearables, challenges and applications of wearable devices for biological fluids for the prevention of diseased conditions and real-time monitoring of human health. Herein, we summarize the various wearable devices that are developed for healthcare monitoring and their future potential has been discussed in detail.


2016 ◽  
Vol 1 (1) ◽  
pp. 4
Author(s):  
Marymol Koshy ◽  
Bushra Johari ◽  
Mohd Farhan Hamdan ◽  
Mohammad Hanafiah

Hypertrophic cardiomyopathy (HCM) is a global disease affecting people of various ethnic origins and both genders. HCM is a genetic disorder with a wide range of symptoms, including the catastrophic presentation of sudden cardiac death. Proper diagnosis and treatment of this disorder can relieve symptoms and prolong life. Non-invasive imaging is essential in diagnosing HCM. We present a review to deliberate the potential use of cardiac magnetic resonance (CMR) imaging in HCM assessment and also identify the risk factors entailed with risk stratification of HCM based on Magnetic Resonance Imaging (MRI).


Sensors ◽  
2021 ◽  
Vol 21 (15) ◽  
pp. 5242
Author(s):  
Jolene Ziyuan Lim ◽  
Alexiaa Sim ◽  
Pui Wah Kong

The aim of this review is to investigate the common wearable devices currently used in field hockey competitions, and to understand the hockey-specific parameters these devices measure. A systematic search was conducted by using three electronic databases and search terms that included field hockey, wearables, accelerometers, inertial sensors, global positioning system (GPS), heart rate monitors, load, performance analysis, player activity profiles, and competitions from the earliest record. The review included 39 studies that used wearable devices during competitions. GPS units were found to be the most common wearable in elite field hockey competitions, followed by heart rate monitors. Wearables in field hockey are mostly used to measure player activity profiles and physiological demands. Inconsistencies in sampling rates and performance bands make comparisons between studies challenging. Nonetheless, this review demonstrated that wearable devices are being used for various applications in field hockey. Researchers, engineers, coaches, and sport scientists can consider using GPS units of higher sampling rates, as well as including additional variables such as skin temperatures and injury associations, to provide a more thorough evaluation of players’ physical and physiological performances. Future work should include goalkeepers and non-elite players who are less studied in the current literature.


2021 ◽  
Vol 24 (3) ◽  
pp. 30-34
Author(s):  
Rishi Shukla ◽  
Neev Kiran ◽  
Rui Wang ◽  
Jeremy Gummeson ◽  
Sunghoon Ivan Lee

Over the past few decades, we have witnessed tremendous advancements in semiconductor and MEMS technologies, leading to the proliferation of ultra-miniaturized and ultra-low-power (in micro-watt ranges) wearable devices for wellness and healthcare [1]. Most of these wearable sensors are battery powered for their operation. The use of an on-device battery as the primary energy source poses a number of challenges that serve as the key barrier to the development of novel wearable applications and the widespread use of numerous, seamless wearable sensors [5].


Mindfulness ◽  
2021 ◽  
Author(s):  
Karin Matko ◽  
Ulrich Ott ◽  
Peter Sedlmeier

Abstract Objectives Meditation is an umbrella term for a vast range of contemplative practices. Former proposals have struggled to do justice to this variety. To our knowledge, there is to date no comprehensive overview of meditation techniques spanning all major traditions. The present studies aimed at providing such a comprehensive list of meditation techniques. Methods In a qualitative study, we compiled a collection of 309 meditation techniques through a literature search and interviews with 20 expert meditators. Then, we reduced this collection to 50 basic meditation techniques. In a second, quantitative study, 635 experienced meditators from a wide range of meditative backgrounds indicated how much experience they had with each of these 50 meditation techniques. Results Meditators’ responses indicated that our choice of techniques had been adequate and only two techniques had to be added. Our additional statistical and cluster analyses illustrated preferences for specific techniques across and within diverse traditions as well as sets of techniques commonly practiced together. Body-centered techniques stood out in being of exceptional importance to all meditators. Conclusions In conclusion, we found an amazing variety of meditation techniques, which considerably surpasses previous collections. Our selection of basic meditation techniques might be of value for future scientific investigations and we encourage researchers to use this set.


Nanomaterials ◽  
2021 ◽  
Vol 11 (3) ◽  
pp. 822
Author(s):  
Christine Thanner ◽  
Martin Eibelhuber

Ultraviolet (UV) Nanoimprint Lithography (NIL) is a replication method that is well known for its capability to address a wide range of pattern sizes and shapes. It has proven to be an efficient production method for patterning resist layers with features ranging from a few hundred micrometers and down to the nanometer range. Best results can be achieved if the fundamental behavior of the imprint resist and the pattern filling are considered by the equipment and process parameters. In particular, the material properties and pattern size and shape play a crucial role. For capillary force-driven filling behavior it is important to understand the influencing parameters and respective failure modes in order to optimize the processes for reliable full wafer manufacturing. In this work, the nanoimprint results obtained for different pattern geometries are compared with respect to pattern quality and residual layer thickness: The comprehensive overview of the relevant process parameters is helpful for setting up NIL processes for different nanostructures with minimum layer thickness.


Hand ◽  
2021 ◽  
pp. 155894472110146
Author(s):  
Francisco R. Avila ◽  
Rickey E. Carter ◽  
Christopher J. McLeod ◽  
Charles J. Bruce ◽  
Davide Giardi ◽  
...  

Background Wearable devices and sensor technology provide objective, unbiased range of motion measurements that help health care professionals overcome the hindrances of protractor-based goniometry. This review aims to analyze the accuracy of existing wearable sensor technologies for hand range of motion measurement and identify the most accurate one. Methods We performed a systematic review by searching PubMed, CINAHL, and Embase for studies evaluating wearable sensor technology in hand range of motion assessment. Keywords used for the inquiry were related to wearable devices and hand goniometry. Results Of the 71 studies, 11 met the inclusion criteria. Ten studies evaluated gloves and 1 evaluated a wristband. The most common types of sensors used were bend sensors, followed by inertial sensors, Hall effect sensors, and magnetometers. Most studies compared wearable devices with manual goniometry, achieving optimal accuracy. Although most of the devices reached adequate levels of measurement error, accuracy evaluation in the reviewed studies might be subject to bias owing to the use of poorly reliable measurement techniques for comparison of the devices. Conclusion Gloves using inertial sensors were the most accurate. Future studies should use different comparison techniques, such as infrared camera–based goniometry or virtual motion tracking, to evaluate the performance of wearable devices.


Gerontology ◽  
2021 ◽  
pp. 1-10
Author(s):  
Chenzhen Du ◽  
Hongyan Wang ◽  
Heming Chen ◽  
Xiaoyun Fan ◽  
Dongliang Liu ◽  
...  

Aims: Using specials wearable sensors, we explored changes in gait and balance parameters, over time, in elderly patients at high risk of diabetic foot, wearing different types of footwear. This assessed the relationship between gait and balance changes in elderly diabetic patients and the development of foot ulcers, in a bid to uncover potential benefits of wearable devices in the prognosis and management of the aforementioned complication. Methods: A wearable sensor-based monitoring system was used in middle-elderly patients with diabetes who recently recovered from neuropathic plantar foot ulcers. A total of 6 patients (age range: 55–80 years) were divided into 2 groups: the therapeutic footwear group (n = 3) and the regular footwear (n = 3) group. All subjects were assessed for gait and balance throughout the study period. Walking ability and gait pattern were assessed by allowing participants to walk normally for 1 min at habitual speed. The balance assessment program incorporated the “feet together” standing test and the instrumented modified Clinical Test of Sensory Integration and Balance. Biomechanical information was monitored at least 3 times. Results: We found significant differences in stride length (p < 0.0001), stride velocity (p < 0.0001), and double support (p < 0.0001) between the offloading footwear group (OG) and the regular footwear group on a group × time interaction. The balance test embracing eyes-open condition revealed a significant difference in Hip Sway (p = 0.004), COM Range ML (p = 0.008), and COM Position (p = 0.004) between the 2 groups. Longitudinally, the offloading group exhibited slight improvement in the performance of gait parameters over time. The stride length (odds ratio 3.54, 95% CI 1.34–9.34, p = 0.018) and velocity (odds ratio 3.13, 95% CI 1.19–8.19, p = 0.033) of OG patients increased, converse to the double-support period (odds ratio 6.20, 95% CI 1.97–19.55, p = 0.002), which decreased. Conclusions: Special wearable devices can accurately monitor gait and balance parameters in patients in real time. The finding reveals the feasibility and effectiveness of advanced wearable sensors in the prevention and management of diabetic foot ulcer and provides a solid background for future research. In addition, the development of foot ulcers in elderly diabetic patients may be associated with changes in gait parameters and the nature of footwear. Even so, larger follow-up studies are needed to validate our findings.


Sign in / Sign up