scholarly journals Performance Test of QU-Fitting

Galaxies ◽  
2019 ◽  
Vol 7 (3) ◽  
pp. 69
Author(s):  
Yoshimitsu Miyashita

QU-fitting is a model-fit method to reproduce the model of the Faraday Dispersion Function (FDF or Faraday spectrum), which is a probability distribution function of polarized intensity in Faraday depth space. In order to find the best-fit parameters of the model FDF, we adopt the Markov Chain Monte Carlo (MCMC) algorithm using Geweke’s convergence diagnostics. Akaike and Bayesian Information Criteria (AIC and BIC, respectively) are used to select the best model from several FDF fitting models. In this paper, we investigate the performance of the standard QU-fitting algorithm quantitatively by simulating spectro-polarimetric observations of two Faraday complex sources located along the same Line Of Sight (LOS), varying the gap between two sources in Faraday depth space and their widths, systematically. We fix the frequency bandwidth in 700–1800 MHz and make mock polarized spectra with a high Signal-to-Noise ratio (S/N). We prepare four FDF models for the fitting by changing the number of model parameters and test the correctness of MCMC and AIC/BIC. We find that the combination of MCMC and AIC/BIC works well for parameter estimation and model selection in the cases where the sources have widths smaller than 1/4 Full Width at Half Maximum (FWHM) and a gap larger than one FWHM in Faraday depth space. We note that when two sources have a gap of five FWHM in Faraday depth space, MCMC tends to be trapped in a local maximum likelihood compared to other situations.

2020 ◽  
Vol 501 (2) ◽  
pp. 2268-2278
Author(s):  
John K Webb ◽  
Chung-Chi Lee ◽  
Robert F Carswell ◽  
Dinko Milaković

ABSTRACT Robust model-fitting to spectroscopic transitions is a requirement across many fields of science. The corrected Akaike and Bayesian information criteria (AICc and BIC) are most frequently used to select the optimal number of fitting parameters. In general, AICc modelling is thought to overfit (too many model parameters) and BIC underfits. For spectroscopic modelling, both AICc and BIC lack in two important respects: (a) no penalty distinction is made according to line strength such that parameters of weak lines close to the detection threshold are treated with equal importance as strong lines and (b) no account is taken of the way in which a narrow spectral line impacts only on a very small section of the overall data. In this paper, we introduce a new information criterion that addresses these shortcomings, the Spectral Information Criterion (SpIC). Spectral simulations are used to compare performances. The main findings are (i) SpIC clearly outperforms AICc for high signal-to-noise data, (ii) SpIC and AICc work equally well for lower signal-to-noise data, although SpIC achieves this with fewer parameters, and (iii) BIC does not perform well (for this application) and should be avoided. The new method should be of broader applicability (beyond spectroscopy), wherever different model parameters influence separated small ranges within a larger data set and/or have widely varying sensitivities.


2021 ◽  
Vol 11 (3) ◽  
pp. 681-687
Author(s):  
Jaewon Kim ◽  
Sungsik Kang ◽  
Konsu Lee ◽  
Jin Ho Jung ◽  
Garam Kim ◽  
...  

The purpose of this study was to generate the PET images with high signal-to-noise ratio (SNR) acquired for typical scan durations (H-PET) from short scan time PET images with low SNR (L-PET) using deep learning and to evaluate the effect of scan time on the quality of predicted PET image. A convolutional neural network (CNN) with a concatenated connection and residual learning framework was implemented. PET data from 27 patients were acquired for 900 s, starting 60 minutes after the intravenous administration of FDG using a commercial PET/CT scanner. To investigate the effect of scan time on the quality of the predicted H-PETs, 10 s, 30 s, 60 s, and 120 s PET data were generated by sorting the 900 s LMF data into the LMF data acquired for each scan time. Twenty-three of the 27 patient images were used for training of the proposed CNN and the remaining four patient images were used for test of the CNN. The predicted H-PETs generated by the CNN were compared to ground-truth H-PETs, L-PETs, and filtered L-PETs processed with four commonly used denoising algorithms. The peak signal-to-noise ratios (PSNRs), normalized root mean square errors (NRMSEs), and average regionof- interest (ROI) differences as a function of scan time were calculated. The quality of the predicted H-PETs generated by the CNN was superior to that of the L-PETs and filtered L-PETs. Lower NRMSEs and higher PSNRs were also obtained from predicted H-PETs compared to the L-PETs and filtered L-PETs. ROI differences in the predicted H-PETs were smaller than those of the L-PETs. The quality of the predicted H-PETs gradually improved with increasing scan times. The lowest NRMSEs, highest PSNRs, and smallest ROI differences were obtained using the predicted H-PETs for 120 s. Various performance test results for the proposed CNN indicate that it is possible to generate H-PETs from neuro FDG L-PETs using the proposed CNN method, which might allow reductions in both scan time and injection dose.


1999 ◽  
Vol 602 ◽  
Author(s):  
A. Lisauskas ◽  
S.I. Khartsev ◽  
A.M. Grishin

AbstractUsing pulsed laser deposition technique we fabricated films of a continuous series of solid solutions La0.7(Pb1−xSrx)0.3MnO3, which undergo metal-to-insulator phase transition close and above room temperature. The optimal composition for uncooled bolometer applications was found at x = 0.37 with maximum of TCR = 7.4 %K−1@ 295 K. Room temperature bolometer demonstrator has been built and tested. Relatively low excess noise (magnitude γ/n of 3·10−21 cm−3) and high TCR enabled achievement of high signal-to-noise ratio of 8·106 √-Hz/K. The observed frequency dispersion of bolometer response has been ascribed to three relaxation mechanisms of the heat transfer: from film thermistor to substrate, from substrate to thermostat, and heat transfer via leads. For fabricated bolometer heat transfer from substrate to thermostat was found to be the slowest one with a time constant of 0.5 s (correspondent substrate-to-thermostat thermal conductance is G = 3·10−3 W/K). Bolometer performance test yields the responsivity ℜ = 0.6 V/W, detectivity D = 9·106 cm√Hz/W and noise equivalent power NEP of 3·10−8 W/√Hz at 30 Hz frame frequency. Further improvement of bolometer thermal isolation using the micromachining technique is believed to achieve the responsivity about 4·103 V/W and detectivity higher than 109 cm√Hz/W@30 Hz.


2020 ◽  
Vol 64 (1-4) ◽  
pp. 951-958
Author(s):  
Tianhao Liu ◽  
Yu Jin ◽  
Cuixiang Pei ◽  
Jie Han ◽  
Zhenmao Chen

Small-diameter tubes that are widely used in petroleum industries and power plants experience corrosion during long-term services. In this paper, a compact inserted guided-wave EMAT with a pulsed electromagnet is proposed for small-diameter tube inspection. The proposed transducer is noncontact, compact with high signal-to-noise ratio and unattractive to ferromagnetic tubes. The proposed EMAT is designed with coils-only configuration, which consists of a pulsed electromagnet and a meander pulser/receiver coil. Both the numerical simulation and experimental results validate its feasibility on generating and receiving L(0,2) mode guided wave. The parameters for driving the proposed EMAT are optimized by performance testing. Finally, feasibility on quantification evaluation for corrosion defects was verified by experiments.


2018 ◽  
Author(s):  
Satish Kodali ◽  
Liangshan Chen ◽  
Yuting Wei ◽  
Tanya Schaeffer ◽  
Chong Khiam Oh

Abstract Optical beam induced resistance change (OBIRCH) is a very well-adapted technique for static fault isolation in the semiconductor industry. Novel low current OBIRCH amplifier is used to facilitate safe test condition requirements for advanced nodes. This paper shows the differences between the earlier and novel generation OBIRCH amplifiers. Ring oscillator high standby leakage samples are analyzed using the novel generation amplifier. High signal to noise ratio at applied low bias and current levels on device under test are shown on various samples. Further, a metric to demonstrate the SNR to device performance is also discussed. OBIRCH analysis is performed on all the three samples for nanoprobing of, and physical characterization on, the leakage. The resulting spots were calibrated and classified. It is noted that the calibration metric can be successfully used for the first time to estimate the relative threshold voltage of individual transistors in advanced process nodes.


Nanophotonics ◽  
2020 ◽  
Vol 9 (8) ◽  
pp. 2569-2576 ◽  
Author(s):  
Lu Li ◽  
Lihui Pang ◽  
Qiyi Zhao ◽  
Yao Wang ◽  
Wenjun Liu

AbstractTransition metal dichalcogenides have been widely utilized as nonlinear optical materials for laser pulse generation applications. Herein, we study the nonlinear optical properties of a VS2-based optical device and its application as a new saturable absorber (SA) for high-power pulse generation. Few-layer VS2 nanosheets are deposited on the tapered region of a microfiber to form an SA device, which shows a modulation depth of 40.52%. After incorporating the microfiber-VS2 SA into an Er-doped fiber laser cavity, passively Q-switched pulse trains could be obtained with repetition rates varying from 95 to 233 kHz. Under the pump power of 890 mW, the largest output power and shortest pulse duration are measured to be 43 mW and 854 ns, respectively. The high signal-to-noise ratio of 60 dB confirms the excellent stability of the Q-switching state. To the best of our knolowdge, this is the first illustration of using VS2 as an SA. Our experimental results demonstrate that VS2 nanomaterials have a large potential for nonlinear optics applications.


2021 ◽  
Vol 13 (1) ◽  
pp. 168781402098732
Author(s):  
Ayisha Nayyar ◽  
Ummul Baneen ◽  
Syed Abbas Zilqurnain Naqvi ◽  
Muhammad Ahsan

Localizing small damages often requires sensors be mounted in the proximity of damage to obtain high Signal-to-Noise Ratio in system frequency response to input excitation. The proximity requirement limits the applicability of existing schemes for low-severity damage detection as an estimate of damage location may not be known  a priori. In this work it is shown that spatial locality is not a fundamental impediment; multiple small damages can still be detected with high accuracy provided that the frequency range beyond the first five natural frequencies is utilized in the Frequency response functions (FRF) curvature method. The proposed method presented in this paper applies sensitivity analysis to systematically unearth frequency ranges capable of elevating damage index peak at correct damage locations. It is a baseline-free method that employs a smoothing polynomial to emulate reference curvatures for the undamaged structure. Numerical simulation of steel-beam shows that small multiple damages of severity as low as 5% can be reliably detected by including frequency range covering 5–10th natural frequencies. The efficacy of the scheme is also experimentally validated for the same beam. It is also found that a simple noise filtration scheme such as a Gaussian moving average filter can adequately remove false peaks from the damage index profile.


2021 ◽  
Vol 12 (1) ◽  
Author(s):  
Francesco Giganti ◽  
Alex Kirkham ◽  
Veeru Kasivisvanathan ◽  
Marianthi-Vasiliki Papoutsaki ◽  
Shonit Punwani ◽  
...  

AbstractProstate magnetic resonance imaging (MRI) of high diagnostic quality is a key determinant for either detection or exclusion of prostate cancer. Adequate high spatial resolution on T2-weighted imaging, good diffusion-weighted imaging and dynamic contrast-enhanced sequences of high signal-to-noise ratio are the prerequisite for a high-quality MRI study of the prostate. The Prostate Imaging Quality (PI-QUAL) score was created to assess the diagnostic quality of a scan against a set of objective criteria as per Prostate Imaging-Reporting and Data System recommendations, together with criteria obtained from the image. The PI-QUAL score is a 1-to-5 scale where a score of 1 indicates that all MR sequences (T2-weighted imaging, diffusion-weighted imaging and dynamic contrast-enhanced sequences) are below the minimum standard of diagnostic quality, a score of 3 means that the scan is of sufficient diagnostic quality, and a score of 5 implies that all three sequences are of optimal diagnostic quality. The purpose of this educational review is to provide a practical guide to assess the quality of prostate MRI using PI-QUAL and to familiarise the radiologist and all those involved in prostate MRI with this scoring system. A variety of images are also presented to demonstrate the difference between suboptimal and good prostate MR scans.


Nanophotonics ◽  
2020 ◽  
Vol 9 (10) ◽  
pp. 3443-3450 ◽  
Author(s):  
Wei-Nan Liu ◽  
Rui Chen ◽  
Wei-Yi Shi ◽  
Ke-Bo Zeng ◽  
Fu-Li Zhao ◽  
...  

AbstractSelective transmission or filtering always responds to either frequency or incident angle, so as hardly to maximize signal-to-noise ratio in communication, detection and sensing. Here, we propose compact meta-filters of narrow-frequency sharp-angular transmission peak along with broad omnidirectional reflection sidebands, in all-dielectric cascaded subwavelength meta-gratings. The inherent collective resonance of waveguide-array modes and thin film approximation of meta-grating are employed as the design strategy. A unity transmission peak, locating at the incident angle of 44.4° and the center wavelength of 1550 nm, is demonstrated in a silicon meta-filter consisting of two-layer silicon rectangular meta-grating. These findings provide possibilities in cascaded meta-gratings spectroscopic design and alternative utilities for high signal-to-noise ratio applications in focus-free spatial filtering and anti-noise systems in telecommunications.


Sign in / Sign up

Export Citation Format

Share Document