In this study, the effect of biochar on the high temperature resistance of cementitious paste was investigated using multiple experimental methods. The weight loss, cracks, residual compressive strength, and ultrasonic pulse velocity (UPV) of biochar cementitious paste with 2% and 5% biochar exposed to 300, 550 and 900 °C were measured. The products and microstructures of biochar cementitious paste exposed to high temperatures were analyzed by X-ray diffraction, Fourier transform infrared spectroscopy, thermogravimetric analysis, and scanning electron microscopy. The results showed that the cracks of specimens exposed to high temperatures decreased with increasing biochar content. The addition of 2% and 5% biochar increased the residual compressive strength of the specimens exposed to 300 °C and the relative residual compressive strength at 550 °C. As the exposure temperature increased, the addition of biochar compensated for the decreasing ultrasonic pulse velocity. The addition of biochar contributed to the release of free water and bound water, and reduced the vapor pressure of the specimen. The addition of biochar did not change the types of functional groups and crystalline phases of the products of cementitious materials exposed to high temperatures. Biochar particles were difficult to observe at 900 °C in scanning electron microscopy images. In summary, because biochar has internal pores, it can improve the high-temperature resistance of cement paste.

Buildings ◽  
2021 ◽  
Vol 11 (9) ◽  
pp. 416
Author(s):  
Yunfeng Qian ◽  
Dingyi Yang ◽  
Yanghao Xia ◽  
Han Gao ◽  
Zhiming Ma

Ultra-high performance concrete (UHPC) has a high self-healing capacity and is prone to bursting after exposure to high temperatures due to its characteristics. This work evaluates the damage and improvement of UHPC with coarse aggregates through mechanical properties (compressive strength and ultrasonic pulse velocity), transport properties (water absorption and a chloride diffusion test), and micro-properties such as X-ray diffraction (XRD), Mercury intrusion porosimetry (MIP), and Scanning electronic microscopy (SEM). The result demonstrates that polypropylene (PP) fibers are more suitable for high temperature tests than polyacrylonitrile (PAN) fibers. The result shows that 400 °C is the critical temperature point. With the increase in temperature, the hydration becomes significant, and the internal material phase changes accordingly. Although the total pore volume increased, the percentage of various types of pores was optimized within 400 °C. The mass loss gradually increased and the ultrasonic pulse velocity gradually decreased. While the compressive strength first increased and then decreased, and the increase occurred within 25–400 °C. As for the transport properties, the chloride migration coefficient and capillary absorption coefficient both increased dramatically due to the higher sensitivity to temperature changes. The results of the property improvement test showed that at temperatures above 800 °C, the compressive strength recovered by more than 65% and the ultrasonic pulse velocity recovered by more than 75%. In terms of transport properties, compared to the results before self-healing, the chloride migration coefficient decreased by up to 59%, compared with 89% for the capillary absorption coefficient, after self-healing at 800 °C. With respect to the enhancement effect after exposure to high temperatures, the environment of a 5% Na2SO4 solution was not as good as the clean water environment. The corresponding changes in microstructure during the high temperatures and the self-healing process can explain the change in the pattern of macroscopic properties more precisely.


2018 ◽  
Vol 3 (1) ◽  
pp. 31
Author(s):  
Belaribi Hassiba ◽  
Mellas Mekki ◽  
Rahmani Fraid

The paper analyses the effects of high temperatures on the concrete residual strength using ultrasonic velocity (UPV). An experimental investigation was conducted to study the relationship between UPV residual data and compressive strength of concrete with different mixture proportions, cubic specimens with water-cement ratio of 0.35. They were heated in an electric furnace at temperatures ranging from 200°C to 600°C. In this experiment a comparison was made between the four groups which include two types of fibers steel 0,19%, 0,25% and 0,5%, polypropylene: 0,05%, 0,11% 0,16 % by volume. Cube specimens were tested in order to determine ultrasonic velocity. The compressive strength was tested too. According to the results, relations were established between ultrasonic velocity in the specimens and the compressive strength at different temperature and the range of the velocity of the waves were also determined for this kind of concrete. Result of the test showed that UPV test can be successfully used in order to verify the consistency of structures damaged by fire.


Crystals ◽  
2021 ◽  
Vol 11 (12) ◽  
pp. 1503
Author(s):  
Milad Nimafar ◽  
Bijan Samali ◽  
Saied Jalil Hosseini ◽  
Alireza Akhlaghi

The current paper presents the results of an experimental study on the application of calcium carbonate precipitation bacteria as a new approach to repairing damaged concrete when exposed to high temperatures. To do so, cylindrical and cubic concrete specimens were initially exposed to heat in a furnace for 1 h, after reaching two different temperatures of 600 and 800 °C. A heat rate of 5.5 °C per minute was used to achieve the target temperatures. Then, two types of bacteria, namely Sporosarcina pasteurii and Bacillus sphaericus, with cell concentration of 107 cells/mL, were utilized externally, to repair the thermal cracks, enhancing the mechanical properties and durability of the damaged concrete. The efficiency of the bacterial remediation technique was then evaluated through compressive strength, ultrasonic pulse velocity (UPV), and electrical conductivity tests on the control specimens (unexposed to heat), and those exposed to high temperature with or without bacterial healing. The experimental results demonstrate that the compressive strength of the test specimens exposed to temperatures of 600 and 800 °C decreased by about 31–44% compared with the control ones. However, compared to those damaged at 600 and 800 °C, the compressive strength of specimens repaired by the S. pasteurii and the B. sphaericus showed increases of 31–93%. This increase is associated with the precipitation of calcium carbonate in the deep and superficial cracks and pores of the damaged specimens. Furthermore, the ultrasonic pulse velocity of the specimens subjected to bacterial remediation had a significant increase of about 1.65–3.47 times compared with the damaged ones. In addition, the electrical conductivity of repaired specimens decreased by 22–36% compared with the damaged specimens.


2021 ◽  
Vol 13 (9) ◽  
pp. 168781402110349
Author(s):  
Yeol Choi ◽  
Joo-Won Kang ◽  
Tae-Yeon Hwang ◽  
Chang-Geun Cho

This paper presents the results of an experimental investigation on the relationship between strength and ultrasonic pulse velocity (UPV) of concrete exposed to high temperature, especially for a decision of building remodeling of concrete structures. The experiments were conducted at three different initial compressive strength levels for temperature up to 800°C. UPV, Compressive, and splitting tensile tests and UPV measurements were performed for unheated and heated concrete specimens. The measured UPV values in the present work were correlated with compressive and tensile strengths to estimate the strength of concrete. Based on the results, two linear equations for predicting compressive and tensile strength of concrete at elevated temperatures using UPV have been proposed. It is found that the difference of initial compressive strength of concrete does not have a significant effect on the strength reduction ratio after exposed to high temperatures. In addition, the reduction factors of compressive and tensile strengths in the present work do not well comply with the values of suggested by EN 1992-1-2.


2013 ◽  
Vol 12 (3) ◽  
Author(s):  
Sudarmadi Sudarmadi

In this paper a case study about concrete strength assessment of bridge structure experiencing fire is discussed. Assessment methods include activities of visual inspection, concrete testing by Hammer Test, Ultrasonic Pulse Velocity Test, and Core Test. Then, test results are compared with the requirement of RSNI T-12-2004. Test results show that surface concrete at the location of fire deteriorates so that its quality is decreased into the category of Very Poor with ultrasonic pulse velocity ranges between 1,14 – 1,74 km/s. From test results also it can be known that concrete compressive strength of inner part of bridge pier ranges about 267 – 274 kg/cm2 and concrete compressive strength of beam and plate experiencing fire directly is about 173 kg/cm2 and 159 kg/cm2. It can be concluded that surface concrete strength at the location of fire does not meet the requirement of RSNI T-12-2004. So, repair on surface concrete of pier, beam, and plate at the location of fire is required.


2021 ◽  
Vol 13 (4) ◽  
pp. 1881
Author(s):  
Mei-Yu Xuan ◽  
Yi Han ◽  
Xiao-Yong Wang

This study examines the hydration–mechanical–autogenous shrinkage–durability–sustainability properties of ternary composites with limestone filler (LF) and ground-granulated blast furnace slag (BFS). Four mixtures were prepared with a water/binder ratio of 0.3 and different replacement ratios varying from 0 to 45%. Multiple experimental studies were performed at various ages. The experimental results are summarized as follows: (1) As the replacement levels increased, compressive strength and autogenous shrinkage (AS) decreased, and this relationship was linear. (2) As the replacement levels increased, cumulative hydration heat decreased. At the age of 3 and 7 days, there was a linear relationship between compressive strength and cumulative hydration heat. (3) Out of all mixtures, the ultrasonic pulse velocity (UPV) and electrical resistivity exhibited a rapid increase in the early stages and tended to slow down in the latter stages. There was a crossover of UPV among various specimens. In the later stages, the electrical resistivity of ternary composite specimens was higher than plain specimens. (4) X-ray diffraction (XRD) results showed that LF and BFS have a synergistic effect. (5) With increasing replacement ratios, the CO2 emissions per unit strength reduced, indicating the sustainability of ternary composites.


2014 ◽  
Vol 605 ◽  
pp. 147-150
Author(s):  
Seong Uk Hong ◽  
Seung Hun Kim ◽  
Yong Taeg Lee

This study used the ultrasonic pulse velocity method, one of the non-destructive test methods that does not damage the building for maintenance of to-be-constructed concrete structures using recycled aggregates in order to estimate the compressive strength of high strength concrete structure using recycled coarse aggregate and provide elementary resources for technological establishment of ultrasonic pulse velocity method. 200 test pieces of high strength concrete 40, 50MPa using recycled coarse aggregate were manufactured by replacement rates (0, 30, 50, 100%) and age (1, 7, 28, 180days), and air curing was executed to measure compressive strength and wave velocity. As the result of compressive strength measurement, the one with age of 180day and design strength of 40MPa was 43.69MPa, recycled coarse aggregate replacement rate of 30% 50% 100% were 42.82, 41.22, 37.35MPa, and 50MPa was 52.50MPa, recycled coarse aggregate replacement rate of 30% 50% 100% were 49.02, 46.66, 45.30MPa, and while it could be seen that the test piece substituted with recycled aggregate was found to have lower strength than the test piece with natural aggregate only, but it still reached the design strength to a degree. The correlation of compressive strength and ultrasonic pulse velocity was found and regression analysis was conducted. The estimation formula for compressive strength of high strength concrete using recycled coarse aggregate was found to be Fc=0.069Vp4.05, R2=0.66