scholarly journals Indoor Human Thermal Comfort Optimal Control with Desiccant Wheel Cooling System

2014 ◽  
Vol 61 ◽  
pp. 882-886
Author(s):  
Nan Wang ◽  
Xiaohua Xia
Author(s):  
Ankit Jain ◽  
Amitesh Paul ◽  
G.L. Selokar

Desiccant cooling technology can be used to solve a variety of building comfort, quality and energy related issues. The main objective of my research work was to assess the feasibilities of utilization of solar energy for regeneration of desiccant wheel by hot air provided by solar air heater. It will help in saving electrical energy for regeneration of desiccant wheel.


Author(s):  
Ali M. Baniyounes ◽  
Yazeed Y. Ghadi

<p>Indoor air quality as always is the centre of attention for researchers, architect developers and public health officials. As every-one know. The human exposure to a variety of indoor pollutants and the high cost of energy are the motivation for these kinds of studies. Fungus and mould growth has always been a problem in subtropical climate areas due to the high temperature and high humidity. Generally in institutional buildings, most of the internal heat load is generated by human body and thermal comfort is achieved with   extensive usage of recycled air and air conditioning. The main considerations in any air conditioning system economisers are based on the usage of recycled air and air ventilation. The current practice in an institutional building cooling system under subtropical climate is to curb the mould issue by overcooling large recirculation airflow to remove the moisture content from the air, which is considered as an expensive practice. The use of a solar desiccant cooling system to reduce moisture from the air and to improve indoor air quality is found to be economical, environmental friendly and readily achievable in the tropics. This technology is the future alternative to the conventional vapour compression cooling system to maintain human thermal comfort conditions and enhance indoor air quality. Solar desiccant cooling systems are also environmentally friendly and energy efficient. This paper presents review on a solar desiccant cooling system and its effect on indoor air quality. It first introduces the issue of air moisture, mould growth and indoor air quality and then the development and application of thermally activated desiccant cooling technologies.</p>


Author(s):  
Elise Belleil ◽  
Long Phan ◽  
Cheng-Xian Lin ◽  
Mirko Schäfer ◽  
Johannes Wagner

The solar powered house at the Engineering Center of Florida International University is out of the U.S. Solar Decathlon 2005 competition. A computational simulation using EnergyPlus is conducted to study different ventilation strategies in this solar house model, with consideration of the hot and humid climate in Miami, Florida. Several modes of ventilation including mechanical cooling systems, natural ventilation utilization, and hybrid systems were considered to seek the best possible option for ventilation in such extreme climate. While the need for a mechanical ventilation system is always present, a resort to natural ventilation could significantly reduce energy consumption. As for natural ventilation utilization, a few methods including earth tubes (ET), thermal chimneys (TC), cooling towers (CT), and openings have been simulated and compared with the mechanical cooling system of the original house. However, as the simulation results suggested, relying on only natural ventilation could cause a dramatic impact to the human thermal comfort. Therefore, a coupling strategy between mechanical systems and natural ventilation was extensively investigated in hope for a better solution in terms of both energy consumption and thermal comfort. In fact, the hybrid system has proved to tremendously reduce energy consumption while complying with the minimum requirements for thermal comfort recommended by ASHRAE standards.


The liquid desiccant cooling system is found to be a good alternative of conventional air conditioning system for better control of both latent and sensible loads. The major component of a liquid desiccant cooling system is desiccant dehumidifier which controls the latent cooling load. In this paper a mathematical model for rotary type liquid desiccant dehumidifier commonly known as desiccant wheel has been presented. The desiccant wheel has a cylindrical shape with a number of identical narrow circular slots distributed uniformly over the rotor cross section. The slots are filled with a porous medium carrying the solution of liquid desiccant, to make the absorbing surface. The absorption and regeneration performance of the desiccant dehumidifier is discussed in this paper for different operating conditions. The wheel performance curves which help to determine the air outlet conditions and coefficient of performance (COP) of the system are drawn for a wide range of wheel thickness (0.06-0.6m), air mass flux (1-8 kg/m2 .s), and regeneration temperature (60- 85o C). A reduction of about 30% in outlet humidity ratio is observed with an increase in the wheel thickness from 0.06 to 0.2m. The computed results show that better supply air conditions can be obtained to provide human thermal comfort in the hot and humid climate with effectiveness of the system largely dependent on air flow rate, wheel thickness and humidity ratio of process air.


ICCREM 2020 ◽  
2020 ◽  
Author(s):  
Boshuai Dong ◽  
Chunjing Shang ◽  
Ming Tong ◽  
Jianhong Cai

2017 ◽  
Vol 16 (9) ◽  
pp. 2097-2111 ◽  
Author(s):  
Mohanadoss Ponraj ◽  
Yee Yong Lee ◽  
Mohd Fadhil Md Din ◽  
Zainura Zainon Noor ◽  
Kenzo Iwao ◽  
...  

Energies ◽  
2020 ◽  
Vol 13 (12) ◽  
pp. 3061 ◽  
Author(s):  
Shazia Noor ◽  
Hadeed Ashraf ◽  
Muhammad Sultan ◽  
Zahid Mahmood Khan

This study provides comprehensive details of evaporative cooling options for building air-conditioning (AC) in Multan (Pakistan). Standalone evaporative cooling and standalone vapor compression AC (VCAC) systems are commonly used in Pakistan. Therefore, seven AC system configurations comprising of direct evaporative cooling (DEC), indirect evaporative cooling (IEC), VCAC, and their possible combinations, are explored for the climatic conditions of Multan. The study aims to explore the optimum AC system configuration for the building AC from the viewpoints of cooling capacity, system performance, energy consumption, and CO2 emissions. A simulation model was designed in DesignBuilder and simulated using EnergyPlus in order to optimize the applicability of the proposed systems. The standalone VCAC and hybrid IEC-VCAC & IEC-DEC-VCAC system configurations could achieve the desired human thermal comfort. The standalone DEC resulted in a maximum COP of 4.5, whereas, it was 2.1 in case of the hybrid IEC-DEC-VCAC system. The hybrid IEC-DEC-VCAC system achieved maximum temperature gradient (21 °C) and relatively less CO2 emissions as compared to standalone VCAC. In addition, it provided maximum cooling capacity (184 kW for work input of 100 kW), which is 85% higher than the standalone DEC system. Furthermore, it achieved neutral to slightly cool human thermal comfort i.e., 0 to −1 predicted mean vote and 30% of predicted percentage dissatisfied. Thus, the study concludes the hybrid IEC-DEC-VCAC as an optimum configuration for building AC in Multan.


2021 ◽  
Vol 13 (2) ◽  
pp. 983
Author(s):  
Mustapha Mukhtar ◽  
Bismark Ameyaw ◽  
Nasser Yimen ◽  
Quixin Zhang ◽  
Olusola Bamisile ◽  
...  

The world has not been able to achieve minimum greenhouse gas emissions in buildings’ energy consumptions because the energy and emissions optimization techniques have not been fully utilized. Thermal comfort is one of the most important issues for both residential and commercial buildings. Out of the 40% of global energy consumed by buildings, a large fraction is used to maintain their thermal comfort. In this study, a comprehensive review of the recent advancements in building energy conservation and efficiency application is presented based on existing high-quality research papers. Additionally, the retrofit of the heating/cooling and hot water system for an entire community in Cyprus is presented. This study aims to analyze the technical and environmental benefits of replacing existing electric heaters for hot water with heat pump water heating systems and the use of heat pump air conditioners for thermal comfort in place of the existing ordinary air conditioners for space heating and cooling. One administrative building, 86 apartments (including residential and commercial) buildings, and a restaurant building is retrofitted, and the feasibility of the project is determined based on three economic indicators, namely; simple payback period (SPP), internal rate of return (IRR), and net present value (NPV). The electrical energy required by the hot water systems and the heating/cooling system is reduced by 263,564 kWh/yr and 144,825 kWh/yr, respectively. Additionally, the retrofit project will reduce Cyprus’ CO2 emission by 121,592.8 kg yearly. The SPP, IRR, and NPV for the project show that the retrofit is economically feasible.


2021 ◽  
Vol 11 (7) ◽  
pp. 3236
Author(s):  
Ji Hyeok Kim ◽  
Joon Ahn

In a field test of a hybrid desiccant cooling system (HDCS) linked to a gas engine cogeneration system (the latter system is hereafter referred to as the combined heat and power (CHP) system), in the cooling operation mode, the exhaust heat remained and the latent heat removal was insufficient. In this study, the performance of an HDCS was simulated at a humidity ratio of 10 g/kg in conditioned spaces and for an increasing dehumidification capacity of the desiccant rotor. Simulation models of the HDCS linked to the CHP system were based on a transient system simulation tool (TRNSYS). Furthermore, TRNBuild (the TRNSYS Building Model) was used to simulate the three-dimensional structure of cooling spaces and solar lighting conditions. According to the simulation results, when the desiccant capacity increased, the thermal comfort conditions in all three conditioned spaces were sufficiently good. The higher the ambient temperature, the higher the evaporative cooling performance was. The variation in the regeneration heat with the outdoor conditions was the most dominant factor that determined the coefficient of performance (COP). Therefore, the COP was higher under high temperature and dry conditions, resulting in less regeneration heat being required. According to the prediction results, when the dehumidification capacity is sufficiently increased for using more exhaust heat, the overall efficiency of the CHP can be increased while ensuring suitable thermal comfort conditions in the cooling space.


Sign in / Sign up

Export Citation Format

Share Document