scholarly journals Investigation of Wickless Heat Pipe Performance Filled With R134a

2021 ◽  
Vol 23 (11) ◽  
pp. 641-654
Author(s):  
Huthaifa Ahmed Abed ◽  
◽  
Majid H. Majeed ◽  
Ahmad Q. Mohammad ◽  
◽  
...  

The wickless heat pipe (theroosyphon) is ordinate of three divisions the condenser, evaporator and insulated region (adiabatic region). In this work, the condenser and evaporator regions are made of copper tube with a length of 300 mm, for each an exterior diameter of 28.2 mm and an interior diameter of 26.4 mm. While the insulated region has a length of 400 mm and an exterior diameter of 28.2 mm. The evaporator region of the heat pipe bounded by a coiled heat source that represented the heat source. The condenser is encapsulated in a plastic cylinder to accommodate the flow of the cooling water. Thermosyphon has been filled by R- 134a working fluid. The effect of heat input, filling ratio and sink temperature were all tested and measurement. The results showed that the heat transfer performance increases when the applied energy to the evaporator increases while the total heat transfer efficiency of the heat pipe increases the gradient temperature between the medium of the evaporator and the condenser increases. The optimum fill rate is 119 % (250g), the sink temperature is 20°C, and it has been found to be suitable for optimum heat pipe performance.

2003 ◽  
Author(s):  
B. Yu ◽  
C. X. Lin ◽  
M. A. Ebadian ◽  
R. C. Prattipati

This paper presents an experimental investigation of condensation heat transfer and pressure drop characteristics of refrigerant R-134a flowing through an annular helicoidal passage with the hydraulic diameter of 8.5 mm. The angles of helix axis are oriented at 0, 45, 90 degrees to gravity. The overall and refrigerant-side heat transfer coefficients and pressure drops are experimentally determined at saturation temperature 35°C, refrigerant mass flux 35–180 kg/s·m2, and cooling water temperature 27°C. The results show that orientation has significant influence on the thermal and hydraulic behaviors of the helical pipe. The results can be employed for reference in the effective design of annular helicoidal heat exchangers with R-134a as the working fluid.


2021 ◽  
Vol 13 (22) ◽  
pp. 12481
Author(s):  
Jiwen Cen ◽  
Feng Li ◽  
Tingliang Li ◽  
Wenbo Huang ◽  
Juanwen Chen ◽  
...  

The installation and operation of enhanced geothermal systems (EGS) involves many challenges. These challenges include the high cost and high risk associated with the investment capital, potential large working-fluid leakage, corrosion of equipment, and subsiding land. A super-long heat pipe can be used for geothermal exploitation to avoid these problems. In this paper, a high aspect-ratio heat pipe (30 m long, 17 mm in inner diameter) is installed vertically. Experiments are then carried out to study its heat-transfer performance and characteristics using several filling ratios of deionized water, different heating powers, and various cooling-water flowrates. The results show that the optimal filling-ratio is about 40% of the volume of the vaporizing section of the heat pipe. Compared with a conventional short heat pipe, the extra-long heat pipe experiences significant thermal vibration. The oscillation frequency depends on the heating power and working-fluid filling ratio. With increasing cooling-water flow rate, the heat-transfer rate of the heat pipe increases before it reaches a plateau. In addition, we investigate the heat-transfer performance of the heat pipe for an extreme working-fluid filling ratio; the results indicate that the lower part of the heat pipe is filled with vapor, which reduces the heat-transfer to the top part. Based on the experimental data, guidelines for designing a heat pipe that can be really used for the exploitation of earth-deep geothermal energy are analyzed.


2011 ◽  
Vol 133 (9) ◽  
Author(s):  
Chen-Ching Ting ◽  
Chien-Chih Chen

This article presents significant experimental data about the coaxial dual-pipe heat pipe which is invented by our CCT laboratory. The coaxial dual-pipe heat pipe is built-in an inner pipe in the adiabatic section of a common heat pipe. A common heat pipe is composed of three sections: the evaporator section at the one end; the condenser section at the other end; and the adiabatic section in between. The vapor and the liquid phases of the working fluid flow in opposite directions through the core and the wick, respectively. This special heat transfer behavior causes a common heat pipe to yield the discrete heat transfer property. In process, the vapor directly brings large amounts of heat from heat source and rapidly flows through the adiabatic section to the condenser section. This intelligent heat transfer technique lets the heat pipe yield extremely large thermal conductivity. Unfortunately, a heat pipe integrated with cooling fin in the adiabatic section has changed its original heat transfer property. The integrated cooling fin in the adiabatic section has in advance taken heat of the vapor away and caused the vapor to be condensed in the adiabatic section. Therefore, the vapor cannot reach the condenser section and the condenser section hence loses its cooling capability. In other words, the effective cooling length of a common heat pipe which is integrated with cooling fin in the adiabatic section is shortened. The coaxial dual-pipe heat pipe is built-in an inner pipe in the adiabatic section of a common heat pipe to avoid heat of the vapor to be earlier taken away and even condensed in the adiabatic section. Experimental study in this work first built a home-made square coaxial dual-pipe heat pipe integrated with outside isothermal cycling cooling water as the coaxial dual-pipe heat pipe cooler. The home-made square coaxial dual-pipe heat pipe has an observation window. It is convenient to observe change of the two-phase flow inside the heat pipe influenced by the outside cooling water. The results show that the new developed coaxial dual-pipe heat pipe cooler has kept the original heat transfer property of the bare heat pipe. The vapor has reached the condenser section.


2021 ◽  
Vol 29 (1) ◽  
pp. 1-15
Author(s):  
R. Saidur ◽  
Mohammed Ahmed ◽  
Ahmed Qays Abdullah ◽  
Omer A. Alawi ◽  
Balaji Bakthavatchalam ◽  
...  

Nano-refrigerant is announced to become an excellent refrigerant, which often improves heat transfer efficiency in the cooling systems. Different materials can be applied to be suspended in traditional coolants in the same way as nanoparticles. In this comprehensive research, mathematical modeling was used to investigate the effect of suspended nanoparticles (Al2O3, CuO, SiO2 and ZnO) on 1,1,1,2-Tetrafluoroethane, R-134a. The thermal conductivity, dynamic viscosity, density and specific heat capacity of the nano-refrigerant in an evaporator pipe were investigated. Compared to conventional refrigerants, the maximum increase in thermal conductivity was achieved by Al2O3/R-134a (96.23%) at a volume concentration of 0.04. At the same time, all nano-refrigerant types presented the same viscosity enhancement of(45.89%) at the same conditions. These types of complex thermophysical properties have enhanced the heat transfer tendencies in the pipe. Finally, the nano-refrigerant could be a likely working fluid generally used in the cooling unit to improve high-temperature transfer characteristics and save energy use.


Energies ◽  
2021 ◽  
Vol 14 (3) ◽  
pp. 572
Author(s):  
Ching-Jenq Ho ◽  
Shih-Ming Lin ◽  
Chi-Ming Lai

This study explores the effects of pipe wall properties (thermal conductivity k and wall thickness tw) on the heat transfer performance of a rectangular thermosyphon with a phase change material (PCM) suspension and a geometric configuration (aspect ratio = 1; dimensionless heating section length = 0.8; dimensionless relative elevation between the cooling and the heating sections = 2) that ensures the optimum heat transfer efficiency in the cooling section. The following parameter ranges are studied: the dimensionless loop wall thickness (0 to 0.5), wall-to-fluid thermal conductivity ratio (0.1 to 100), modified Rayleigh number (1010 to 1011), and volumetric fraction of PCM particles (0 to 10%). The results show that appropriate selection of k and tw can lead to improved heat transfer effectiveness in the cooling section of the PCM suspension-containing rectangular thermosyphon.


2019 ◽  
Vol 15 (2) ◽  
pp. 452-472 ◽  
Author(s):  
Jayarami Reddy Konda ◽  
Madhusudhana Reddy N.P. ◽  
Ramakrishna Konijeti ◽  
Abhishek Dasore

PurposeThe purpose of this paper is to examine the influence of magnetic field on Williamson nanofluid embedded in a porous medium in the presence of non-uniform heat source/sink, chemical reaction and thermal radiation effects.Design/methodology/approachThe governing physical problem is presented using the traditional Navier–Stokes theory. Consequential system of equations is transformed into a set of non-linear ordinary differential equations by means of scaling group of transformation, which are solved using the Runge–Kutta–Fehlberg method.FindingsThe working fluid is examined for several sundry parameters graphically and in a tabular form. It is noticed that with an increase in Eckert number, there is an increase in velocity and temperature along with a decrease in shear stress and heat transfer rate.Originality/valueA good agreement of the present results has been observed by comparing with the existing literature results.


Author(s):  
Huayi Feng ◽  
Yanping Zhang ◽  
Chongzhe Zou

In this paper, a 3-D numerical model is proposed to investigate the capability of generating high operating temperature for a modified solar cavity receiver in large-scale dish Stirling system. The proposed model aims to evaluate the influence of radiation intensity on the cavity receiver performance. The properties of the heat transfer fluid in the pipe and heat transfer losses of the receiver are investigated by varying the direct normal irradiance from 400W/m2 to 1000W/m2. The temperature of heat transfer fluid, as well as the effect of radiation intensity on the heat transfer losses have been critically presented and discussed. The simulation results reveal that the heat transfer fluid temperature and thermal efficiency of the receiver are significantly influenced by different radiation flux. With the increase of radiation intensity, the efficiency of the receiver will firstly increase, then drops after reaching the highest point. The outlet working fluid temperature of the pipe will be increased consistently. The results of the simulations show that the designed cylindrical receiver used in dish Stirling system is capable to achieve the targeted outlet temperature and heat transfer efficiency, with an acceptable pressure drop.


Author(s):  
Shigeki Hirasawa ◽  
Tatsuya Nakamu ◽  
Tsuyoshi Kawanami ◽  
Katsuaki Shirai

The coupling of the electrocaloric effect in thin films with thermal switches has the potential to be used for efficient refrigeration. We studied the unsteady heat transfer performance and periodic thermal-switching behavior of a flat heat pipe to transfer cold energy from a changing heat source. The condenser of the flat heat pipe was the changing heat source and changed from −20 W to +20 W every 5 s. The temperature of the condenser surface changed in accordance with the heat generation of the heat source. The evaporator was a plate with a mesh wick attached to a water-flow pipe. Cold energy transferred from the condenser surface to the evaporator surface only when the temperature of the condenser surface was lower than that of the evaporator surface. We analyzed the unsteady temperature change and heat transfer performance of the flat heat pipe by numerical simulation. The analytical results showed that it was necessary to have two thermal switches to separate the heat energy and cold energy of the changing heat source. Also, it was important to reduce the thermal resistance and heat capacity of the evaporator surface to improve the unsteady heat transfer performance of the heat pipe. Next, we measured the unsteady heat transfer performance of the flat heat pipe experimentally. The experimental results showed that the thermal-switching behavior was observed when the heat generation of the heat source changed every 5 s.


In this investigation of multi heat pipe induced in heat exchanger shows the developments in heat transfer is to improve the efficiency of heat exchangers. Water is used as a heat transfer fluid and acetone is used as a working fluid. Rotameter is set to measure the flow rate of cold water and hot water. To maintain the parameter as experimental setup. Then set the mass flow rate of hot water as 40 LPH, 60LPH, 80 LPH, 100LPH, 120 LPH and mass flow rate of cold water as 20 LPH, 30 LPH, 40 LPH, 50 LPH, and 60 LPH. Then 40 C, 45 ºC, 50 ºC, 55 C, 60 ºC are the temperatures of hot water at inlet are maintained. To find some various physical parameters of Qc , hc , Re ,, Pr , Rth. The maximum effectiveness of the investigation obtained from condition of Thi 60 C, Tci 32 C and 100 LPH mhi, 60 LPH mci the maximum effectiveness attained as 57.25. Then the mhi as 100 LPH, mci as 60 LPH and Thi at 40 C as 37.6%. It shows the effectiveness get increased about 34.3 to the maximum conditions.


Sign in / Sign up

Export Citation Format

Share Document