scholarly journals Optimal and Decentralized Control Strategies for Inverter-Based AC Microgrids

Energies ◽  
2019 ◽  
Vol 12 (18) ◽  
pp. 3529 ◽  
Author(s):  
Michael D. Cook ◽  
Eddy H. Trinklein ◽  
Gordon G. Parker ◽  
Rush D. Robinett ◽  
Wayne W. Weaver

This paper presents two control strategies: (i) An optimal exergy destruction (OXD) controller and (ii) a decentralized power apportionment (DPA) controller. The OXD controller is an analytical, closed-loop optimal feedforward controller developed utilizing exergy analysis to minimize exergy destruction in an AC inverter microgrid. The OXD controller requires a star or fully connected topology, whereas the DPA operates with no communication among the inverters. The DPA presents a viable alternative to conventional P − ω / Q − V droop control, and does not suffer from fluctuations in bus frequency or steady-state voltage while taking advantage of distributed storage assets necessary for the high penetration of renewable sources. The performances of OXD-, DPA-, and P − ω / Q − V droop-controlled microgrids are compared by simulation.

1993 ◽  
Vol 28 (11-12) ◽  
pp. 531-538 ◽  
Author(s):  
B. Teichgräber

A nitrification/denitrification process was applied to reject water treatment from sludge dewatering at Bottrop central sludge treatment facilities of the Emschergenossenschaft. On-line monitoring of influent and effluent turbidity, closed loop control of DO and pH, and on-line monitoring of nitrogen compounds were combined to a three level control pattern. Though on-line measurement of substrate and product showed substantial response time it could be used to operate nitrification/denitrification within process boundaries.


Energies ◽  
2021 ◽  
Vol 14 (12) ◽  
pp. 3511
Author(s):  
Ali Khalid Shaker Al-Sayyab ◽  
Joaquín Navarro-Esbrí ◽  
Victor Manuel Soto-Francés ◽  
Adrián Mota-Babiloni

This work focused on a compound PV/T waste heat driven ejector-heat pump system for simultaneous data centre cooling and waste heat recovery for district heating. The system uses PV/T waste heat as the generator’s heat source, acting with the vapour generated in an evaporative condenser as the ejector drive force. Conventional and advanced exergy and advanced exergoeconomic analyses are used to determine the cause and avoidable degree of the components’ exergy destruction rate and cost rates. Regarding the conventional exergy analysis for the whole system, the compressor represents the largest exergy destruction source of 26%. On the other hand, the generator shows the lowest sources (2%). The advanced exergy analysis indicates that 59.4% of the whole system thermodynamical inefficiencies can be avoided by further design optimisation. The compressor has the highest contribution to the destruction in the avoidable exergy destruction rate (21%), followed by the ejector (18%) and condenser (8%). Moreover, the advanced exergoeconomic results prove that 51% of the system costs are unavoidable. In system components cost comparison, the highest cost comes from the condenser, 30%. In the same context, the ejector has the lowest exergoeconomic factor, and it should be getting more attention to reduce the irreversibility by design improving. On the contrary, the evaporator has the highest exergoeconomic factor (94%).


Author(s):  
Andrea Mammoli ◽  
C. Birk Jones ◽  
Hans Barsun ◽  
David Dreisigmeyer ◽  
Gary Goddard ◽  
...  

2016 ◽  
Vol 10 ◽  
Author(s):  
James Wright ◽  
Vaughan G. Macefield ◽  
André van Schaik ◽  
Jonathan C. Tapson

2014 ◽  
Vol 551 ◽  
pp. 337-343
Author(s):  
Hui Chen ◽  
Yong Ling Fu ◽  
Juan Chen ◽  
He Song Liu

With the development of the advanced precision-guided missile and anti-missile system, high precision, high penetration ability and Low energy consumption have become an important direction for the missile. A new missile electro-hydraulic actuation system with dual independent closed-loop is put forward with the trend of high performance and energy-saving, and then the operating principle and process are discussed. Finally the accurate mathematical model is established, and the influence of the different basic pressure on the dynamic performance is analyzed. The simulation results show that the new proposed scheme has made great improvements in reducing the zero-control current of the system, but the efficiency and performance of the actuation system should be considered integrated due to the decrease of the dynamic performance, so it is practical for the future development of the missile electro-hydraulic actuation system.


2021 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Vikash Gurugubelli ◽  
Arnab Ghosh

Purpose The share of renewable energy sources (RESs) in the power system is increasing day by day. The RESs are intermittent, therefore maintaining the grid stability and power balance is very difficult. The purpose of this paper is to control the inverters in microgrid using different control strategies to maintain the system stability and power balance. Design/methodology/approach In this paper, different control strategies are implemented to the voltage source converter (VSC) to get the desired performance. The DQ control is a basic control strategy that is inherently present in the droop and virtual synchronous machine (VSM) control strategies. The droop and VSM control strategies are inspired by the conventional synchronous machine (SM). The main objective of this work is to design and implement the three aforementioned control strategies in microgrid. Findings The significant contributions of this work are: the detailed implementation of DQ control, droop control and VSM control strategies for VSC in both grid-connected mode and standalone mode is presented; the MATLAB/Simulink simulation results and comparative studies of the three aforementioned controllers are introduced first time in the proposed work; and the opal-RT digital real-time simulation results of the proposed VSM control show the superiority in transient response compared to the droop control strategy. Research limitations/implications In the power system, the power electronic-based power allowed by VSM is dominated by the conventional power which is generated from the traditional SM, and then the issues related to stability still need advance study. There are some differences between the SM and VSM characteristics, so the integration of VSM with the existing system still needs further study. Economical operation of VSM with hybrid storage is also one of the future scopes of this work. Originality/value The significant contributions of this work are: the detailed implementation of DQ control, droop control and VSM control strategies for VSC in both grid-connected mode and standalone mode is presented; the MATLAB/Simulink simulation results and comparative studies of the three aforementioned controllers are introduced first time in the proposed work; and the opal-RT digital real-time simulation results of the proposed VSM control show the superiority in transient response compared to the droop control strategy.


2018 ◽  
Vol 32 (34n36) ◽  
pp. 1840098
Author(s):  
Yuan Li ◽  
Huifang Shen ◽  
Chao Xiong ◽  
Yaofei Han ◽  
Guofeng He

In order to eliminate the effect on the grid current caused by the background harmonic voltage and the reference signal on the grid connected multi-inverter, this paper adopts the double closed-loop feed-forward control strategy. This strategy is based on the inductor voltage and the grid-connected current, and the integrated control strategy of quasi-proportional resonance loop parallel to a specific harmonic compensation loop. Based on the closed-loop model of multiple inverters, the change curves of the transfer function of the two control strategies are compared with the feed-forward control and the composite proportional resonance. The two corresponding control methods are used to analyze the current quality of the multi-inverter impact. Finally, the MATLAB/Simulink simulation model is set up to verify the proposed control strategies. The simulation results show that the proposed method can achieve better tracking of the sinusoidal command signal at the fundamental frequency, and enhance the anti-interference ability of the system at the 3rd, 5th, and 7th harmonic frequency.


Author(s):  
Avdhesh Kr. Sharma ◽  
Raj Kumar Singh

This article describes the energy and exergy analysis of the reduction zone in a downdraft biomass gasifier. A simplistic formulation for describing the pyrolysis and oxidation of these products has been presented for initialization. Equilibrium and kinetic models are used to predict the reduction products leaving the reduction zone and thus the 1st law efficiency. In the reduction zone, exergy destruction due to chemical, physical, compositional, internal heat transfer and heat loss to the surrounding has been quantified to describe 2nd law efficiency. The comparison of equilibrium and kinetic models is carried out with experimental data for general validity. Parametric analysis of char bed length and inflow temperature on gas composition, un-converted char, exergy destruction, 1st law and the 2nd law efficiency has also been carried out. Simulation results identified a critical char bed length (where all char gets consumed) for a given feedstock, which depends on residence time and reaction temperature in the reduction zone. Near critical char bed length, predictions show high calorific value of gas with relatively less exergy destruction and thus optimum reactor performance. The accuracy of the prediction depends on the validity of initial input conditions.


2015 ◽  
Vol 2015 ◽  
pp. 1-22 ◽  
Author(s):  
Mashitah Che Razali ◽  
Norhaliza Abdul Wahab ◽  
P. Balaguer ◽  
M. F. Rahmat ◽  
Sharatul Izah Samsudin

Proportional integral derivative (PID) controllers are commonly used in process industries due to their simple structure and high reliability. Efficient tuning is one of the relevant issues of PID controller type. The tuning process always becomes a challenging matter especially for multivariable system and to obtain the best control tuning for different time scales system. This motivates the use of singularly perturbation method into the multivariable PID (MPID) controller designs. In this work, wastewater treatment plant and Newell and Lee evaporator were considered as system case studies. Four MPID control strategies, Davison, Penttinen-Koivo, Maciejowski, and Combined methods, were applied into the systems. The singularly perturbation method based on Naidu and Jian Niu algorithms was applied into MPID control design. It was found that the singularly perturbed system obtained by Naidu method was able to maintain the system characteristic and hence was applied into the design of MPID controllers. The closed loop performance and process interactions were analyzed. It is observed that less computation time is required for singularly perturbed MPID controller compared to the conventional MPID controller. The closed loop performance shows good transient responses, low steady state error, and less process interaction when using singularly perturbed MPID controller.


Sign in / Sign up

Export Citation Format

Share Document