scholarly journals Validation of a Novel Boxing Monitoring System to Detect and Analyse the Centre of Pressure Movement on the Boxer’s Fist

Sensors ◽  
2021 ◽  
Vol 21 (24) ◽  
pp. 8394
Author(s):  
Tobias Menzel ◽  
Wolfgang Potthast

The examination of force distribution and centre of pressure (CoP) displacement is a common method to analyse motion, load, and load distribution in biomechanical research. In contrast to gait analysis, the force progression in boxing punches is a new field of investigation. The centre of pressure displacement and distribution of forces on the surface of the fist during a boxing punch is of great interest and crucial to understanding the effect of the punch on the biological structures of the hand as well as the technical biomechanical aspects of the punching action. This paper presents a new method to display the CoP progression on the boxer’s fist Therefore, this study presents the validation of the developed novel boxing monitoring system in terms of CoP displacement. In addition, the CoP progression of different punching techniques in boxing is analysed on the athlete’s fist. The accuracy of the examination method of the CoP course was validated against the gold standard of a Kistler force plate. High correlations were detected between the developed sensor system and the force plate CoP with a Pearson correlation coefficient ranging from 0.93 to 0.97. The information obtained throughout the experimental study is of great importance in order to gain further knowledge into the technical execution of boxing punches as well as to provide a novel measuring method for determining CoP on the surface of the fist, to improve the understanding of the etiology of boxing-related hand injuries.

2003 ◽  
Vol 16 (03) ◽  
pp. 170-177 ◽  
Author(s):  
S. Kennedy ◽  
D. V. Lee ◽  
J. E. A. Bertram ◽  
G. Lust ◽  
A. J. Williams ◽  
...  

SummaryThe effect of canine hip osteoarthritis (OA) on vertical force distribution was studied using a serial force platform system. This system allows simultaneous measurement of vertical and horizontal force impulses from each limb of a trotting dog. Using these measurements and novel analysis techniques a complete and precise analysis of load distribution was performed. Load distribution was compared between a group of normal dogs and a group of dogs with radiographic evidence of hip OA. Results of this study indicate that trotting dogs with hip OA redistribute vertical force primarily by shifting force between trotting pairs (side-to-side compensation) rather than within trotting pairs (hind-to-fore compensation).


2016 ◽  
Vol 1 (1) ◽  
pp. 1-15
Author(s):  
Frederich Oscar Lontoh

This research is titled " The influence of sermon, church music and church facilities on the level of attendance”. The purpose of research is to identify and analyze whether sermon, church music and church facilities have influence on the the level of attendance. The target population in this study is a Christian church members who live in the city of Surabaya.. Sample required is equal to 47 respondents. Through sampling stratified Random techniques.These influence was measured using Pearson correlation coefficient and multiple regression analysis, t-test and analysis of variance. Descriptive  analysis  were taken to analyze the level of attendance according to demographic groups.The hypothesis in this study are the sermon, church music and church facilities have positive and significant on the level of attendance. The results showed that collectively, there are positive and significant correlation among the sermon, church music and church facilities on the level of attendance  96,2%. It means that 96,2 % of level of attendance influenced by sermon, church music and church facilities and the other 28,9% by others. All of the variable partially have significant correlation to level of attendance.


2020 ◽  
Vol 16 (1) ◽  
pp. 47-53
Author(s):  
Vicente Benavides-Córdoba ◽  
Mauricio Palacios Gómez

Introduction: Animal models have been used to understand the pathophysiology of pulmonary hypertension, to describe the mechanisms of action and to evaluate promising active ingredients. The monocrotaline-induced pulmonary hypertension model is the most used animal model. In this model, invasive and non-invasive hemodynamic variables that resemble human measurements have been used. Aim: To define if non-invasive variables can predict hemodynamic measures in the monocrotaline-induced pulmonary hypertension model. Materials and Methods: Twenty 6-week old male Wistar rats weighing between 250-300g from the bioterium of the Universidad del Valle (Cali - Colombia) were used in order to establish that the relationships between invasive and non-invasive variables are sustained in different conditions (healthy, hypertrophy and treated). The animals were organized into three groups, a control group who was given 0.9% saline solution subcutaneously (sc), a group with pulmonary hypertension induced with a single subcutaneous dose of Monocrotaline 30 mg/kg, and a group with pulmonary hypertension with 30 mg/kg of monocrotaline treated with Sildenafil. Right ventricle ejection fraction, heart rate, right ventricle systolic pressure and the extent of hypertrophy were measured. The functional relation between any two variables was evaluated by the Pearson correlation coefficient. Results: It was found that all correlations were statistically significant (p <0.01). The strongest correlation was the inverse one between the RVEF and the Fulton index (r = -0.82). The Fulton index also had a strong correlation with the RVSP (r = 0.79). The Pearson correlation coefficient between the RVEF and the RVSP was -0.81, meaning that the higher the systolic pressure in the right ventricle, the lower the ejection fraction value. Heart rate was significantly correlated to the other three variables studied, although with relatively low correlation. Conclusion: The correlations obtained in this study indicate that the parameters evaluated in the research related to experimental pulmonary hypertension correlate adequately and that the measurements that are currently made are adequate and consistent with each other, that is, they have good predictive capacity.


Author(s):  
María Leonila García Cedeño ◽  
Anicia Katherine Tarazona Meza ◽  
Robert Gonzalo Cedeño Mejía

Resilience is a phenomenon that can be studied in catastrophic situations but also in everyday matters such as disability, this being an alternative way of working in the environment that requires the adaptation of the social networks that contain and support people with this condition. The research was conducted at the Technical University of Manabí applied to the population of students with disabilities. The paper presents an analysis of support networks and their relationship with student resilience. The results related to the application of the Saavedra-Villalta test are shown, which allowed to correlate the level of resilience of the sample studied with the support networks. An analysis linked to the interpretation of the Pearson correlation coefficient is presented. The result obtained is presented by applying semi-structured interviews to a sample of 48 disabled students.


2008 ◽  
Vol 580-582 ◽  
pp. 557-560 ◽  
Author(s):  
J.G. Han ◽  
Kyong Ho Chang ◽  
Gab Chul Jang ◽  
K.K. Hong ◽  
Sam Deok Cho ◽  
...  

Recently, in the loading tests for steel members, the deformation value is measured by calculating a distance of both cross-heads. This measuring method encounters a test error due to various environmental factors, such as initial slip, etc.. Especially, in the case of welded members, the non-uniform deformation behavior in welded joints is observed because of the effect of welding residual stress and weld metal. This is mainly responsible for a test error and a loss of the reliability for used test instruments. Therefore, to improve the accuracy and the applicability of measuring system, it is necessary to employ a visual monitoring system which can accurately measure the local and overall deformation of welded members. In this paper, to accurately measure a deformation of welded members, a visual monitoring system (VMS) was developed by using three-dimensional digital photogrammetry. The VMS was applied to the loading tests of a welded member. The accuracy and the applicability of VMS was verified by comparing to the deformation value measured by a test instrument (MTS-810). The characteristics of the behavior near a welded joint were investigated by using VMS.


Sensors ◽  
2020 ◽  
Vol 21 (1) ◽  
pp. 156
Author(s):  
Charles Carlson ◽  
Vanessa-Rose Turpin ◽  
Ahmad Suliman ◽  
Carl Ade ◽  
Steve Warren ◽  
...  

Background: The goal of this work was to create a sharable dataset of heart-driven signals, including ballistocardiograms (BCGs) and time-aligned electrocardiograms (ECGs), photoplethysmograms (PPGs), and blood pressure waveforms. Methods: A custom, bed-based ballistocardiographic system is described in detail. Affiliated cardiopulmonary signals are acquired using a GE Datex CardioCap 5 patient monitor (which collects ECG and PPG data) and a Finapres Medical Systems Finometer PRO (which provides continuous reconstructed brachial artery pressure waveforms and derived cardiovascular parameters). Results: Data were collected from 40 participants, 4 of whom had been or were currently diagnosed with a heart condition at the time they enrolled in the study. An investigation revealed that features extracted from a BCG could be used to track changes in systolic blood pressure (Pearson correlation coefficient of 0.54 +/− 0.15), dP/dtmax (Pearson correlation coefficient of 0.51 +/− 0.18), and stroke volume (Pearson correlation coefficient of 0.54 +/− 0.17). Conclusion: A collection of synchronized, heart-driven signals, including BCGs, ECGs, PPGs, and blood pressure waveforms, was acquired and made publicly available. An initial study indicated that bed-based ballistocardiography can be used to track beat-to-beat changes in systolic blood pressure and stroke volume. Significance: To the best of the authors’ knowledge, no other database that includes time-aligned ECG, PPG, BCG, and continuous blood pressure data is available to the public. This dataset could be used by other researchers for algorithm testing and development in this fast-growing field of health assessment, without requiring these individuals to invest considerable time and resources into hardware development and data collection.


Author(s):  
Giulia Seghezzo ◽  
Yvonne Van Hoecke ◽  
Laura James ◽  
Donna Davoren ◽  
Elizabeth Williamson ◽  
...  

Abstract Background The Preclinical Alzheimer Cognitive Composite (PACC) is a composite score which can detect the first signs of cognitive impairment, which can be of importance for research and clinical practice. It is designed to be administered in person; however, in-person assessments are costly, and are difficult during the current COVID-19 pandemic. Objective To assess the feasibility of performing the PACC assessment with videoconferencing, and to compare the validity of this remote PACC with the in-person PACC obtained previously. Methods Participants from the HEalth and Ageing Data IN the Game of football (HEADING) Study who had already undergone an in-person assessment were re-contacted and re-assessed remotely. The correlation between the two PACC scores was estimated. The difference between the two PACC scores was calculated and used in multiple linear regression to assess which variables were associated with a difference in PACC scores. Findings Of the 43 participants who were invited to this external study, 28 were re-assessed. The median duration in days between the in-person and the remote assessments was 236.5 days (7.9 months) (IQR 62.5). There was a strong positive correlation between the two assessments for the PACC score, with a Pearson correlation coefficient of 0·82 (95% CI 0·66, 0·98). The multiple linear regression found that the only predictor of the PACC difference was the time between assessments. Interpretation This study provides evidence on the feasibility of performing cognitive tests online, with the PACC tests being successfully administered through videoconferencing. This is relevant, especially during times when face-to-face assessments cannot be performed.


Water ◽  
2021 ◽  
Vol 13 (1) ◽  
pp. 82
Author(s):  
Omolola M. Adisa ◽  
Muthoni Masinde ◽  
Joel O. Botai

This study examines the (dis)similarity of two commonly used indices Standardized Precipitation Index (SPI) computed over accumulation periods 1-month, 3-month, 6-month, and 12-month (hereafter SPI-1, SPI-3, SPI-6, and SPI-12, respectively) and Effective Drought Index (EDI). The analysis is based on two drought monitoring indicators (derived from SPI and EDI), namely, the Drought Duration (DD) and Drought Severity (DS) across the 93 South African Weather Service’s delineated rainfall districts over South Africa from 1980 to 2019. In the study, the Pearson correlation coefficient dissimilarity and periodogram dissimilarity estimates were used. The results indicate a positive correlation for the Pearson correlation coefficient dissimilarity and a positive value for periodogram of dissimilarity in both the DD and DS. With the Pearson correlation coefficient dissimilarity, the study demonstrates that the values of the SPI-1/EDI pair and the SPI-3/EDI pair exhibit the highest similar values for DD, while the SPI-6/EDI pair shows the highest similar values for DS. Moreover, dissimilarities are more obvious in SPI-12/EDI pair for DD and DS. When a periodogram of dissimilarity is used, the values of the SPI-1/EDI pair and SPI-6/EDI pair exhibit the highest similar values for DD, while SPI-1/EDI displayed the highest similar values for DS. Overall, the two measures show that the highest similarity is obtained in the SPI-1/EDI pair for DS. The results obtainable in this study contribute towards an in-depth knowledge of deviation between the EDI and SPI values for South Africa, depicting that these two drought indices values are replaceable in some rainfall districts of South Africa for drought monitoring and prediction, and this is a step towards the selection of the appropriate drought indices.


2020 ◽  
Vol 154 (Supplement_1) ◽  
pp. S110-S110
Author(s):  
A Vijayanarayanan ◽  
K Inamdar ◽  
M Menon ◽  
P Kuriakose

Abstract Introduction/Objective Myeloma diagnosis by a pathologist requires 10% plasma cells (PC) or a biopsy proven plasmacytoma in addition to myeloma defining events. PC% &gt; 60% is a biomarker of malignancy under this definition. WHO allows for assesment of plasma cell percentage either by aspirate count or by CD138 immunohistochemistry (IHC). There is lack of consensus on aspirate smear adequacy for PC% estimation. Uneven distribution of plasma cells, hemodilution and/or patchy infiltration can lead to gross underestimation. We compared PC% by aspirate count and CD138 IHC and established corelation with serum protein electrophoresis (SPEP) values. Methods 67 myeloma cases were included after excluding cases with suboptimal or inadequate aspirate smears. Two hematopathologists evaluated the diagnostic marrow (therapy naive) for PC% by aspirate count and CD138 IHC on biopsy/clot section. Corresponding SPEP and Free light chain (FLC) values were obtained. Correlation coefficent was calculated using Pearson correlation coefficient (GraphPad Prism). Results The Ig subtypes included IgG (41/67) and IgA (17/67). 12 cases had available FLC values. Both average and median PC% by CD138 IHC was considerably higher (50%, 52%) compared to aspirate count (29%, 21%). However, PC% by aspirate smear count and CD138 IHC demonstrated a significant linear correlation (r=0.71, p60% by CD138 (and not by aspirate count). Conclusion CD138 IHC based PC% is consistently higher, nevertheless, statistically significant linear corelation is observed between aspirate count PC% and CD138 IHC. A significant linear correlation is observed between CD138 IHC and SPEP (IgG and IgA), however, no such correlation is observed with aspirate count. More cases were diagnosed as myeloma (11%) and higher propotion of cases (35%) had biomarker of malignancy i.e. PC% &gt;60% by CD138 IHC. Based on these findings, we propose estimation of PC% by CD138 immunostain be a recommended standard practice for better clinicopathologic and biologic correlation.


Sign in / Sign up

Export Citation Format

Share Document