Improvement of the Corrosion Resistance of Biomedical Magnesium Alloys in the Ringer’s Solution Using Protective Coatings

2015 ◽  
Vol 227 ◽  
pp. 459-462
Author(s):  
Iwona Kot ◽  
Halina Krawiec

The corrosion resistance of magnesium alloys depends on their microstructure, especially the presence of different intermetallic phases and precipitates. In this paper, the electrochemical behaviour of Mg1Ca and Mg1Ca1Si magnesium alloys has been investigated in the Ringer’s solution at 37 °C. In order to improve the corrosion resistance of these magnesium alloys composite coatings were fabricated by modification of a chitosan layer. The coatings were prepared by dip-coating in a chitosan solution and then modified by electrochemical deposition of a layer from a solution containing fluorine ions and water glass. The electrochemical performance of chitosan and chitosan modified coated alloys was evaluated by linear sweep voltamperometry and electrochemical impedance spectroscopy. The coated magnesium alloys possess suitable corrosion behaviour for the application as biodegradable implant material.

2014 ◽  
Vol 2014 ◽  
pp. 1-9 ◽  
Author(s):  
H. Ashassi-Sorkhabi ◽  
H. Aminikia ◽  
R. Bagheri

Ni-Cu-P/nano-Al2O3composite coatings are prepared on mild steel from an alkaline electroless plating bath containing different concentrations of Al2O3nanoparticles. The protective effect of codeposited nanoparticles on the corrosion behaviour of the coatings is studied in 0.5 M H2SO4solution. The electrochemical methods, that is, electrochemical noise (ECN), electrochemical impedance spectroscopy (EIS), and polarization measurements, are used to characterize the corrosion properties of the coatings. The results show that the inclusion of nanosized particles leads to significant improvement of corrosion resistance of the coatings. The highest corrosion resistance is obtained at 20 ppm of nanoparticles concentration in the plating bath. The ECN measurements results are in good agreement with results obtained from two other electrochemical methods after trend removal. The SEM images prove that nano-Al2O3particles were embedded in the Ni-Cu-P matrix and are dispersed uniformly on the coating surface.


2013 ◽  
Vol 2013 ◽  
pp. 1-10 ◽  
Author(s):  
A. Robin ◽  
O. A. S. Carvalho

Ti-Nb-Zr alloys are interesting materials for implant applications due to the atoxic character of the Nb and Zr alloying elements and to their low elastic modulus when compared to CP-Ti. In this work, the corrosion behaviour of CP-Ti, Ti-5Nb-13Zr, Ti-13Nb-13Zr, and Ti-20Nb-13Zr alloys was investigated in Ringer’s solution of pH 2, 5, and 7.5 without fluorides and containing 1000 ppm F at 37°C, through open-circuit potential measurements, potentiodynamic polarization, and electrochemical impedance spectroscopy. The four materials showed a passive behavior in Ringer's solution without fluorides for pH ranging from 2 to 7.5 and in Ringer's solution of pH 5 and 7.5 containing 1000 ppm F but presented an active behavior in Ringer's solution of pH 2 containing fluorides. The corrosion resistance of all materials in Ringer's solution decreases with both decrease of pH and addition of fluorides. Ti-13Nb-13Zr alloy is a little more corrosion resistant than the Ti-5Nb-13Zr and Ti-20Nb-13Zr alloys and, in most conditions, the Ti-Nb-Zr alloys present higher corrosion resistance than CP-Ti.


Author(s):  
Simona BOICIUC ◽  
◽  
◽  

The undertaken research which is described in this paper aims at the corrosion behaviour of composite coatings in nickel matrix using as dispersed phase technical alumina with dimensions of 5 μm and their characterization from a microstructural point of view. The corrosion resistance in the saline fog of the coatings is influenced by the microstructure, the stresses developed in the layer and the roughness.


Metals ◽  
2021 ◽  
Vol 11 (5) ◽  
pp. 704
Author(s):  
Marija Riđošić ◽  
Nebojša D. Nikolić ◽  
Asier Salicio-Paz ◽  
Eva García-Lecina ◽  
Ljiljana S. Živković ◽  
...  

Electrodeposition and characterization of novel ceria-doped Zn-Co composite coatings was the main goal of this research. Electrodeposited composite coatings were compared to pure Zn-Co coatings obtained under the same conditions. The effect of two ceria sources, powder and home-made sol, on the morphology and corrosion resistance of the composite coatings was determined. During the electrodeposition process the plating solution was successfully agitated in an ultrasound bath. The source of the particles was found to influence the stability and dispersity of plating solutions. The application of ceria sol resulted in an increase of the ceria content in the resulting coating and favored the refinement from cauliflower-like morphology (Zn-Co) to uniform and compact coral-like structure (Zn-Co-CeO2 sol). The corrosion resistance of the composite coatings was enhanced compared to bare Zn-Co as evidenced by electrochemical impedance spectroscopy and scanning Kelvin probe results. Zn-Co doped with ceria particles originating from ceria sol exhibited superior corrosion resistance compared to Zn-Co-CeO2 (powder) coatings. The self-healing rate of artificial defect was calculated based on measured Volta potential difference for which Zn-Co-CeO2 (sol) coatings exhibited a self-healing rate of 73.28% in a chloride-rich environment.


2005 ◽  
Vol 11 (S03) ◽  
pp. 82-85 ◽  
Author(s):  
E. T. Uzumaki ◽  
C. S. Lambert ◽  
A. R. Santos Jr. ◽  
C. A. C. Zavaglia

Diamond-like carbon (DLC) films have been intensively studied with a view to improving orthopaedic implants. Studies have indicated smoothness of the surface, low friction, high wear resistance, corrosion resistance and biocompatibility [1-4]. DLC coatings can be deposited using various techniques, such as plasma assisted chemical vapour deposition (PACVD), magnetron sputtering, laser ablation, and others [5]. However it has proved difficult to obtain films which exhibit good adhesion. The plasma immersion process, unlike the conventional techniques, allows the deposition of DLC on three-dimensional workpieces, even without moving the sample, without an intermediate layer, and with high adhesion [6], an important aspect for orthopaedic articulations. In our previous work, DLC coatings were deposited on silicon and Ti-13Nb-13Zr alloy substrates using the plasma immersion process for the characterization of microstructure, mechanical properties and corrosion behaviour [7-9]. Hardness, measured by a nanoindenter, ranged from 16.4-17.6 GPa, the pull test results indicate the good adhesion of DLC coatings to Ti-13Nb-13Zr, and electrochemical assays (polarization test and electrochemical impedance spectroscopy) indicate that DLC coatings produced by plasma immersion can improve the corrosion resistance [9].


Author(s):  
Muddasir Nawaz ◽  
Sehrish Habib ◽  
Adnan Khan ◽  
Abdul Shakoor ◽  
Ramazan Kahraman

The use of organic coating for the metals has been widely being used to protect the surface against corrosion. Polymeric coating incorporated with Nanocontainers loaded with inhibitor and self-healing provides better corrosion resistance. Cellulose microfibers (CMFs) used as smart carriers were synthesized and loaded with dodecylamine (DOC)-inhibitor and polyethyleneimine (PEI)-both inhibitor and self-healing agents. Smart polymeric coatings were developed by mixing CMF/DOC and CMFs/PEI into the epoxy matrix. Reference coatings (that has only CMFs) were also prepared for a compersion. Scanning electron microscope (SEM), X-ray diffraction spectroscopy (XRD), Fourier transform infrared spectroscopy (FTIR) and thermal gravitational analysis (TGA) were used to confirm the loading of DOC and PEI onto the CMFs. UV-vis analysis indicates that the self-release of inhibitor from CMFs is sensitive to pH of the solution and the immersion time. Recovery of controlled surface damage confirms the decent self-healing ability of the prepared smart coatings is due to the efficient release of inhibitor (DOC) and self-healing agent (PEI) in the damaged area leading to the formation of a protective film. Electrochemical impedance spectroscopy (EIS) results demonstrate that corrosion resistance of the smart coating increases with an increase in immersion time which is due to the progressive release of inhibitors from CMFs in response to the pH change. Therefore, smart coatings demonstrate superior properties as compared to the reference coatings. The study reveals the polymeric composite coatings have potential to inhibit the corrosion of steel for oil and gas industry.


CORROSION ◽  
10.5006/3767 ◽  
2022 ◽  
Author(s):  
Malvika Karri ◽  
Amit Verma ◽  
J.B. Singh ◽  
Sunil Kumar Bonagani ◽  
U.K. Goutam

This work seeks to understand the underlying mechanism involved in passivity of Ni-Cr-Mo alloys in a less concentrated HCl solution (1M) by systematically varying contents of Cr and Mo solutes in model Ni-Cr-Mo alloys. Corrosion behaviour was evaluated based on potentiodynamic polarisation tests carried out in conjunction with electrochemical impedance and x-ray photoelectron spectroscopies of passive films that formed on alloys during their exposure to the HCl solution. Results have shown that an increase in Mo alone is not sufficient to improve the corrosion resistance of the alloys at lower concentrations of HCl. Optimum concentrations of Cr and Mo solutes have been found to be in the vicinity of ~17 wt.% Cr and ~19 wt.% Mo for superior corrosion resistance of the alloys. This was attributed to the protection of the Cr2O3 layer as a consequence of the enrichment of Mo6+ ions in the passive film in 1M HCl solution.


MRS Advances ◽  
2020 ◽  
Vol 5 (40-41) ◽  
pp. 2129-2137 ◽  
Author(s):  
Wenwen Dou ◽  
Wen Li ◽  
Yuchen Cai ◽  
Mengyao Dong ◽  
Xiaojing Wang ◽  
...  

ABSTRACTTo improve the corrosion resistance and to increase the hardness of copper substrate in marine environment, the Cu-Ni/Ni-P composite coatings were prepared on the copper substrate using the galvanostatic electrolytic deposition method. The deposition current densities were explored to find the optimized deposition conditions for forming the composite coatings. Corrosion resistance properties were analyzed using the polarization curves and electrochemical impedance spectroscopy (EIS). Considering the corrosion resistance and hardness, the −20 mA/cm2 was selected to deposit Cu-Ni coatings on copper substrate and the −30 mA/cm2 was selected to deposit Ni-P coating on the Cu-Ni layer. The Cu-Ni/Ni-P composite coatings not only exhibited superior corrosion resistance compared to single Cu-Ni coating in 3.5 wt.% NaCl solution, but also showed much better mechanical properties than single Cu-Ni coating.


2019 ◽  
Vol 26 (10) ◽  
pp. 1950080
Author(s):  
JIBO JIANG ◽  
HAOTIAN CHEN ◽  
LIYING ZHU ◽  
YAOXIN SUN ◽  
WEI QIAN ◽  
...  

Graphene oxide (GO) sheet and ultrasonic field (UF) were successfully employed to produce Ni–B/GO and UF–Ni–B/GO composite coatings on Q235 mild steel by electroless plating. The composite coatings’ structure and surface morphology were characterized by scanning electron microscopy (SEM), X-ray diffraction (XRD), Raman spectroscopy and X-ray photoelectron spectroscopy (XPS). Results showed that GO was successfully co-deposited in the Ni–B alloy. Moreover, UF–Ni–B/GO composite coatings have smoother surface and thicker cross-section than others. The microhardness and corrosion resistance of the sample coatings were determined using Vickers hardness tests, Tafel electrochemical tests and electrochemical impedance measurements (EIS) in 3.5[Formula: see text]wt.% NaCl solution to receive the effect of GO and ultrasonic. The findings indicated that UF–Ni–B/GO exhibited optimum hardness (856[Formula: see text]HV) and enhanced corrosion resistance (6.38 [Formula: see text][Formula: see text] over the Ni–B and Ni–B/GO coatings. Due to these interesting properties of the coating, it could be used as a protective material in the automotive and aerospace industries for parts of machines that were manipulated in high temperature and corrosive environments.


2019 ◽  
Vol 31 (4) ◽  
pp. 891-895
Author(s):  
Dinesh Kumar Chelike ◽  
K. Juliet Gnana Sundari

Considering the good corrosion resistance of Zn-Ni alloy, it is selected in the present study to be the protective coating on mild steel and it is considered as a strong candidate for the replacement of environmentally hazardous cadmium. Zn-Ni alloy coating is applied by electrodeposition at optimum temperature, current density and time. The bath solution used is consisting of EDTA as complexing agent. The electrodeposition is also carried out with tartaric acid and benzaldehyde additives to have good corrosion resistance and brightness. The electrodeposits obtained with and without additives are examined for nature and alloy composition. The corrosion behaviour of the electrodeposits is studied by Tafel polarization and electrochemical impedance spectroscopy.