Neuronal correlates of siphon withdrawal in freely behaving Aplysia

1979 ◽  
Vol 42 (6) ◽  
pp. 1538-1556 ◽  
Author(s):  
J. E. Kanz ◽  
L. B. Eberly ◽  
J. S. Cobbs ◽  
H. M. Pinsker

1. Central neuronal mechanisms of siphon withdrawal in Aplysia were studied for the first time in intact, freely behaving animals by means of population recordings from implanted whole-nerve cuff electrodes. Intracellular follow-up studies were then conducted when the same animal was reduced to a semi-intact preparation. 2. Background spontaneous activity in the siphon nerve consisted of low-frequency firing of a population of efferent units containing identified siphon motoneurons. 3. Spontaneous patterned bursts of efferent activity occurred irregularly and were associated with all-or-nothing contractions of the parapodia, gill, and siphon. Spontaneous bursts were due to centrally generated activity in the interneuron II (INT II) network, an oscillatory network with endogenous pacemaker properties. 4. In intact animals, even weak tactile stimuli to the siphon typically triggered an INTII burst shortly after the stimulus-locked efferent activity. Thus, the stimulus can phase-advance the INT II oscillator. In semi-intact preparations, short-latency INT II bursts were triggered less less frequently and required more intense stimuli. 5. With weak to moderate-intensity stimuli in intact animals, the presence of short-latency triggered INT II bursts largely determined the duration of the siphon component and amplitude of the gill component of the withdrawal reflex. 6. When stimuli were repeated over a range of interstimulus intervals (from 60 to 1 min), the likelihood of triggering a short-latency INT II burst die not change systematically. Thus, the ability of the siphon stimulus to stably entrain the all-or-none INT II component over a wide range of intervals will interact behaviorally with the decrement of the monosynaptic component of the reflex with repetition.

2021 ◽  
Vol 15 ◽  
Author(s):  
Matthew T. Flavin ◽  
Marek A. Paul ◽  
Alexander S. Lim ◽  
Senan Abdulhamed ◽  
Charles A. Lissandrello ◽  
...  

For many peripheral neuro-modulation applications, the cuff electrode has become a preferred technology for delivering electrical current into targeted volumes of tissue. While basic cuffs with low spatial selectivity, having longitudinally arranged contacts, can be produced from relatively straightforward processes, the fabrication of more complex electrode configurations typically requires iterative design and clean-room fabrication with skilled technicians. Although facile methods for fabricating cuff electrodes exist, their inconsistent products have limited their adoption for rapid manufacturing. In this article, we report a fast, low-cost fabrication process for patterning of electrode contacts in an implantable peripheral nerve cuff. Using a laser cutter as we have prescribed, the designer can render precise contact geometries that are consistent between batches. This method is enabled by the use of silicone/carbon black (CB) composite electrodes, which integrate with the patterned surface of its substrate—tubular silicone insulation. The size and features of its products can be adapted to fit a wide range of nerve diameters and applications. In this study, we specifically documented the manufacturing and evaluation of circumpolar cuffs with radial arrays of three contacts for acute implantation on the rat sciatic nerve. As part of this method, we also detail protocols for verification—electrochemical characterization—and validation—electrophysiological evaluation—of implantable cuff electrodes. Applied to our circumpolar cuff electrode, we report favorable electrical characteristics. In addition, we report that it reproduces expected electrophysiological behaviors described in prior literature. No specialized equipment or fabrication experience was required in our production, and we encountered negligible costs relative to commercially available solutions. Since, as we demonstrate, this process generates consistent and precise electrode geometries, we propose that it has strong merits for use in rapid manufacturing.


2009 ◽  
Vol 23 (4) ◽  
pp. 191-198 ◽  
Author(s):  
Suzannah K. Helps ◽  
Samantha J. Broyd ◽  
Christopher J. James ◽  
Anke Karl ◽  
Edmund J. S. Sonuga-Barke

Background: The default mode interference hypothesis ( Sonuga-Barke & Castellanos, 2007 ) predicts (1) the attenuation of very low frequency oscillations (VLFO; e.g., .05 Hz) in brain activity within the default mode network during the transition from rest to task, and (2) that failures to attenuate in this way will lead to an increased likelihood of periodic attention lapses that are synchronized to the VLFO pattern. Here, we tested these predictions using DC-EEG recordings within and outside of a previously identified network of electrode locations hypothesized to reflect DMN activity (i.e., S3 network; Helps et al., 2008 ). Method: 24 young adults (mean age 22.3 years; 8 male), sampled to include a wide range of ADHD symptoms, took part in a study of rest to task transitions. Two conditions were compared: 5 min of rest (eyes open) and a 10-min simple 2-choice RT task with a relatively high sampling rate (ISI 1 s). DC-EEG was recorded during both conditions, and the low-frequency spectrum was decomposed and measures of the power within specific bands extracted. Results: Shift from rest to task led to an attenuation of VLFO activity within the S3 network which was inversely associated with ADHD symptoms. RT during task also showed a VLFO signature. During task there was a small but significant degree of synchronization between EEG and RT in the VLFO band. Attenuators showed a lower degree of synchrony than nonattenuators. Discussion: The results provide some initial EEG-based support for the default mode interference hypothesis and suggest that failure to attenuate VLFO in the S3 network is associated with higher synchrony between low-frequency brain activity and RT fluctuations during a simple RT task. Although significant, the effects were small and future research should employ tasks with a higher sampling rate to increase the possibility of extracting robust and stable signals.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Jonathan A. Shulgach ◽  
Dylan W. Beam ◽  
Ameya C. Nanivadekar ◽  
Derek M. Miller ◽  
Stephanie Fulton ◽  
...  

AbstractDysfunction and diseases of the gastrointestinal (GI) tract are a major driver of medical care. The vagus nerve innervates and controls multiple organs of the GI tract and vagus nerve stimulation (VNS) could provide a means for affecting GI function and treating disease. However, the vagus nerve also innervates many other organs throughout the body, and off-target effects of VNS could cause major side effects such as changes in blood pressure. In this study, we aimed to achieve selective stimulation of populations of vagal afferents using a multi-contact cuff electrode wrapped around the abdominal trunks of the vagus nerve. Four-contact nerve cuff electrodes were implanted around the dorsal (N = 3) or ventral (N = 3) abdominal vagus nerve in six ferrets, and the response to stimulation was measured via a 32-channel microelectrode array (MEA) inserted into the left or right nodose ganglion. Selectivity was characterized by the ability to evoke responses in MEA channels through one bipolar pair of cuff contacts but not through the other bipolar pair. We demonstrated that it was possible to selectively activate subpopulations of vagal neurons using abdominal VNS. Additionally, we quantified the conduction velocity of evoked responses to determine what types of nerve fibers (i.e., Aδ vs. C) responded to stimulation. We also quantified the spatial organization of evoked responses in the nodose MEA to determine if there is somatotopic organization of the neurons in that ganglion. Finally, we demonstrated in a separate set of three ferrets that stimulation of the abdominal vagus via a four-contact cuff could selectively alter gastric myoelectric activity, suggesting that abdominal VNS can potentially be used to control GI function.


Atmosphere ◽  
2019 ◽  
Vol 10 (9) ◽  
pp. 499 ◽  
Author(s):  
Artem Shikhovtsev ◽  
Pavel Kovadlo ◽  
Vladimir Lukin

The paper focuses on the development of the method to estimate the mean characteristics of the atmospheric turbulence. Using an approach based on the shape of the energy spectrum of atmospheric turbulence over a wide range of spatial and temporal scales, the vertical profiles of optical turbulence are calculated. The temporal variability of the vertical profiles of turbulence under different low-frequency atmospheric disturbances is considered.


Author(s):  
Walter Anderson ◽  
Constantine Ciocanel ◽  
Mohammad Elahinia

Engine vibration has caused a great deal of research for isolation to be performed. Traditionally, isolation was achieved through the use of pure elastomeric (rubber) mounts. However, with advances in vehicle technology, these types of mounts have become inadequate. The inadequacy stems from the vibration profile associated with the engine, i.e. high displacement at low frequency and small displacement at high frequency. Ideal isolation would be achieved through a stiff mount for low frequency and a soft mount for high frequency. This is contradictory to the performance of the elastomeric mounts. Hydraulic mounts were then developed to address this problem. A hydraulic mount has variable stiffness and damping due to the use of a decoupler and an inertia track. However, further advances in vehicle technology have rendered these mounts inadequate as well. Examples of these advances are hybridization (electric and hydraulic) and cylinder on demand (VCM, MDS & ACC). With these technologies, the vibration excitation has a significantly different profile, occurs over a wide range of frequencies, and calls for a new technology that can address this need. Magnetorheological (MR) fluid is a smart material that is able to change viscosity in the presence of a magnetic field. With the use of MR fluid, variable damping and stiffness can be achieved. An MR mount has been developed and tested. The performance of the mount depends on the geometry of the rubber part as well as the behavior of the MR fluid. The rubber top of the mount is the topic of this study due to its major impact on the isolation characteristics of the MR mount. To develop a design methodology to address the isolation needs of different hybrid vehicles, a geometric parametric finite element analysis has been completed and presented in this paper.


2018 ◽  
Vol 7 (3) ◽  
pp. 24-46
Author(s):  
Sourav Paul ◽  
Provas Roy

In this article, an Oppositional Differential search algorithm (ODSA) is comprehensively developed and successfully applied for the optimal design of power system stabilizer (PSS) parameters which are added to the excitation system to dampen low frequency oscillation as it pertains to large power system. The effectiveness of the proposed method is examined and validated on a single machine infinite bus (SMIB) using the Heffron-Phillips model. The most important advantage of the proposed method is as it reaches toward the optimal solution without the optimal tuning of input parameters of the ODSA algorithm. In order to verify the effectiveness, the simulation was made for a wide range of loading conditions. The simulation results of the proposed ODSA are compared with those obtained by other techniques available in the recent literature to demonstrate the feasibility of the proposed algorithm.


1999 ◽  
Vol 09 (12) ◽  
pp. 2295-2303 ◽  
Author(s):  
S. RIPOLL MASSANÉS ◽  
C. J. PÉREZ VICENTE

We have studied the stochastic behavior of Fitzhugh–Nagumo neuron-like model (FN) induced by subthreshold external stimuli. Our analysis based on three standard measures: the power spectrum, interspike interval distribution (ISI) and autocorrelation function shows that it is possible to define a characteristic time scale which can be identified in the response of the system for a wide range of frequencies. In contrast to previous studies we have focused our attention on high frequency signals which could be of interest for real systems such as nervous fibers in the auditory system. We report behaviors which resemble those of classical deterministic oscillators but never the stochastic resonance phenomenon typical of low frequency signals.


2009 ◽  
Vol 131 (6) ◽  
Author(s):  
Qiao Sun ◽  
Robert A. Wolkow ◽  
Mark Salomons

The extreme sensitivity of a scanning probe microscope demands an exceptional noise cancellation device that could effectively cut off a wide range of vibration noise. Existing commercial devices, although excellent in canceling high frequency noise, commonly leave low frequency vibration unattenuated. We design an add-on active stage that can function together with a standalone existing active stage. The objective is to provide a higher level of noise cancellation by lowering the overall system cut-off frequency. This study is concerned with the theoretical aspects of the coupling characteristics involved in stacking independently designed stages together to form a two-stage isolator. Whether an add-on stage would pose a stability threat to the existing stage needs to be addressed. In addition, we explore the use of coupling effects to optimize the performance of the overall system.


Sign in / Sign up

Export Citation Format

Share Document