Application of Electrochemical Techniques to Characterization of the Corrosion Behaviors of GW63 Alloys

2007 ◽  
Vol 546-549 ◽  
pp. 571-574
Author(s):  
Xing Wu Guo ◽  
Jian Wei Chang ◽  
Shang Ming He ◽  
Peng Huai Fu ◽  
Wen Jiang Ding

The corrosion behavior of GW63 (Mg-6wt.%Gd-3wt.%Y-0.4wt.%Zr) alloys in 5% NaCl aqueous solution has been investigated by PARSTAT 2273 instrument. The Open Circuit Potential (ECORR) vs. time curve, cyclic polarization (Pitting Scans) curve and Electrochemical Impedance Spectroscopy (EIS) was measured for the GW63 alloys in as-cast and T6 heat treatment conditions. The EIS results indicated that the tendency of impedance variation for as-cast condition was monotonic decreasing, however, the tendency of variation for T6 condition was not completely monotonic but the total tendency was decreasing. The values of impedance of GW63 alloy at 0.1 Hz are about 103 ohm-cm2 for as-cast and T6 condition.

Materials ◽  
2021 ◽  
Vol 14 (4) ◽  
pp. 744
Author(s):  
Ameeq Farooq ◽  
Umer Masood Chaudry ◽  
Ahsan Saleem ◽  
Kashif Mairaj Deen ◽  
Kotiba Hamad ◽  
...  

To protect steel structures, zinc coatings are mostly used as a sacrificial barrier. This research aims to estimate the dissolution tendency of the electroplated and zinc-rich cold galvanized (ZRCG) coatings of a controlled thickness (35 ± 1 μm) applied via brush and dip coating methods on the mild steel. To assess the corrosion behavior of these coated samples in 3.5% NaCl and 10% NaCl containing soil solutions, open circuit potential (OCP), cyclic polarization (CP), and electrochemical impedance spectroscopy (EIS) tests were performed. The more negative OCP and appreciably large corrosion rate of the electroplated and ZRCG coated samples in 3.5% NaCl solution highlighted the preferential dissolution of Zn coatings. However, in saline soil solution, the relatively positive OCP (>−850 mV vs. Cu/CuSO4) and lower corrosion rate of the electroplated and ZRCG coatings compared to the uncoated steel sample indicated their incapacity to protect the steel substrate. The CP scans of the zinc electroplated samples showed a positive hysteresis loop after 24 h of exposure in 3.5% NaCl and saline soil solutions attributing to the localized dissolution of the coating. Similarly, the appreciable decrease in the charge transfer resistance of the electroplated samples after 24 h of exposure corresponded to their accelerated dissolution. Compared to the localized dissolution of the electroplated and brush-coated samples, the dip-coated ZRCG samples exhibited uniform dissolution during the extended exposure (500 h) salt spray test.


2019 ◽  
Vol 271 ◽  
pp. 07009
Author(s):  
Changkyu Kim ◽  
Reece Goldsberry ◽  
Ahmad Ivan Karayan ◽  
Jose Milla ◽  
Marwa Hassan ◽  
...  

We present the preparation and inhibition behavior of rebar in the presence of calcium nitrate (CN)-containing microcapsules with concentrations of 0.50, 2.00, and 5.00 wt.% in concrete. From both open circuit potential (OCP) and electrochemical impedance spectroscopy spectra, it was found that an addition of microcapsules containing CN corrosion inhibitor into concrete beams successfully repassivated or maintained the passivity of the rebar when the concrete was cracked. This corrosion inhibitor repassivated the rebar by forming a passive layer on the rebar surface under the crack. This repassivation process was evident by an increase of OCP values to more positive values or by stable OCP values at around -100 mV vs SCE. An increase in phase angle after corrosion activation for the sample with 2.00 wt.% microcapsule clearly showed this repassivation process. The optimum concentration for maintaining the passivity on rebar in the cracked concrete was found to be 5.00 wt.%.


2001 ◽  
Vol 674 ◽  
Author(s):  
A. Sokolov ◽  
J.R. Jennings ◽  
C-S Yang ◽  
J. Redepenning ◽  
B. Doudin

ABSTRACTElectrochemical impedance spectroscopy is used to characterize the growth of NiO over Ni electrodes. We find a limited increase of thickness and a significant increase of porosity of the oxide as a function of time and anodization potential. Conductance measurements performed on Ni/NiO/Co junctions of 30 nm diameters indicate the presence of a Coulomb blockade at low temperatures and small bias. Tunneling is observed at higher bias. Small magnetoresistance ratios (1%) are found.


2016 ◽  
Vol 835 ◽  
pp. 131-135 ◽  
Author(s):  
Francis Mulimbayan ◽  
Manolo G. Mena

Stainless steel (SS) is one of the most commonly used metallic food contact materials. It may be classified based on its microstructure whether ferritic, austenitic, martensitic, duplex or precipitation hardened. Austenitic SS, among mentioned grades, has the largest contribution to market due to its numerous industrial and domestic applications. In this study, the corrosion behavior of AISI 202 SS – a cheaper grade of stainless steel, in three different solution temperatures of citric acid was investigated using different electrochemical techniques such as open-circuit potential (OCP) measurements, potentiodynamic polarization and electrochemical impedance spectroscopy (EIS). The results were compared to that obtained from conventional AISI 304 SS. OCP, polarization and impedance measurements agreed that AISI 202 SS has comparable resistance to that of AISI 304 SS in citric acid at ambient temperature and at 50 °C. At 70 °C, results of OCP measurements suggest that AISI 304 SS exhibited greater performance as indicated by more positive OCP values in the designated solution. EIS results indicate that the two alloys have identical corrosion resistance even at 70 °C as indicated by their comparable polarization resistance (Rp). The corrosion mechanism in both alloys is charge-transfer controlled as indicated by depressed semi-circular appearance of the generated Nyquist plots. The values of corrosion current densities (icorr) extracted from polarization curves indicate that the initial corrosion rates were higher in AISI 304 than AISI 202 SS suggesting that formation of more protective film may have occurred on the former alloy.


2012 ◽  
Vol 66 (2) ◽  
pp. 187-192
Author(s):  
Rade Surudzic ◽  
Sanja Erakovic ◽  
Vesna Miskovic-Stankovic

In order to improve corrosion stability and biocompatibility of titanium surfaces, hydroxyapatite (Ca10(PO4)6(OH)2, HAP) has been used as coating material due to the fact that it possess similar chemical composition as bone tissue. Lignin?s (Lig) usage in medical applications could be interesting because it could lead to thermal stability, hydrophilicity, biocompatibility and biodegradability of different materials. Bioceramic hydroxyapatite/lignin (HAP/Lig) coatings on titanium were obtained from ethanol suspension by electrophoretic deposition method. The uniform and compact HAP/Lig coatings were deposited at constant voltage of 60 V for 45 s and sintered at 900?C in argon atmosphere. The corrosion stability of sintered HAP/Lig coatings in simulated body fluid (SBF) at 37?C was investigated by open circuit potential-time measurements and electrochemical impedance spectroscopy (EIS). The greater values of open circuit potential, as well as EIS results, indicated improved corrosion resistance and good corrosion stability of HAP/Lig coatings in simulated body fluid at 37?C .


2016 ◽  
Vol 835 ◽  
pp. 115-120
Author(s):  
Francis Mulimbayan ◽  
Manolo G. Mena

All materials which are intended to have in contact with food and other commodities produced or processed for human consumption are called food contact materials (FCM’s). Stainless steel (SS) – a widely known metallic FCM is used mainly in processing equipment, containers and household utensils. It is known for having numerous industrial and domestic applications worldwide due to its special characteristics of having notable corrosion resistance. However, this corrosion resistance is not all-encompassing since SS may still undergo degradation when subjected to a specific corrosion-inducing environment. SS may be classified according to its microstructure. If the atoms which make up the SS can be viewed as having a face-centered cubic structure, then the alloy is said to be austenitic. This SS grades include the conventional 300-series and the newly-developed 200-series. The former has superior corrosion resistance while the latter is far cheaper. In this study, the corrosion behavior of AISI 202 SS in two different levels of dissolved oxygen (O2) and three acid concentrations was investigated using electrochemical techniques, namely, open-circuit potential (OCP) measurements and electrochemical impedance spectroscopy (EIS). As the concentration of citric acid is increased, the measured OCP values of the alloy decreased and the polarization resistance (Rp) decreased, indicating decrease in alloy stability and decline in the corrosion resistance, respectively. With regards to effects of dissolved O2, results revealed that increasing the level of dissolved O2 has consequently increased the polarization resistance and shifted the OCP to more positive values. All the generated Nyquist plots exhibited a depressed capacitive loops indicating that corrosion in the designated solution occurred with charge transfer as the rate-determining step.


2018 ◽  
Vol 69 (11) ◽  
pp. 2964-2968
Author(s):  
Ioana Alina Ciobotaru ◽  
Oana Claudia Ciobotea Barbu ◽  
Florin Mihai Benga ◽  
Danut Ionel Vaireanu

This paper discusses the improvements achieved in the anticorrosive properties of some silane films by pretreating the metallic substrate prior to films deposition and by reinforcement with some reinforcement agents. One has compared the behaviour of silane films, deposited on aluminium substrate, and the reinforced silane films deposited on anodised aluminium substrate. The use of scanning electron microscopy highlighted the modifications of substrate surface characteristics prior and after the anodisation process, while electrochemical techniques such as open circuit potential, electrochemical impedance spectroscopy and potentiodynamic polarization were employed in order to characterize the deposited films from the corrosion behaviour point of view.


2015 ◽  
Vol 229 (3) ◽  
Author(s):  
Waheed A. Badawy ◽  
Mohamed M. El-Rabiei ◽  
Hashem M. Nady ◽  
Mohammed A. Samy

AbstractThe electrochemical behavior of Cu-10Ni-10Zn alloy and Cu was investigated in acidic, neutral and basic solutions. The effect of chloride ions in neutral solutions was also studied. Conventional electrochemical techniques and electrochemical impedance spectroscopy were used. The corrosion rate of these materials in acidic solutions is relatively high compared to that in neutral or basic solutions. The open-circuit potential of the alloy is nearly the same as that of pure copper in the different media, indicating that the processes which occur on the alloy surface are mainly governed by copper dissolution. In chloride solutions the rate of Cu corrosion is remarkably high. In the alloy, the copper dissolution was suppressed by the presence of nickel and zinc, due to the formation of complex oxide layers. The impedance data were fitted to equivalent circuit models that explain the different electrochemical processes occurring at the electrode/electrolyte interface. SEM and EDAX have shown that the alloy surface is enriched with Ni. In neutral solutions the chloride ions are penetrating the metallic surface.


2017 ◽  
Vol 64 (6) ◽  
pp. 644-653 ◽  
Author(s):  
A.U. Chaudhry ◽  
Vikas Mittal ◽  
M.I. Hashmi ◽  
Brajendra Mishra

Purpose Inorganic oxide addition can be synergistically beneficial in organic coatings if it can impart anti-corrosion properties and also act as an additive to enhance physical and/or chemical properties. The aim of this study was to evaluate the anti-corrosion benefits of nano nickel zinc ferrite (NZF) in the polymer film. Design/methodology/approach The time-dependent anti-corrosion ability of NZF (0.12-1.0 per cent w/w NZF/binder), applied on API 5L X-80 carbon steel, was characterized by electrochemical techniques such as open circuit potential, electrochemical impedance spectroscopy, linear polarization resistance and potentiodynamic. Characterization of corrosion layer was done by removing coatings after 216 h of immersion in 3.5 per cent w/v NaCl. Optical microscopy, field emission scanning electron microscopy and X-ray diffraction techniques were used to characterize the corroded surface. Findings Corrosion measurements confirm the electrochemical activity by metallic cations on the steel surface during corrosion process which results in improvement of anti-corrosion properties of steel. Moreover, surface techniques show compact corrosion layer coatings and presence of different metallic oxide phases for nanocomposite coatings. Originality/value The suggested protection mechanism was explained by the leaching and precipitation of metallic ion on the corroded surface which in turn slowed down the corrosion activity. Furthermore, improvement in barrier properties of rubber-based coatings was confirmed by the enhanced pore resistance. This work indicates that along with a wide range of applications of NZF, anti-corrosion properties can be taken as an addition.