scholarly journals How to Improve Sensitivity of Sandwich Lateral Flow Immunoassay for Corpuscular Antigens on the Example of Potato Virus Y?

Sensors ◽  
2018 ◽  
Vol 18 (11) ◽  
pp. 3975 ◽  
Author(s):  
Shyatesa Razo ◽  
Vasily Panferov ◽  
Irina Safenkova ◽  
Yuri Varitsev ◽  
Anatoly Zherdev ◽  
...  

A simple approach was proposed to decrease the detection limit of sandwich lateral flow immunoassay (LFIA) by changing the conditions for binding between a polyvalent antigen and a conjugate of gold nanoparticles (GNPs) with antibodies. In this study, the potato virus Y (PVY) was used as the polyvalent antigen, which affects economically important plants in the Solanaceae family. The obtained polyclonal antibodies that are specific to PVY were characterized using a sandwich enzyme-linked immunosorbent assay (ELISA) and surface plasmon resonance (SPR). For LFIA, the antibodies were conjugated with GNPs with a diameter of 17.4 ± 1.0 nm. We conducted LFIAs using GNP conjugates in a dried state on the test strip and after pre-incubation with a sample. Pre-incubating the GNP conjugates and sample for 30 s was found to decrease the detection limit by 60-fold from 330 ng∙mL−1 to 5.4 ng∙mL−1 in comparison with conventional LFIA. The developed method was successfully tested for its ability to detect PVY in infected and uninfected potato leaves. The quantitative results of the proposed LFIA with pre-incubation were confirmed by ELISA, and resulted in a correlation coefficient of 0.891. The proposed approach is rapid, simple, and preserves the main advantages of LFIA as a non-laboratory diagnostic method.

Nanomaterials ◽  
2021 ◽  
Vol 11 (12) ◽  
pp. 3277
Author(s):  
Shyatesa C. Razo ◽  
Anastasiya I. Elovenkova ◽  
Irina V. Safenkova ◽  
Natalia V. Drenova ◽  
Yuri A. Varitsev ◽  
...  

The detection limit of lateral flow immunoassay (LFIA) is largely determined by the properties of the label used. We compared four nanoparticle labels differing in their chemical composition and colour: (1) gold nanoparticles (Au NPs), red; (2) Au-core/Pt-shell nanoparticles (Au@Pt NPs), black; (3) latex nanoparticles (LPs), green; and (4) magnetic nanoparticles (MPs), brown. The comparison was carried out using one target analyte—Erwinia amylovora, the causal bacterial agent of fire blight. All nanoparticles were conjugated with antibodies through methods that provide maximum functional coverage like physical adsorption (Au NPs, Au@Pt NPs) and covalent bonding (LPs, MPs). All conjugates demonstrated the same ability to bind with E. amylovora through enzyme-linked immunosorbent assay where optical properties of the nanoparticles do not determine the registered signal. However, half-maximal binding was achieved at different numbers of nanoparticles because they differ in size. All conjugates based on four nanoparticle labels were used for lateral flow assays. As a result, Au@Pt NPs provided the minimal detection limit that corresponded to 103 CFU/mL. Au NPs and LPs detected 104 CFU/mL, and MPs detected 105 CFU/mL. The results highlight that simply choosing a coloured label can significantly affect the detection limit of LFIA.


Author(s):  
Cheng Liu ◽  
Shuiqin Fang ◽  
Yachen Tian ◽  
Youxue Wu ◽  
Meijiao Wu ◽  
...  

Escherichia coli O157:H7 ( E. coli O157:H7) is a dangerous foodborne pathogen, mainly found in beef, milk, fruits, and their products, causing harm to human health or even death. Therefore, the detection of E. coli O157:H7 in food is particularly important. In this paper, we report a lateral flow immunoassay strip (LFIS) based on aggregation-induced emission (AIE) material labeling antigen as a fluorescent probe for the rapid detection of E. coli O157:H7. The detection sensitivity of the strip is 105 CFU/mL, which is 10 times higher than that of the colloidal gold test strip. This method has good specificity and stability and can be used to detect about 250 CFU of E. coli O157:H7 successfully in 25 g or 25 mL of beef, jelly, and milk. AIE-LFIS might be valuable in monitoring food pathogens for rapid detection.


2020 ◽  
Vol 58 (9) ◽  
Author(s):  
Katharina Ziegler ◽  
Anca Rath ◽  
Christoph Schoerner ◽  
Renate Meyer ◽  
Thomas Bertsch ◽  
...  

ABSTRACT Diagnosis of Lyme neuroborreliosis (LNB) is challenging, as long as Borrelia-specific intrathecal antibodies are not yet detectable. The chemokine CXCL13 is elevated in the cerebrospinal fluid (CSF) of LNB patients. Here, we compared the performances of the Euroimmun CXCL13 enzyme-linked immunosorbent assay (CXCL13 ELISA) and the ReaScan CXCL13 lateral flow immunoassay (CXCL13 LFA), a rapid point-of-care test, to support the diagnosis of LNB. In a dual-center case-control study, CSF samples from 90 patients (34 with definite LNB, 10 with possible LNB, and 46 with other central nervous system [CNS] diseases [non-LNB group]) were analyzed with the CXCL13 ELISA and the CXCL13 LFA. Classification of patients followed the European Federation of Neurological Societies (EFNS) guidelines on LNB. The CXCL13 ELISA detected elevated CXCL13 levels in all patients with definite LNB (median, 1,409 pg/ml) compared to the non-LNB controls (median, 20.7 pg/ml; P < 0.0001), with a sensitivity of 100% and a specificity of 84.8% (cutoff value, 78.6 pg/ml; area under the receiver operating characteristic [ROC] curve, 0.93). Similarly, the CXCL13 LFA yielded elevated CXCL13 levels in 31 patients with definite LNB (median arbitrary value, 223.5) compared to the non-LNB control patients (median arbitrary value, 0; P < 0.0001) and had a sensitivity and specificity of 91.2% and 93.5%, respectively (cutoff arbitrary value, 22.5; area under the ROC curve, 0.94). The correlation between the CXCL13 levels obtained by ELISA and LFA was strong (Spearman correlation coefficient r = 0.89; P < 0.0001). The CXCL13 ELISA and the CXCL13 LFA are comparable diagnostic tools for the detection of CXCL13 in the CSF of patients with definite LNB. The advantage of the CXCL13 LFA is the shorter time to result.


Plant Disease ◽  
2013 ◽  
Vol 97 (5) ◽  
pp. 641-644 ◽  
Author(s):  
Manphool S. Fageria ◽  
Mathuresh Singh ◽  
Upeksha Nanayakkara ◽  
Yvan Pelletier ◽  
Xianzhou Nie ◽  
...  

The current-season spread of Potato virus Y (PVY) was investigated in New Brunswick, Canada, in 11 potato fields planted with six different cultivars in 2009 and 2010. In all, 100 plants selected from each field were monitored for current-season PVY infections using enzyme-linked immunosorbent assay (ELISA) and real-time reverse-transcription polymerase chain reaction (RT-PCR) assay. Average PVY incidence in fields increased from 0.6% in 2009 and 2% in 2010 in the leaves to 20.3% in 2009 and 21.9% in 2010 in the tubers at the time of harvest. In individual fields, PVY incidence in tubers reached as high as 37% in 2009 and 39% in 2010 at the time of harvest. Real-time RT-PCR assay detected more samples with PVY from leaves than did ELISA. A higher number of positive samples was also detected with real-time RT-PCR from growing tubers compared with the leaves collected from the same plant at the same sampling time. PVY incidence determined from the growing tubers showed a significant positive correlation with the PVY incidence of tubers after harvest. Preharvest testing provides another option to growers to either top-kill the crop immediately to secure the seed market when the PVY incidence is low or leave the tubers to develop further for table or processing purposes when incidence of PVY is high.


Plant Disease ◽  
2001 ◽  
Vol 85 (4) ◽  
pp. 447-447 ◽  
Author(s):  
X. D. Li ◽  
Y. Q. Li ◽  
H. G. Wang

Flue-cured tobacco is an important crop in Henan Province, China. During the 2000 growing season, many tobacco plants showed various degrees of mottling, mosaic, vein clearing, or vein necrosis in most of the counties. Some plants even died at an early stage of growth. A survey was conducted in May-June in several tobacco-growing counties, and the incidence of symptomatic plants in individual fields ranged from 10 to 85%. The most widely planted tobacco varieties, NC89, K326, and K346, were highly susceptible. Symptomatic plants were collected from Jiaxian and Xiangcheng counties and samples were tested by enzyme-linked immunosorbent assay for Tobacco mosaic virus (TMV), Cucumber mosaic virus (CMV), Potato virus Y (PVY), and Potato virus X (PVX). Of 65 samples tested, 21 were positive for only PVY, 16 positive for only CMV, one each was positive for only TMV or PVX. Nineteen samples were doubly infected with various combinations of these viruses and six were infected with combinations of three viruses. The causal agent(s) in the remaining sample could not be determined. In total, CMV was detected in 40 samples, PVY in 38, PVX in 10, and TMV in 7 samples. TMV and CMV used to be the most important viruses and PVY occurred only rarely. But PVY has become prevalent in Henan and in neighboring Shandong province (2). CMV and TMV were reported to be the most prevalent viruses in Shanxi (1) and Fujian Provinces (3). Because resistant varieties are not available, and mixed infections are more common, the results presented here explain why huge damage is occurring in tobacco crops in recent years. Some varieties are partially resistant to TMV and CMV but the varieties commonly grown are highly susceptible to PVY. Therefore, breeding for resistance to viruses, especially to PVY, is urgent to control the occurrence of tobacco viral diseases. References: (1) J. L. Cheng et al. Acta Tabacaria Sin. 4:43, 1998. (2) J. B. Wang et al. Chinese Tobacco Sci. 1:26, 1998. (3) L. H. Xie et al. Acta Tabacaria Sin. 2:25, 1994.


2019 ◽  
Vol 9 (1) ◽  
Author(s):  
Tsung-Ting Tsai ◽  
Tse-Hao Huang ◽  
Natalie Yi-Ju Ho ◽  
Yu-Pei Chen ◽  
Chung-An Chen ◽  
...  

Abstract The diagnosis of periprosthetic joint infection (PJI) remains a challenge. However, recent studies showed that synovial fluid biomarkers have demonstrated greater diagnostic accuracy than the currently used PJI diagnostic tests. In many diagnostic tests, combining several biomarkers into panels is critical for improving diagnostic efficiency, enhancing the diagnostic precision for specific diseases, and reducing cost. In this study, we prove that combining alpha-defensin and C-reactive protein (CRP) as biomarkers possesses the potential to provide accurate PJI diagnosis. To further verify the result, we developed a multi-target lateral flow immunoassay strip (msLFIA) with staking pad design to obtain on-site rapid response for clinical diagnosis of PJI. A total of 10 synovial fluid samples were tested using the msLFIA, and the results showed that the combined measurements of synovial fluid alpha-defensin and CRP levels were consistent with those obtained from a commercial enzyme-linked immunosorbent assay kit. In addition, we developed a multi-target lateral flow immunoassay strip (msLFIA) with staking pad design to obtain on-site rapid response for clinical diagnosis of PJI, which the multi-target design is used to increase specificity and the stacking pad design is to enhance detection sensitivity. As a result, the turnaround time of the highly sensitive test can be limited from several hours to 20 min. We expect that the developed msLFIA possesses the potential for routine monitoring of PJI as a convenient, low-cost, rapid and easy to use detection device for PJI.


1993 ◽  
Vol 76 (2) ◽  
pp. 381-386 ◽  
Author(s):  
W Harvey Newsome ◽  
Jupiter M Yeung ◽  
Peter G Collins

Abstract A simple, sensitive, and precise enzyme-linked immunosorbent assay (ELISA) is described for the quantitation of captan as its degradation product tetrahydrophthalimide (THPI) in foods using polyclonal antibodies. Three hapten analogues of THPI with different alky I spacer arm lengths were synthesized. Immunogens and coating proteins were prepared by coupling these haptens to human serum albumin and ovalbumin, respectively. A 5-carbon spacer arm appeared to be optimum for the production of antibodies. Heterologous coating proteins did not improve the sensitivity, but reduction of homologous coating protein concentration did improve the sensitivity, resulting in a concentration of test compound required to inhibit binding by 50% of 15.5 ng/mL The antiserum is specific for captan, captafol, and THPI, but not other structurally related compounds. The minimum detection limit was 1 ng/mL; the linearity was 1-200 ng/mL. The overall recoveries of captan and THPI from 11 commodities spiked at 4 levels were 92 and 100%, respectively. The intra-assay and interassay coefficients of variation were 9.1 and 16.8% for apple blanks and 5.9 and 4.2% for apple spiked with 3 ppm THPI, respectively. The ELISA described is suitable for measuring captan and THPI at levels comparable to those typically found in fruit.


1996 ◽  
Vol 59 (9) ◽  
pp. 992-997 ◽  
Author(s):  
FENG-YIR YU ◽  
FUN S. CHU

Polyclonal antibodies against fumonisin B1 (FmB1) were produced in rabbits after immunizing the animals with either FmBl-keyhole limpet hemocyanin (KLH) or FmB1 bovine serum albumin (BSA). A direct competitive enzyme-linked immunosorbent assay (dc-ELISA) and an indirect competitive ELISA (idc-ELISA) were used for the characterization of the antibodies and for analysis of the toxin in corn samples. The antibody titers in the serum of rabbits immunized with FmBl-KLH were considerably higher than in those immunized with FmBl-BSA. The antibodies from the rabbits immunized with FmBl-KLH were further characterized. The concentrations causing 50% inhibition of binding of FmB1-horseradish peroxidase (HRP) to the antibodies by FmB1, FmB2 and FmB3 in the ELISA were found to be 0.45, 0.72, and 25 ng/ml, respectively. The detection limit of FmBl, based on 95% confidence at 5% of inhibition of binding of FmBl-HRP conjugate, in buffer of the dc-ELISA was found to be 0.05 ng/ml. In the presence of a matrix such as corn, the detection limit was less than 50 ppb. The overall analytical recoveries of FmBl (50 to 1,000 ng/g) added to the ground corn and then extracted with CH3CN/H2O (1/1, vol/vol) with cleanup and without cleanup in the dc ELISA were found to be 70.5 and 85.9%, respectively. A good correlation was found between the FmBl levels in 2 starch and 10 naturally contaminated corn samples analyzed by the dc-ELISA and the high-pressure liquid chromatography (HPLC) method. The correlation coefficients between ELISA and HPLC were found to be 0.955 (y [ELISA] = 1.3 1x [HPLC] + 77 ppb; P &lt; 0.001) and 0.811 (y = 1.13x + 34 ppb; P &lt; 0.01) for the sample without and with cleanup treatment, respectively.


Sign in / Sign up

Export Citation Format

Share Document