A Dynamic Model of a Single-Stage LiBr-H2O Absorption Chiller

Author(s):  
Prangtip Samutr ◽  
Ali Al Alili

This paper presents a dynamic model of a single-stage LiBr-H2O absorption chiller. A numerical model has been developed based on mass and energy balance equations and heat transfer equations. The model is developed using MATLAB program and the system of non-linear ordinary differential equation is solved using the 4th-order Runge-Kutta method. The model is validated with experimental results from pertained literature. The results show that the maximum relative error is found when comparing the dynamic model predicted chilled water outlet temperature to experimental data, which is around 9%. The effect of the inlet hot water temperature on the hot, cooling and chilled water outlet temperatures, cooling capacity and coefficient of performance (COP) are also studied. The results show that as the hot water outlet temperature increases, the outlet temperatures of cooling and chilled water slightly change. Moreover, the cooling capacity increases and the COP slight decreases as the hot water temperature increases.

Energies ◽  
2019 ◽  
Vol 12 (6) ◽  
pp. 996 ◽  
Author(s):  
Li Huang ◽  
Rongyue Zheng ◽  
Udo Piontek

A solar cooling and heating system incorporated with two air-source heat pumps was installed in Ningbo City, China and has been operating since 2018. It is composed of 40 evacuated tube modules with a total aperture area of 120 m2, a single-stage and LiBr–water-based absorption chiller with a cooling capacity of 35 kW, a cooling tower, a hot water storage tank, a buffer tank, and two air-source heat pumps, each with a rated cooling capacity of 23.8 kW and heating capacity of 33 kW as the auxiliary system. This paper presents the operational results and performance evaluation of the system during the summer cooling and winter heatingperiod, as well as on a typical summer day in 2018. It was found that the collector field yield and cooling energy yield increased by more than 40% when the solar cooling and heating system is incorporated with heat pumps. The annual average collector efficiency was 44% for cooling and 42% for heating, and the average coefficient of performance (COP) of the absorption chiller ranged between 0.68 and 0.76. The annual average solar fraction reached 56.6% for cooling and 62.5% for heating respectively. The yearly electricity savings accounted for 41.1% of the total electricity consumption for building cooling and heating.


2014 ◽  
Vol 137 (1) ◽  
Author(s):  
M. Alkhair ◽  
M. Y. Sulaiman ◽  
K. Sopian ◽  
C. H. Lim ◽  
E. Salleh ◽  
...  

The modeling of the performance of a one refrigeration ton (RT) solar assisted adsorption air-conditioning refrigeration system using activated carbon fiber/ethanol as the adsorbent/adsorbate pair has been undertaken in this study. The effects of hot water, cooling water, chilled water inlet temperatures, and hot water and chilled water flow rates were taken into consideration in the optimization of the system and in the design of the condenser, evaporator, and hot water storage tank. The study includes analysis of the weather data and its effect on both the adsorption system and the cooling load. This is then followed by estimation of the cooling capacity and coefficient of performance (COP) of the adsorption system as a function of the input parameters. The results of the model will be compared to experimental data in a next step.


Author(s):  
S. Plura ◽  
C. Kren ◽  
C. Schweigler

Aiming for the European and North American tri-generation market, highly-efficient systems are being developed. At the moment, single-stage absorption chillers are typically coupled to co-generation engines through a single hot water loop at temperatures below 100°C (210°F). In this configuration, the heat from the exhaust gas at temperatures of about 400-500°C (750-930°F) is transferred to the water loop, which is accompanied by a significant loss of exergy. A substantial increase in system performance can be achieved by a stepwise utilisation of the exhaust gas enthalpy in a Double-Effect and a Single-Effect cycle. In this combination of one-and two-stage chillers the coefficient of performance (COP) increases from about 0.7 to almost 1.0 whereby the cooling capacity rises by about 25%. In order to facilitate optimum adaptation of the aggregates - i.e. motor engine and absorption chiller - and to give maximum flexibility an innovative system concept has been developed. The new coupling scheme is based on a standard direct-fired Double-Effect chiller and introduces only minor design changes, like adaptation of the thermal layout of the exhaust gas driven regenerator heat exchanger of the chiller. No additional low temperature regenerators are required. In case of simultaneous heating and cooling the system supports a continuous switchover between maximum cooling and maximum heating capacity. In this mode up to 80% of the driving heat for cold production can be recovered as useful heat at temperatures up to 100°C (210°F). A description of the coupling scheme together with a discussion of energetic and operational characteristics of the concept is presented. Full-scale demonstration projects are under preparation.


Author(s):  
Emin Yilmaz ◽  
Abhijit Nagchaudhuri

The goal of the design project titled “Domestic Hot Water Heater Using Air Conditioner Waste Heat” was to introduce students to designing mechanical systems in the “ETME475-Mechanical Systems Design” course. Two students completed the design project in spring 2007. Some test runs were conducted with a commercial desuperheater to measure the efficiency of the unit and its effect on the Coefficient of Performance (COP) of the Heat Pump when the heat pump is operated in air conditioning (A/C) mode. Contrary to author’s expectations, results indicated that, COP values were reduced by about 22%. Measured efficiency of the desuperheater was about 18% [1]. The current project is an extension of the original project with the new National Instruments data acquisition board, a newly developed LabVIEW data acquisition program, and with a more realistic heat transfer loop. The study covers performance of the heat pump operating in A/C mode as well as in heating mode. Results indicate, depending on the water temperature in the desuperheater, heat pump COP dropped 6–17% in A/C mode and 8–38% in heating mode. Again depending on the average water temperature in the ECU, the ECU efficiencies ranged from 12% to 27% for cooling and 11% to 39% for heating.


2021 ◽  
Vol 39 (1A) ◽  
pp. 45-55
Author(s):  
Ahmed H. Al-Hassani ◽  
Alaa R. Al-Badri

The operation and performance of heat-pump systems are affected by indoor and outdoor operating conditions. Power consumption and system efficiency are related to evaporator and condenser working pressures. Intelligent controllers such as a proportional integral (PI) controller improve the performance of variable speed refrigeration systems (VSRs) with electronic expansion valve (EEV). Evaporator and condenser pressures affect the system power consumption and efficiency. In this study, the influence of evaporator and condenser temperatures on the performance of a variable speed refrigeration system with an EEV was experimentally investigated at constant cooling load. The experimental system comprises of a rotary compressor, shell-and-coil condenser, EEV, and shell-and-coil evaporator for one-ton cooling capacity with refrigerant R410. Compressor speed and EEV opening are controlled by a PI controller with two control loops and the refrigerant superheat (DS) is maintained at 7°C. The results show that at constant cooling capacity, the refrigerant flow rate rises with the increase in the compressor speed. The coefficient of performance (COP) is improved with low compressor speed. The System COP is increased by 3.3% with increasing evaporator inlet water temperature for 2°C due to the reduction in the compressor speed and compression ratio. High condenser inlet water temperature promotes the refrigerant subcooling.


Author(s):  
Le Minh Nhut ◽  
Tran Quang Danh

Hot water is an important factor in domestic life and industrial development. Today, the heat pump is used to produce hot water more and more popular because it has many advantages of saving energy compared to the method of producing hot water by the hot water electric heater. The main aim of this study is to evaluate of the coefficient of performance (COP) of the small hot water heat pump using refrigeration R410A and R32. The capacity of both hot water heat pump is similar, one using new refrigerant R32 and other using refrigerant R410A. These heat pumps were designed and installed at the Ho Chi Minh City University of Technology and Education to evaluate the COP for the purpose of application the new refrigerant R32 for hot water heat pump. The compressor capacity is 1 Hp, the volume of hot water storage tank is of 100 liters and is insulated with thickness of 30 mm to reduce the heat loss to invironment, the required hot water temperature at the outlet of condenser is 50 oC, and the amount of required hot water is 75 liters per batch and is controlled by float valve. The experimental results indicate that the COP of the heat pump using the new refrigerant R32 is higher than heat pump using refrigerant R410A from 9% to 15% when the experimental conditions such as ambient temperature, initial water flow rate through the condenser and the required temperature of hot water were the same. In addition, the effect of the ambient temperature, initial water temperature and water flow rate were also evaluated.


Author(s):  
Fadi A. Ghaith ◽  
Kamal Majlab Wars

Abstract This paper addresses the potential of integrating the existing oil wells and absorption chiller for the purpose of provision space cooling for the base camp of oil field at Block 9 located in Oman. The wellbore was used as a hot water feed to the chiller. Well S 347 was selected as the hot water source and well S 179 was selected to be the injection well for the outlet water. The existing wells were assessed via PIPESIM software. Using PIPESIM software, the fluid temperatures, well pressure and flow rates were obtained and analyzed throughout NODAL analyses. The water temperature of 100 °C, well head pressure of 100 psi and flow rate of 30 m3/h, were found to be the optimum operating parameters. The COP of the absorption chiller was obtained via ABSIM software. The variable operating conditions were investigated and elaborated as a function of the efficiency and capacity ratio. The designed system was configured to yield 0.733 COP and a capacity of 377 KW which met the cooling capacity of the admin building of block 9. The entire feasibility analysis was performed in terms of the overall cost as well as the saving that would be achieved from such homogeneity. The payback period of the entire system was found to be 7 years which emphasized a great potential of adapting the technology if the operating resources are available.


Author(s):  
V Baiju ◽  
A Asif Sha ◽  
NK Mohammed Sajid ◽  
K Muhammedali Shafeeque

This paper presents the transient model of a two-bed adsorption cooling system performed in the SIMULINK platform. The inlet chilled water temperature in the evaporator, temperature of cooling water and hot water temperature of the adsorbent bed and its effect on systems coefficient of performance, refrigeration effect and specific cooling power have been studied and presented. It is observed that the systems coefficient of performance is 0.57 when the inlet hot water temperature about 80 °C. In this study, the optimum cooling power and systems coefficient of performance are also determined in terms of the phase time, shifting duration and hot water inflow temperature. The results indicates that the cooling water and hot water inlet temperatures significantly affects the coefficient of performance, specific cooling power and cooling power of the system. The effect of mass flow rate on the cooler efficiency is also presented. A two bed adsorption system of capacity 13.5 kW having an evaporator and condenser temperatures of 6°C and 28°C, respectively, are considered for the present investigation. The adsorbent mass considered is 45 kg with a shifting duration of 20 sec. The result of this study gives the basis for performance optimization of a practical continuous operating vapour adsorption cooler.


Author(s):  
Abdolreza Zaltash ◽  
Andrei Petrov ◽  
Randall Linkous ◽  
Edward Vineyard ◽  
David Goodnack ◽  
...  

During the summer months, air-conditioning (cooling) is the single largest use of electricity in both residential and commercial buildings with the major impact on peak electric demand. Improved air-conditioning technology has by far the greatest potential impact on the electric industry compared to any other technology that uses electricity. Thermally activated absorption air-conditioning (absorption chillers) can provide overall peak load reduction and electric grid relief for summer peak demand. This paper describes an innovative absorption technology based on integrated rotating heat exchangers to enhance heat and mass transfer resulting in a potential reduction of size, cost, and weight of the “next generation” absorption units. This absorption chiller (RAC) is a 4.5 kW (1.3 refrigeration tons or RT) air-cooled lithium bromide (LiBr)/water unit powered by hot water generated using the solar energy and/or waste heat. Typically LiBr/water absorption chillers are water-cooled units which use a cooling tower to reject heat. Cooling towers require a large amount of space and increase start-up and maintenance costs. However, RAC is an air-cooled absorption chiller which requires no cooling tower. The purpose of this evaluation is to verify RAC performance by comparing the Coefficient of Performance (COP or ratio of cooling capacity to thermal energy input) and the cooling capacity results with those of the manufacturer. The performance of the RAC was tested at Oak Ridge National Laboratory (ORNL) in a controlled environment at various hot and chilled water flow rates, air handler flow rates, and ambient temperatures. Temperature probes, mass flow meters, rotational speed measuring device, pressure transducers, and a web camera mounted inside the unit were used to monitor the RAC via a web control-based data acquisition system using Automated Logic Controller (ALC). Results showed a COP and cooling capacity of approximately 0.58 and 3.7 kW respectively at 35°C (95°F) design condition for ambient temperature with 40°C (104°F) cooling water temperature. This is in close agreement with the manufacturer data of 0.60 for COP and 3.9 kW for cooling capacity. Future work will use these performance results to evaluate the potential benefits of rotating heat exchangers in making the “next-generation” absorption chillers more compact and cost effective without any significant degradation in the performance. Future studies will also evaluate the feasibility of using rotating heat exchangers in other applications.