scholarly journals Corrosion Behavior of Some Timonb Alloys in Ringer Solution

2020 ◽  
Vol 71 (7) ◽  
pp. 187-196
Author(s):  
Maria Magdalena Pricopi ◽  
Romeu Chelariu ◽  
Nicolae Apostolescu ◽  
Doina-Margareta Gordin ◽  
Daniel Sutiman ◽  
...  

The aim of this study was to investigate the influence of different process parameters as chemical composition, the pH value and immersion time on the corrosion of the some TiMoNb alloys, using different electrochemical techniques such as: cyclic voltammetry, open circuit potential (OCP) measurement, polarization curves and electrochemical impedance spectroscopy (EIS). The alloys were analyzed in the natural pH of the Ringer solution, but also with an acidic modification of the solution (ph = 4) and a basic modification (ph = 8). The more acidic values of pH, the more evident are differences between corrosion behavior of titanium-based alloys depending on their chemical compositions and immersion times.

2012 ◽  
Vol 2012 ◽  
pp. 1-9 ◽  
Author(s):  
A. Torres-Islas ◽  
C. Carachure ◽  
S. Serna ◽  
B. Campillo ◽  
G. Rosas

The corrosion behavior of the Fe40Al60nanostructured intermetallic composition was studied using electrochemical impedance spectroscopy (EIS) and linear polarization resistance (LPR) techniques with an innovative electrochemical cell arrangement. The Fe40Al60(% at) intermetallic composition was obtained by mechanical alloying using elemental powders of Fe (99.99%) and Al (99.99%). All electrochemical testing was carried out in Fe40Al60particles that were in water with different pH values. Temperature and test time were also varied. The experimental data was analyzed as an indicator of the monitoring of the particle corrosion current densityicorr. Different oxide types that were formed at surface particle were found. These oxides promote two types of surface corrosion mechanisms: (i) diffusion and (ii) charge transfer mechanisms, which are a function oficorrbehavior of the solution, pH, temperature, and test time. The intermetallic was characterized before and after each test by transmission electron microscopy. Furthermore, the results show that at the surface particles uniform corrosion takes place. These results confirm that it is possible to sense the nanoparticle corrosion behavior by EIS and LPR conventional electrochemical techniques.


CORROSION ◽  
10.5006/0709 ◽  
2013 ◽  
Vol 69 (6) ◽  
pp. 543-550 ◽  
Author(s):  
S. Jones ◽  
K. Coley ◽  
J. Kish

When exposed to concentrated sulfuric acid, stainless steel exhibits unique electrochemical behavior. This behavior can be observed as an oscillation in open-circuit potential between the active and passive states. The transient nature of the corrosion behavior under these conditions results in a distinct challenge for measuring and predicting corrosion rates. Using a series of commercial alloys with various nickel contents, this paper outlines the utilization of electrochemical experimentation to refine the prediction of corrosion rates. The paper also discusses some of the difficulties associated with many traditional electrochemical techniques such as potentiodynamic scans when used for characterizing systems that undergo oscillations in open-circuit potential.


2016 ◽  
Vol 835 ◽  
pp. 131-135 ◽  
Author(s):  
Francis Mulimbayan ◽  
Manolo G. Mena

Stainless steel (SS) is one of the most commonly used metallic food contact materials. It may be classified based on its microstructure whether ferritic, austenitic, martensitic, duplex or precipitation hardened. Austenitic SS, among mentioned grades, has the largest contribution to market due to its numerous industrial and domestic applications. In this study, the corrosion behavior of AISI 202 SS – a cheaper grade of stainless steel, in three different solution temperatures of citric acid was investigated using different electrochemical techniques such as open-circuit potential (OCP) measurements, potentiodynamic polarization and electrochemical impedance spectroscopy (EIS). The results were compared to that obtained from conventional AISI 304 SS. OCP, polarization and impedance measurements agreed that AISI 202 SS has comparable resistance to that of AISI 304 SS in citric acid at ambient temperature and at 50 °C. At 70 °C, results of OCP measurements suggest that AISI 304 SS exhibited greater performance as indicated by more positive OCP values in the designated solution. EIS results indicate that the two alloys have identical corrosion resistance even at 70 °C as indicated by their comparable polarization resistance (Rp). The corrosion mechanism in both alloys is charge-transfer controlled as indicated by depressed semi-circular appearance of the generated Nyquist plots. The values of corrosion current densities (icorr) extracted from polarization curves indicate that the initial corrosion rates were higher in AISI 304 than AISI 202 SS suggesting that formation of more protective film may have occurred on the former alloy.


2016 ◽  
Vol 835 ◽  
pp. 115-120
Author(s):  
Francis Mulimbayan ◽  
Manolo G. Mena

All materials which are intended to have in contact with food and other commodities produced or processed for human consumption are called food contact materials (FCM’s). Stainless steel (SS) – a widely known metallic FCM is used mainly in processing equipment, containers and household utensils. It is known for having numerous industrial and domestic applications worldwide due to its special characteristics of having notable corrosion resistance. However, this corrosion resistance is not all-encompassing since SS may still undergo degradation when subjected to a specific corrosion-inducing environment. SS may be classified according to its microstructure. If the atoms which make up the SS can be viewed as having a face-centered cubic structure, then the alloy is said to be austenitic. This SS grades include the conventional 300-series and the newly-developed 200-series. The former has superior corrosion resistance while the latter is far cheaper. In this study, the corrosion behavior of AISI 202 SS in two different levels of dissolved oxygen (O2) and three acid concentrations was investigated using electrochemical techniques, namely, open-circuit potential (OCP) measurements and electrochemical impedance spectroscopy (EIS). As the concentration of citric acid is increased, the measured OCP values of the alloy decreased and the polarization resistance (Rp) decreased, indicating decrease in alloy stability and decline in the corrosion resistance, respectively. With regards to effects of dissolved O2, results revealed that increasing the level of dissolved O2 has consequently increased the polarization resistance and shifted the OCP to more positive values. All the generated Nyquist plots exhibited a depressed capacitive loops indicating that corrosion in the designated solution occurred with charge transfer as the rate-determining step.


2021 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Carmen Marina Garcia-Falcon ◽  
Tomas Gil-Lopez ◽  
Amparo Verdu-Vazquez ◽  
Julia Claudia Mirza-Rosca

Purpose This paper aims to analyze the corrosion behavior in Ringer solution of six commercially used Ni-based alloys that are present and commonly used as metallic biomaterials. Design/methodology/approach The specimens were received in the form of cylindrical ingots and were cut to get five samples of each brand with a cylindrical shape of 2 mm height to conduct the study. In this scientific research, the following techniques were used: open circuit potential, potentiodynamic polarization studies, and electrochemical impedance spectroscopy. Findings The study findings revealed the passivation tendency of the different specimens. Additionally, when the materials were compared, it was discovered that the decisive factor for high corrosion resistance was the chromium concentration. However, with similar chromium content, the stronger concentration in molybdenum increased the resistance. According to the results obtained in this investigation, the biological safety of the dental materials studied in Ringer solution was considered very high for specimens 1 and 2, and adequate for the other samples. Originality/value Metal alloys used as biomaterials in contact with the human body should be deeply investigated to make sure they are biocompatible and do not cause any harm. The corrosion resistance of an alloy is the most important characteristic for its biological safety, as all problems arise because of the corrosion process. There is scarce investigation in these Ni-based dental biomaterials, and none found in these commercially used dental materials in Ringer solution.


Minerals ◽  
2019 ◽  
Vol 9 (3) ◽  
pp. 169 ◽  
Author(s):  
Jia-Ning Xu ◽  
Wen-Ge Shi ◽  
Peng-Cheng Ma ◽  
Liang-Shan Lu ◽  
Gui-Min Chen ◽  
...  

In this paper, the galvanic effect of pyrite and arsenopyrite during the leaching pretreatment of gold ores was determined with the use of electrochemical testing (open circuit potential, linear sweep voltammetry, Tafel, and electrochemical impedance spectroscopy (EIS)) and frontier orbit calculations. The results show that (i) the linear sweep voltammetry curve and Tafel curve of the galvanic pair are similar to those of arsenopyrite, (ii) the corrosion behavior of the galvanic pair is consistent with that of arsenopyrite, and (iii) the galvanic effect promotes the corrosion of arsenopyrite by simultaneously increasing the cathode and anode currents and reducing oxidation resistance. The frontier orbit calculation explains the principle of the galvanic effect of pyrite and arsenopyrite from the view of quantum mechanics.


2018 ◽  
Vol 2018 ◽  
pp. 1-15 ◽  
Author(s):  
D. M. Martinez de la Escalera ◽  
J. J. Ramos-Hernandez ◽  
E. Porcayo-Palafox ◽  
J. Porcayo-Calderon ◽  
J. G. Gonzalez-Rodriguez ◽  
...  

In this study, the effect of the addition of Nd3+ ions as a corrosion inhibitor of the API X70 steel in a medium rich in chlorides was evaluated. The performance of the Nd3+ ions was evaluated by means of electrochemical techniques such as potentiodynamic polarization curves, open circuit potential measurements, linear polarization resistance, and electrochemical impedance spectroscopy, as well as by means of scanning electron microscopy and EDS measurements. The results showed that Nd3+ ions reduce the corrosion rate of steel at concentrations as low as 0.001 M Nd3+. At higher concentrations, the inhibition efficiency was only slightly affected although the concentration of chloride ions was increased by the addition of the inhibitor. The adsorption of the Nd3+ ions promotes the formation of a protective layer of oxides/hydroxides on the metal surface, thereby reducing the exchange rate of electrons. Nd3+ ions act as a mixed inhibitor with a strong predominant cathodic effect.


Author(s):  
Mohandoss S ◽  
◽  
Srinivasan S.P. ◽  

Development of biocompatible dental implants has become significant impact in dental industry. In the present work, we report for the development of biocompatible nano Yttria stabilised Zirconia (YSZ) coatings on 316L stainless steel (316L SS) obtained by EPD process. The optimized sample (nano YSZ coating on 316 obtained at applied potential of 70 V for 5 minutes) were sintered in air at 600, 800 and 900°C. The surface morphology and composition of the coatings were characterized by XRD and FE-SEM with EDAX. The electrochemical performance of the uncoated metal and nano YSZ coated 316L SS samples were evaluated in artificial saliva (AS) medium using electrochemical techniques such as Open Circuit Potential – time measurement (OCP), Electrochemical Impedance Spectroscopy (EIS) and Cyclic Potentiodynamic Polarization (CPP).


2018 ◽  
Vol 2018 ◽  
pp. 1-10 ◽  
Author(s):  
Van T. H. Vu ◽  
Thanh T. M. Dinh ◽  
Nam T. Pham ◽  
Thom. T. Nguyen ◽  
Phuong T. Nguyen ◽  
...  

Silica/Polypyrrole nanocomposites (SiO2/PPy) incorporating oxalate as counter anion (SiO2/PPyOx) were chemically polymerized in the solution with the presence of pyrrole, silica, and sodium oxalate. Nanocomposites SiO2/PPyOx at different concentrations of oxalate anion were characterized with FTIR, XRD, EDX, TGA, and TEM. The corrosion protective properties for carbon steel of nanocomposites in epoxy coating were studied by electrochemical techniques including electrochemical impedance spectroscopy (EIS) and open circuit potential (OCP). FTIR results of nanocomposites show a slightly red-shift in terms of wavelength compared with the case of PPy and SiO2 spectra. It may be due to a better conjugation and interactions between PPy and SiO2 in nanocomposite structure. TEM image indicated that nanocomposites have spherical morphologies with diameters between 100 and 150 nm. The EIS results showed that |Z| modulus values of epoxy coatings containing SiO2/PPyOx composites reached about 109.7 Ω.cm2, always higher than that of epoxy coating. These results are also confirmed by OCP results. It proves that the presence of oxalate anion can enhance the resistance against corrosion and it has been shown that the content of counter anion strongly affects the anticorrosion ability.


2011 ◽  
Vol 686 ◽  
pp. 21-25
Author(s):  
Xian Long Cao ◽  
Fu Sheng Pan ◽  
Hong Da Deng ◽  
Wei Cai

This present work investigated the corrosion behavior of AZ31 magnesium alloy substrates pre-treated with bis-[triethoxysilylpropyl] tetrasulfide silane modified with cerium nitrate. The corrosion behavior of the pre-treated substrates in 0.005M sodium chloride solutions was assessed by potentiodynamic polarization, open circuit potential and electrochemical impedance spectroscopy (EIS). The results showed that the silane pre-treatments improved the corrosion resistance of the AZ31 magnesium alloy substrates in the presence of chloride ions. Especially the addition of cerium nitrate played an important role in reducing the corrosion activity.


Sign in / Sign up

Export Citation Format

Share Document