scholarly journals Investigations of sintering temperature and cell viability of biocompatible nano Yttria stabilised zirconia coated on 316L SS for dental applications

Author(s):  
Mohandoss S ◽  
◽  
Srinivasan S.P. ◽  

Development of biocompatible dental implants has become significant impact in dental industry. In the present work, we report for the development of biocompatible nano Yttria stabilised Zirconia (YSZ) coatings on 316L stainless steel (316L SS) obtained by EPD process. The optimized sample (nano YSZ coating on 316 obtained at applied potential of 70 V for 5 minutes) were sintered in air at 600, 800 and 900°C. The surface morphology and composition of the coatings were characterized by XRD and FE-SEM with EDAX. The electrochemical performance of the uncoated metal and nano YSZ coated 316L SS samples were evaluated in artificial saliva (AS) medium using electrochemical techniques such as Open Circuit Potential – time measurement (OCP), Electrochemical Impedance Spectroscopy (EIS) and Cyclic Potentiodynamic Polarization (CPP).

Coatings ◽  
2018 ◽  
Vol 8 (12) ◽  
pp. 454 ◽  
Author(s):  
Arman Dastpak ◽  
Kirsi Yliniemi ◽  
Mariana de Oliveira Monteiro ◽  
Sarah Höhn ◽  
Sannakaisa Virtanen ◽  
...  

In this study, a waste of biorefinery—lignin—is investigated as an anticorrosion coating on stainless steel. Corrosion behavior of two lignin types (hardwood beech and softwood spruce) was studied by electrochemical measurements (linear sweep voltammetry, open circuit potential, potentiostatic polarization, cyclic potentiodynamic polarization, and electrochemical impedance measurements) during exposure to simulated body fluid (SBF) or phosphate buffer (PBS). Results from linear sweep voltammetry of lignin-coated samples, in particular, demonstrated a reduction in corrosion current density between 1 and 3 orders of magnitude cf. blank stainless steel. Furthermore, results from cross cut adhesion tests on lignin-coated samples demonstrated that the best possible adhesion (grade 0) of ISO 2409 standard was achieved for the investigated novel coatings. Such findings suggest that lignin materials could transform the field of organic coatings towards more sustainable alternatives by replacing non-renewable polymer coatings.


2020 ◽  
Vol 835 ◽  
pp. 288-296 ◽  
Author(s):  
Adel Attia ◽  
Lobna A. Khorshed ◽  
Lamiaa Z. Mohamed ◽  
Mohammed A. Gepreel

Ti-Mn alloy has a high specific strength, excellent cold workability and good biocompatibility. A cold rolled Ti-7 wt.% Mn was compared to annealed sample at 900°C for 10 min and the corrosion resistance property was tested in artificial saliva solution (AS). The Ti-7 wt.% Mn alloys (cold rolled and annealed) were characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), Energy dispersive X-ray analysis (EDX) and compared to pure Ti. Simultaneously, the alloys tested in the AS solution for up to 28 days mainly by following the open-circuit potential (OCP), electrochemical impedance spectroscopy (EIS), SEM and EDX. Annealed Ti-7wt.% Mn showed good corrosion properties similar to that of pure Ti, hence the new Ti-7wt.%Mn alloy have higher specific strength than pure Ti, yet showed same corrosion properties which favor implanted dental applications.


2012 ◽  
Vol 23 (2) ◽  
pp. 141-148 ◽  
Author(s):  
Rodrigo Galo ◽  
Ricardo Faria Ribeiro ◽  
Renata Cristina Silveira Rodrigues ◽  
Luís Augusto Rocha ◽  
Maria da Glória Chiarello de Mattos

The aim of this study was to determine the effect of the oral environment on the corrosion of dental alloys with different compositions, using electrochemical methods. The corrosion rates were obtained from the current-potential curves and electrochemical impedance spectroscopy (EIS). The effect of artificial saliva on the corrosion of dental alloys was dependent on alloy composition. Dissolution of the ions occurred in all tested dental alloys and the results were strongly dependent on the general alloy composition. Regarding the alloys containing nickel, the Ni-Cr and Ni-Cr-Ti alloys released 0.62 mg/L of Ni on average, while the Co-Cr dental alloy released ions between 0.01 and 0.03 mg/L of Co and Cr, respectively.The open-circuit potential stabilized at a higher level with lower deviation (standard deviation: Ni-Cr-6Ti = 32 mV/SCE and Co-Cr = 54 mV/SCE). The potenciodynamic curves of the dental alloys showed that the Ni-based dental alloy with >70 wt% of Ni had a similar curve and the Co-Cr dental alloy showed a low current density and hence a high resistance to corrosion compared with the Ni-based dental alloys. Some changes in microstructure were observed and this fact influenced the corrosion behavior for the alloys. The lower corrosion resistance also led to greater release of nickel ions to the medium. The quantity of Co ions released from the Co-Cr-Mo alloy was relatively small in the solutions. In addition, the quantity of Cr ions released into the artificial saliva from the Co-Cr alloy was lower than Cr release from the Ni-based dental alloys.


2008 ◽  
Vol 59 (9) ◽  
Author(s):  
Daniel Mareci ◽  
Igor Cretescu ◽  
Neculai Aelenei ◽  
Julia Claudia Mirza Rosca

The electrochemical behavior of a three Ag-Pd alloys used in dental prosthetics construction for crowns and bridges was studied in artificial saliva using the polarization curves and electrochemical impedance spectroscopy (EIS). The corrosion resistance was evaluated by means of the corrosion currents value and by coulometric analysis. The open circuit potential of Ag-Pd are attributed to dealloying followed by surface enrichment with Ag and the possible formation of an insoluble AgCl surface film on the respective alloy surfaces. Our results have shown that these alloys have a somewhat good corrosion resistance in artificial saliva. When increasing the content of Cu, corrosion resistance decreases. The passivation of all samples occurred spontaneously at the open circuit potential. The electrochemical properties of the spontaneously passivated electrodes at the open circuit potential were studied by EIS. The polarization resistance (Rp) and the electrode capacitance (Cdl) were determined. The polarisation resistance of all the samples increases with the immersion time. The polarization resistances are largest and decrease when increasing the content of Cu. Cu reduces the Ag-Pd alloy corrosion resistance. The present study, thought limited, has shown that electrochemical characteristics can be use to identify such alloys. Knowledge of the in vitro corrosion behaviour of these alloys may lead to better understanding of any biologically adverse effects in vitro.


2015 ◽  
Vol 2015 ◽  
pp. 1-14 ◽  
Author(s):  
J. Porcayo-Calderon ◽  
M. Casales-Diaz ◽  
V. M. Salinas-Bravo ◽  
L. Martinez-Gomez

Several austenitic stainless steels suitable for high temperature applications because of their high corrosion resistance and excellent mechanical properties were investigated as biomaterials for dental use. The steels were evaluated by electrochemical techniques such as potentiodynamic polarization curves, cyclic polarization curves, measurements of open circuit potential, and linear polarization resistance. The performance of steels was evaluated in two types of environments: artificial saliva and mouthwash solution at 37°C for 48 hours. In order to compare the behavior of steels, titanium a material commonly used in dental applications was also tested in the same conditions. Results show that tested steels have characteristics that may make them attractive as biomaterials for dental applications. Contents of Cr, Ni, and other minor alloying elements (Mo, Ti, and Nb) determine the performance of stainless steels. In artificial saliva steels show a corrosion rate of the same order of magnitude as titanium and in mouthwash have greater corrosion resistance than titanium.


2018 ◽  
Vol 2018 ◽  
pp. 1-15 ◽  
Author(s):  
D. M. Martinez de la Escalera ◽  
J. J. Ramos-Hernandez ◽  
E. Porcayo-Palafox ◽  
J. Porcayo-Calderon ◽  
J. G. Gonzalez-Rodriguez ◽  
...  

In this study, the effect of the addition of Nd3+ ions as a corrosion inhibitor of the API X70 steel in a medium rich in chlorides was evaluated. The performance of the Nd3+ ions was evaluated by means of electrochemical techniques such as potentiodynamic polarization curves, open circuit potential measurements, linear polarization resistance, and electrochemical impedance spectroscopy, as well as by means of scanning electron microscopy and EDS measurements. The results showed that Nd3+ ions reduce the corrosion rate of steel at concentrations as low as 0.001 M Nd3+. At higher concentrations, the inhibition efficiency was only slightly affected although the concentration of chloride ions was increased by the addition of the inhibitor. The adsorption of the Nd3+ ions promotes the formation of a protective layer of oxides/hydroxides on the metal surface, thereby reducing the exchange rate of electrons. Nd3+ ions act as a mixed inhibitor with a strong predominant cathodic effect.


2018 ◽  
Vol 2018 ◽  
pp. 1-10 ◽  
Author(s):  
Van T. H. Vu ◽  
Thanh T. M. Dinh ◽  
Nam T. Pham ◽  
Thom. T. Nguyen ◽  
Phuong T. Nguyen ◽  
...  

Silica/Polypyrrole nanocomposites (SiO2/PPy) incorporating oxalate as counter anion (SiO2/PPyOx) were chemically polymerized in the solution with the presence of pyrrole, silica, and sodium oxalate. Nanocomposites SiO2/PPyOx at different concentrations of oxalate anion were characterized with FTIR, XRD, EDX, TGA, and TEM. The corrosion protective properties for carbon steel of nanocomposites in epoxy coating were studied by electrochemical techniques including electrochemical impedance spectroscopy (EIS) and open circuit potential (OCP). FTIR results of nanocomposites show a slightly red-shift in terms of wavelength compared with the case of PPy and SiO2 spectra. It may be due to a better conjugation and interactions between PPy and SiO2 in nanocomposite structure. TEM image indicated that nanocomposites have spherical morphologies with diameters between 100 and 150 nm. The EIS results showed that |Z| modulus values of epoxy coatings containing SiO2/PPyOx composites reached about 109.7 Ω.cm2, always higher than that of epoxy coating. These results are also confirmed by OCP results. It proves that the presence of oxalate anion can enhance the resistance against corrosion and it has been shown that the content of counter anion strongly affects the anticorrosion ability.


2020 ◽  
Vol 71 (7) ◽  
pp. 187-196
Author(s):  
Maria Magdalena Pricopi ◽  
Romeu Chelariu ◽  
Nicolae Apostolescu ◽  
Doina-Margareta Gordin ◽  
Daniel Sutiman ◽  
...  

The aim of this study was to investigate the influence of different process parameters as chemical composition, the pH value and immersion time on the corrosion of the some TiMoNb alloys, using different electrochemical techniques such as: cyclic voltammetry, open circuit potential (OCP) measurement, polarization curves and electrochemical impedance spectroscopy (EIS). The alloys were analyzed in the natural pH of the Ringer solution, but also with an acidic modification of the solution (ph = 4) and a basic modification (ph = 8). The more acidic values of pH, the more evident are differences between corrosion behavior of titanium-based alloys depending on their chemical compositions and immersion times.


2014 ◽  
Vol 2014 ◽  
pp. 1-10 ◽  
Author(s):  
Santos Lorenzo Chi-Ucán ◽  
Andrea Castillo-Atoche ◽  
Pedro Castro Borges ◽  
José Antonio Manzanilla-Cano ◽  
Gerardo González-García ◽  
...  

The inhibitory effect of glycerol on copper corrosion in aerated NaCl (0.5 M) solutions at three pH values (4, 7, and 10) was evaluated. Inhibition efficiency was assessed with conventional electrochemical techniques: open circuit potential, potentiodynamic polarization, and electrochemical impedance analysis. Glycerol reduced the corrosion rate of copper in NaCl solutions. The best inhibition effect (η≈83%) was produced in alkaline (pH 10) chloride media. This effect can be ascribed to increased viscosity and the presence of copper-glycerol complexes.


2021 ◽  
Vol 12 (1) ◽  
pp. 12
Author(s):  
Patrycja Osak ◽  
Joanna Maszybrocka ◽  
Julian Kubisztal ◽  
Patryk Ratajczak ◽  
Bożena Łosiewicz

Calcium phosphate coatings are able to improve the osseointegration process due to their chemical composition, which is similar to that of bone tissues. In this work, to increase the long-term corrosion resistance and to improve the osseointegration process of commercially pure titanium Grade 4 (CpTi G4), biomimetic amorphous calcium phosphate (ACP) coatings were electrodeposited for the first time from an acetate bath with a pH level of 7.0 and a Ca:P ratio of 1.67. ACP coatings were obtained on CpTi G4 substrate subjected to sandblasting and autoclaving using electrochemically assisted deposition at a potential of −3 V relative to the open circuit potential for 30 min at room temperature. SEM, EDS, 2D roughness profiles, amplitude-sensitive eddy current method, and Kelvin scanning probe were used for the surface characterization of the biomaterial under study. In vitro corrosion resistance tests were conducted for 21 days in artificial saliva using open circuit potential, polarization curves, and electrochemical impedance spectroscopy measurements. The passive-transpassive behavior was revealed for the obtained ACP coatings. The long-term corrosion resistance test showed a deterioration of the protective properties for CpTi G4 uncoated and coated with ACP with immersion time. The mechanism and kinetics of the pitting corrosion on the CpTi G4|TiO2|ACP coating system are discussed in detail.


Sign in / Sign up

Export Citation Format

Share Document