Surface Roughness Effect on the Solid Equilibrium Contact Angle

2017 ◽  
Vol 17 (6) ◽  
pp. 4271-4274 ◽  
Author(s):  
In-Hye Kim ◽  
Kyo-Han Kim ◽  
Jun Sik Son ◽  
Tae-Yub Kwon
2004 ◽  
Vol 11 (01) ◽  
pp. 7-13 ◽  
Author(s):  
XINPING ZHANG ◽  
SIRONG YU ◽  
ZHENMING HE ◽  
YAOXIN MIAO

This paper focuses on effects of roughness on wettability. According to Wenzel's equation, the transition of theoretical wetting contact angles is 90°, whereas many experimental results have indicated that such a transition takes place at contact angles smaller than 90°. A new model of wetting on roughness surface is established in this paper. The model indicates that the influencing factors of wetting on roughness surface include not only equilibrium contact angle θ0 and surface roughness, but also the system of liquids and solid substrates. There is a corresponding transition angle for every surface roughness, and the transition angle is lower than 90°. Surface roughness is propitious to improve the contact angle only when θ0 is lower than the transition angle. The effect of surface roughness on the contact angle increases with the increase of rE. To engineer the surface with different roughnesses, a Ti test sample is polished with sandpaper with abrasive number 350, 500, 1000 and 2000; the contact angles of water on Ti are measured by the sessile drop method. The results of the theoretical analysis agree with experimental ones.


Coatings ◽  
2020 ◽  
Vol 10 (9) ◽  
pp. 856 ◽  
Author(s):  
Qingqing Liu ◽  
Di Gao ◽  
Wei Xu

The surface roughness, static and dynamic liquid wettability of modified poplar wood were measured by different surface treatment of brushing primer and sanding. With the increase of the number of grinding paper, the depth parameters Ra, Ry, Rz and Rp of surface roughness of modified poplar decreased, and the density parameter Sm (the average spacing of micro unevenness of contour) decreased at first and then increased. With the increase of number of the grinding paper, the contact angle of water and glycerol for modified poplar wood decreased at first and then increased. After the modified poplar wood was brushed with the primer and sanded with 240# sandpaper, the density parameter Sm was 0.307, the equilibrium contact angle of distilled water was 34.88, and the equilibrium contact angle of glycerin was 36.46, all of which were the lowest number. At this time, the surface roughness was improved, and the modified poplar has the good wettability that is greater than the mahogany wood wettability. Compared with mahogany, the rough depth parameters of the modified poplar are smaller to those of mahogany, but the Sm of modified poplar wood is greater than that of the mahogany. After the same surface pretreatment, the wetting speed of glycerol on the surface of mahogany is higher than that of the modified poplar.


2021 ◽  
Vol 224 ◽  
pp. 108690
Author(s):  
Xiangxi Han ◽  
Youhong Tang ◽  
Zhanbin Meng ◽  
Fei Fu ◽  
Ang Qiu ◽  
...  

Coatings ◽  
2021 ◽  
Vol 11 (4) ◽  
pp. 479
Author(s):  
Yang Zhao ◽  
Fan Sun ◽  
Peng Jiang ◽  
Yongle Sun

The effects of surface roughness on the stresses in an alumina scale formed on a Fecralloy substrate are investigated. Spherical indenters were used to create indents with different radii and depths to represent surface roughness and then the roughness effect was studied comprehensively. It was found that the residual stresses in the alumina scale formed around the rough surface are almost constant and they are dominated by the curvature rather than the depth of the roughness. Oxidation changes the surface roughness. The edge of the indent was sharpened after oxidation and the residual stress there was released presumably due to cracking. The residual stresses in the alumina scale decrease with increase in oxidation time, while the substrate thickness has little effect, given that the substrate is thicker than the alumina scale. Furthermore, the effect of roughness on the oxide growth stress is analysed. This work indicates that the surface roughness should be considered for evaluation of stresses in coatings.


2019 ◽  
Vol 60 ◽  
pp. 124-141 ◽  
Author(s):  
Naser Ali ◽  
Joao Amaral Teixeira ◽  
Abdulmajid Addali

This research investigates the effect of surface roughness, water temperature, and pH value on the wettability behaviour of copper surfaces. An electron beam physical vapour deposition technique was used to fabricate 25, 50, and 75 nm thin films of copper on the surface of copper substrates. Surface topographical analysis, of the uncoated and coated samples, was performed using an atomic force microscopy device to observe the changes in surface microstructure. A goniometer device was then employed to examine the surface wettability of the samples by obtaining the static contact angle between the liquid and the attached surface using the sessile drops technique. Waters of pH 4, 7, and 9 were employed as the contact angle testing fluids at a set of fixed temperatures that ranged from 20°C to 60°C. It was found that increasing the deposited film thickness reduces the surface roughness of the as-prepared copper surfaces and thus causing the surface wettability to diverge from its initial hydrophobic nature towards the hydrophilic behaviour region. A similar divergence behaviour was seen with the rise in temperature of water of pH 4, and 9. In contrast, the water of pH 7, when tested on the uncoated surface, ceased to reach a contact angle below 90o. It is believed that the observed changes in surface wettability behaviour is directly linked to the liquid temperature, pH value, surface roughness, along with the Hofmeister effect between the water and the surface in contact.


2012 ◽  
Author(s):  
Narjes Shojaikaveh ◽  
Cas Berentsen ◽  
Susanne Eva Johanne Rudolph-Floter ◽  
Karl Heinz Wolf ◽  
William Richard Rossen

2005 ◽  
Vol 8 (1) ◽  
Author(s):  
Jeou-Long Lee ◽  
Chung-Ming Liu ◽  
Kuen Ting ◽  
Wei-Kung Cheng ◽  
Takayoshi Tsuchida ◽  
...  

AbstractSurface modification of the carbon included polyethylene (semi-conductive PE) surface for metallizing using a low pressure RF discharge plasma has been carried out. The contact angle was used as a measure of the wettability of the PE surface. The roughness and the chemical bondings in PE surface layer were analized by DFM and XPS, respectively. Typical results show that the contact angle decreases from approximately 94° to below 10° after several minutes' treatment and recovers to a saturation value when it was put open to the air after treatment. The saturation value of the contact angle is smaller as the gas pressure for treatment is higher and the treatment time is longer but all are below approximately 60° which is still smaller than that of untreated. DFM and XPS results show that the surface roughness and the bondings C-O and C=O in the PE surface layer also increase with increasing the treatment time and seem to be responsible for improving the hydrophilic property of PE. After pretreatment process, nickel was coated on the PE sheet by electrodeposition method and a good adhesion between the nickel layer and the PE surface compared with that of untreated was obtained.


Author(s):  
M.N. Obaid ◽  
S.H. Radhi

Purpose: The number of people suffering from Degenerative Disc Disease (DDD) is increasing. The disease causes heavy pain and restrict a number of day-to-day life activities. In extreme cases, the degraded disc is removed under total disc replacement which is usually made up of Ultra-High Molecular Weight Polyethylene (UHMWPE). The material has astounding biocompatible characteristics mechanical properties and wear resistance. However, these characteristics are insufficient in arthroplasty application. Therefore, research investigations are ongoing to improve tribological properties through reinforcement that may result in a composite material of UHMWPE. Thus the current study is aimed at reinforcing UHMWPE with short fibres of polyesters to enhance the tribological properties and surface characteristic so as to improve wear resistance and nourish the fibroblast cells on synthetic disc. Design/methodology/approach: The researcher prepared UHMWPE composite material, reinforced with different weight fractions of short polyester fibres (2, 4, 6, 8 and 10% following hot press method. Further pin-on-disc device was used to study the tribological properties (coefficient of friction and volume of wear). The study tested surface roughness and surface characteristics by atomic force microscopy (AFM) device, hardness by shore D device, contact angle to study the effect of polyester short fibres on wettability of UHMWPE surface and tested the thermal properties and crystalline degree using Differential Scanning Calorimetry measurement (DSC) device. Findings: The results infer that the wear resistance got improved when using 2% w.t polyester though it got decreased initially. However, the value was still more than neat UHMWPE. There was a decrease observed in coefficient of friction, but after 4 w.t% polyester, the coefficient of friction got increased due to increasing percentage of fibres which make it harder and stiff compared to UHMWPE. There was a decline observed in surface roughness due to alignment of the fibres with smooth surface. The contact angle got increased in a moderate range while the roughness enhanced the growth of fibroblast cell. The hardness of composite material got increased, because the fibres turned stiffer and harder than the matrix. DSC results infer the improvements in thermal stability due to high thermal properties of polyester fibres compared to UHMWPE. The degree of crystallinity got increased which in turn enhanced wear resistance, especially at 6 w.t % polyester fibres. There was a mild increase observed in density since the density of polyester is higher than polymer. Research limitations/implications: The major challenge was the dispersion of fibres. Uniform distribution of fibres within the matrix (UHMWPE) was achieved through two steps of mixing processes such as mechanical mixture and twin extruder. In future studies, fatigue tests must be conducted to study the behaviour of prepared composite materials under fatigue cycle. Practical implications: A significant objective is how to connect among different properties to obtain good improvement in tribological and surface properties so as to enhance wear resistance and growth of fibrolase cells. Originality/value: In this study, polymeric short fibres were used as reinforcement with polymeric matrix to enhance the wettability of fibres with matrix. In this way, the bonding among them got increased which supports the tribological, surface, and crystalline behaviour.


2001 ◽  
Author(s):  
Jih-Hsing Tu ◽  
Fangang Tseng ◽  
Ching-Chang Chieng

Abstract Present study investigates the roughness effect on laminar gas flow for microchannels ranging from 40 to 600 μm with various roughness heights (40–82 nm) by systematical experiments. The micro-channels are manufactured by micro-machining technology and KOH anisotropic etching is employed to achieve various roughness patterns. Experimental results shows that higher product levels of Reynolds number (Reh) and friction factor (f) are obtained for microchannels of larger size and smaller relative roughness and friction factor f approaches to laminar flow theory value f0 for very smooth channel but the ratio of (f/f0) decreases as the surface roughness increases.


Author(s):  
Anand N. P. Radhakrishnan ◽  
Marc Pradas ◽  
Serafim Kalliadasis ◽  
Asterios Gavriilidis

Micro-engineered devices (MED) are seeing a significant growth in performing separation processes1. Such devices have been implemented in a range of applications from chemical catalytic reactors to product purification systems like microdistillation. One of the biggest advantages of these devices is the dominance of capillarity and interfacial tension forces. A field where MEDs have been used is in gas-liquid separations. These are encountered, for example, after a chemical reactor, where a gaseous component being produced needs immediate removal from the reactor, because it can affect subsequent reactions. The gaseous phase can be effectively removed using an MED with an array of microcapillaries. Phase-separation can then be brought about in a controlled manner along these capillary structures. For a device made from a hydrophilic material (e.g. Si or glass), the wetted phase (e.g. water) flows through the capillaries, while the non-wetted dispersed phase (e.g. gas) is prevented from entering the capillaries, due to capillary pressure. Separation of liquid-liquid flows can also be achieved via this approach. However, the underlying mechanism of phase separation is far from being fully understood. The pressure at which the gas phase enters the capillaries (gas-to-liquid breakthrough) can be estimated from the Young-Laplace equation, governed by the surface tension (γ) of the wetted phase, capillary width (d) and height (h), and the interface equilibrium contact angle (θeq). Similarly, the liquid-to-gas breakthrough pressure (i.e. the point at which complete liquid separation ceases and liquid exits through the gas outlet) can be estimated from the pressure drop across the capillaries via the Hagen-Poiseuille (HP) equation. Several groups reported deviations from these estimates and therefore, included various parameters to account for the deviations. These parameters usually account for (i) flow of wetted phase through ‘n’ capillaries in parallel, (ii) modification of geometric correction factor of Mortensen et al., 2005 2 and (iii) liquid slug length (LS) and number of capillaries (n) during separation. LS has either been measured upstream of the capillary zone or estimated from a scaling law proposed by Garstecki et al., 2006 3. However, this approach does not address the balance between the superficial inlet velocity and net outflow of liquid through each capillary (qc). Another shortcoming of these models has been the estimation of the apparent contact angle (θapp), which plays a critical role in predicting liquid-to-gas breakthrough. θapp is either assumed to be equal to θeq or measured with various techniques, e.g. through capillary rise or a static droplet on a flat substrate, which is significantly different from actual dynamic contact angles during separation. In other cases, the Cox-Voinov model has been used to calculate θapp from θeq and capillary number. Hence, the empirical models available in the literature do not predict realistic breakthrough pressures with sufficient accuracy. Therefore, a more detailed in situ investigation of the critical liquid slug properties during separation is necessary. Here we report advancements in the fundamental understanding of two-phase separation in a gas-liquid separation (GLS) device through a theoretical model developed based on critical events occurring at the gas-liquid interfaces during separation.


Sign in / Sign up

Export Citation Format

Share Document