scholarly journals Comparison of Mechanical Properties of Lightweight and Normal Weight Concretes Reinforced with Steel Fibers

2018 ◽  
Vol 8 (2) ◽  
pp. 2741-2744
Author(s):  
A. Ali ◽  
Z. Soomro ◽  
S. Iqbal ◽  
N. Bhatti ◽  
A. F. Abro

Compared to conventional concrete, lightweight concrete is more brittle in nature however, in many situations its application is advantageous due to its lower weight. The associated brittleness issue can be, to some extent, addressed by incorporation of discrete fibers. It is now established that fibers modify some fresh and hardened concrete properties. However, evaluation of those properties for lightweight fiber-reinforced concrete (LWFC) against conventional/normal weight concrete of similar strength class has not been done before. Current study not only discusses the change in these properties for lightweight concrete after the addition of steel fibers, but also presents a comparison of these properties with conventional concrete with and without fibers. Both the lightweight and conventional concrete were reinforced with similar types and quantity of fibers. Hooked end steel fibers were added in the quantities of 0, 20, 40 and 60kg/m3. For similar compressive strength class, results indicate that compared to normal weight fiber-reinforced concrete (NWFC), lightweight fiber-reinforced concrete (LWFC) has better fresh concrete properties, but performs poorly when tested for hardened concrete properties.

Author(s):  
Klaus Holschemacher ◽  
Ahsan Ali ◽  
Shahid Iqbal

In construction industry lightweight concrete and fiber reinforced concrete are being used for many years. The former is known for brittle nature, light in weight and low thermal conductivity properties. It also offers better workability when compared to the normal weight concrete for the same slump value. These properties are however affected by addition of discrete fibers. Among the affected properties is also the bond between steel and concrete surrounding it. The integrity of a reinforced concrete member is not ensured in the absence of adequate bond. Due to limited literature on the subject matter, an experimental program was carried out to understand the bond behavior in lightweight concrete after fiber inclusion. For the purpose modified pull-out specimens made of Lightweight Fiber Reinforced Concrete (LWFC) were tested. Hooked end steel fibers having length 35 mm and diameter 0.5 mm (l/d = 0.7) were incorporated in dosages of 0, 20, and 40 kg/m3. Besides pull-out specimens, testes were also carried out for fresh and hardened properties of LWFC. Tests results indicate higher pull-out loads for higher fiber contents. The average increase in ultimate bond strength was observed at 28% and 2% for 40 kg/m3 and 20 kg/m3 fiber contents respectively. The fresh concrete density, compressive strength of mixes reduced and air-content values increased with increase in fiber content.


2020 ◽  
Vol 14 (2) ◽  
pp. 6734-6742
Author(s):  
A. Syamsir ◽  
S. M. Mubin ◽  
N. M. Nor ◽  
V. Anggraini ◽  
S. Nagappan ◽  
...  

This study investigated the combine effect of 0.2 % drink cans and steel fibers with volume fractions of 0%, 0.5%, 1%, 1.5%, 2%, 2.5% and 3% to the mechanical properties and impact resistance of concrete. Hooked-end steel fiber with 30 mm and 0.75 mm length and diameter, respectively was selected for this study.  The drinks cans fiber were twisted manually in order to increase friction between fiber and concrete. The results of the experiment showed that the combination of steel fibers and drink cans fibers improved the strength performance of concrete, especially the compressive strength, flexural strength and indirect tensile strength. The results of the experiment showed that the combination of steel fibers and drink cans fibers improved the compressive strength, flexural strength and indirect tensile strength by 2.3, 7, and 2 times as compare to batch 1, respectively. Moreover, the impact resistance of fiber reinforced concrete has increase by 7 times as compared to non-fiber concretes. Moreover, the impact resistance of fiber reinforced concrete consistently gave better results as compared to non-fiber concretes. The fiber reinforced concrete turned more ductile as the dosage of fibers was increased and ductility started to decrease slightly after optimum fiber dosage was reached. It was found that concrete with combination of 2% steel and 0.2% drink cans fibers showed the highest compressive, split tensile, flexural as well as impact strength.    


2021 ◽  
pp. 136943322098165
Author(s):  
Hossein Saberi ◽  
Farzad Hatami ◽  
Alireza Rahai

In this study, the co-effects of steel fibers and FRP confinement on the concrete behavior under the axial compression load are investigated. Thus, the experimental tests were conducted on 18 steel fiber-reinforced concrete (SFRC) specimens confined by FRP. Moreover, 24 existing experimental test results of FRP-confined specimens tested under axial compression are gathered to compile a reliable database for developing a mathematical model. In the conducted experimental tests, the concrete strength was varied as 26 MPa and 32.5 MPa and the steel fiber content was varied as 0.0%, 1.5%, and 3%. The specimens were confined with one and two layers of glass fiber reinforced polymer (GFRP) sheet. The experimental test results show that simultaneously using the steel fibers and FRP confinement in concrete not only significantly increases the peak strength and ultimate strain of concrete but also solves the issue of sudden failure in the FRP-confined concrete. The simulations confirm that the results of the proposed model are in good agreement with those of experimental tests.


Buildings ◽  
2021 ◽  
Vol 11 (2) ◽  
pp. 63
Author(s):  
Anna L. Mina ◽  
Michael F. Petrou ◽  
Konstantinos G. Trezos

The scope of this paper is to investigate the performance of ultra-high performance fiber reinforced concrete (UHPFRC) concrete slabs, under projectile impact. Mixture performance under impact loading was examined using bullets with 7.62 mm diameter and initial velocity 800 m/s. The UHPFRC, used in this study, consists of a combination of steel fibers of two lengths: 6 mm and 13 mm with the same diameter of 0.16 mm. Six composition mixtures were tested, four UHPFRC, one ultra-high performance concrete (UHPC), without steel fibers, and high strength concrete (HSC). Slabs with thicknesses of 15, 30, 50, and 70 mm were produced and subjected to real shotgun fire in the field. Penetration depth, material volume loss, and crater diameter were measured and analyzed. The test results show that the mixture with a combination of 3% 6 mm and 3% of 13 mm length of steel fibers exhibited the best resistance to projectile impact and only the slabs with 15 mm thickness had perforation. Empirical models that predict the depth of penetration were compared with the experimental results. This material can be used as an overlay to buildings or to construct small precast structures.


2017 ◽  
Vol 5 (4RASM) ◽  
pp. 59-62
Author(s):  
Vishal Gadgihalli ◽  
Meena ◽  
Sindu ◽  
Raghavendra Prasad Dinakar

Fiber reinforced concrete is composite material consisting of mixtures of cement, mortar or concrete, discontinuous discrete uniform dispersed suitable fibers. Fiber reinforced concrete are of different types and properties. In this paper analysis of properties of concrete using steel fibre as fiber reinforcement admixture is studied and verified the strength of concrete to normal plane concrete with absence of admixtures. Using steel fibers as fiber reinforcement admixture increases bond strength by enhancing surface tension as steel is better in taking flexural strength this gives better results, hence we can use this steel fiber reinforcement to concrete where the compressive and flexural strength place a crucial role in construction and maintenance.


Author(s):  
Natalia Sharma

Abstract: Reinforced concrete structures are frequently in need of repair and strengthening as a result of numerous environmental causes, ageing, or material damage under intense stress conditions, as well as mistakes made during the construction process. RC structures are repaired using a variety of approaches nowadays. The usage of FRC is one of the retrofitting strategies. Steel fiber reinforced concrete (SFRC) was used in this investigation because it contains randomly dispersed short discrete steel fibers that operate as internal reinforcement to improve the cementitious composite's characteristics (concrete). The main rationale for integrating small discrete fibers into a cement matrix is to reduce the amount of cement used. The principal reason for incorporating short discrete fibers into a cement matrix is to reduce cracking in the elastic range, increase the tensile strength and deformation capacity and increase the toughness of the resultant composite. These properties of SFRC primarily depend upon length and volume of Steel fibers used in the concrete mixture. In India, the steel fiber reinforced concrete (SFRC) has seen limited applications in several structures due to the lack of awareness, design guidelines and construction specifications. Therefore, there is a need to develop information on the role of steel fibers in the concrete mixture. The experimental work reported in this study includes the mechanical properties of concrete at different volume fractions of steel fibers. These mechanical properties include compressive strength, split tensile strength and flexural strength and to study the effect of volume fraction and aspect ratio of steel fibers on these mechanical properties. However, main aim of the study was significance of reinforced concrete beams strengthened with fiber reinforced concrete layer and to investigate how these beams deflect under strain. The objective of the investigation was finding that applying FRC to strengthen beams enhanced structural performance in terms of ultimate load carrying capacity, fracture pattern deflection, and mode of failure or not.


Author(s):  
Josef Landler ◽  
Oliver Fischer

<p>To design flat slabs directly supported on columns, the punching shear resistance of the slab is a main factor. It can be increased in the vicinity of the slab-column connection with punching shear reinforcement, like bent up bars or shear studs, to bear the high reaction forces. However, the usage of punching shear reinforcement requires the knowledge of special design rules and often leads to problems and deficiencies in construction.</p><p>Fiber reinforced concrete seems to be a promising alternative to conventional punching shear reinforcement. To investigate the load bearing behavior of the slab-column connection using fiber reinforced concrete, a total of eight punching shear tests were performed. The specimens were realized with a typical top and bottom flexural reinforcement, but without punching shear reinforcement. Varied parameters were the slab thickness with 250 mm and 300 mm and the fiber content V<sub>f</sub> with 0.5 Vol.-% and 1.0 Vol.-%. To investigate the influence of modern fiber types, normal- and high-strength steel fibers with normal- and double-hooked-ends were used.</p><p>In all eight experimental tests, the intended punching shear failure was achieved. The capable load using fiber reinforced concrete increased by 20 % to 50 % compared to the reference tests without steel fibers, depending on the fiber type and the fiber content V<sub>f</sub>. Additionally, this load increase was accompanied by a significant improvement in ductility. The post-cracking behavior was noticeably influenced by the used steel fiber type. An influence of the slab thickness or steel fiber type on the shear strength contributed by the fiber reinforced concrete could not be determined.</p>


2013 ◽  
Vol 330 ◽  
pp. 77-81
Author(s):  
Yu Chen ◽  
David Bloomquist ◽  
Raphael Crowley

ASTM C78, the Flexural Strength tests were conducted on Cellulose Fiber Reinforced Concrete (CFRC) samples subjected to difference moisture-levels to quantify the effect of moisture on them. Results indicated that modulus elasticity did not change along the increase in moisture. However, flexural strength and yield strength appeared to be affected under certain conditions.


Materials ◽  
2015 ◽  
Vol 8 (4) ◽  
pp. 1442-1458 ◽  
Author(s):  
Seong-Cheol Lee ◽  
Joung-Hwan Oh ◽  
Jae-Yeol Cho

Sign in / Sign up

Export Citation Format

Share Document