Experimental Study on the Flexural Property of GFRP I-Beam

2012 ◽  
Vol 594-597 ◽  
pp. 757-760
Author(s):  
Jin Yang Zheng ◽  
Guang You Zhang ◽  
Yun He Chen ◽  
Shi Zhen Li

The glass fiber reinforced polymer (GFRP) I-beams were tested under the third-point static loading. The load, mid-span deflection and failure modes were recorded during the flexural test. The flexural property was analyzed. The test results indicate that local buckling result in failure of integral structure. The local stability of flange plate is one of the main factors that affect the overall bending capacity of GFRP I-beams. Local strengthening should be adopted in the flange-web joint.

2014 ◽  
Vol 1079-1080 ◽  
pp. 258-265
Author(s):  
Chen Ning Cai ◽  
Shan He ◽  
Li Na Liu ◽  
Shi Kun Ou

Thispaper presents an experimental study to strengthen an existing bridge usingpre-stressed carbon fiber reinforced polymer (CFRP) and glass fiber reinforced polymer(GFRP) materials. The method using pre-stressed hybrid fiber reinforced polymer(HFRP) to strengthened structural members is an emerging pre-stressed strengtheningtechnology. In this study, experimental data selected from result of staticloading test conducted to hollow slabs with CFRP/GFRP has been compared with specimenswithout strengthening. Test results showed that the strengthening methoddeveloped in this study could effectively reduce the stress in hollow slab,improving the flexural rigidity and inhibiting the concrete from fracture.


2021 ◽  
Vol 11 (6) ◽  
pp. 2736
Author(s):  
Min Sook Kim ◽  
Young Hak Lee

In this study, the structural behavior of reinforced concrete flat plates shear reinforced with vertical grids made of a glass fiber reinforced polymer (GFRP) was experimentally evaluated. To examine the shear strength, experiments were performed on nine concrete slabs with different amounts and spacings of shear reinforcement. The test results indicated that the shear strength increased as the amount of shear reinforcement increased and as the spacing of the shear reinforcement decreased. The GFRP shear reinforcement changed the cracks and failure mode of the specimens from a brittle punching to flexure one. In addition, the experimental results are compared with a shear strength equation provided by different concrete design codes. This comparison demonstrates that all of the equations underestimate the shear strength of reinforced concrete flat plates shear reinforced with GFRP vertical grids. The shear strength of the equation by BS 8110 is able to calculate the punching shear strength reasonably for a concrete flat plate shear reinforced with GFRP vertical grids.


2017 ◽  
Vol 747 ◽  
pp. 220-225
Author(s):  
Alberto Pedro Busnelli ◽  
Ruben Edgardo López ◽  
Jorge Carlos Adue

This is the presentation of the research carried out by the Faculty of Engineering at Universidad Nacional de Rosario on the use of pultruded Glass Fiber Reinforced Polymer (GFRP) plates to increase the flexural strength of reinforced concrete beams.Pultruded plates are the type of elements made of composite materials which are most widely used for this kind of strengthening. Although around the world the material used for these plates is carbon fibers, its high cost prevents its widespread use in our country.One of the aims of our research program is, precisely, to verify whether it is possible to substitute such plates for significantly cheaper glass fiber elements manufactured in Argentina. The test results have proved that this alternative is feasible.What's more, the greater thickness of the glass fiber plates allows the use of additional anchor bolts. These bolts provide the system with post-critical resistance and ductility-characteristics which are absolutely necessary, for example, in structures in seismic areas.


2017 ◽  
Vol 2017 ◽  
pp. 1-14 ◽  
Author(s):  
S.-K. Lee ◽  
S.-Y. Yoo ◽  
C.-G. Park

This study evaluated the performance of a hybrid panel that can overcome the current problem of corrosion of the steel panels of improved movable weirs when they are exposed to a sulfate and calcium chloride environment such as sea water. A hybrid panel with glass fiber-reinforced polymer (GFRP) layers on both sides of a steel panel means that the central panel is not exposed to the external elements, which can avoid corrosion problems. In this study, to maximize the hybrid panel’s strength and durability, the moisture absorption characteristics and the durability in an accelerated environment were evaluated. The test results were considered to indicate no durability issues as the final absorption ratio was approximately 2.0% or less in all environments. Also, from the accelerated deterioration test results when the steel panel processed by sand blasting was applied in all accelerated deterioration environments, it satisfied the residual strength level of 65% or more. However, in the case without surface processing, upon exposure to MgSO4 solution, it did not satisfy the standard residual strength level of 65%. These results show that sand blasting on the surface of a steel panel is adequate for hybrid panels for improved movable weirs.


2011 ◽  
Vol 18 (1-2) ◽  
pp. 69-77 ◽  
Author(s):  
Sevket Ozden ◽  
Hilal Meydanli Atalay

AbstractThe strength and post-peak performance of reinforced concrete corbels, strengthened with epoxy bonded glass fiber reinforced polymer (GFRP) overlays, were experimentally investigated. The test variables were the corbel shear span to depth ratio, corbel main reinforcement ratio, and the number and orientation of the GFRP fibers. In total, 24 normal strength concrete, one-third scale, corbel specimens, without hoop reinforcement, were tested to failure under quasi-static gravity loading. Test results revealed that GFRP overlays can easily be used for the enhancement of corbel load bearing capacity, depending on the fiber orientation. The main reinforcement ratio and the number of GFRP plies were found to be the two main variables affecting the level of strength gain in the corbel specimens.


2016 ◽  
Vol 78 (5-2) ◽  
Author(s):  
Meng Jing ◽  
Werasak Raongjant

The objective of this research work is to determine the effect of wet-dry cycling on bond behavior of historic masonry structures strengthened by Glass Fiber Reinforced Polymer (GFRP). Shear bond testing was carried out through total 36 specimens exposed to dry, full moisture or wet-dry cycling conditions.  The selected samples were then tested at 0, 30, 60 and 90 days. Post-ageing test was also preceded on total sixty masonry prisms exposed to dry, full moisture or wet-dry cycling conditions. The compressive strengths of selected samples were then tested at 0, 40, 70 and 100 days. The test results showed an obvious decrease of the bond strength between GFRP sheets and bricks in the wet-dry cycling condition. For masonry prisms with or without GFRP strengthening, in the first 40 days, the compressive strength of GFRP bonded prism decreased quickly to the value near that of prism without GFRP. After 40 days the rate of decrease became slow, which means that, sheets retrofitted outside the masonry prisms helped to improve their durability by reducing water permeation. 


Author(s):  
Teoh Hui Xin ◽  
◽  
Norazman Mohamad Nor ◽  
Mohammed Alias Yusof ◽  
◽  
...  

Bamboo is an eco-friendly material, it can be used in various applications such as bamboo housing, bamboo bridges, bamboo scaffolding, ply bamboo, bamboo furniture, and for defence applications. It has various advantages to be used as structural material. However, it has weaknesses such as crushing failure under extreme loading that need to be addressed. The objective of this research is to enhance bamboo bearing and bending capacity using various stiffeners. Experimental work done is to investigate the compressive strength, bending strength, bearing strength and tensile strength of raw local bamboo. Further analysis includes bending and bearing strength of raw bamboo and strengthen bamboo using Glass Fiber Reinforced Polymer (GFRP) and Polyurethane (PU) Foams. From the test done, the bearing strength of raw bamboo Semantan with node is between 2.61 MPa to 3.14 MPa and for raw bamboo Semantan without node is between 0.28 MPa to 0.82 MPa, average bending strength of raw bamboo Semantan is 59 MPa. For strengthen bamboo with 4 layers of Glass Fiber Reinforced Polymer, the bearing strength without node is between 1.59 MPa to 2.38 MPa, and the average bending strength is 62 MPa which is about 5% higher than raw bamboo.


2020 ◽  
Vol 2020 ◽  
pp. 1-10
Author(s):  
Bo Wen ◽  
Chunfeng Wan ◽  
Lin Liu ◽  
Da Fang ◽  
Caiqian Yang

Fatigue behavior is an important factor for mechanical analysis of concrete members reinforced by basalt fiber reinforced polymer (BFRP) grid and polymer cement mortar (PCM) and plays a critical role in ensuring the safety of reinforced concrete bridges and other structures. In this study, on the basis of the static loading test results of concrete specimens reinforced by BFRP grid and PCM, a series of fatigue tests with different loading levels were conducted on interfaces between BFRP grid and concrete to investigate the fatigue behavior of BFRP grid-concrete interfaces. The test results indicate that with high loading level, the fatigue failure mode of interface is interfacial peeling failure while it transforms to the fatigue fracture of the BFRP grid under low loading level. The fatigue life (S-N) curves of BFRP grid-concrete interface are obtained and fitted in stages according to different failure modes, and the critical point of the two failure modes is pointed out. The relative slip evolution of interface during fatigue is further revealed in different stages with two failure modes, and the law of interface strain is studied with the increase of fatigue times. The relation of effective bonding length of interface and fatigue times is also described.


2018 ◽  
Vol 37 (9) ◽  
pp. 592-608 ◽  
Author(s):  
CY Zhu ◽  
YH Zhao ◽  
L Sun

The objective of this study is to investigate the seismic performance of fiber-reinforced polymer-reinforced concrete-filled thin-walled steel tube (CFTST). Twelve specimens with different fiber-reinforced polymer types (glass fiber-reinforced polymer and carbon fiber-reinforced polymer) and reinforcing modes were tested under constant axially compressive load and cyclic lateral load. The failure mode and lateral load versus displacement relationship for each specimen were recorded during testing. The strength, ductility, and energy dissipation capacity were analyzed accordingly. Further, a stress–strain relationship and a restoring force model of the fiber-reinforced polymer confining steel tube with local buckling were proposed. A hysteretic model for the fiber-reinforced polymer-reinforced CFTST was developed subsequently. The results indicate that the seismic performance of fiber-reinforced polymer-reinforced CFTST can be effectively improved by optimizing the fiber-reinforced polymer type and corresponding reinforcing scheme. Carbon fiber-reinforced polymer and glass fiber-reinforced polymer are suitable materials for the confinement and bending reinforcement of the column, respectively. The modeling results show the energy imported into the column is mainly dissipated by the thin-walled steel tube. The energy dissipation proportion of the steel tube, concrete core, and longitudinal fiber-reinforced polymer are >80%, 10%–20%, and <8%, respectively. The energy dissipation value of the steel tube can be improved more than 40% after effectively restraining the local buckling.


2021 ◽  
Vol 9 (1) ◽  
pp. 72-78
Author(s):  
Osama Daoud ◽  
Ahmed Fadul

The behavior and shear strength of concrete beams reinforced with glass fiber-reinforced polymer (GFRP) bars was investigated. Total of six reinforced concrete beams without stirrups were constructed and tested up to failure. The beams measured 1400 mm long, 150 mm wide and 300 mm deep and were tested in two-points bending with constant shear span 350 mm in all tested beams, and shear span to depth ratio a/d 1.37. The test variable was the reinforcement ratio. The test beams included three beams designed as tension control (T.C) with GFRP bars, three beams designed as compression control (C.C) with GFRP bars. The test results were compared with predictions provided by ACI 440.1R-15 design guideline and proposed equations in the literature. The test results indicated that the relatively low modulus of elasticity of FRP bars resulted in reducing shear strength. In addition, shear strength provided by ACI 440.1R-15 guideline underestimate shear strength capacity in which proposed equations in the literature had given better prediction than ACI 440.1R-15. The failure mode in T.C beams is diagonal tension by bond failure not by rupture of FRP and C.C beams is shear compression by crushing of the web in extreme fiber.  