scholarly journals Assessment of the Odour Impact Range of a Selected Agricultural Processing Plant

2020 ◽  
Vol 12 (18) ◽  
pp. 7289
Author(s):  
Izabela Sówka ◽  
Marcin Pawnuk ◽  
Urszula Miller ◽  
Agnieszka Grzelka ◽  
Alicja Wroniszewska ◽  
...  

Within the research, on the premises of an agricultural plant, the odour concentration was measured, and the odour emission was determined. The obtained values allowed us to analyse the odour distribution using the Polish reference mathematical model for four different scenarios, including (1) all identified emission sources, i.e., point and surface: scenarios 1 and 2, and (2) only point sources, scenario 3 and 4. The values of the comparative level and the frequency of exceedances in scenarios 1 and 3 were based on the Polish draft act on counteracting odour nuisance, while the Dutch guidelines were used for scenarios 2 and 4. Model calculations showed the potential impact of the tested structure on adjacent residential areas, i.e., in scenarios 1 and 2, the permissible value of the frequency of exceedances was exceeded at all points representing residential buildings. The exceedances for scenario 3 and 4 took place in seven out of eight and two out of eight points, respectively. The results indicated that to accurately and reliably assess the odour impact and to determine the measures to prevent and reduce odour emissions, it is necessary to consider all types of emission sources in the facilities potentially causing odour nuisance.

2019 ◽  
Vol 100 ◽  
pp. 00070 ◽  
Author(s):  
Elżbieta Romanik ◽  
Yaroslav Bezyk ◽  
Marcin Pawnuk ◽  
Urszula Miller ◽  
Agnieszka Grzelka

Odour concentration measurements in a chosen industrial source were made in this study using the method of dynamic olfactometry. The two different scenarios considered the variation of the odour emission rate as input for the dispersion model were compared for the period 2017 (before installation of the equipment for gas treatment) and 2018 (after implementation of purifying technologies). In this paper the odour impact range was determined by applying model calculations conducted in the Polish reference dispersion model – OPERAT FB software for the grid size 2 x 2 km. The conducted research shows a significant improvement in the odour impact range of chosen industrial source in year 2018 compared to 2017.


2015 ◽  
Vol 16 (6) ◽  
pp. 579-589 ◽  
Author(s):  
Tsubasa Shimoji ◽  
Hayato Tahara ◽  
Hidehito Matayoshi ◽  
Atsushi Yona ◽  
Tomonobu Senjyu

Abstract From the perspective of global warming suppression and the depletion of energy resources, renewable energies, such as the solar collector (SC) and photovoltaic generation (PV), have been gaining attention in worldwide. Houses or buildings with PV and heat pumps (HPs) are recently being used in residential areas widely due to the time of use (TOU) electricity pricing scheme which is essentially inexpensive during middle-night and expensive during day-time. If fixed batteries and electric vehicles (EVs) can be introduced in the premises, the electricity cost would be even more reduced. While, if the occupants arbitrarily use these controllable loads respectively, power demand in residential buildings may fluctuate in the future. Thus, an optimal operation of controllable loads such as HPs, batteries and EV should be scheduled in the buildings in order to prevent power flow from fluctuating rapidly. This paper proposes an optimal scheduling method of controllable loads, and the purpose is not only the minimization of electricity cost for the consumers, but also suppression of fluctuation of power flow on the power supply side. Furthermore, a novel electricity pricing scheme is also suggested in this paper.


2018 ◽  
Vol 878 ◽  
pp. 202-209 ◽  
Author(s):  
Feng Qian ◽  
Li Yang

The natural ventilation of residential areas has placed more and more emphasis on residential area planning, according to the relationship between natural ventilation environments and the layout of architecture, we can reduce the energy consumption and the adverse effect of wind outdoors, improve the living environment and quality of life, making harmony between human and the nature. In this paper, we use Air-Pak to simulate the wind environment of residential areas. Through analyzing and simulating the air field which forms when the wind blows around the residential buildings by Air-Pak, we explain the advantage of the combination of computer simulation software and residential area planning. And we give some advice to the layout of the outdoor environment early in the residential planning area by the simulation of outdoor environments of buildings.


the emission; this is the entrance of the airborne pollutants into the open atmosphere. The local position of this entrance is the emission source, - the transmission, including all phenomena of transport, dispersion and dilution in the open atmosphere, - the immission; this is the entrance of the pollutant into an acceptor. As we are regarding odoriferous pollutants, the immisson is their entrance into a human nose. About air pollution from industrial emission sources, i.g. S02 from power plants, a wide knowledge is available, including sophisticated methods of emission measurement, atmospheric diffusion calculation and measurement of immission concentration in the ambient air. In most countries we have complete national legal regulations, concerning limitation of air contaminent emissions, calculation of stack height and at least evaluation and determination of maximum inmission values. Within this situation the question arises, whether these wellproved methods and devices are suitable for agricultural odour emissions from agricultural sources too. It is well known that all calculations and values, established in air pollution control, are based on large sets of data, obtained by a multitude of experiments and observations. The attempt to apply these established dispersion models to agricultural emission sources, leads to unreasonable results. A comparison in table 1 shows that the large scale values of industrial air pollutions, on which the established dispersion models are based, are too different from those in agriculture. In order to modify the existing dispersion models or to design other types of models, we need the corresponding sets of observations and of experimental data, adequate to the typical agricultural conditions. There are already a lot of investigations to measure odour at the source and in the ambient air. But we all know about the reliability of those measurements and about the difficulties to quantify these results adequate to a computer model calculating the relation between emission and immision depending on various influences and parameters. So we decided to supplement the odour measurements by tracer gas measurements easy to realise with high accuracy. The aim is to get the necessary sets of experimental data for the modification of existing dispersion models for agricultural conditions. 2. INSTRUMENTAL 2.1 EMISSION the published guideline VDI 3881 /2-4/ describes, how to measure odour emissions for application in dispersion models. Results obtained by this method have to be completed with physical data like flow rates etc. As olfactometric odour threshold determination is rather expensive, it is supplemented with tracer gas emissions, easy to quantify. In the mobile tracer gas emission source, fig. 2, up to 50 kg propane per hour are diluted with up to 1 000 m3 air per hour. This blend is blown into the open atmosphere. The dilution device, including the fan, can be seperated from the trailer and mounted at any place, e.g. on top of a roof to simulate the exaust of a pig house or in the middle of a field to simulate undisturbed air flow. 2.2 TRANSMISSION For safety reasons, propane concentration at the source is always below the lower ignition concentration of 2,1 %. As the specific gravity of this emitted propane-air-blend is very close to that of pure air (difference less than 0,2%) and as flow parameters can be chosen in a wide range, we assume


2013 ◽  
Vol 1 (4) ◽  
pp. 3485-3527 ◽  
Author(s):  
H. Cammerer ◽  
A. H. Thieken ◽  
J. Lammel

Abstract. Flood loss modeling is an important component within flood risk assessments. Traditionally, stage-damage functions are used for the estimation of direct monetary damage to buildings. Although it is known that such functions are governed by large uncertainties, they are commonly applied – even in different geographical regions – without further validation, mainly due to the lack of data. Until now, little research has been done to investigate the applicability and transferability of such damage models to other regions. In this study, the last severe flood event in the Austrian Lech Valley in 2005 was simulated to test the performance of various damage functions for the residential sector. In addition to common stage-damage curves, new functions were derived from empirical flood loss data collected in the aftermath of recent flood events in the neighboring Germany. Furthermore, a multi-parameter flood loss model for the residential sector was adapted to the study area and also evaluated by official damage data. The analysis reveals that flood loss functions derived from related and homogenous regions perform considerably better than those from more heterogeneous datasets. To illustrate the effect of model choice on the resulting uncertainty of damage estimates, the current flood risk for residential areas was assessed. In case of extreme events like the 300 yr flood, for example, the range of losses to residential buildings between the highest and the lowest estimates amounts to a factor of 18, in contrast to properly validated models with a factor of 2.3. Even if the risk analysis is only performed for residential areas, more attention should be paid to flood loss assessments in future. To increase the reliability of damage modeling, more loss data for model development and validation are needed.


2018 ◽  
Vol 1 (2) ◽  
pp. 112
Author(s):  
Amat Rahmat ◽  
Eddy Prianto ◽  
Setia Budi Sasongko

Abstract: This research study discusses the phenomenon of fires that occur in several major cities in Indonesia in residential buildings in dense residential areas. In the case of this fire will be evaluated a variety of data on the cause of fire due to short circuit from electricity and record photos of objects typology of the form of residential roofs that burned around the location of the results of reports and documentation of publications media sources both newspapers and online media. Examples of cases of fire that were evaluated and discussed were taken from 2015 and 2018. Keyword: Roof Forms, Causes of Electricity, Homes Abstrak: Studi penelitian ini membahas tentang fenomena kebakaran yang terjadi di beberapa kota besar di Indonesia pada bangunan rumah tinggal yang ada di kawasan pemukiman padat. Pada kasus kebakaran ini akan dievaluasi berbagai data penyebab timbulnya api akibat hubungan arus pendek dari listrik dan merekam foto objek tipologi bentuk atap rumah tinggal yang terbakar di sekitar lokasi hasil dari laporan serta dokumentasi sumber media publikasi baik koran maupun media online. Contoh kasus kejadian kebakaran yang dievaluasi dan menjadi pembahasan diambil dari tahun 2015 sampai dengan bulan Juli 2018.    Kata Kunci: Bentuk Atap, Penyebab Listrik, Rumah Tinggal


Author(s):  
Marija Meišutovic-Akhtarieva ◽  
Eglė Marčiulaitienė

The article analyses the existing research on odour emissions from the passive odour source – municipal landfill for non-hazardous waste. The current research has been carried out in the Vilnius county, at the Kazokiškės landfill for regional municipal waste. Odour emissions were analysed using samples from waste of different age and at different outdoor air temperatures. The investigation determined the concentration of odourous volatile organic compounds (VOCs) formed in the landfill (mg/m3) and odour emissions (OUe/m2s). The odour concentration varied between 0.02 OUe/m2s (from 9 year old waste at 11oC) to 1.29 OUe/m2s (from 0–3 year old waste at minus 1 oC and minus 10 oC). It was determined that as temperature decreases (within the range of 11 to minus 10 oC), the concentration of odour emissions increases. The coefficient of correlation between the temperature of environment and the concentration of odours emitted from the landfill stood at minus 0.91.


2007 ◽  
Vol 111 (1119) ◽  
pp. 311-314 ◽  
Author(s):  
O. Dessens ◽  
H. L. Rogers ◽  
J. A. Pyle

Abstract New model calculations suggest that the potential impact on the atmosphere of a future fleet of supersonic aircraft, for the year 2015, is highly dependent upon the amount of nitrogen oxides (NO x ) emitted from the fleet. This result contrasts with the IPCC assessment which suggested that the impact of supersonic aircraft on the atmosphere was primarily through the role of water vapour emissions both on atmospheric ozone and climate change. These new findings are extremely important for atmospheric scientists, the aviation industry and policy makers, highlighting the importance of further development of low NO x combustors for supersonic aircraft, an aspect which has been largely ignored following the IPCC Special Report.


2016 ◽  
Vol 16 (11) ◽  
pp. 7117-7134 ◽  
Author(s):  
Miriam Elser ◽  
Carlo Bozzetti ◽  
Imad El-Haddad ◽  
Marek Maasikmets ◽  
Erik Teinemaa ◽  
...  

Abstract. Air pollution is one of the main environmental concerns in urban areas, where anthropogenic emissions strongly affect air quality. This work presents the first spatially resolved detailed characterization of PM2.5 (particulate matter with aerodynamic equivalent diameter daero  ≤  2.5 µm) in two major Estonian cities, Tallinn and Tartu. The measurements were performed in March 2014 using a mobile platform. In both cities, the non-refractory (NR)-PM2.5 was characterized by a high-resolution time-of-flight aerosol mass spectrometer (HR-ToF-AMS) using a recently developed lens which increases the transmission of super-micron particles. Equivalent black carbon (eBC) and several trace gases including carbon monoxide (CO), carbon dioxide (CO2), and methane (CH4) were also measured. The chemical composition of PM2.5 was found to be very similar in the two cities. Organic aerosol (OA) constituted the largest fraction, explaining on average about 52 to 60 % of the PM2.5 mass. Four sources of OA were identified using positive matrix factorization (PMF): hydrocarbon-like OA (HOA, from traffic emissions), biomass burning OA (BBOA, from biomass combustion), residential influenced OA (RIOA, probably mostly from cooking processes with possible contributions from waste and coal burning), and oxygenated OA (OOA, related to secondary aerosol formation). OOA was the major OA source during nighttime, explaining on average half of the OA mass, while during daytime mobile measurements the OA was affected by point sources and dominated by the primary fraction. A strong increase in the secondary organic and inorganic components was observed during periods with transport of air masses from northern Germany, while the primary local emissions accumulated during periods with temperature inversions. Mobile measurements offered the identification of different source regions within the urban areas and the assessment of the extent to which pollutants concentrations exceeded regional background levels (urban increments). HOA, eBC, CO2, and CO showed stronger enhancements on busy roads during the morning and evening traffic rush hours; BBOA had its maximum enhancement in the residential areas during the evening hours and RIOA was enhanced in both the city center (emissions from restaurants) and in the residential areas (emissions from residential cooking). In contrast, secondary components (OOA, sulfate (SO4), nitrate (NO3), ammonium (NH4), and chloride (Cl)) had very homogeneous distributions in time and space. We were able to determine a total PM2.5 urban increment in Tartu of 6.0 µg m−3 over a regional background concentration of 4.0 µg m−3 (i.e., a factor of 2.5 increase). Traffic exhaust emissions were identified as the most important source of this increase, with eBC and HOA explaining on average 53.3 and 20.5 % of the total increment, respectively.


Sign in / Sign up

Export Citation Format

Share Document