scholarly journals Mechanical properties of resin composites containing bioactive glass and experimental nano zinc-silica complex

2021 ◽  
Vol 11 (Suppl. 1) ◽  
pp. 137-142
Author(s):  
Mehmet Gökberkkaan Demirel ◽  
Makbule Tuğba Tunçdemir

Aim: Secondary caries is an important problem in dental composite restoration, and nanoparticles are commonly added to the structures of resin composites to improve their antimicrobial properties. The aim of this study is to evaluate the mechanical properties of composite materials containing bioactive glass (BAG) and an experimental nano zinc-silica (NZS) complex. Methodology: An experimental resin composite containing 70 wt% filler was produced and used as a control sample. This experimental resin composite was then modified by adding different amounts of BAG (10%), NZS (10%), and both BAG and NZS (10% + 10%). NZS was synthesized in situ by milling zinc and silica to nanoscale level. Compressive strength and flexural strength were investigated using a universal testing machine. Data were analyzed using one-way ANOVA and the Tukey post-hoc test. Results: There were no statistically significant differences in compressive strength caused by the filler amount, but statistically significant changes were found in flexural strength. Although the addition of antimicrobial agents to resin composites reduces their physical properties, this is not a clinically unacceptable limit. Conclusion: NZS exhibits better mechanical properties than does BAG, but both materials can be used safely in restorative materials.   How to cite this article: Tunçdemir MT, Demirel MG. Mechanical properties of resin composites containing bioactive glass and experimental nano zinc-silica complex. Int Dent Res 2021;11(Suppl.1):137-42. https://doi.org/10.5577/intdentres.2021.vol11.suppl1.21   Linguistic Revision: The English in this manuscript has been checked by at least two professional editors, both native speakers of English.  

2021 ◽  
Vol 9 (02) ◽  
pp. 104-110
Author(s):  
Akshay Punjabi ◽  
◽  
Rahul Rao ◽  
Ashish K. Jain ◽  
Meenakshi Verma ◽  
...  

Context:The quality of light curing units can profoundly influence mechanical properties of dental composite materials. Aim: To compare effect of Woodpecker RTA Mini-S and Elipar Deep Cure-L curing units onmechanical properties (compressive strength, diametral tensile strength and microhardness) of Filtek Bulk-Fill. Methods and Materials: A total of 32 samples of Filtek Bulk Fill composite were divided into 2 equal groups (n=16). 12 samples in each group were fabricated using a tooth shaped mold and 4 in circular rings to test compressive strength, microhardness and diametral tensile strength, respectively. Theblocks were evaluated for the above parameters using Universal Testing Machine and Vickers Microhardness Tester.Independent sample-t test was used in this study (p< 0.05). Results: The results of this study showed that the group of composites cured using Elipar Deep Cure-L curing unit showed better mechanical properties and the difference between the groups was statistically significant for compressive strength and diametral tensile strength (p < 0.05) Conclusion: It was concluded that a curing unit of higher intensity and quality of output used in conjugation with bulk fill composites are likely to give better results.


Materials ◽  
2020 ◽  
Vol 13 (6) ◽  
pp. 1477 ◽  
Author(s):  
Ioana-Codruţa Mirică ◽  
Gabriel Furtos ◽  
Bogdan Bâldea ◽  
Ondine Lucaciu ◽  
Aranka Ilea ◽  
...  

The aim of this study was to evaluate the correlation between the percent of inorganic filler by weight (wt. %) and by volume (vol. %) of 11 flowable resin composites (FRCs) and their mechanical properties. To establish the correlation, the quantity of inorganic filler was determined by combustion and shape/size analyzed by SEM images. The compressive strength (CS), flexural strength (FS), and flexural modulus (FM) were determined. The CS values were between 182.87-310.38 MPa, the FS values ranged between 59.59 and 96.95 MPa, and the FM values were between 2.34 and 6.23 GPa. The percentage of inorganic filler registered values situated between 52.25 and 69.64 wt. % and 35.35 and 53.50 vol. %. There was a very good correlation between CS, FS, and FM vs. the inorganic filler by wt. % and vol. %. (R2 = 0.8899–0.9483). The highest regression was obtained for the FM values vs. vol. %. SEM images of the tested FRCs showed hybrid inorganic filler for Filtek Supreme XT (A3) and StarFlow (A2) and a homogeneous type of inorganic filler for the other investigated materials. All of the FS values were above 50 MPa, the ISO 4049/2019 limit for FRCs.


2021 ◽  
Vol 58 (2) ◽  
pp. 80-90
Author(s):  
Branislava Petronijevic Sarcev ◽  
Danka Labus Zlatanovic ◽  
Miroslav Hadnadjev ◽  
Branka Pilic ◽  
Ivan Sarcev ◽  
...  

The aim of this work was to find the influence of the addition of low amount of hydrophilic and hydrophobic TiO2 nanoparticles on compressive strength, microhardness and rheological properties of flowable dental composite material. Specimens were prepared by adding 0.05; 0.2 and 1 wt. % of hydrophilic and hydrophobic 20 nm TiO2 nanoparticles. These specimens were compared to non-modified control specimens in compressive strength and microhardness. Furthermore, their rheological properties were determined. The optimal nanoparticle loading was 0.2 % hydrophobic TiO2, resulting in significantly higher compressive strength and microhardness than those of the control specimen group. Mechanical properties of flowable composites reinforced with hydrophilic and hydrophobic TiO2 at higher loadings are lower than those of control specimens, which is the result of nanoparticle agglomeration. TiO2 nanoparticles addition resulted in the decrease in viscosity in all specimens except for the specimewn with 1% hydrophilic TiO2 nanoparticles. In accordance to the obtained results, hydrophobic nanoparticle addition results in a more resistant and durable material, combined with an increased flowability compared to a non-modified composite.


2017 ◽  
Vol 42 (6) ◽  
pp. E177-E187 ◽  
Author(s):  
S Shibasaki ◽  
T Takamizawa ◽  
K Nojiri ◽  
A Imai ◽  
A Tsujimoto ◽  
...  

SUMMARY The present study determined the mechanical properties and volumetric polymerization shrinkage of different categories of resin composite. Three high viscosity bulk fill resin composites were tested: Tetric EvoCeram Bulk Fill (TB, Ivoclar Vivadent), Filtek Bulk Fill posterior restorative (FB, 3M ESPE), and Sonic Fill (SF, Kerr Corp). Two low-shrinkage resin composites, Kalore (KL, GC Corp) and Filtek LS Posterior (LS, 3M ESPE), were used. Three conventional resin composites, Herculite Ultra (HU, Kerr Corp), Estelite ∑ Quick (EQ, Tokuyama Dental), and Filtek Supreme Ultra (SU, 3M ESPE), were used as comparison materials. Following ISO Specification 4049, six specimens for each resin composite were used to determine flexural strength, elastic modulus, and resilience. Volumetric polymerization shrinkage was determined using a water-filled dilatometer. Data were evaluated using analysis of variance followed by Tukey's honestly significant difference test (α=0.05). The flexural strength of the resin composites ranged from 115.4 to 148.1 MPa, the elastic modulus ranged from 5.6 to 13.4 GPa, and the resilience ranged from 0.70 to 1.0 MJ/m3. There were significant differences in flexural properties between the materials but no clear outliers. Volumetric changes as a function of time over a duration of 180 seconds depended on the type of resin composite. However, for all the resin composites, apart from LS, volumetric shrinkage began soon after the start of light irradiation, and a rapid decrease in volume during light irradiation followed by a slower decrease was observed. The low shrinkage resin composites KL and LS showed significantly lower volumetric shrinkage than the other tested materials at the measuring point of 180 seconds. In contrast, the three bulk fill resin composites showed higher volumetric change than the other resin composites. The findings from this study provide clinicians with valuable information regarding the mechanical properties and polymerization kinetics of these categories of current resin composite.


2019 ◽  
Vol 22 (2) ◽  
pp. 234-242
Author(s):  
Aylin Cilingir ◽  
Alev Ozsoy ◽  
Meltem Mert Eren ◽  
Ozge Behram ◽  
Benin Dikmen ◽  
...  

Objective: The objective of this study was to evaluate the compressive strength, flexural strength and flexural modulus of high-viscosity, low-viscosity bulk-fill, and conventional nano-hybrid resin composite materials alone and when covered with nano-hybrid resin composite at different incremental thicknesses on the bulk-fill composites. Materials and Methods: Specimens (N=60) were fabricated from the following materials or their combinations (n=10 per group): a) conventional nano-hybrid composite Z550 (FK), b) high-viscosity bulk-fill composite (Tetric N Ceram-TBF), c) low-viscosity bulk-fill composite SDR (SDR), d) Sonicfill (SF), e) SDR (2 mm)+FK (2 mm), f) SDR (4 mm)+FK (4 mm). After 24 h water storage, compressive strength was measured in a universal testing machine (1 mm/min). Additional specimens (N=40) (25x2x2 mm3) were made from FK, TBF, SDR and SF in order to determine the flexural strength and the flexural modulus, (n=10) and subjected to three-point bending test (0.5 mm/min). Data were analyzed using one-way ANOVA and Tamhane’s T2 post-hoc tests (p<0.05). Results: The mean compressive strength (MPa) of the nano-hybrid composite (FK) was significantly higher (223.8±41.3) than those of the other groups (123±27 - 170±24) (p<0.001). SDR (4 mm)+FK (2 mm) showed significantly higher compressive strength than when covered with 4 mm (143±30) or when used alone (146±11) (p<0.05). The mean flexural strength (159±31) and the flexural modulus of FK (34±7) was significantly higher than that of the high- or low-viscosity bulk-fill composites (p<0.001). The mean flexural strength of SF (132±20) was significantly higher compared to TBF (95±25) (p<0.05). Conclusion: Bulk-fill resin composites demonstrated poorer mechanical properties compared to nano-hybrid composite but similar to that of SF. Increasing the thickness of low-viscosity bulk-fill composite (SDR) from 2 to 4 mm underneath the nano-hybrid composite (FK) can improve the mechanical properties of the bulk-fill composites. KeywordsBulk-fill composites; Compressive strength; Flexural modulus; Flexural strength; Mechanical properties.


2015 ◽  
Vol 1124 ◽  
pp. 51-56 ◽  
Author(s):  
Martina Drdlová ◽  
Michal Frank ◽  
Jaroslav Buchar ◽  
Radek Řídký

The effect of multi-wall carbon nanotubes and nanoSiO2content on physico-mechanical properties of glass microspheres-epoxy resin composite, designed for blast energy absorbing applications, was evaluated experimentally. Specific porous lightweight foam with high volume fraction of microspheres (70 vol.%) was prepared and modified by 1 to 5 vol.% of multi-wall carbon nanotubes and nanosilica (nanoSiO2). Two types of microsperes with different wall thickness and strength were used. The quality of dispersion of nanoparticles was evaluated in relation to the mixing procedure using scanning electron microscope observation. The compressive and flexural strength tests were conducted at quasi-static load. The mixtures containing nanosilica exhibited an increasing trend in both flexural and compressive strength with increasing nanoparticle content up to 4 vol.%. The addition of carbon nanotubes also increased flexural strength (again up to 4 vol%, crossing this concentration, the significant drop was observed), whereas the compressive strength was affected at lower level. Nanoparticle modification is more effective in the foams with higher thickness and thus strength. The evaluation of test results showed that the properties of glass/epoxy foams can be tailored by adding nanoscale fillers.


2021 ◽  
Vol 13 (8) ◽  
pp. 4546
Author(s):  
Kaiyue Zhao ◽  
Peng Zhang ◽  
Bing Wang ◽  
Yupeng Tian ◽  
Shanbin Xue ◽  
...  

Cement-based materials prepared with activated water induced by a magnetic field or electric field represent a possible solution to environmental issues caused by the worldwide utilization of chemical admixtures. In this contribution, electric- and magnetic-activated water have been produced. The workability and mechanical properties of cement mortar prepared with this activated water have been investigated. The results indicate that the pH and absorbance (Abs) values of the water varied as the electric and magnetic field changed, and their values increased significantly, exhibiting improved activity compared with that of the untreated water. In addition, activated water still retains activity within 30 min of the resting time. The fluidity of the cement paste prepared with electric-activated water was significantly larger than that of the untreated paste. However, the level of improvement differed with the worst performance resulting from cement paste prepared with alternating voltage activated water. In terms of mechanical properties, both compressive strength and flexural strength obtained its maximum values at 280 mT with two processing cycles. The compressive strength increased 26% as the curing time increased from 7 days to 28 days and flexural strength increased by 31%. In addition, through the introduction of magnetic-activated water into cement mortar, the mechanical strength can be maintained without losing its workability when the amount of cement is reduced.


2021 ◽  
Vol 11 (7) ◽  
pp. 3032
Author(s):  
Tuan Anh Le ◽  
Sinh Hoang Le ◽  
Thuy Ninh Nguyen ◽  
Khoa Tan Nguyen

The use of fluid catalytic cracking (FCC) by-products as aluminosilicate precursors in geopolymer binders has attracted significant interest from researchers in recent years owing to their high alumina and silica contents. Introduced in this study is the use of geopolymer concrete comprising FCC residue combined with fly ash as the requisite source of aluminosilicate. Fly ash was replaced with various FCC residue contents ranging from 0–100% by mass of binder. Results from standard testing methods showed that geopolymer concrete rheological properties such as yield stress and plastic viscosity as well as mechanical properties including compressive strength, flexural strength, and elastic modulus were affected significantly by the FCC residue content. With alkali liquid to geopolymer solid ratios (AL:GS) of 0.4 and 0.5, a reduction in compressive and flexural strength was observed in the case of geopolymer concrete with increasing FCC residue content. On the contrary, geopolymer concrete with increasing FCC residue content exhibited improved strength with an AL:GS ratio of 0.65. Relationships enabling estimation of geopolymer elastic modulus based on compressive strength were investigated. Scanning electron microscope (SEM) images and X-ray diffraction (XRD) patterns revealed that the final product from the geopolymerization process consisting of FCC residue was similar to fly ash-based geopolymer concrete. These observations highlight the potential of FCC residue as an aluminosilicate source for geopolymer products.


Materials ◽  
2021 ◽  
Vol 14 (11) ◽  
pp. 2769
Author(s):  
Jonne Oja ◽  
Lippo Lassila ◽  
Pekka K. Vallittu ◽  
Sufyan Garoushi

The aim of current in vitro research was to determine the effect of hydrothermal accelerated aging on the mechanical properties and wear of different commercial dental resin composites (RCs). In addition, the effect of expiration date of the composite prior its use was also evaluated. Five commercially available RCs were studied: Conventional RCs (Filtek Supreme XTE, G-aenial Posterior, Denfil, and >3y expired Supreme XTE), bulk-fill RC (Filtek Bulk Fill), and short fiber-reinforced RC (everX Posterior). Three-point flexural test was used for determination of ultimate flexural strength (n = 8). A vickers indenter was used for testing surface microhardness. A wear test was conducted with 15,000 chewing cycles using a dual-axis chewing simulator. Wear pattern was analyzed by a three-dimensional (3D) noncontact optical profilometer. Degree of C=C bond conversion of monomers was determined by FTIR-spectrometry. The specimens were either dry stored for 48 h (37 °C) or boiled (100 °C) for 16 h before testing. Scanning electron microscopy (SEM) was used to evaluate the microstructure of each material. Data were analyzed using ANOVA (p = 0.05). Hydrothermal aging had no significant effects on the surface wear and microhardness of tested RCs (p > 0.05). While flexural strength significantly decreased after aging (p < 0.05), except for G-aenial Posterior, which showed no differences. The lowest average wear depth was found for Filtek Bulk Fill (29 µm) (p < 0.05), while everX Posterior and Denfil showed the highest wear depth values (40, 39 µm) in both conditions. Passing the expiration date for 40 months did not affect the flexural strength and wear of tested RC. SEM demonstrated a significant number of small pits on Denfil’s surface after aging. It was concluded that the effect of accelerated aging may have caused certain weakening of the RC of some brands, whereas no effect was found with one brand of RC. Thus, the accelerated aging appeared to be more dependent on material and tested material property.


Materials ◽  
2021 ◽  
Vol 14 (5) ◽  
pp. 1303
Author(s):  
Michael Seidenstuecker ◽  
Thomas Schmeichel ◽  
Lucas Ritschl ◽  
Johannes Vinke ◽  
Pia Schilling ◽  
...  

This work aimed to determine the influence of two hydrogels (alginate, alginate-di-aldehyde (ADA)/gelatin) on the mechanical strength of microporous ceramics, which have been loaded with these hydrogels. For this purpose, the compressive strength was determined using a Zwick Z005 universal testing machine. In addition, the degradation behavior according to ISO EN 10993-14 in TRIS buffer pH 5.0 and pH 7.4 over 60 days was determined, and its effects on the compressive strength were investigated. The loading was carried out by means of a flow-chamber. The weight of the samples (manufacturer: Robert Mathys Foundation (RMS) and Curasan) in TRIS solutions pH 5 and pH 7 increased within 4 h (mean 48 ± 32 mg) and then remained constant over the experimental period of 60 days. The determination surface roughness showed a decrease in the value for the ceramics incubated in TRIS compared to the untreated ceramics. In addition, an increase in protein concentration in solution was determined for ADA gelatin-loaded ceramics. The macroporous Curasan ceramic exhibited a maximum failure load of 29 ± 9.0 N, whereas the value for the microporous RMS ceramic was 931 ± 223 N. Filling the RMS ceramic with ADA gelatin increased the maximum failure load to 1114 ± 300 N. The Curasan ceramics were too fragile for loading. The maximum failure load decreased for the RMS ceramics to 686.55 ± 170 N by incubation in TRIS pH 7.4 and 651 ± 287 N at pH 5.0.


Sign in / Sign up

Export Citation Format

Share Document