Water Quality Analysis on Haizhou Bay Water Area of China Using the PPCM-PCAM Method

2012 ◽  
Vol 554-556 ◽  
pp. 2116-2119
Author(s):  
Ben Lin Dai ◽  
Fei Hu Mu ◽  
Ning Xu

The offshore region of Haizhou Bay is characterized by intense anthropogenic activities. And the study on water quality status analysis in this offshore region has attracted more and more attention of the researchers and decision-makers. In this paper, an improved method (the PPCM-PCAM) which combines projection pursuit cluster model (PPCM) with principal component analysis method (PCAM) was developed to analysis water quality status. By using this improved method, water quality analysis of Haizhou Bay water area from January 2007 to December 2007 was studied. The analysis results show that the samples in Haizhou Bay water area can be described into 4 "category 1”, 4 “category 2” and 2 “category 3” states in 2007.

2011 ◽  
Vol 204-210 ◽  
pp. 1467-1471
Author(s):  
Ben Lin Dai ◽  
Zu Lin Hua ◽  
Xu Hua Yu ◽  
Xiao Hui Jiang ◽  
Ke Jian Chu ◽  
...  

The offshore region of Haizhou Bay is characterized by intense anthropogenic activities. And the study on comparative analysis of water quality status in this offshore region has attracted more and more attention of the researchers and decision-makers. In this paper, comparative analysis on water quality status of different samples in Haizhou Bay during May 10-21, 2007 was studied by principal component analysis method (PCAM). The water quality status in Haizhou Bay was compared and analyzed by using 13 samples, with DO, SS, Active Phosphate and Petroleum impact factors. Based on the PCAM analysis procedures, the comparative analysis results of water quality state in Haizhou Bay show that the spatial order from good to bad is determined as follows: JS03> JS01> JS04> JS07> JS02> JS09> JS05> JS06> JS13> JS10> JS12> JS08> JS11.


Water Policy ◽  
2021 ◽  
Author(s):  
A. Alamanos

Abstract Every bathing season in Ireland several bathing sites are closing and receiving warnings against bathing. In this report, their water quality status is assessed, and the broader picture of each case is investigated. A database is formed including location-maps, the restrictions they were/are subject to, the official justification, past and current annual water quality status, (sub)catchment where they are located, main water bodies flowing in, the closest WasteWater Treatment Plants with their characteristics and performance based on EU treatment standards, the closest meteorological stations and the rainfall data related with stormwater overflow events (correlation analyses) and the surrounding land cover. For each case, possible causes were discussed; the actions so far and the relevant literature are analyzed to provide key policy recommendations which are useful for the review of the European Bathing Water Directive.


2020 ◽  
Vol 211 ◽  
pp. 03008
Author(s):  
Sinta Ramadhania Putri Maresi ◽  
Tri Edhi Budhi Soesilo ◽  
Ami Aminah Meutia

Urban lakes are experiencing various kinds of problems because of the anthropocentrism of environmental management. This also happens in Situ Gintung, Indonesia. This lake is polluted by many pollutants from urban activities, such as the entry of domestic waste into waters due to anthropogenic activities and the amount of leftover food not consumed by fisheries. These problems can be solved by observing the water quality of Situ Gintung to provide information about parameters that have exceeded environmental quality standards and provide general information about the water quality in the dry season from 2017 to 2020. The research is done using a purposive sampling method and determining water quality status with the STORET method based on the Indonesian standard with parameters less than ten. As a result, Situ Gintung water is neither classified as class I, II, III, and IV nor be utilized for consumption, recreation, fisheries, and irrigation because the quality status is mostly in the heavily polluted category. Furthermore, the three highest polluters from each class are BOD5, COD, and a total of Coliform.


2017 ◽  
Vol 2017 ◽  
pp. 1-18 ◽  
Author(s):  
M. K. Daud ◽  
Muhammad Nafees ◽  
Shafaqat Ali ◽  
Muhammad Rizwan ◽  
Raees Ahmad Bajwa ◽  
...  

Due to alarming increase in population and rapid industrialization, drinking water quality is being deteriorated day by day in Pakistan. This review sums up the outcomes of various research studies conducted for drinking water quality status of different areas of Pakistan by taking into account the physicochemical properties of drinking water as well as the presence of various pathogenic microorganisms. About 20% of the whole population of Pakistan has access to safe drinking water. The remaining 80% of population is forced to use unsafe drinking water due to the scarcity of safe and healthy drinking water sources. The primary source of contamination is sewerage (fecal) which is extensively discharged into drinking water system supplies. Secondary source of pollution is the disposal of toxic chemicals from industrial effluents, pesticides, and fertilizers from agriculture sources into the water bodies. Anthropogenic activities cause waterborne diseases that constitute about 80% of all diseases and are responsible for 33% of deaths. This review highlights the drinking water quality, contamination sources, sanitation situation, and effects of unsafe drinking water on humans. There is immediate need to take protective measures and treatment technologies to overcome unhygienic condition of drinking water supplies in different areas of Pakistan.


2020 ◽  
Vol 18 (1) ◽  
pp. 32-49
Author(s):  
GRACE OLUWASANYA ◽  
ADEBAYO SADIQ

The quest for safe drinking-water is very high in the ongoing period of environmental pollution. Generally, anthropogenic activities resulting from increasing population and urbanization are major sources of pollution to groundwater. This paper assesses the variation in groundwater distribution in Abeokuta city, Ogun State, Nigeria to determine the water quality status. Secondary groundwater quality data across a period of fifteen years (2001 – 2015) were retrieved from the database of the Department of Water Resources Management and Agro-meteorology, Federal University of Agriculture, Abeokuta, Nigeria to establish the status and examine the spatial and temporal variation. The data was subjected to statistical and geo-statistical analysis. Results showed that temperature, pH and electrical conductivity have a dominant range of 28.0 – 29.9 ºC, 7.01 – 7.50 and 201 – 600 µS/cm, respectively. The major cations Ca2+, Mg2+, Na+ and K+ have respective dominant concentration range from below detection limit (bdl) – 80mg/L, bdl – 30mg/L, 11 – 20 mg/L and bdl – 10 mg/L, while the major anions Cl-, HCO3-, NO3- and SO42- have respective dominant concentration range of 11 – 30, 101 – 200, 1.60 – 4.00 and bdl – 10 mg/L. High (> 1000 µS/cm) conductivity values are detected in parts of the city, which may be due to high concentrations of magnesium, calcium, potassium, chloride and bicarbonate. Only few parts (5.7%) of the city have poor water quality status, while groundwater quality in about 45.7% and 48.6 % of the city may be classified as good and excellent water quality, respectively. The spatial trend showed that groundwater in the core townships of Abeokuta such as Itoku and the environs should not be encouraged for direct consumption without prior treatment. But generally, the groundwater in most part of Abeokuta metropolis is safe for domestic use, though requires some form of household treatment before drinking.    


2012 ◽  
Vol 3 (4) ◽  
pp. 75-77
Author(s):  
Prof. A.B. More Prof. A.B. More ◽  
◽  
Prof. C.S. Chavan Prof. C.S. Chavan ◽  
Ajoy Gurung ◽  
Pramod Sarwade ◽  
...  

2018 ◽  
Vol 5 (2) ◽  
Author(s):  
Ratu Siti Aliah

An evaluation of the water quality at the hatchery of Tanjung Riau was conducted to understand the water quality status at the several place of the hatchery unit such as brood stock tanks, larva rearing tank, water storage tank, fi ngerling tank as well as the source of the water supply. The water quality status of Tanjung Riau generally is in a good condition to support the hatchery activities, but for turbidity and salinity were in the exceed and below the normal status and its infl uence on the spawning activity. To overcome the problem on the spawning of the brood stock, the improving of water supply with higher salinity and low turbidity should be set up to ensure the succeeded of the spawning.Key words : Water quality, grouper brood stock, hatchery,Tanjung Riau Batam


2017 ◽  
Vol 13 (2) ◽  
pp. 111-119
Author(s):  
Lela Uyara ◽  
Pieter Kunu ◽  
Silwanus M Talakua

The study aims to determine the quality of clean water in the villages of Wainitu, Batumerah, Amahusu and Halong by comparing the result of water quality analysis with water quality standard. Water quality analysis includes Physiscal, Chemical, and Microbiological parameters. This research uses descriptive method, this method describes systematics, accurate about facts and characteristic of the quality of clean water of each research location. The results showed that the source of clean water in the village of Batumerah did not meet the standard of clean water quality standards indicated by the number of E. coli and the high total coliform.  Keywords: standard quality of clean water, water quality, Wainitu, Batumerah, Amahusu and Halong villages   ABSTRAK Penelitian yang bertujuan untuk menetapkan kualitas air bersih di Desa Wainitu, Batumerah, Amahusu dan Halong, dengan membandingkan hasil analisis kualitas air dengan standar baku mutu air bersih. Analisis kualitas air meliputi parameter fisika, kimia dan mikrobiologi. Penelitian ini menggunakan metode deskriptif; metode ini menggambarkan sicara sistematis, akurat, fakta dan karakteristik mengenai kualitas air bersih di masing-masing lokasi penelitian. Hasil penelitian menunjukkan bahwa sumber air bersih di Desa Batumerah tidak memenuhi standar baku mutu air bersih yang ditunjukkan oleh jumlah E. coli dan total Koliform yang tinggi. Kata Kunci: baku mutu air bersih, Desa Wainitu, Batumerah, Amahusu dan Halong, kualitas air


Author(s):  
Markus T Lasut ◽  
Adianse Tarigan

A study on water quality status of three riverine systems, S. Bailang (SB), S. Maasing (SM), and S. Tondano (ST), in coastal city of Manado, North Sulawesi Province, has been conducted to measure several water quality parameters, to analyse source and quality of wastewater discharge, and to assess the status of the rivers related to the water quality. Measurement of the parameters was conducted using three indicators, i.e. organic (BOD5) and in-organic (N-NO3 and P-PO4), and pathogenic microorganism (Escherichia coli [EC] and total coliform [TC]). The result showed that the level of water quality varied between the rivers. The average level of water quality (based on the observed parameters) in SB, respectively, was 0.317 mg/l, 0.093 mg/l, 2 mg/l, >2420 MPN, and  >2420 MPN; in SM, respectively, was 0.029 mg/l, 1.859 mg/l, 17.7 mg/l, >2420 MPN, and >2420 MPN; and in ST, respectively, was 0.299 mg/l, 0.252 mg/l, 3.5 mg/l, >2420 MPN, and >2420 MPN. The level of water quality between the rivers was not significantly different (p>0.05), except based on the parameter of N-NO3 which was significantly different (p<0.01). The status of the observed rivers varied based on the classes of their water utilities (according to the Government Regulation of Indonesia, No. 82, 2001); mostly was "unsuitable". Kajian tentang status kualitas air di 3 perairan sungai di kota pesisir Manado, S. Bailang (SB), S. Maasing (SM), dan S. Tondano (ST), Provinsi Sulawesi Utara, telah dilakukan yang bertujuan untuk mengukur beberapa parameter kualitas air, menganalisis sumber dan kualitas buangan limbah domestik, dan menilai status ketiga perairan sungai tersebut. Tiga indikator digunakan, yaitu: bahan organik (BOD5), bahan anorganik (N-NO3 dan P-PO4), dan mikroorganisme patogenik (Escherichia coli [EC] dan coliform total [TC]). Hasil kajian menunjukkan bahwa tingkat kualitas air perairan tersebut berbeda-beda. Konsentrasi rerata parameter kualitas air  (BOD5, N-NO3, P-PO4, EC, dan TC) di SB, berturut-turut, sebesar 0.317 mg/l, 0.093 mg/l, 2 mg/l, >2420 MPN, dan >2420 MPN; di SM, berturut-turut, sebesar 0.029 mg/l, 1.859 mg/l, 17.7 mg/l, >2420 MPN, dan >2420 MPN; dan di ST, berturut-turut, sebesar 0.299 mg/l, 0.252 mg/l, 3.5 mg/l, >2420 MPN, dan >2420 MPN. Konsentrasi kualitas air ketiga sungai tersebut tidak berbeda secara signifikan (p>0.05), kecuali parameter N-NO3 (p<0.01). Secara umum, kondisi kualitas air ketiga sungai tersebut, menurut Peraturan Pemerintah No. 82, 2001) berada dalam status “tidak cocok” untuk peruntukannya.


Sign in / Sign up

Export Citation Format

Share Document