scholarly journals Energy Intensity Reduction in Large-Scale Non-Residential Buildings by Dynamic Control of HVAC with Heat Pumps

Energies ◽  
2021 ◽  
Vol 14 (13) ◽  
pp. 3878
Author(s):  
Alessandro Franco ◽  
Lorenzo Miserocchi ◽  
Daniele Testi

One of the main elements for increasing energy efficiency in large-scale buildings is identified in the correct management and control of the Heating Ventilation and Air Conditioning (HVAC) systems, particularly those with Heat Pumps (HPs). The present study aimed to evaluate the perspective of energy savings achievable with the implementation of an optimal control of the HVAC with HPs. The proposed measures involve the use of a variable air volume system, demand-controlled ventilation, an energy-aware control of the heat recovery equipment, and an improved control of the heat pump and chiller supply water temperature. The analysis has been applied to an academic building located in Pisa and is carried out by means of dynamic simulation. The achieved energy saving can approach values of more than 80% if compared with actual plants based on fossil fuel technologies. A major part of this energy saving is linked to the use of heat pumps as thermal generators as well as to the implementation of an energy efficient ventilation, emphasizing the importance of such straightforward measures in reducing the energy intensity of large-scale buildings.

Energies ◽  
2021 ◽  
Vol 14 (17) ◽  
pp. 5541
Author(s):  
Alessandro Franco ◽  
Lorenzo Miserocchi ◽  
Daniele Testi

The paper analyzes and compares the perspectives for reducing the energy consumption associated to the operation of Heating Ventilation and Air Conditioning system for climatic control of large-size non-residential buildings. Three different control strategies are considered comparing the use of boiler and heat pumps as heating systems and analyzing the use of demand-controlled ventilation, operating on the effective occupancy of the building. The control strategies are applied to two different educational buildings with shapes representative of typical educational structures. The results of the analysis show how the energy consumption can be reduced up to 70%, shifting from the actual values of the energy intensity of over 300 kWh/m2 for year to values of less than 100 kWh/m2 per year. The significance of the energy savings achieved in such different buildings has led to the identification of a possible benchmark for HVAC systems in the next future years which could help reach the environmental targets in this sector.


Author(s):  
John A. Stankovic ◽  
Tian He

This paper presents a holistic view of energy management in sensor networks. We first discuss hardware designs that support the life cycle of energy, namely: (i) energy harvesting, (ii) energy storage and (iii) energy consumption and control. Then, we discuss individual software designs that manage energy consumption in sensor networks. These energy-aware designs include media access control, routing, localization and time-synchronization. At the end of this paper, we present a case study of the VigilNet system to explain how to integrate various types of energy management techniques to achieve collaborative energy savings in a large-scale deployed military surveillance system.


Author(s):  
Jerzy Sowa ◽  
Maciej Mijakowski

A humidity-sensitive demand-controlled ventilation system is known for many years. It has been developed and commonly applied in regions with an oceanic climate. Some attempts were made to introduce this solution in Poland in a much severe continental climate. The article evaluates this system's performance and energy consumption applied in an 8-floor multi-unit residential building, virtual reference building described by the National Energy Conservation Agency NAPE, Poland. The simulations using the computer program CONTAM were performed for the whole hating season for Warsaw's climate. Besides passive stack ventilation that worked as a reference, two versions of humidity-sensitive demand-controlled ventilation were checked. The difference between them lies in applying the additional roof fans that convert the system to hybrid. The study confirmed that the application of demand-controlled ventilation in multi-unit residential buildings in a continental climate with warm summer (Dfb) leads to significant energy savings. However, the efforts to ensure acceptable indoor air quality require hybrid ventilation, which reduces the energy benefits. It is especially visible when primary energy use is analyzed.


2021 ◽  
Author(s):  
Christopher L. K. Wang

As sleep is unconscious, the traditional definition of thermal comfort with conscious judgment does not apply. In this thesis sleep thermal comfort is defined as the thermal condition which enables sleep to most efficiently rejuvenate the body and mind. A comfort model was developed to stimulate the respective thermal environment required to achieve the desired body thermal conditions and a new infrared sphere method was developed to measure mean radiant temperature. Existing heating conditions according to building code conditions during sleeping hours was calculated to likely overheat a sleeping person and allowed energy saving potential by reducing nighttime heating set points. Experimenting with existing radiantly and forced air heated residential buildings, it was confirmed that thermal environment was too hot for comfortable sleep and that the infrared sphere method shows promise. With the site data, potential energy savings were calculated and around 10% of energy consumption reduction may be achieved during peak heating.


2018 ◽  
Vol 164 ◽  
pp. 01007
Author(s):  
Dany Perwita Sari ◽  
Yun-shang Chiou

There are some architectural factors in the energy saving design of residential houses in Taiwan. In addition, in rural area, window glazing is a key factor to reducing electricity. For these purposes, a simulation model of exterior shading has been done in this study. Various types of shading devices have been analysed and compared in terms of energy savings. Simulation analysis by DesignBuilder reveals that shading devices has substantial impact to minimizing energy consumption. The results derived in this paper could provide useful suggestions for the shading design of residential buildings at rural area in Taiwan.


2016 ◽  
Vol 41 (1) ◽  
pp. 88-92
Author(s):  
Rong-Yue Zheng ◽  
Jian Yao

A large number of residential buildings in hot summer and cold winter zone of China are non-energy efficient with poor indoor thermal conditions. Retrofitting residential buildings with energy efficiency measures is thus important for residents. However, this work progressed slowly because practically applicable measures that not only have high energy savings but also improve indoor thermal performance have not been studied. Thus, this paper carried out a simulation study on the selection of suitable energy saving measures for residential buildings in hot summer and cold winter zone of China. Five potential energy saving options are considered and the energy, indoor thermal comfort and economic performance are compared. The results show that adding movable solar shades is the optimum option with all performance indices ranking first. Meanwhile, this measure is also the only acceptable energy saving solution for residents since its payback period is less than the lifespan of a building. As a conclusion, it is recommended to use movable solar shades as a first priority when retrofitting residential buildings.


2020 ◽  
Vol 10 (12) ◽  
pp. 4336
Author(s):  
Yue Hu ◽  
Per Kvols Heiselberg ◽  
Tine Steen Larsen

A ventilated window system enhanced by phase change material (PCM) has been developed, and its energy-saving potential examined in previous works. In this paper, the ventilation control strategies are further developed, to improve the energy-saving potential of the PCM energy storage. The influence of ventilation airflow rate on the energy-saving potential of the PCM storage is firstly studied based on an EnergyPlus model of a sustainable low energy house located in New York. It shows that in summer, the optimized ventilation airflow rate is 300 m3/h. The energy-saving of utilizing a ventilated window with PCM energy storage is 10.1% compared to using a stand-alone ventilated window, and 12.0% compared to using a standard window. In winter, the optimized ventilation airflow rate is 102 m3/h. The energy-saving of utilizing a ventilated window with PCM energy storage is 26.6% compared to using a stand-alone ventilated window, and 32.8% compared to using a standard window. Based on the optimized ventilation airflow rate, a demand control ventilation strategy, which personalizes the air supply and heat pump setting based on the demand of each room, is proposed and its energy-saving potential examined. The results show that the energy savings of using demand control compared to a constant ventilation airflow rate in the house is 14.7% in summer and 30.4% in winter.


2019 ◽  
Vol 10 (1) ◽  
Author(s):  
Jingxin Gao ◽  
Xiaoyang Zhong ◽  
Weiguang Cai ◽  
Hong Ren ◽  
Tengfei Huo ◽  
...  

Abstract Urban residential buildings make large contributions to energy consumption. Energy consumption per square meter is most widely used to measure energy efficiency in urban residential buildings. This study aims to explore whether it is an appropriate indicator. An extended STIRPAT model was used based on the survey data from 867 households. Here we present that building area per household has a dilution effect on energy consumption per square meter. Neglecting this dilution effect leads to a significant overestimation of the effectiveness of building energy savings standards. Further analysis suggests that the peak of energy consumption per square meter in China’s urban residential buildings occurred in 2012 when accounting for the dilution effect, which is 11 years later than it would have occurred without considering the dilution effect. Overall, overlooking the dilution effect may lead to misleading judgments of crucial energy-saving policy tools, as well as the ongoing trend of residential energy consumption in China.


Energies ◽  
2020 ◽  
Vol 13 (24) ◽  
pp. 6669
Author(s):  
Jerzy Sowa ◽  
Maciej Mijakowski

Humidity-sensitive, demand-controlled ventilation systems have been in use for many years in regions with oceanic climates. Some attempts have been made to apply this technology in Poland, which has a continental climate. This article evaluates the performance and energy consumption of such a system when applied in an eight-floor, multiunit, residential building, i.e., the virtual reference building described by the National Energy Conservation Agency (NAPE), Poland. Simulations using the computer program CONTAM were performed for the whole heating season based upon the climate in Warsaw. Besides passive stack ventilation, that served as a reference, two ventilation systems were studied: one standard and one “hybrid” system with additional roof fans. This study confirmed that the application of humidity-sensitive, demand-controlled ventilation in multiunit residential buildings in a continental climate (Dfb) led to significant energy savings (up to 11.64 kWh/m2 of primary energy). However, the operation of the system on higher floors was found to be ineffective. Ensuring consistent operation of the system on all floors required supplementary fans. The introduction of a hybrid mode reduced carbon dioxide concentrations by approximately 32% in the units located in the upper part of the building. The energetic effect in such cases depends strongly on the electricity source. In the case of the national energy grid, savings of primary energy would be relatively low, i.e., 1.07 kWh/m2, but in the case of locally produced renewable energy, the energy savings would be equal to 5.18 kWh/m2.