scholarly journals Pre-lens tear film evaluation scale: a tool for analyzing the tear film-lens interaction with respect to the material used

2012 ◽  
Vol 2 (1) ◽  
pp. 7
Author(s):  
Papagni Antonio ◽  
Rossella Fonte ◽  
Luca Benzoni

In clinical practice, to avoid or reduce the failure rate among users of contact lenses, it is necessary to obtain a detailed patient case history, information concerning symptoms, and a complete eye examination. In addition, application of an auxiliary photographic reference scale might increase the chances of improving initial success or, for existing contact lens wearers, provide insight into the extent or severity of symptoms. Patient symptoms are often directly related to contact lens failure, which in turn is related to the quality of the pre-corneal tear film as well as the <em>wettability</em> of the contact lens surface. We describe the relationship between the quality of the tear film, with particular attention to pre-contact lens tear film, variability in contact tolerance, and the material of which the contact lens is made.

Author(s):  
Рогожникова ◽  
Elena Rogozhnikova ◽  
Селиверстова ◽  
Nataliya Seliverstova ◽  
Розанова ◽  
...  

The aim of the study was to evaluate the effectiveness of multifocal contact lens correction in patients with presbyopia and myopic refractive error. The study involved 45patients with myopia ranging in age from 43 to 56years in conditions of habitual monofocal contact lens correction, a month after the selection and wearing multifocal contact lenses. Contact correction was carried out according to standard procedures taking into account the accuracy of contact lens fitting, with carrying out functional tests for the “dry eye” syndrome and evaluation of corneal epithelial thickness (Optovue, USA). The as-sessment of the following parameters of visual perception was made: far, near and middle distance (monocular and binocular) visual acuity, the spatial contrast sensitivity, stereovision (I &amp; II Lang test), the area of binocular interaction field (binarymeter), the quality of vision (VF-14 test ). The use of multifocal contact lenses for the correction of presbyopia with the initial myopic refraction ensures high functional results at different distances. Patients with a myopic refraction, previously used contact lenses, easy pass to multifocal correction option. The greatest satisfaction by achieved vision noted in those patients who had achieved refraction (–)0.5diopters. In the selection of contact lenses in older patients the thickness of the corneal epithelium and tear film validity must be taken into account.


The Eye ◽  
2020 ◽  
Vol 22 (129) ◽  
pp. 44-46
Author(s):  
Mark Eddleston

Optimum Infinite is a new GP contact lens material, with an oxygen permeability of 180 barrer and was launched by Contamac at the GSLS 2019. This article provides an insight into the development and characteristics of this breakthrough material.


2019 ◽  
Vol 16 (4) ◽  
pp. 310-323 ◽  
Author(s):  
Marko Banovic ◽  
Lavanya Athithan ◽  
Gerry P McCann

Aortic stenosis and diabetes mellitus are both progressive diseases which, if left untreated, result in significant morbidity and mortality. There is evidence that the prevalence of diabetes is substantially increased in patients with aortic stenosis and those with diabetes have increased rates of progression from mild to severe aortic stenosis. There are good data supporting the hypothesis that aortic stenosis and diabetes mellitus are associated with diabetes mellitus being detrimental towards the quality of life and survival of patients. Thus, a thorough understanding of the pathogenesis of both of these disease processes and the relationship between them aids in designing appropriate preventive and therapeutic approaches. This review aims to give a comprehensive and up-to-date insight into the influence of diabetes mellitus on patients with degenerative aortic stenosis, as well as the prognosis and therapeutic approach to these patients.


2014 ◽  
Vol 5 (1) ◽  
Author(s):  
Aleksandra Debeljković Mitrović ◽  
Dragomir Stamenković ◽  
Manuel Conte ◽  
Božica Bojović ◽  
Spomenko Mihajlović

In this paper results of comparative study of the optical power of soft contact lenses (SCL) made of standard material for SCL and nanophotonic materials with different measurement techniques used for the final contact lens controllers are presented. Three types of nanophotonic soft contact lenses were made of standard polymacon material (Soleko SP38TM) incorporated with fullerene C60, fullerol C60(OH)24 and fullerene metformin hydroxylate C60(OH)12(OC4N5H10)12. For the purposes of material characterization for potential application as soft contact lenses, the optical properties of the soft contact lenses were measured by Rotlex and Nidek device. With Rotlex device the following optical results were obtained: optical power and map of defects, while with the Nidek device: optical power, cylinder power and cylinder axis. The obtained values of optical power and map of defects showed that the optical power of synthesized nanophotonic soft contact lens is same to the nominal value, while this was not the case for the standard soft contact lens. Also, the quality of the nanophotonic soft contact lens is better than the standard one. Hence, it is possible to synthesize new nanophotonic soft contact lenses of desired optical characteristics, implying possibilities for their application in this field.


Author(s):  
Patricia Sylla

Basic anatomy and physiology 314 History taking 320 Basic eye examination 322 Quick reference list 326 Vision-threatening injuries 328 Eyelid lumps 336 Foreign bodies 337 Sore and itchy eyes 337 Tear film insufficiency 338 Blepharitis 339 Contact lens related problems 340 Herpes zoster ophthalmicus (HZO) ...


Biomaterials ◽  
2001 ◽  
Vol 22 (24) ◽  
pp. 3257-3260 ◽  
Author(s):  
Christine E. Soltys-Robitaille ◽  
Daniel M. Ammon ◽  
Paul L. Valint ◽  
George L. Grobe III

2017 ◽  
Vol 2017 ◽  
pp. 1-17 ◽  
Author(s):  
L. Rico-Del-Viejo ◽  
M. Garcia-Montero ◽  
J. L. Hernández-Verdejo ◽  
S. García-Lázaro ◽  
F. J. Gómez-Sanz ◽  
...  

Objectives. To describe the past 20 years’ correction modalities for keratoconus and their visual outcomes and possible complications.Methods. A review of the published literature related to the visual outcomes and possible complications in the context of keratoconus management using nonsurgical procedures for the last 20 years (glasses and contact lenses) was performed. Original articles that reported the outcome of any correction modalities of keratoconus management were reviewed.Results. The most nonsurgical procedure used on keratoconus management is the contact lens fitting. Soft contact lenses and soft toric contact lenses, rigid gas-permeable contact lenses, piggyback contact lens system, hybrid contact lenses, and scleral and corneoscleral contact lenses form the contemporary range of available lens types for keratoconus management with contact lenses. All of them try to restore the vision, improve the quality of life, and delay surgical procedures in patients with this disease. Complications are derived from the intolerance of using contact lens, and the use of each depends on keratoconus severity.Conclusions. In the context of nonsurgical procedures, the use of contact lenses for the management of keratoconic patients represents a good alternative to restore vision and improve the quality of live in this population.


1999 ◽  
Vol 13 (3) ◽  
pp. 385-408 ◽  
Author(s):  
SHARLENE HESSE-BIBER ◽  
MARGARET MARINO ◽  
DIANE WATTS-ROY

This study provides insight into factors that determine whether women in the college population who exhibit eating-disordered behavior during their college years recover during their postcollege years. The study assessed changes in the eating patterns of 21 women across a six-year time period, from sophomore year in college to two years postcollege. Eleven of the women get better during their postcollege year, whereas 10 of the women continue to struggle with disordered eating. The major differences between the two groups revolve around the relationship between autonomy and relation. Women who get better negotiate the tension between autonomy and relatedness and are more likely to have higher selfesteem based on a more positive self-concept; this, in turn, leads to healthier relationships with food and body image. Two factors that appear to influence this negotiation include (I) one's history of chronic physical or sexual abuse and (2) the quality of familial messages about food, body image, relationship, and autonomy.


2019 ◽  
Vol 31 (4) ◽  
pp. 1001-1004
Author(s):  
Nikola Peev

The modern world is very fast and dynamic. Consumer requirements rise to every commodity part of their everyday life - food, clothing, cosmetics, and medical devices. Eye care and eye health are also part of them. Companies producing contact lenses work daily to improve the safety and comfort of wearing, as well as on the technical characteristics of the material (type of material, wear time, module, Dk / t etc.). Silicon hydrogel contact lenses (SiHy) were introduced almost two decades ago. At that time it was estimated that there are about 70 million contact lenses all over the world. Since then, their number has doubled and a significant majority now have silicone-hydrogel contact lenses, resulting in a steady and noticeable reduction in the number of regular hydrogel lenses. When the first one-day silicon-hydrogel contact lenses were introduced in 2008, they were announced as breakthroughs in technology. When they were introduced to the market, they were presented in spherical, toric and multifocal designs, which led to a significant increase in the use / prescription of silicon-hydrogel daily disposable contact lenses. A survey conducted in 2014 by the International Consortium illustrates this point. Although, according to this study, the use of SiHy contact lenses varies widely across the world. In the United States, Canada, Australia and the United Kingdom, four to six times more patients were fitted with silicone-hydrogel CLs compared to hydrogels in 2014 and in each country, daily disposable SiHy contact lenses were prescribed with a larger frequency compared to daily disposable hydrogel lenses. It is important to make a good fit to ensure and increase the comfort of wearing contact lenses. In addition to some of the standard fitting techniques such as: keratometry and choice of base curve of the lens; size and eccentricity; an assessment of the mobility of a lens placed in the eye - look positions, mobility, push up test, can be added and the wetting of the contact lens. Even in perfect fit, if the lens does not interact well with the tear film, it would lead to complaints and discomfort in the patient. The degree of wetting is determined by the balance between adhesive and cohesive forces acting on the surface of the lens. CLs, which can support full wetting, allow a tight coating of the tear film, a smooth recovery of the tear layer after eyelid opening and good visual acuity. The interaction between CL, eye surface and tear film is vital to their successful fit. It has long been known that both the organic and inorganic components of the tear film and anterior surface of the eye can deposit deposits on the contact lenses. There are various non-invasive methods for assessing the tear film and, above all, the lipid layer. Some of these are Non invasive breakup time (NIBUT) and specular biomicroscopy. In the present work we will look at daily disposable silicone-hydrogel contact lenses that have been tested in vivo for good wetting, stability and good regeneration of the tear film.


2019 ◽  
Vol 823 ◽  
pp. 105-109
Author(s):  
Hung Jung Tsai ◽  
Jeng Haur Horng ◽  
Chung Ming Tan

It is popular to wear the contact lens nowadays. Also, the output value of the contact lens is estimated more than 4 billion NT dollar every year. Because the phenomena of the contact lenses are very complicated, the relevant mechanisms are not well understood. Thus, the security of contact lens needs to be further investigated. In the lubricated mechanism of the contact lens, there is a layer of tear between the contact lens and cornea. The contact lens’ behavior is akin to that of a slider bearing. The lens represents the slider, the eye plays the role of the stationary pad, and the tear film is the lubricant. Hence, hydrodynamics and contact mechanisms of a contact lens are quite a fascinating subject that is relevant to the science of tribology. In the paper, the lubrication mechanisms include the partial hydrodynamic lubrication (contact lens roughness), contact mechanics and Newtonian fluid mechanics have been established. The parameters of roughness, flow factor, tear film geometry, and hydrodynamic pressure distribution are discussed. The developed technology increases the safety of contact lens.


Sign in / Sign up

Export Citation Format

Share Document