scholarly journals Physico-Chemical Analysis of Wastewater Discharge from Selected Paint Industries in Lagos, Nigeria

Author(s):  
Tolulope Aniyikaiye ◽  
Temilola Oluseyi ◽  
John Odiyo ◽  
Joshua Edokpayi

Effluents from the paint industry have been a major source of environmental pollution. There is a need to investigate the compliance of wastewater discharged from paint industries with regulatory standards. In response, this study evaluates the physicochemical parameters of both raw and treated wastewater, the wastewater treatment plants (WWTPs) efficiencies as well as the compliance level of five selected paint manufacturing companies in Lagos, Nigeria with some regulatory standards: Federal Ministry of Environment (FME) in Nigeria, World Health Organization (WHO) and Department of Water Affairs (DWA) in South Africa. All parameters investigated were analysed using standard methods. The values of pH, electrical conductivity (EC) and total dissolved solids (TDS) levels were in the range of 4–12.2, 149.1–881.3 mS/m and 1100–6510 mg/L, respectively. The range of other parameters include total suspended solids (TSS); 0–2470 mg/L, TS; 1920–6510 mg/L, chloride; 63.8–733.8 mg/L, dissolved oxygen (DO); 0–6.7 mg/L, oil and grease (O & G); 44–100 mg/L, biochemical oxygen demand (BOD); 162.8–974.7 mg/L, chemical oxygen demand (COD); 543–1231 mg/L, nitrates;12.89–211.2 mg/L, phosphate; below detection limit (bdl)–0.02 mg/L, sulphate; 195–1434 mg/L, nickel; bdl–1.9 mg/L while copper, lead and chromium were below detection limits. The results indicated that the WWTPs of the studied paint companies were ineffective in reducing the TS, TSS, BOD, COD and (O & G) to acceptable limits. Routine monitoring of wastewater from paint industries is therefore recommended to prevent the risk of contamination to the receiving watershed which many communities rely on as source for domestic water.

Water ◽  
2019 ◽  
Vol 11 (2) ◽  
pp. 335 ◽  
Author(s):  
Delia Ventura ◽  
Simona Consoli ◽  
Salvatore Barbagallo ◽  
Alessia Marzo ◽  
Daniela Vanella ◽  
...  

This study reports an up-to-date summary of the principal barriers still limiting reclaimed water use for agriculture in Italy, and particularly in Sicily. Moreover, it provides a geographic informative system (GIS)-based procedure for evaluating the potential treated wastewater (TW) reuse in the Sicilian region as a decision support system for its management. The survey, based on possible economic, morphologic, and design solutions, evidenced a feasible integration of several wastewater treatment plants (WWTPs) with irrigation areas, allowing the water availability enhancement. Overall, the potential volume of TW by WWTPs (connected to irrigation districts) is 163 × 106 m3 year−1, while the water deficit is 66 × 106 m3 year−1. The feasibility of TW reuse in Sicily was also analysed at the light of the World Health Organization microbial risk assessment. Escherichia coli (E. coli) analyses mostly accomplished these guidelines while conflicting with the restrictive Italian standards. Despite several limiting factors (restrictive legislations, high distance and unfavourable slope between WWTPs and irrigable areas, high monitoring and distribution costs) still hamper the exploitation of reclaimed water use in Sicilian agriculture, some solutions were identified to implement this practice.


2013 ◽  
Vol 67 (7) ◽  
pp. 1512-1518 ◽  
Author(s):  
Elayse M. Hachich ◽  
Ana T. Galvani ◽  
Jose A. Padula ◽  
Nancy C. Stoppe ◽  
Suzi C. Garcia ◽  
...  

Brazilian regulations for nonpotable reuse are being established using World Health Organization guidelines, however, they should be developed based on local monitoring studies. This study intended to analyze enteroviruses, protozoa and viable Ascaris sp. eggs in raw (24) and treated (24) effluents from four Wastewater Treatment Plants of São Paulo State, Brazil. The protozoa were detected with the US Environmental Protection Agency (USEPA) Method 1623 in the treated effluents and by centrifugation/Immunomagnetic Separation in the raw influent samples. Viable Ascaris sp. eggs were analyzed according to a modified USEPA method. Enteroviruses were quantified by using human rhabdomyosarcoma cells after adequate concentration procedures. All wastewater influents were positive for Giardia sp. whereas Cryptosporidium sp. was detected in 58.3% of the samples. Giardia sp. and Cryptosporidium sp. were present in 79.2 and 25.0% respectively, of the treated wastewater samples. Viable Ascaris sp. eggs were detected in 50.0 and 12.5% of influent and treated wastewater samples. Enteroviruses were isolated in the 24 raw influent samples and in 46% of the treated samples. Taking into account the densities of Giardia sp. in some treated wastewaters intended to be used as reclaimed water, Quantitative Microbial Risk Assessment studies should be conducted to establish pathogen quantitative criteria for a future Brazilian regulation for water reuse.


2020 ◽  
Vol 6 (2) ◽  
pp. 23-28
Author(s):  
O. A. F Wokoma ◽  
◽  
O. S Edori ◽  

Wastewater samples were collected from an oil industry at the point of discharge for a period of two years, from January 2018 – December 2019. The wastewater samples were analyzed for different physicochemical parameters such as temperature, turbidity, total dissolved solids (TDS), total suspended solids (TSS), conductivity, pH, alkalinity, salinity, total hydrocarbon content (THC), biochemical oxygen demand (BOD) and chemical oxygen demand (COD) to examine their conformity to fulfill requirements as recommended by World Health Organization (WHO), Federal Ministry of Environment (FME) and Drinking Water Association (DWA). The results indicated that all the parameters in the discharged wastewater were within acceptable limits of the regulatory bodies. The field data showed that the investigated firm conformed to the law by carrying out proper procedures before discharging the effluents into the public drain and river. Therefore, the release of wastewater from the industry doesn't constitute a danger to the environment as well as aquatic organisms. Keywords: Physicochemical parameter, wastewater discharge, oil industry, environment, contaminants


Processes ◽  
2021 ◽  
Vol 9 (8) ◽  
pp. 1313
Author(s):  
Antonia Arroyo ◽  
Fabián Provoste ◽  
Montserrat Rodríguez ◽  
Ana L. Prieto

Polycyclic aromatic hydrocarbons (PAHs) are a family of organic compounds of widespread presence in the environment. They are recalcitrant, ubiquitous, prone to bioaccumulation, and potentially carcinogenic. Effluent from wastewater treatment plants (WWTPs) constitutes a major source of PAHs into water bodies, and their presence should be closely monitored, especially considering the increasing applications of potable and non-potable reuse of treated wastewater worldwide. Modeling the fate and distribution of PAHs in WWTPs is a valuable tool to overcome the complexity and cost of monitoring and quantifying PAHs. A mechanistic model was built to evaluate the fate of PAHs in both water and sludge lines of a Chilean WWTP. Naphthalene and benzo(a)pyrene were used as models of low-MW and high-MW PAHs. As there were no reported experimental data available for the case study, the influent load was determined through a statistical approach based on reported values worldwide. For both naphthalene and benzo(a)pyrene, the predominant mechanism in the water line was sorption to sludge, while that in the sludge line was desorption. Compared to other studies in the literature, the model satisfactorily describes the mechanisms involved in the fate and distribution of PAHs in a conventional activated sludge WWTP. Even though there is evidence of the presence of PAHs in urban centers in Chile, local regulatory standards do not consider PAHs in the disposal of WWTP effluents. Monitoring of PAHs in both treated effluents and biosolids is imperative, especially when considering de facto reuse and soil amendment in agricultural activities are currently practiced downstream of the studied WWTP.


2021 ◽  
Vol 11 (4) ◽  
pp. 1889 ◽  
Author(s):  
Agnieszka Micek ◽  
Krzysztof Jóźwiakowski ◽  
Michał Marzec ◽  
Agnieszka Listosz ◽  
Tadeusz Grabowski

The results of research on the efficiency and technological reliability of domestic wastewater purification in two household wastewater treatment plants (WWTPs) with activated sludge are presented in this paper. The studied facilities were located in the territory of the Roztocze National Park (Poland). The mean wastewater flow rate in the WWTPs was 1.0 and 1.6 m3/day. In 2017–2019, 20 series of analyses were done, and 40 wastewater samples were taken. On the basis of the received results, the efficiency of basic pollutant removal was determined. The technological reliability of the tested facilities was specified using the Weibull method. The average removal efficiencies for the biochemical oxygen demand in 5 days (BOD5) and chemical oxygen demand (COD) were 66–83% and 62–65%, respectively. Much lower effects were obtained for total suspended solids (TSS) and amounted to 17–48%, while the efficiency of total phosphorus (TP) and total nitrogen (TN) removal did not exceed 34%. The analyzed systems were characterized by the reliability of TSS, BOD5, and COD removal at the level of 76–96%. However, the reliability of TN and TP elimination was less than 5%. Thus, in the case of biogenic compounds, the analyzed systems did not guarantee that the quality of treated wastewater would meet the requirements of the Polish law during any period of operation. This disqualifies the discussed technological solution in terms of its wide application in protected areas and near lakes, where the requirements for nitrogen and phosphorus removal are high.


2020 ◽  
Vol 24 (3) ◽  
pp. 511-517
Author(s):  
O.B. Ovonramwen

Physicochemical analyses of surface and groundwater samples from eleven different locations in Ugbomro and Iteregbi, Delta State, Nigeria were sampled and analyzed for physicochemical parameters according to standard methods for the examination of water and wastewater. The following  mean and standard deviation were obtained from the groundwater of the communities: temp (oC) 22.46 ± 0.50 and 23.23 ± 0.99, pH 6.63 ± 0.68 and6.69 ± 0.24, dissolved oxygen (DO) (mg/L) 5.91 ± 0.46 and 5.73 ± 0.46, chemical oxygen demand (COD) (mg/L) 4.24 ± 0.01 and 4.43 ± 0.10, biochemical oxygen demand (BOD) (mg/L) 3.51 ± 0.38 and 3.84 ± 0.21, Turbidity (NTU) 1.22 ± 1.07 and 3.56 ± 0.77, electrical conductivity (EC) (μs/cm) 748.9 ± 215.79 and 786.67 ± 226.77, color (TCU) 1.22 ± 2.12 and 6.11 ± 2.11, total alkalinity (TA) (mg/L) 6.22 ± 7.38 and 14.11 ± 11.19, HCO3- (mg/L) 6.22 ± 7.38 and 14.11 ± 11.19, NO3 - (mg/L) 1.13 ± 0.62 and 2.89 ± 1.25, total solids (TS) (mg/L) 489.09 ± 180.17 and 664.95 ± 373.37, total suspended solids (TSS) (mg/L) 32.25 ± 24.29 and 123.86 ± 82.79, total dissolved solids (TDS) (mg/L) 456.78 ± 163.73 and 542.20 ± 450.66, Cl- (mg/L) 21.20 ± 3.20 and 20.10 ± 3.89, total hardness (TH) (mg/L) 26.67 ± 22.83 and 46.78 ± 36.17, Na (mg/L) 1.26 ± 0.06 and 1.16 ± 0.04, K (mg/L) 0.04 ± 0.01 and 0.06 ± 0.03, Mg (mg/L) 4.32 ± 3.23 and 6.96 ± 5.49, Ca (mg/L) 8.68 ± 9.35 and 18.12 ± 13.71 respectively. The results obtained were subjected to statistical analysis and compared with the standard set by the Standards Organization of Nigeria (SON) and the World Health Organization (WHO) for water samples. Some of the parameters did not meet the standards, hence the need for treatment. The present physio-chemical analyses of surface and groundwater quality of the two neighboring university areas, Ugbomro and Iteregbi, were done to assess the environmental status of  the environment before socio-economic impacts. Keywords: physicochemical, surface water, groundwater, water quality


2020 ◽  
Vol 8 (9) ◽  
pp. 1425
Author(s):  
Lara Pérez-Etayo ◽  
David González ◽  
José Leiva ◽  
Ana Isabel Vitas

Due to the global progress of antimicrobial resistance, the World Health Organization (WHO) published the list of the antibiotic-resistant “priority pathogens” in order to promote research and development of new antibiotics to the families of bacteria that cause severe and often deadly infections. In the framework of the One Health approach, the surveillance of these pathogens in different environments should be implemented in order to analyze their spread and the potential risk of transmission of antibiotic resistances by food and water. Therefore, the objective of this work was to determine the presence of high and critical priority pathogens included in the aforementioned list in different aquatic environments in the POCTEFA area (North Spain–South France). In addition to these pathogens, detection of colistin-resistant Enterobacteriaceae was included due its relevance as being the antibiotic of choice to treat infections caused by multidrug resistant bacteria (MDR). From the total of 80 analyzed samples, 100% of the wastewater treatment plants (WWTPs) and collectors (from hospitals and slaughterhouses) and 96.4% of the rivers, carried antibiotic resistant bacteria (ARB) against the tested antibiotics. Fifty-five (17.7%) of the isolates were identified as target microorganisms (high and critical priority pathogens of WHO list) and 58.2% (n = 32) of them came from WWTPs and collectors. Phenotypic and genotypic characterization showed that 96.4% were MDR and resistance to penicillins/cephalosporins was the most widespread. The presence of bla genes, KPC-type carbapenemases, mcr-1 and vanB genes has been confirmed. In summary, the presence of clinically relevant MDR bacteria in the studied aquatic environments demonstrates the need to improve surveillance and treatments of wastewaters from slaughterhouses, hospitals and WWTPs, in order to minimize the dispersion of resistance through the effluents of these areas.


2019 ◽  
Vol 2019 ◽  
pp. 1-10 ◽  
Author(s):  
Rabea Elmountassir ◽  
Bahia Bennani ◽  
Youssef Miyah ◽  
Ahlam Fegousse ◽  
Ghita El Mouhri ◽  
...  

Physicochemical and microbiological analyses of liquid hospital effluents have demonstrated that they are loaded with organic and inorganic pollutants then discharged into the sewerage networks without treatment. The aim of this study is to suggest an effective solution for their treatment. Column filtration is an adequate method to reduce the pollutant load which makes it possible to have a rate of abatement of 97% and 79% by filtering the pollutant material using sawdust of catia and red sawdust, respectively, with a filter bed height equal to 13 cm. Physicochemical parameters such as chemical oxygen demand, biological oxygen demand, nitrate, ammonia, phosphorus, electrical conductivity and the bacteriological parameters like fecal coliforms, Streptococci, and Staphylococci have been measured. The analysis of heavy metals displays compliance with the World Health Organization standards. The red sawdust and catia sawdust have been characterized by scanning electron microscopy and Fourier-transform infrared spectroscopy.


2019 ◽  
Vol 5 (3) ◽  
pp. eaau9124 ◽  
Author(s):  
Katariina M. M. Pärnänen ◽  
Carlos Narciso-da-Rocha ◽  
David Kneis ◽  
Thomas U. Berendonk ◽  
Damiano Cacace ◽  
...  

Integrated antibiotic resistance (AR) surveillance is one of the objectives of the World Health Organization global action plan on antimicrobial resistance. Urban wastewater treatment plants (UWTPs) are among the most important receptors and sources of environmental AR. On the basis of the consistent observation of an increasing north-to-south clinical AR prevalence in Europe, this study compared the influent and final effluent of 12 UWTPs located in seven countries (Portugal, Spain, Ireland, Cyprus, Germany, Finland, and Norway). Using highly parallel quantitative polymerase chain reaction, we analyzed 229 resistance genes and 25 mobile genetic elements. This first trans-Europe surveillance showed that UWTP AR profiles mirror the AR gradient observed in clinics. Antibiotic use, environmental temperature, and UWTP size were important factors related with resistance persistence and spread in the environment. These results highlight the need to implement regular surveillance and control measures, which may need to be appropriate for the geographic regions.


2021 ◽  
Vol 5 (2) ◽  
pp. 112-116
Author(s):  
F., F. Akinola ◽  
M., O. Lasisi ◽  
B., S. Awe

Groundwater pollution has increased as a result of poor waste disposal practices in developing countries. The purpose of this study was to determine the levels of physicochemical parameters and heavy metal concentrations in order to investigate the impact of dumpsites on groundwater and soil quality in Erinfun community. Four (4) water samples were collected hand dug well and four (4) soil samples designated Ss1 to Ss4 were collected at distances of 10, 20, 30 and 40 m, respectively, away from the waste dumpsite. Physicochemical parameters and traces such as odour, colour, taste and temperature, as well as Biochemical Oxygen Demand, Chemical Oxygen Demand, Dissolve Oxygen, Total Dissolve Solid, pH, and chloride were measured in collected water samples. Collected soil samples were also analyzed for heavy metals such as Magnesium, Zinc, Iron, Chromium, and Lead. All the physical parameters of the water samples analysed were found not to be within the acceptable limit of World Health Organization and Nigerian Standard of Drinking Water Quality standards. The chemical constituents tested were within the acceptable limit of World Health Organization and Nigerian Standard of Drinking Water Quality except for the Biochemical Oxygen Demand, Chemical Oxygen Demand and Dissolve Oxygen of water samples 1 and 2, respectively. The concentration of trace metals in water sample test were within health limit except for Magnesium and Iron which has the highest concentrations in water sample 1 at 10 m away from dumpsite (61.00 mg/l and 0.46 mg/l). Consequently, open dumpsites are discouraged, and constructed standard landfills with appropriate monitoring guidelines are recommended.


Sign in / Sign up

Export Citation Format

Share Document