Effects of Fe3O4/Water Nanofluid on the Efficiency of a Curved Pipe

Author(s):  
Milad Kelidari ◽  
Ali Jabari Moghadam

Different-radius of curvature pipes are experimentally investigated using distilled water and Fe3O4–water nanofluid with two different values of the nanoparticle volume fraction as the working fluids. The mass flow rate is approximately varied from 0.2 to 0.7 kg/min (in the range of laminar flow); the wall heat flux is nearly kept constant. The experimental results reveal that utilizing the nanofluid increases the convection heat transfer coefficient and Nusselt number in comparison to water; these outcomes are also observed when the radius of curvature is decreased and/or the mass flow rate is increased (equivalently, a rise in Dean number). The resultant pressure gradient is, however, intensified by an increase in the volume concentration of nanoparticles and/or by a rise in Dean number. For any particular working fluid, there is an optimum mass flow rate, which maximizes the system efficiency. The overall efficiency can be introduced to include hydrodynamic as well as thermal characteristics of nanofluids in various geometrical conditions. For each radius of curvature, the same overall efficiency may be achieved for two magnitudes of nanofluid volume concentration.

2021 ◽  
Vol 9 (1) ◽  
Author(s):  
Hannah R. Doran ◽  
Theo Renaud ◽  
Gioia Falcone ◽  
Lehua Pan ◽  
Patrick G. Verdin

AbstractAlternative (unconventional) deep geothermal designs are needed to provide a secure and efficient geothermal energy supply. An in-depth sensitivity analysis was investigated considering a deep borehole closed-loop heat exchanger (DBHE) to overcome the current limitations of deep EGS. A T2Well/EOS1 model previously calibrated on an experimental DBHE in Hawaii was adapted to the current NWG 55-29 well at the Newberry volcano site in Central Oregon. A sensitivity analysis was carried out, including parameters such as the working fluid mass flow rate, the casing and cement thermal properties, and the wellbore radii dimensions. The results conclude the highest energy flow rate to be 1.5 MW, after an annulus radii increase and an imposed mass flow rate of 5 kg/s. At 3 kg/s, the DBHE yielded an energy flow rate a factor of 3.5 lower than the NWG 55-29 conventional design. Despite this loss, the sensitivity analysis allows an assessment of the key thermodynamics within the wellbore and provides a valuable insight into how heat is lost/gained throughout the system. This analysis was performed under the assumption of subcritical conditions, and could aid the development of unconventional designs within future EGS work like the Newberry Deep Drilling Project (NDDP). Requirements for further software development are briefly discussed, which would facilitate the modelling of unconventional geothermal wells in supercritical systems to support EGS projects that could extend to deeper depths.


In this investigation of multi heat pipe induced in heat exchanger shows the developments in heat transfer is to improve the efficiency of heat exchangers. Water is used as a heat transfer fluid and acetone is used as a working fluid. Rotameter is set to measure the flow rate of cold water and hot water. To maintain the parameter as experimental setup. Then set the mass flow rate of hot water as 40 LPH, 60LPH, 80 LPH, 100LPH, 120 LPH and mass flow rate of cold water as 20 LPH, 30 LPH, 40 LPH, 50 LPH, and 60 LPH. Then 40 C, 45 ºC, 50 ºC, 55 C, 60 ºC are the temperatures of hot water at inlet are maintained. To find some various physical parameters of Qc , hc , Re ,, Pr , Rth. The maximum effectiveness of the investigation obtained from condition of Thi 60 C, Tci 32 C and 100 LPH mhi, 60 LPH mci the maximum effectiveness attained as 57.25. Then the mhi as 100 LPH, mci as 60 LPH and Thi at 40 C as 37.6%. It shows the effectiveness get increased about 34.3 to the maximum conditions.


Micromachines ◽  
2020 ◽  
Vol 11 (8) ◽  
pp. 758
Author(s):  
Zhi-xin Gao ◽  
Ping Liu ◽  
Yang Yue ◽  
Jun-ye Li ◽  
Hui Wu

Although check valves have attracted a lot of attention, work has rarely been completed done when there is a compressible working fluid. In this paper, the swing check valve and the tilting check valve flowing high-temperature compressible water vapor are compared. The maximum Mach number under small valve openings, the dynamic opening time, and the hydrodynamic moment acting on the valve disc are chosen to evaluate the difference between the two types of check valves. Results show that the maximum Mach number increases with the decrease in the valve opening and the increase in the mass flow rate, and the Mach number and the pressure difference in the tilting check valve are higher. In the swing check valve, the hydrodynamic moment is higher and the valve opening time is shorter. Furthermore, the valve disc is more stable for the swing check valve, and there is a periodical oscillation of the valve disc in the tilting check valve under a small mass flow rate.


Author(s):  
A. Whitfield

A procedure is described which develops the non-dimensional design of a radial inflow turbine rotor. The design is developed, for any specified non-dimensional power ratio, with the objective of minimising the inlet and discharge Mach numbers so that the passage losses are minimised. Initially state of the art efficiencies are assumed but are later modified through the specification of empirical losses. The resultant non-dimensional design can be transformed to absolute dimensions through the specification of the inlet stagnation conditions and the mass flow rate of the working fluid.


1990 ◽  
Vol 112 (1) ◽  
pp. 50-57 ◽  
Author(s):  
A. Whitfield

A procedure is described that develops the nondimensional design of a radial inflow turbine rotor. The design is developed, for any specified nondimensional power ratio, with the objective of minimizing the inlet and discharge Mach numbers so that the passage losses are minimized. Initially state-of-the-art efficiencies are assumed, but these are later modified through the specification of empirical losses. The resultant nondimensional design can be transformed to absolute dimensions through the specification of the inlet stagnation conditions and the mass flow rate of the working fluid.


Author(s):  
Ying Zhang ◽  
Arun Kumar Narasimhan ◽  
Mengjie Bai ◽  
Li Zhao ◽  
Shuai Deng ◽  
...  

Abstract Solar driven ORC system is a possible solution for small-scale power generation. A scroll expander is considered due to its better suitability among other positive displacement expanders for small-scale power outputs. This work conducted a test of an ORC system with an expansion valve by varying the working fluid mass flow rate in two scenarios. A dynamic system-level model of ORC was developed and validated with experimental data. The validated model was used to predict the ORC performance considering off-design conditions of expander and solar insolation. The experimental data showed that pressures and temperatures exhibited the same trend as that of the working fluid mass flow rate, of which the evaporation pressure was the most sensitive to this variation. The simulation results are in good agreement with the experimental results. Results from the dynamic model showed that the ORC power output was underestimated by up to 54.7%, when off-design performance of expander was not considered. Considering the expander off-design performance and solar insolation, a highest thermal efficiency of 7.6% and an expander isentropic efficiency of 80.6% were achieved.


Author(s):  
Muhammad Ali Kamran ◽  
Shahryar Manzoor

A comprehensive experimental study on the effects of different operating parameters on the efficiency of tesla turbine is reported. A bladeless turbine with nine discs and up to four turbine inlets was used, with water as the working fluid. The parameters investigated are the nozzle angle, number of turbine inlets and mass flow rates. Contrary to earlier studies, an effort was made to determine the performance under varying loading conditions, and hence identify the complete performance characteristics. The study revealed that efficiency of the turbine increases at lower nozzle angles and higher number of turbine inlets. It was observed that the nozzle angle becomes a significant parameter when the number of turbine inlets is increased. Efficiencies up to 78% were achieved when the working fluid entered the turbine through two nozzles at an angle of 7°. It was also noted that the turbine is most efficient at the designed mass flow rate, and the efficiency reduces appreciably if lower mass flow rates are fed to the turbine. The results obtained are an important contribution to the available knowledge and can be used as design references for further studies.


2020 ◽  
pp. 60-64
Author(s):  
R. A. Korneev ◽  
A. R. Tukhvatullin ◽  
V. A. Fafurin ◽  
R. R. Nigmatullin ◽  
A. V. Shchelchkov

The publication presents an experimental method for estimating the minimum time interval for filling a storage tank with a working fluid with a fixed geometry of the nozzle of the flow switch of the calibration plant when playing units of mass and volume of fluid in the flow, mass and volumetric flow rates of the fluid. Experimental studies were performed in a wide range of mass flow rate 11,10–83,26 kg/s (40–300 t/h) with repeated static weighing of the working fluid. The flow switch is made with a fixed geometry of the flow part of the nozzle exit, which is typical for a large number of calibration units in use in our country with weighing devices. The graphical dependences of the mass flow rate on the time of filling the storage capacity obtained from the research results are the basis for optimizing the process of reproducing units of mass and volume of liquid in the flow, mass and volumetric flow rates of the liquid for calibration plants with weighing devices. These graphical dependencies made it possible to formulate recommendations on the reasonable choice of the minimum interval for filling the storage tank with working fluid in the studied range of mass flow rate. Optimization has been tested and can be extended to calibration units with weighing devices from various manufacturers with individual design and operating parameters.


2011 ◽  
Vol 110-116 ◽  
pp. 3657-3662
Author(s):  
S. Alikhani ◽  
A. Behzadmehr ◽  
S. Mirmasoumi

Fully developed laminar mixed convection of a nanofluid (water/Al2O3) in a horizontal curved tube is numerically investigated. Three-dimensional elliptic governing equations have been solved to show how nanoparticle concentration affects on thermal and hydrodynamic parameters while these parameters are impressed by centrifugal and buoyancy forces under constant mass flow rate and heat flux. Comparisons with previously published experimental works on horizontal curved tubes show good agreements between the results. Results which are obtained using the two – phase mixture model indicate that adding the nanoparticles causes changes in the properties of nanofluid and finally increases the temperature of the flow. Furthermore, increasing nanoparticles volume fraction at first augments the heat transfer coefficient of nanofluid and then, for higher concentration of particles, decreases this thermal parameter of nanofluid.


Energies ◽  
2020 ◽  
Vol 13 (9) ◽  
pp. 2203 ◽  
Author(s):  
Hwi-Ung Choi ◽  
Kwang-Hwan Choi

In the present work, the electrical and thermal performances of a newly designed PV/T (photovoltaic/thermal) air collector, which was proposed and fabricated by the author, have been investigated experimentally in the natural weather conditions. The PV/T air collector has a single-pass double-flow air channel. Also, a non-uniform cross-section transverse rib was attached at the back surface of the PV (photovoltaic) module to improve the heat transfer performance between the PV module and flowing air. The experiment was carried out in an outdoor field on a clear day with various air mass flow rates ranges from 0.0198 kg/s to 0.07698 kg/s. In the results, it was found that the average thermal efficiency of the PV/T collector increased from 35.2% to 56.72% as the air mass flow rate increased. The average electrical efficiency also increased from 14.23% to 14.81% with an increase in an air mass flow rate, but the effect of air mass flow rate on the increase in electrical efficiency was inconsiderable. The average overall efficiency, which represents the sum of electrical and thermal efficiencies, was in the range of 49.44% to 71.54% and it increased as the air mass flow rate increased. The maximum value of average overall efficiency during the test period was found to be 71.54% at an air mass flow rate of 0.07698 kg/s. From the results, it was confirmed that the newly designed PV/T air collector provides a significant enhancement in solar energy utilization.